• Title/Summary/Keyword: Release Rate

Search Result 2,219, Processing Time 0.034 seconds

The Effect of Solution Pressure to the Release in a Supercooled Aqueous Solution

  • Kang, Chae-Dong;Kim, Byung-Seon;Hong, Hi-Ki
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.1
    • /
    • pp.25-31
    • /
    • 2009
  • Supercooled type ice storage system with aqueous solution (or water) may have trouble with non-uniform release of supercooling even though it contributes to the simplicity of system and ecological improvement. The non-uniform release increases the instability of the system because it may cause an ice blockage in pipe or cooling part. In order to suppress the release of the supercooling, a cooling experiment was tried to an ethylene glycol(EG) 3 mass% solution corresponding with pressurization. Also, the frequency ratio of the release of the supercooling was measured to the pressurization from 101 to 505 kPa. At results, the frequency ratio of supercooling release tends to decrease as the pressure of the aqueous solution increased in each cooling rate. Moreover, it tends to decrease as the cooling rate of the solution decreased in each pressure.

Dissoultion and Rectal Absorption of Acetaminophen from Suppositories (아세트아미노펜 좌제의 용출과 직장흡수)

  • 한정선;심창구;김신근
    • YAKHAK HOEJI
    • /
    • v.31 no.5
    • /
    • pp.286-295
    • /
    • 1987
  • The relationship between in vitro release and in vivo bioavailability of acetaminophen from suppositories was investigated. Effect of glycyrrhizin on the drug release and rectal absorption in rats was also examined. Suppositories containing 25mg of acetaminophen were prepared with Wecobee FS (fatty base) or PEG (water-soluble base) bases. The release from the suppositories were determined with USP rotating basket dissolution apparatus and with the suppository release tester. The temperature of the dissolution medium was very critical for the dissolution of acetaminophen from Wecobee FS suppositories. The bioavailability of acetaminophen was calculated from the plasma concentration-time curve after rectal administration of the suppositories to the rats. There were no significant differences in AUC following rectal administration of Wecobee FS and PEG suppositories, but the release and absorption from the Wecobee FS suppositories were faster than those from PEG suppositories. The dissolution rate obtained by the suppository release tester was better correlated with in vivo absorption rate constant than that by the USP dissolution apparatus. It suggests that the partitioning between rectal fluid and suppository base is the rate-limiting step in the rectal absorption of acetaminophen from suppositories. Glycyrrhizin was found not to affect in vitro dissolution and rectal absorption of acetaminophen.

  • PDF

Biphasic Release Characteristics of Dual Drug-loaded Alginate Beads

  • Lee, Beom-Jin;Cui, Jing-Hao;Kim, Tae-Wan;Heo, Min-Young;Kim, Chong-Kook
    • Archives of Pharmacal Research
    • /
    • v.21 no.6
    • /
    • pp.645-650
    • /
    • 1998
  • The dual drug-loaded alginate beads simultaneously containing drug in inner and outer layers were prepared by dropping plain (single-layered) alginate beads into $CaCl_2$ solution. The release characteristics were evaluated in simulated gastric fluid for 2 h followed by intestinal fluids thereafter for 12 h. The surface morphology and cross section of dual drug-loaded alginate beads was also investigated using scanning electron microscope (SEM). The poorlv water-soluble ibuprofen was chosen as a model drug. The surface of single-layered and dual drug-loaded alginate beads showed very crude and roughness, showing aggregated particles, surface cracks and rough crystals. The thickness of dual drug-loaded alginate beads surrounded by outer layer was ranged from about 57 to 329mcm. The distinct chasm between inner and outer layers was also observed. In case of single-layered alginate bead, the drug was not released in gastric fluid but was largely released in intestinal fluid. However, the release rate decreased as the reinforcing $Eudragit^{\circledR}$ polymer contents increased. When the plasticizers were added into polymer, the release rate largely decreased. The release rate of dual drug-loaded alginate beads was stable in gastric fluid for 2 h but largely increased when switched in intestinal fluid. The drug linearly released for 4 h followed by another linear release thereafter, showing a distinct biphasic release characteristics. There was a difference in the release profiles between single-layered and dual drug-loaded alginate beads due to their structural shape. However, this biphasic release profiles were modified by varying formulation compositions of inner and outer layer of alginate beads. The release rate of dual drug-loaded alginate beads slightly decreased when the outer layer was reinforced with $Eudragit^{\circledR}$ RS1OO polymers. In case of dual drug-loaded alginate beads with polymer-reinforced outer layer only, the initial amount of druc released was low but the initial release rate (slope) was higher due to more swellable inner cores when compared to polymer-reinforced inner cores. The current dual drug-loaded alginate beads may be used to deliver the drugs in a time dependent manner.

  • PDF

Design Criterion for the Size of Micro-scale Pt-catalytic Combustor in Respect of Heat Release Rate (열 방출률에 대한 마이크로 백금 촉매 연소기의 치수 설계 기준)

  • Lee, Gwang Goo;Suzuki, Yuji
    • Journal of the Korean Society of Combustion
    • /
    • v.19 no.4
    • /
    • pp.49-55
    • /
    • 2014
  • Design criterion for the size of micro Pt-catalytic combustor is investigated in terms of heat release rate. One-dimensional plug flow model is applied to determine the surface reaction constants using the experimental data at stoichiometric butane-air mixture. With these reaction constants, the mass fraction of butane and heat release rate predicted by the plug flow model are in good agreement with the experimental data at the combustor exit. The relationship between the size of micro catalytic combustor and mixture flowrate is introduced in the form of product of two terms-the effect of fuel conversion efficiency, and the effect of chemical reaction rate and mass transfer rate.

Heat Release Rate Comparison of Electric motor car's Interior panels (국내 전동차 내장판 발열량 비교)

  • Lee Cheul-Kyu;Jung Woo-Sung;Lee Duk-Hee
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.295-300
    • /
    • 2003
  • Experimental comparison was done for measuring Heat Release Rate and Smoke Production Rate of electric motor car's interior panels using cone calorimeter. Radiative heat flux of $50kW/m^2$ was used to simulate the condition of fully developed fire case in the tests. It was observed that Heat Release Rate and Smoke Production Rate curves were shown differently according to interior materials. From experiment's results we can deduce that materials having higher rate of heat release smolder more smoke. It needs to establish fire risk propensity of each material and to set up the standards urgently.

  • PDF

A Study on the Calculation of Heat Release Rate to Compensate the Error due to Single Zone Assumption in Diesel Engines (단일 영역 모델 열발생율 계산 방법의 개선에 관한 연구)

  • Kim Ki-Doo;Yoon Wook-Hyeon;Ha Ji-Soo;Ryu Seung-Hyup
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.7
    • /
    • pp.1063-1071
    • /
    • 2004
  • Accurate heat release analysis of cylinder pressure data is important for evaluating performance in the development of diesel engine However, traditional single zone first law heat release model(SZM) has significant limitations due to the simplified assumption of uniform charge and neglecting local temperature inside cylinder during combustion process. In this study. heat release rate based on single zone heat release model has been evaluated by comparison with computational analysis results using Fire code which is based on multi-dimensional model(MDM). To overcome limitations due to simplicity of single zone assumption. especially the influence of specific heat ratio on gross heat release has been esteemed and newly suggested were the equation $\gamma$= $\gamma$(${T/T}_{max}$) which describes the variations of gases thermodynamic properties with mean temperature and maximum mean temperature inside cylinder Single zone heat release model applied with this equation is shown to give very good results over whole range of operating conditions when compared with computational analysis results based on multi-dimensional model.

Preparation and In Vivo Evaluation of Huperzine A-Loaded PLGA Microspheres

  • FU XU-DONG;GAO YONG-LIANG;PING QI-LENG;Ren Tang
    • Archives of Pharmacal Research
    • /
    • v.28 no.9
    • /
    • pp.1092-1096
    • /
    • 2005
  • Huperzine A-loaded microspheres composed of poly(D,L-lactide-co-glycolide) were prepared by an O/w emulsion solvent evaporation method. The characterization of the microspheres such as drug loading, size, shape and release profile was described. The in vitro release in the initial 7 days was nearly linear with $10\%$ released per day. Thereafter drug release rate became slow gradually and about $90\%$ drug released at day 21. The in vitro release rate determined by dialysis bag method had a good correlation with the in vivo release rate. Huperzine A aqueous solution was intramuscularly injected (i.m.) at 0.4mg/kg and microspheres were intra­muscularly injected at 8.4 mg eq huperzine A/kg in rats. The maxium plasma concentration $(C_{max})$ after i.m. microspheres was only $32\%$ of that after i.m. solution. Drug in plasma could be detectd until day 14 and about $5\%$ of administered dose was residued at the injection site at day 14. The relative bioavailability of huperzine A microspheres over a period of 14 days was $94.7\%$. Inhibition of acyecholinesterase activity (AchE) in rat's cortex, hippocampus and striatum could sustain for about 14 days. In conclusion, huperzine A-loaded microspheres possessed a prolonged and complete drug release with significant inhibition of AchE for 2 weeks in rats.

The Energy Release Rate of the Two Dimensional Cracked Body Under Thermal Stresses, Body Forces and Crack-Face Tractions (열응력, 내력 및 균열 경계하중을 고려한 2차원 균열문제의 에너지방출율)

  • 이태원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2172-2180
    • /
    • 1993
  • Under general loadings, including body forces, crack-face tractions and thermal loading, the energy release rate equation for a two-dimensional cracked body is presented. Defining the virtual crack extension as the variation of the geometry, the equation is directly derived by a shape design sensitivity of the potential energy. Although the form of the derived energy release rate equation is different from other researchers's results, the three example show that the former is exactly the same as the latter. However, the final integral equation do not involve the derivative of the displacement on the crack surface and crack tip region, thereby improving the numerical accuracy in the computation of the energy relase rate. Moreover, as it was derived from the governing equation including non-linear elasticity without special assumptions, the energy release rate of a elasto-plastic fracture can be obtained and any numerical stress analysis method can be applied.

Heparin Release from Hydrophobic Polymers : (I) In Vitro Studies

  • Kim, Sung-Ho;Kim, Sung-Wan
    • Archives of Pharmacal Research
    • /
    • v.9 no.4
    • /
    • pp.193-199
    • /
    • 1986
  • The release of heparin from monolithic devices composed of different ratios of polythylene oxide (PEO MW 20,000) and hydrophobic polydimethylsiloxane or polyurethane was investigated. Water soluble PEO blended into the polymers provided a controlled release of heparin. The release rate of heparin could be controlled by varying the content of PEO. The heparin release rate from the devices increased as the content of PEO in the devices increased. The release mechanism may be associated with the creation of pore of domain through the devices following the swelling and the change in the physical structure of the polymer network. Hydrophobic polydimethylsiloxanes and polyurethanes containing PEO can provide an antith rombogenic material for prologed release of heparin from blended system.

  • PDF

An Analysis of False Alarm Threshold Value by Heat Detector Using Heat Release Rate (열방출률을 이용한 열감지기의 오동작 경계값 분석)

  • 홍성호;김두현
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.26-30
    • /
    • 2003
  • This paper presents a study on the analysis for false alarm of heat detector using HRR(Heat Release Rate). And it is represented to threshold value and domain of false alarm. The HRR threshold value of false alarm is calculated to use parameters obtained by small scale fire-experiment. The experiment is conducted to measure detector activation time and flame spread of wood cribs fire, etc. The results show that HRR threshold value of Fixed type detector is 20.24 kW and rate of rise type detector is 13.59 kW, respectively.