• 제목/요약/키워드: Release Load

검색결과 245건 처리시간 0.027초

유리섬유/폴리프로필렌 복합재에서 섬유 함유비가 파괴특성에 미치는 영향에 대한 연구 (A Study of Fiber Content Effect on the Fracture Behavior of Glass/Polypropylene Composites)

  • 이경엽;신동혁;이중희
    • 한국자동차공학회논문집
    • /
    • 제9권5호
    • /
    • pp.173-178
    • /
    • 2001
  • This study investigates the effect of fiber content on the fracture behavior of thermoplastic composites (glass fiber/polypropylene). The fiber contents used were 20%, 30%, and 40% by weight. Fracture tests were performed using compact tension (CT) specimens made of composite sheets of three fiber contents (20%, 30%, 40%). The results showed that compliance, fracture load, and fracture toughness were affected by the fiber content. The compliance decreased with fiber content while the fracture load increased as the fiber content increased. The fracture toughness also increased as fiber content increased. Specifically, the fracture toughness increased 14% as the fiber content increased from 20% to 40%.

  • PDF

$MgO/H_2O$ 계 화학식 열펌프의 열적 특성에 관한 연구 (A Study on the Thermal Characteristics of a $MgO/H_2O$ Chemical Heat Pump)

  • 권오경;윤재호;김정욱;이진호
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.34-41
    • /
    • 2004
  • The chemical heat pump based on the Dehydration/Hydration process with a MgO/$H_2O$ system has been researched. The reactor bed could be expected to store the heat around 200∼37$0^{\circ}C$ by the dehydration reaction and to release the heat around 100∼16$0^{\circ}C$ by the hydration reaction under the heat amplification mode operation. The heat output rate of the heat pump system was evaluated using the experimentally determined parameters. The results show that 6∼50 W/kg of heat output and 0.5∼0.8 of heat recovery ratio are attainable. The heat pump will be applicable for a load leveling in a co-generation system by chemical storage of surplus heat at low heat demand and by supplying heat in the peak load period.

일방향 복합재료 single-lap 접합 조인트의 파괴 특성 (Fracture Characteristics Unidirectional Composite Single-Lap Bonded Joints)

  • 김광수;유재석;장영순;이영무
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2004년도 춘계학술발표대회 논문집
    • /
    • pp.232-236
    • /
    • 2004
  • The fracture characteristics of unidirectional composite single-lap bonded joints were investigated experimentally and numerically. The effects of bonding method, surface roughness, bondline thickness and the existence of fillet on the failure characteristics and strength of bonded single-lap joints were evaluated experimentally. The failure process, failure mode and the behavior of load-displacement curve was apparently different according to bonding method. The failure load of the specimen co-cured without adhesive was definitely superior to other types of specimens but the specimens co-cured with adhesive film had a less strength than secondary bonded specimens. In the secondary bonded specimens, the lower value of surface roughness and existence of fillet improved the strength of specimens. The strain energy release rates calculated by geometric nonlinear finite element analyses and Virtual Crack Closure Technique for the secondary bonded specimens considering the three types of initial cracks - comer crack, edge crack and delamination crack - were consistent with the test results.

  • PDF

철 접촉재를 이용한 간헐폭기식 활성슬러지 공법에 의한 인의 제거 (Removal Phosphorus Using Iron Contactor by Intermittent Aeration Activated Sludge Process)

  • 이영신;김동민
    • 한국환경보건학회지
    • /
    • 제19권4호
    • /
    • pp.33-37
    • /
    • 1993
  • The problem for the removal of phosphorus increased due to reasons like eutrophication control. However its removal and operating criteria were not well developed. This study was made for enhanced removal of P by iron contactor by intermittent aeration activated sludge process. Experiment was conducted to find the effects of organic substance load and HRT, nutrient removal efficiency. When applied organic substance load and HRT, II &III reactor were good treatment efficient while come from Fe of iron contactor. Release of phophorus from II &III reactor sludge under anaerobic condition was low. As the process developed, the content of released ionized Fe from iron contactor increased. In addition, the rate of phosphorus removal became accelerating, and the removed sludge was stabilized in the existence of insoluble status.

  • PDF

빙축열조 내부의 열적유동 특성 해석 (Analysis of Thermal and Flow Characteristic in Ice Storage Tank)

  • 김영인;홍희기;배철호;김영일;윤호식
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.369-376
    • /
    • 1988
  • Among several methods to solve the unbalanced electric power load, the Ice Storage System (ISS) for the air conditioning is relatively easy to realize and gives big effect on balancing the electric power load. The goals of this study are to develop the practical ISS for the air conditioning through the design, manufacturing and performance test of the experimental ISS (size $0.335m^3$, cold storage capacity 14200 kcal, IPF 0.4). Thermal fluid motion inside the ice storage tank during cooling storage and cooling release are studied. The data are analyzed by the dispersion analysis and optimal design conditions are derived from the result.

  • PDF

미끄러짐 모드에서의 경량 재료를 이용한 이중외팔보 시험편의 파손 특성 (Fracture Characteristic of Double Cantilever Beam Specimen Using Lightweight Material at Sliding Mode)

  • 김재원;조재웅
    • 한국기계가공학회지
    • /
    • 제20권3호
    • /
    • pp.16-23
    • /
    • 2021
  • The fracture characteristic of the bonded interface under the application of a sliding load to a double cantilevered specimen manufactured using lightweight material was examined. Inhomogeneously bonded materials such as Al6061-T6, CFRP, and CFRP-Al were employed. In the experiment, the specimen was loaded on both directions by applying a shearing load to the bonding interface. The experimentally obtained stress, specific strength and energy release rate values were examined. CFRP exhibited excellent specific strength. The experimental results demonstrated that the inhomogeneous bonded material CFRP-Al exhibited an overall high performance in comparison with the single materials.

연소실 직접분사식 성층급기 가솔린기관 개발에 관한 연구 - 연료분사압력과 부하변동에 따른 연소특성 해석 - (A Study on Stratified Charge GDI Engine Development - Combustion Analysis according to the Variations of Injection Pressure and Load -)

  • 이상만;정영식;채재우
    • 대한기계학회논문집B
    • /
    • 제22권9호
    • /
    • pp.1317-1324
    • /
    • 1998
  • In general, DI gasoline engine has the advantages of higher power output, higher thermal efficiency, higher EGR tolerance and lower emissions due to the operation characteristics of increased volumetric efficiency, compression ratio and ultra-lean combustion scheme. In order to apply the concept of stratified charge into direct injection gasoline engine, some kinds of methodologies have been adapted in various papers. In this study, a reflector was adapted around the injector nozzle to apply the concept of stratified charge combustion which leads the air-fuel mixture to be rich near spark plug. Therefore, the mixture near the spark plug is locally rich to ignite while the lean mixture is wholly introduced into the combustion chamber. The characteristics of combustion is analyzed with the variations of fuel injection pressure and load in a stratified -charge direct injection single cylinder gasoline engine. The obtained results are summarized as follows ; 1. The MBT spark timing approached to TDC with the increase of load on account of the increase of evaporation energy, but has little relation with fuel injection pressure. 2. The stratification effects are apparent with the increase of injection pressure. It is considered by the development of secondary diffusive combustion and the increase of heat release of same region, but proceed rapidly than diesel engine. Especially, in the case of high pressure injection (l70bar) and high load (3.0kgf m), the diffusive combustion parts are developed excessively and results in the decrease of peak pressure than in the case of middle load. 3. The index of engine stability, COVimep value, is drastically decreased with the increase of load. 4. To get better performance of DI gasoline engine development, staged optimizaion must be needed such as injection pressure, reflector, intake swirl, injection timing, chamber shape, ignition system and so on. In this study, the I50bar injection pressure is appeared as the optimum.

원주방향 균열 존재 증기발생기 전열관에 미치는 지지판의 굽힘제한 영향 (Restrained Bending Effect by the Support Plate on the Steam Generator Tube with Circumferential Cracks)

  • 김현수;진태은;김홍덕;정한섭;장윤석;김영진
    • 대한기계학회논문집A
    • /
    • 제31권2호
    • /
    • pp.277-284
    • /
    • 2007
  • The steam generator in a nuclear power plant is a large heat exchanger that uses heat from a reactor to generate steam to drive the turbine generator. Rupture of a steam generator tube can result in release of fission products to environment outside. Therefore, an accurate integrity assessment of the steam generator tubes with cracks is of great importance for maintaining the safety of a nuclear power plant. The steam generator tubes are supported at regular intervals by support plates and rotations of the tubes are restrained. Although it has been reported that the limit load for a circumferential crack is significantly affected by boundary condition of the tube, existing limit load solutions do not consider the restraining effect of support plate correctly. In addition, there are no limit load solutions for circumferential cracks in U-bend region with the effect of the support plate. This paper provides detailed limit load solutions for circumferential cracks in top of tube sheet and the U-bend regions of the steam generator tube with the actual boundary conditions to simulate the restraining effect of the support plate. Such solutions are developed based on three dimensional finite element analyses. The resulting limit load solutions are given in a polynomial form, and thus can be simply used in practical integrity assessment of the steam generator tubes.

Numerical investigation of responses of a piled raft to twin excavations: Role of sand density

  • Karira, Hemu;Kumar, Aneel;Ali, Tauha Hussain;Mangnejo, Dildar Ali;Yaun, Li
    • Geomechanics and Engineering
    • /
    • 제31권1호
    • /
    • pp.53-69
    • /
    • 2022
  • In densely built areas, the development of underground transportation systems often involves twin excavations, which are sometimes unavoidably constructed adjacent to existing piled foundations. Because soil stiffness degrades with induced stress release and shear strain during excavation, it is vital to investigate the piled raft responses to subsequent excavation after the first tunnel in a twin-excavation system. The effects of deep excavations on existing piled foundations have been extensively investigated, but the influence of twin excavations on a piled raft is seldom reported in the literature. In this study, three-dimensional numerical analyses were carried out to investigate the influence of sand density on an existing piled raft (with a working load on top of the raft) due to twin excavations. A wide range of relative density (Dr) from loosest (30%), loose to medium (50% and 70%), and densest (90%) were selected to investigate the effects on settlement and load transfer mechanism of the piled raft during twin excavations. An advanced hypoplastic sand model (which can capture small-strain stiffness and stress-state dependent dilatancy of sand) was adopted. The model parameters are calibrated against centrifuge test results in sand reported in the literature. From the computed results, it is found that twin excavations in loose sand (Dr=30%) caused the most significant settlement. This is because of the higher stiffness of denser sand (Dr=90%) than that of loose sand. In contrast, a much larger tilting (maximum magnitude=0.18%) was computed in dense sand than in loose sand after the completion of the first excavation. As far as the load transfer mechanism along the piles is concerned, an upward load transfer to mobilize shaft resistance is observed in loose sand. On the contrary, a downward load transfer is observed in dense sand.

화물열차 공기제동 완해불량 방지 밸브의 내구성 평가 (Durability Evaluation on the Air-Braking Release Failure Proof Valve of Cargo Train)

  • 이준구;김철수
    • 한국산학기술학회논문지
    • /
    • 제21권9호
    • /
    • pp.32-38
    • /
    • 2020
  • 화차 제동은 공기 제동관의 압력변화를 이용해 제동 체결과 완해를 반복적으로 작동하여 수행한다. 화차 공기 제동 완해 불량은 기관사의 제동완해 취급 후에 제동 제어밸브의 오작동으로 인해 부분적인 제동체결상태를 의미한다. 이 현상은 화차 주행 동안 차륜 찰상과 열손상을 발생시킴으로서, 차륜파손 또는 열차 탈선사고를 일으킨다. 따라서 화차의 운행 지연 및 사고방지를 위해서는 공기제동 완해불량을 방지하는 체계적인 연구가 중요하다. 이를 해결하기 위하여 본 연구에서는 철도운영기관의 제작과 기능요구사항을 고려하여 완해불량 방지밸브를 개발하였다. 또한 본 밸브의 내구성 시험은 화차제동성능 시뮬레이터 성능시험기를 이용하였으며, 이의 작동성능은 반복적인 제동과 완해불량 조건하에 공압이력으로부터 평가하였다. 본 밸브의 보증수명은 화차 주행동안 제동횟수를 고려하여 무고장 시험기법에 준하여 12개 시제품에 대하여 총 16만회 성능시험을 수행하였다. 내구성 시험동안 본 밸브의 공압 입력 시간과 출력시간 및 출력속도의 차이는 거의 일정하였다. 본 밸브의 보증수명은 신뢰수준 95%에서 59,860회이며, 화차 대차에 본 밸브를 설치할 경우에 요구조건인 4년간 고장없이 운용될 수 있음을 의미한다.