• Title/Summary/Keyword: Reliability Simulator

Search Result 287, Processing Time 0.026 seconds

the power flow control and voltage compensation by 20kVA prototype UPFC (20kVA급 Prototype UPFC의 전력조류제어와 모선전압보상)

  • Jeon, Jin-Hong;Kim, Ji-Won;Chun, Yeung-Han;Kim, Hak-Man;Kook, Kyung-Soo;Oh, Tae-Kyoo
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.349-352
    • /
    • 2001
  • FACTS technology is developed into the sophisticated system technology which combines conventional power system technology with power electronics, micro-process control, and information technology. Its objectives are achieving enhancement of the power system flexibility and maximum utilization of the power transfer capability through improvements of the system reliability, controllability, and efficiency [1]. As a series and shunt compensator, UPFC consists of two inverters with common dc link capacitor bank. It controls the magnitude of shunt bus voltage and real and reactive power flow of transmission line[2]. In this paper, we present the design, implementation and test results of developed 20kVA level prototype UPFC. It is applied to power system simulator and controls the real and reactive power flow and shunt bus voltage magnitude.

  • PDF

A Study on the Design of Compact Polymer Bushing with Inner Control Shield (내부쉴드 구조에 따른 컴팩트한 폴리머 부싱 설계에 관한 연구)

  • Cho, Han-Goo;Yoo, Dae-Hoon;Kang, Hyung-Kyung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.5
    • /
    • pp.436-442
    • /
    • 2009
  • This paper describes a study on the design of compact polymer bushing with inner control shield. In the bushing, a high electric stress occurred between field shaper and central conductor by the closely space. Also coaxial cylindrical shield has a great height along the axis to control an electric field. Consequently, all the potentials are raised axially along the field shaper and electric stress is concentrated on a part of the surface of the FRP tube near the upper end of the field shaper. In accordance, the field control can be achieved by means of the designs of such inner control shields. The floating and ring shield designs was decreased electric field concentration at critical parts of the bushing. The shield gaps is formed between field shaper and ring shield. Accordance equipotential lines extend through gaps. As a result, the resulting electrical stress are thus reduced in the range $17{\sim}23%$ in the bushing with floating and ring shield designs. Maxwell 2D simulator based on the boundary element method was also introduced in order to verify the reliability of the polymer bushing. The optimized design uses internal elements for electric stress grading at critical parts of the bushing.

Warhead Tracking Filter for FMCW Seekers with Anti-Ballistic Missile Capability (대탄도탄 FMCW 탐색기를 위한 탄두부 추적 필터 설계)

  • Han, Seul-Ki;Ra, Won-Sang;Park, Jin-Bae;Hong, Young-Gon;Park, Sung-Ho;Sun, Woong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.5
    • /
    • pp.726-734
    • /
    • 2012
  • In this paper, a practical warhead tracking filter is proposed for developing a FMCW (Frequency Modulation Continuous Wave) seeker with anti-ballistic missile capability. For reliable warhead tracking, the measurement originated from the warhead section of a ballistic target should be separated from other measurements. Futhermore, since the FMCW seeker is based on triangular frequency modulation, the multiple measurements obtained in different chirp periods should be properly associated. As a systematic way to solve the problem, the measurement pairing problem under cluttered environment is reformulated as a data association filtering problem and the PDA (Probabilistic Data Association) scheme is applied. The proposed warhead tracking filter provides better warhead tracking performance compared to the conventional range tracking algorithm and nearest neighbor warhead tracking filter. The effectiveness and reliability of the proposed method are verified using the FMCW seeker simulator.

Development of High-speed Elevator Drive System using Permanent-magnet Synchronous Motor (영구 자석형 동기 전동기를 이용한 고속 엘리베이터 구동 시스템 개발)

  • Ryu Hyung-Min;Kim Sung-Jun;Sul Seung-Ki;Kwon Tae-Seok;Kim Ki-Su;Shim Young-Seok;Seok Ki-Riong
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.385-388
    • /
    • 2001
  • In this paper, the gearless traction machine drive system using a permanent-maget motor for high-speed elevators is addressed. This application of permanent-magnet motor to the elevator traction machine enables several improvements including higher efficiency, better ride comfort, smaller size and weight, and so on. PWM boost converter is also adopted so that DC-link voltage regulation, hi-directional power flow, and controllable power factor with reduced input current harmonics are possible. To increase reliability and performance, the control board, which can include the car and group controller as well as PWM converter and inverter controller, is designed based on TMS320VC33 DSP The simulator system for high-speed elevators has been developed so that the drive system of high-speed elevator can be tested without my limitation on ride distance and the load condition. Some experimental results are given to verify the effectiveness of the developed system.

  • PDF

A Routing Protocol for Improving Path Stability in Mobile Ad-hoc Networks (애드혹 네트워크에서 경로 안정성 향상을 위한 라우팅 프로토콜)

  • Kim, Hyungjik;Choi, Sunwoong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.7
    • /
    • pp.1561-1567
    • /
    • 2015
  • Nodes of Mobile ad-hoc network usually use the energy-limited battery. Balanced energy consumptionis important to maintain path's stability. In this paper, we focus on improving the stability of the routing path in mobile ad-hoc networks. For that purpose, we propose a new routing protocol to find the highest minimum node residual energy path among shortest paths. The largest path of minimum value of the remain energy has a longer life than other paths to improve the reliability to data-transmission. Using ns-3 simulator, we show that the proposed routing protocol can provide more long-life stable routing path than AODV and EA-AODV.

Operational Characteristic Analysis of EES using Real-Time Simulator (실시간 시뮬레이터를 활용한 EES 기능분석)

  • Park, Ah-Ryeon;Ryu, Kang-Yeul;Lee, Chung-Woo;Gang, Ho-Hyeon;Kang, Byung-Kwan;Koh, Kwang-Soo;Oh, Seung-Hun;Choi, Eun-Sik;Lee, Yun-Jae;Kim, Hee-Jung
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.504-505
    • /
    • 2014
  • In this paper, by using hardware in the loop(HIL) of the EES, which is an inverter of high-rated technique and analyze the function. By exchanging information between the simulation and system controller to be used in a live system, HIL approach, approach experimental is used to interpret the system mass analysis is not possible in a real system some. This paper presents the implementation of the EES and the RTDS DSP28335 is a real-time connection to the electrical signal, and to verify the actual system is difficult, it was possible to analyze the performance of the system. Thus, it is expected to contribute I raise the stability and reliability of the operation during the actual EES is built.

  • PDF

MRFR - Multipath-based Routing Protocol with Fast-Recovery of Failures on MANETs

  • Ngo, Hoai Phong;Kim, Myung Kyun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.12
    • /
    • pp.3081-3099
    • /
    • 2012
  • We propose a new multipath-based reliable routing protocol on MANETs, Multipath-based Reliable routing protocol with Fast-Recovery of failures (MRFR). For reliable message transmission, MRFR tries to find the most reliable path between a source and a destination considering the end-to-end packet reception reliability of the routes. The established path consists of a primary path that is used to transmit messages, and the secondary paths that are used to recover the path when detecting failures on the primary path. After establishing the path, the source transmits messages through the primary path. If a node detects a link failure during message transmission, it can recover the path locally by switching from the primary to the secondary path. By allowing the intermediate nodes to locally recover the route failure, the proposed protocol can handle the dynamic topological change of the MANETs efficiently. The simulation result using the QualNet simulator shows that the MRFR protocol performs better than other protocols in terms of the end-to-end message delivery ratio and fault-tolerance capability.

Development of Design Alternative Analysis Program Considering RAM Parameter and Cost (RAM 파라미터와 비용을 고려한 설계대안 분석 프로그램 개발)

  • Kim, Han-sol;Choi, Seong-Dae;Hur, Jang-wook
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.6
    • /
    • pp.1-8
    • /
    • 2019
  • Modern weapon systems are multifunctional, with capabilities for executing complex missions. However, they are required to be highly reliable, which increases their total cost of ownership. Because it is necessary to produce the best results within a limited budget, there is an increasing interest in development, acquisition, and maintenance costs. Consequently, there is a need for tools that calculate the lifecycle costs of weapons systems development to facilitate decision making. In this study, we propose a cost calculation function based on the Markov process simulator-a reliability, availability, and maintainability analysis tool developed by applying the Markov-Monte Carlo method-as an alternative to these requirements to facilitate decision-making in systems development.

Power Hardware-in-the-Loop (PHIL) Simulation Testbed for Testing Electrical Interactions Between Power Converter and Fault Conditions of DC Microgrid (컨버터와 DC 마이크로그리드 사고 상황의 상호작용을 검증하기 위한 실시간 전력 시뮬레이션 테스트 베드)

  • Heo, Kyung-Wook;Jung, Jee-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.2
    • /
    • pp.150-157
    • /
    • 2021
  • Nowadays, a DC microgrid that can link various distributed power sources is gaining much attention. Accordingly, research on fault situations, such as line-to-line and line-to-ground faults of the DC microgrid, has been conducted to improve grid reliability. However, the blackout of an AC system and the oscillation of a DC bus voltage have not been reported or have not been sufficiently verified by previous research. In this study, a 20 kW DC microgrid testbed using a power HIL simulation technique is proposed. This testbed can simulate various fault conditions without any additional grid facilities and dangerous experiments. It includes the blackout of the DC microgrid caused by the AC utility grid's blackout, a drastic load increment, and the DC bus voltage oscillation caused by the LCL filter of the voltage source converter. The effectiveness of the proposed testbed is verified by using Opal-RT's OP5707 real-time simulator with a 3 kW prototype three-port dual-active-bridge converter.

Customized Evacuation Pathfinding through WSN-Based Monitoring in Fire Scenarios (WSN 기반 화재 상황 모니터링을 통한 대피 경로 도출 알고리즘)

  • Yoon, JinYi;Jin, YeonJin;Park, So-Yeon;Lee, HyungJune
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.11
    • /
    • pp.1661-1670
    • /
    • 2016
  • In this paper, we present a risk prediction system and customized evacuation pathfinding algorithm in fire scenarios. For the risk prediction, we apply a multi-level clustering mechanism using collected temperature at sensor nodes throughout the network in order to predict the temperature at the time that users actually evacuate. Based on the predicted temperature and its reliability, we suggest an evacuation pathfinding algorithm that finds a suitable evacuation path from a user's current location to the safest exit. Simulation results based on FDS(Fire Dynamics Simulator) of NIST for a wireless sensor network consisting of 47 stationary nodes for 1436.41 seconds show that our proposed prediction system achieves a higher accuracy by a factor of 1.48. Particularly for nodes in the most reliable group, it improves the accuracy by a factor of up to 4.21. Also, the customized evacuation pathfinding based on our prediction algorithm performs closely with that of the ground-truth temperature in terms of the ratio of safe nodes on the selected path, while outperforming the shortest-path evacuation with a factor of up to 12% in terms of a safety measure.