• Title/Summary/Keyword: Release Device

Search Result 190, Processing Time 0.03 seconds

Functional Verification of Engineering Model of Non-explosive Shockless Holding and Release Mechanism Using Heating Wire Cutting Method (열선 절단 방식을 적용한 비폭발식 무충격 구속분리장치 EM의 기능검증)

  • Oh, Hyun-Ung;Jeon, Su-Hyeon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.5
    • /
    • pp.401-406
    • /
    • 2013
  • Non-explosive shockless holding and release mechanism for a nano class small satellite application has been proposed and investigated. The great advantages of the mechanism are a much lower shock level and larger constraint force than the conventional mechanism using pyro and the heating wire cutting mechanism which has been generally applied to the cube satellite program. To investigate the effectiveness of the mechanism design, EM mechanism was developed and tested to verify the basic function of the mechanism. The test results indicate that the proposed mechanism is well functioning as the mechanism design intends.

Preparation of Glutamic Acid-Leucine Copolymer Containing Indomethacin for Controlled Delivery

  • Yeom, Young-Il;Kim, Hyun-Pyo;Kim, Hack-Joo;Byun, Si-Myung;Kim, Nam-Deuk
    • Bulletin of the Korean Chemical Society
    • /
    • v.7 no.3
    • /
    • pp.213-217
    • /
    • 1986
  • A series of copolypeptides of glutamic acid and leucine have been synthesized by N-carboxy-${\alpha}$-amino acid anhydride procedure and cast to form injectable microparticulate monolithic devices in which indomethacin was physically dispersed. With these devices, various release properties and possible clinical application were studied. The release rate of the drug had a close relationship with the monomer composition of the copolymer matrix as well as the environmental pH condition. The monolithic device of glutamic acid/leucine = 50/50 was found to be the most promising one as a ploymeric delivery system of indomethacin. The intrinsic viscosity of this copolymer was 4.35 dl/g and the release rate was 18.5${\mu}g/g/day$.

Successful repair of coracoid and femur fractures in a Eurasian eagle owl (Bubo bubo) and its post-release survival

  • Hee-Jong Kim;Kyoo-Tae Kim
    • Journal of Veterinary Science
    • /
    • v.24 no.1
    • /
    • pp.17.1-17.9
    • /
    • 2023
  • To our knowledge, this is the first case of concurrent diaphyseal left coracoid and left femoral fractures in a Eurasian eagle owl and its post-release survival in Korea. The femur was surgically repaired using an external skeletal fixator-intramedullary (IM) pin tie-in method, and the coracoid was repaired solely with an IM pin on day 6 after femur surgery. The eagle owl underwent a gradual rehabilitation process. The bird was successfully rehabilitated and released 101 d after initial presentation. The bird was monitored using a wildlife tracking device and was confirmed to have survived for over 5 mon in the wild.

Development on integrated Pay Off Reel for Varied Diameter of Coil Inner (코일 내경 통합 적용형 PAY OFF REEL 개발)

  • Park, Jeong-Ho;Park, Hyoun-Jin;Lee, Dae-Hee;Kim, Soon-Kyoung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.1
    • /
    • pp.61-66
    • /
    • 2010
  • Pay off reel is the device to release in the form of coil. Every time the device becomes a hassle to exchange, each diameter of two forms has been applied to the coil reel. There is the change of reel diameter of the sleeve portion to be the part of segment geometry. This unit is conducting on 3-dimensional modeling design. The basic strength and deformation of the device could be checked in advance by the basis of 3-d modeling data to perform simulations. The production of each part can be completed and assembled. Conducted for the final product which is tested and measured, all items are satisfied within the limits of targets. Due to the development of this device, the efficiency on operations can be increased and the production time becomes shortened.

Release and Characterization of Multiple Coated Pellets Containing Melatonin (멜라토닌이 함유된 다층 코팅 펠렛의 방출 및 특성분석)

  • Kang, Bok-Ki;Khang, Gil-Son;Kim, Jong-Min;Jeung, Sang-Young;Lee, Hai-Bang;Cho, Sun-Hang
    • Journal of Pharmaceutical Investigation
    • /
    • v.33 no.3
    • /
    • pp.179-185
    • /
    • 2003
  • Melatonin (MT) is an indole amide pineal hormone. It has not only very short half-life but also pH-sensitive property. The sustained release dosage form which delivers MT in a circadian fashion over 8 h is clinical value. The purpose of this study is to prepare sugar beads using multiple coating methods and enteric-coated in a sustained release to evaluate in vitro release characteristics in simulated gastric and intestinal fluids. The $Eudragit^{\circledR}$ as a polymer, sustained release membrane, and triethylcitrate (TEC) as a plasticzer were used. Multi-coated melatonin delivery system was composed of sugar, various excipients, $Eudragit^{\circledR}$ and enteric materials (e.g. hydroxy propyl methyl cellulose phthalate, HPMCP), and prepared by fluid bed coater. The dissolution test was carried out using the basket method at a stirring speed of 100 rpm at $37^{\circ}C$ in simulated gastric (pH 1.2) and intestinal fluid (pH 7.4). The released amount of MT was determined by High performance liquid chromatography method. The morhologies of surface and cross section of multi-coated beads were observed by scanning electron microscope. Size of multi-coated sugar beads was ranged over $1000{\sim}1300\;{\mu}m$. The release rate of MT from coated beads was limited in simulated gastric fluid (pH 1.2), but it was sustained in intestinal fluid (pH 7.4) during $3{\sim}8$ hours. The MT beads may provide small-intestine-targeted device for oral delivery. Studies on animal and relative experiment are in process.

Preparation and Evaluation of Antibacterial Transdermal Device using Chitosan Matrices (키토산 매트릭스를 이용한 향균제 경피흡수제형의 제조와 평가)

  • Kim Sun Il;Na Jae Woon
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.5
    • /
    • pp.527-536
    • /
    • 1993
  • The characteristics of the controlled drug release were studied for biodegradable transdermal drug delivery system. A biodegradable polymeric matrix was prepared from chitosan, silver sulfadiazine, and glycerine. The release behavior of silver sulfadiazine from chitosan matrix was consistent with the Higuchi's diffusion controlled model. The release time was delayed by increasing the content of silver sulfadiazine and thickness of the matrix, whereas decreased as glycerine concentration increased. The apparent constant (K) of release rate was proportional to the content of drug or glycerine and the thickness of chitosan matrix. These results indicated that chitosan matrix shows some potential as a drug delivery system for transdermal therapeutic application.

  • PDF

Evaluation of In Vitro Release Profiles of Fentanyl-Loaded PLGA Oligomer Microspheres

  • Gilson Khang;Seo, Sun-Ah;Park, Hak-Soo;John M. Rhee;Lee, Hai-Bang
    • Macromolecular Research
    • /
    • v.10 no.5
    • /
    • pp.246-252
    • /
    • 2002
  • In order to the development of the delivery device of long-acting local anesthetics for postoperative analgesia and control of chronic pain of cancer patient, fentnyl-loaded poly (L-lactide-co-glycolido) (PLGA, molecular weight, 5,000 g/mole; 50 : 50 mole ratio by lactide to glycolide) microspheres (FMS) were studied. FMS were prepared by an emulsion solvent-evaporation method. The influence of several preparation parameters such as initial drug loading, PLGA concentration, emulsifier concentration, oil phase volume, and fabrication temperature has been investigated on the fentanyl release profiles. Generally, the drug showed the biphasic release patterns, with an initial diffusion followed by a lag period before the onset of the degradation phase, but there was no lag time in our system. Fentanyl was slowly released from FMS over 10 days in vitro with a quasi-zero order property. The release rate increased with increasing drug loading as well as decreasing polymer concentration with relatively small initial burst effect. From the results, FMS may be a good formulation to deliver the anesthetic for the treatment of chronic pain.

Concentration of elemental ions released from non-precious dental casting alloys (치과주조용 비귀금속 합금의 금속 용출 수준)

  • Sakong, Joon;Park, Soo-Chul
    • Journal of Technologic Dentistry
    • /
    • v.35 no.1
    • /
    • pp.1-17
    • /
    • 2013
  • Purpose: This study was to assess the extents of the release of metals from the non-precious alloys used for dental casting by measuring the differences in the extents of the release of metals by types of alloys, pH level and elapsed time. Methods: Uniform-sized specimens(10 each) were prepared according to the Medical Device Standard of the Korea Food and Drug Administration(2010) and International Standard Organization(ISO22674, 2006), using four types of alloys(one type of Ni-Cr and one type of Co-Cr used for fixed prosthesis, and one type of Ni-Cr and one type of Co-Cr used for removable prosthesis). A total of 12 metal-release tests were performed at one-day, three-day, and two-week intervals, for up to 20 weeks. The metal ions were quantified using an Inductively Coupled Plasma-Atomic Emission Spectrometer. Results: The results showed that the extent of corrosion was higher in the ascending order of Jdium-$100^{(R)}$, Bellabond-$Plus^{(R)}$, Starloy-$C^{(R)}$, and Biosil-$F^{(R)}$. The lower the pH and the longer the elapsed time were, the greater the increase in metal corrosion. At pH 2.4, the release of Ni from Jdium-$100^{(R)}$, a Ni-Cr alloy, was up to 15 times greater than the release of Co from the Co-Cr alloy from two weeks over time, indicating that the Ni-Cr alloy is more susceptible to corrosion than the Co-Cr alloy. Conclusion: It is recommended that Co-Cr alloy, which is highly resistant to corrosion, be used for making dental prosthesis with a non-precious alloy for dental casting, and that non-precious alloy prosthesis be designed in such a way as to minimize the area of its oral exposure. For patients with non-precious alloy prostheses, a test of the presence or absence of periodontal tissue inflammation or allergic reaction around the prosthesis should be performed via regular examination, and education on the good management of the prosthesis is needed.

Preparation of Poly(hydroxypropyl methacrylate) Membraney by Sintering Method and Its Permeation Characteristics (소결공정에 의한 Poly(hydroxypropyl methacrylate) Membrane 제조와 그의 투과특성에 관한 연구)

  • Shim, Jyong-Sup;Lee, Dong-Kweon;Hong, Jae-Min
    • Applied Chemistry for Engineering
    • /
    • v.1 no.2
    • /
    • pp.147-153
    • /
    • 1990
  • Poly(hydroxypropyl methacrylate) membranes and matrix devices having tertiary amine moiety were prepared by sintering method, and their permeation characteristics were investigated. The water content of this membrane was increased with decreasing the pH of the medium. The permeability of this membrane was increased with decreasing the sintering pressure. Using sintered matrix device 'burst effect' was found at the early stage, and initial insulin release of glucose oxidase immobilized matrix device could be controlled by glucose concentration of the solution.

  • PDF

A study on the optical characteristics of selenium thin film (Selenium박막의 광학적 특성연구)

  • 허창수;오영주
    • Electrical & Electronic Materials
    • /
    • v.9 no.1
    • /
    • pp.44-50
    • /
    • 1996
  • In this study, Selenium device was fabricated by vacuum evaporation method with the substrate temperature at room temperature and its electrical and optical properties were investigated to be used in optical device. The film properties largely depended on the transmittance and annealing time, and improved with aging owing to stress release. We found that the photocurrent of the films increase linearly with light illumination. As a result, Selenium device made by this method yielded a short circuit current density of 10.5mA/$\textrm{cm}^2$, an open circuit voltage of 39OmV.

  • PDF