• Title/Summary/Keyword: Release Device

Search Result 190, Processing Time 0.032 seconds

A Study on Improvement of Submarine Torpedo Acoustic Counter Measure Launcher System Safety Device Performance (잠수함용 어뢰기만기 발사체계 안전장치 작동성능 향상에 관한 연구)

  • Chang, Ho-Seong;Seo, Dae-Su;Lee, Gyeong-Chan;Lee, Jong-Gwan;Jo, Byeong-Gi;Kim, Joong-Bae
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.3
    • /
    • pp.411-424
    • /
    • 2018
  • Purpose: The purpose of this study is to improve submarine TACM launcher system safety device performance. Methods: In this study, EPLD(Electrically Programmable Logic Device) control and time sharing method to the safety device actuator motor and discrete signal processor in launch control panel were used to resolve unusual performance of safety system. Results: The result of this study are as follows; First, sporadic stopping of safety device actuator motor due to insufficient In-Rush current was resolved. Second, repeat of safety device condition as lock & release due to chattering for motor activating was resolved. Third, simultaneous release function for safety device actuator was available. Conclusion: The unusual performance of function for submarine TACM launcher system was overcame by applying EPLD control and time sharing method. The suggestions were proved by performance test in the pressure chamber. The results of this study enhanced survivability of ${\bigcirc}{\bigcirc}{\bigcirc}$ class submarine from enemy torpedo.

Software Release Management System : ThinkSync DM-SoftMan for Wireless Device based on OMA DM (OMA DM 기반의 무선 단말기 소프트웨어 배포 관리 시스템 ThinkSync DM-SoftMan 개발)

  • Ju, Hong-Taek;Park, Kee-Hyun;Bang, Dae-Wook
    • The KIPS Transactions:PartC
    • /
    • v.13C no.5 s.108
    • /
    • pp.641-650
    • /
    • 2006
  • There has been a continued increase in the complexity of software equipped with wireless mobile devices, due to the introduction of new device functionality and services via network connection. The increasement expected to be accelerated by convergence of telecommunication and broadcasting, and proliferation of telematics and home networking services using wireless mobile devices. The higher the complexity of mobile device software, the higher the necessity of management for the software. As for the global standard of mobile device management technology, OMA DM has been widely adopted by device manufacture and expected to be accelerated its adoption. In this paper, we present a development result of mobile device software release management system ThinkSync DM SoftMan. The implementation details of ThinkSync DM SoftMan are provided in implementation architecture and its working scenario based on the design of ThinkSync DM SoftMan that is summarized in this paper as our previous work. The conformance and performance test of the system are presented.

Effect of Surfactants on the Controlled Release of Bupivacaine HCl from Biodegradable Microfluidic Devices (생분해성 마이크로 유체 약물전달장치의 Bupivacaine HCl 전달특성에 대한 계면활성제의 영향)

  • Yang, Sung-Yeun;Lee, Kang-Ju;Ryu, Won-Hyoung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.5
    • /
    • pp.545-551
    • /
    • 2012
  • We investigated the diffusive transport of bupivacaine HCl through the microchannels of microfluidic drug delivery devices. In the biodegradable microfluidic drug delivery devices developed in this research, the drug release rate can be controlled by simply modulating the geometrical parameters of the microchannels, such as the length, number, and cross-sectional area of the microchannels, when the microchannels are used as paths for drug release. However, the hydrophobic nature of a biodegradable polymer, 85/15 poly(lactic-co-glycolic acid), hinders the infiltration of a release medium (phosphate-buffered saline) through the microchannels into the reservoir of a device that contains bupivacaine HCl, at the early stage of drug release. This can have an adverse effect on the early stage release of local analgesic compounds from the device. In this study, microfluidic channels were surface-treated with surfactants such as PEG600 and Tween80, and the effects of the surfactants on the release performance are presented and analyzed.

Operation and Result Analysis of Hydraulic Vehicle Holding Device (발사체 지상고정장치 유압시스템 작동 시험 및 결과 분석)

  • Kim, Dae Rae;Yang, Seong Pil;Lee, Jae Jun;Song, Oh-Seob;Lee, Young-Shin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.1
    • /
    • pp.80-88
    • /
    • 2018
  • The function of a vehicle holding device (VHD) is to securely hold a launch vehicle on the launch pad and release the launch vehicle at maximum thrust after engine ignition to allow lift-off of the launch vehicle. During the release of the launch vehicle, to prevent the Ka doing a doing a doing mode, which is the vertical oscillation of the entire liquid propellant, the release of the launch vehicle should be gradual. In this study, for the gradual release of a launch vehicle, a hydraulic system comprising an accumulator and pyro valve to operate a hydraulic cylinder and control the speed of the cylinder with an orifice is introduced. Through a test, the influence of design variables on the cylinder speed is analyzed. Based on this, the design values of the hydraulic cylinder are determined. Through this study, the engineering basis for developing a VHD releasing a launch vehicle at maximum thrust is provided.

Heparin Release from Polyurethane-Polyethylene Oxide-Polypropylene Oxide Device (폴리우레탄-폴리에칠렌옥사이드-폴리프로필렌옥사이드-디바이스로부터의 헤파린 방출)

  • Yoo, Jae-Gwon;Jun, Sung-Joo;Kim, Sung-Ho
    • Journal of Pharmaceutical Investigation
    • /
    • v.18 no.4
    • /
    • pp.169-174
    • /
    • 1988
  • The release of heparin from monolithic devices composed of different ratios of polyethylene oxide-polypropylene oxide (PEO-PPO) and hydrophobic polyurethane was investigated. The release rate of heparin could be controlled by varying the PEO-PPO content. The heparin release rate from the devices increased as the content of PEO-PPO in the devices increased. The release mechanism may be associated with creation of micro-channels and pores through the devices following the change in the physical structure of the polymer network. Hydrophobic polyurethane containing PEO-PPO can provide an antithrombogenic material for prolonged release of heparin from a heparin blended system.

  • PDF

Simulation Analysis of Part Release Algorithm under Dynamic Tool Allocation in SSMS (SSMS에서 동적 공구할당을 고려한 부품투입 알고리즘의 시뮬레이션 분석)

  • 이충수
    • Journal of the Korea Society for Simulation
    • /
    • v.8 no.1
    • /
    • pp.63-76
    • /
    • 1999
  • Recently in manufacturing environment, manufacturing order is characterized by unstable market demand, shorter product life cycle, a variety of product and shorter production lead time. In order to adapt this manufacturing order, flexible manufacturing systems(FMS) in manufacturing technology advances into the direction that machines become further versatile functionally and that tools are controlled by fast tool delivery device. Unlike conventional FMS to mainly focus on part flow, it is important to control tool flow in single-stage multimachine systems(SSMS), consisting of versatile machines and fast tool delivery device. This research is motivated by the thought that exact estimation of tool competition at part release in SSMS enhances the system performance. In this paper, in SSMS under dynamic tool allocation strategy to share tools among machines, we propose real-time part release and tool allocation algorithms which can apply real factory and which can improve system performance.

  • PDF

Studies on Dosage Form Design of Anticancer Drug: Release of 5-Fluorouracil from Silicone Devices Containing Water Soluble Additives (항암제(然癌劑) 제형(劑形) 개발(開發)에 관(關)한 연구(硏究) : Silicone Rubber-수용성(水溶性) 첨가제(添加劑)의 Device에서 5-Fluorouracil의 용출(溶出))

  • Kim, Sung-Ho;Choi, Jun-Shik;Back, Chae-Sun;Yu, Young-Jong;Lee, Chi-Young
    • Journal of Pharmaceutical Investigation
    • /
    • v.16 no.1
    • /
    • pp.1-7
    • /
    • 1986
  • The influences of sodium chloride, polyethylene glycol 4000 and 20000 on 5-fluorouracil release from disk type silicone polymer devices were examined in isotonic phosphate buffer. These water soluble cosolvent and sodium chloride caused devices to swell in aqueous media. Sodium chloride exerted the greatest influence on drug release. The addition of water soluble cosolvent or sodium chloride to silicone polymeric devices permitted controlled release of 5-fluorouracil, presumably due to the change of the physical microstructure of silicone network, and the solubility and diffusivity of 5-fluorouracil. It seemed that the water soluble drug was released through the hydrophilic pores or pathways formed in the device by the incorporation of a water soluble cosolvent or sodium chloride.

  • PDF

Effect of Hydrophilic-Lipophilic Balance of Drugs on Their Release Behavior from Amphiphilic Matrix

  • Yoo, Young-Tai;Shin, Hyun-Woo;Nam, Byung-Guk
    • Macromolecular Research
    • /
    • v.11 no.4
    • /
    • pp.283-290
    • /
    • 2003
  • Organic drugs including aspirin, omeprazole, and naproxen with three different levels of octanol/water partition coefficient were examined for their release behavior from the amphiphilic PCL-b-PEO-b-PCL (PCEC) matrix. Scanning electron micrograph (SEM) of PCEC illustrated a well defined two-phase morphology consisted of dispersed poly(ethylene oxide) (PEO) domain and continuous polycaprolactone (PCL) phase. Differential scanning calorimetry (DSC) and X-ray diffractometry (XRD) experiments veri tied that three model drugs are dissolved as a molecular dispersion in PCEC matrix. The release of hydrophilic aspirin closely followed the water absorption profile of the matrix indicating that its major fraction is present in PEO domain. However, substantial amount of aspirin present in less hydrophilic region displayed discontinuous biphasic release pattern. In the case of omeprazole with intermediate hydrophobicity consistent release behavior was observed for a period of 24 hrs after the rapid liberation of ca. 10% of the drug presumably partitioned in PEO phase. It was ascribed to the fact that the progressive hydration of PCEC matrix gradually increased the chance of drug/water exposure to compensate the exhaustion of device. Naproxen with the highest octanol/water distribution coefficient among three model drugs exhibited a limited release of 35% for 24 hrs. Finally, hydroxypropyl methylcellulose phthalate (HPMCP)/PCEC blend matrix demonstrated an accelerated and quantitative release of hydrophobic naproxen by generating high porosity and thereby expanding polymer/water interface.

A comparison of chlorhexidine release rate from three polymeric controlled release drug prototypes (제어방출형 소독제의 약물전달 체로 사용된 폴리머 유형에 따른 클로르헥시딘 제어 방출속도 비교)

  • Bok Young-Bin;Lee Doug-Youn;Lee Chang-Young;Kim Kyung-Nam;Kum Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.6
    • /
    • pp.548-552
    • /
    • 2004
  • Intracanal disinfection of infected root canal is one of important treatment procedure. This in vitro study aimed to evaluate whether the surface polymers of controlled release drug (CRD) can effectively control the release rate of chlorhexidine for root canal disinfection. Four CRD prototypes were prepared: Group A (n=12); The core device (absorbent paper point) was loaded with 40% CHX solution as control. Group B (n=12); same as group A, but the device was coated with chitosan. Group C (n=12); same as group A and then coated three times with 5% PMMA. Group D (n=12); same as group A and then coated three times with 3% PLGA. All CRD prototypes were soaked in 3 mL distilled water for experimental periods and the concentrations of released CHX from each CRD prototype were determined using a UV spectrophotometer. Results showed that release rate of CHX were the greatest in the non-coated group (control group), followed by the chitosan-coated group, the PLGA-coated group, and the PMMA-coated group (P < 0.05). This data indicate that surface polymers can control the release rate of CHX from the CRD prototypes.

Development of Flight Model of Segmented Nut Type Holding and Release Mechanism Using Burn Wire Cutting Method for On-orbit Verification (열선절단형 분리너트식 구속분리장치의 궤도검증을 위한 비행모델 개발)

  • Lee, Myeong-Jae;Lee, Yong-Keun;Kang, Suk-Joo;Oh, Hyun-Ung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.911-915
    • /
    • 2014
  • Pyrotechnic devices are widely used for space appendages. However, a cube satellite requirements do not permit the use of explosive pyrotechnic device. A nichrome burn wire release has typically been used for holding and release of deployable appendages of the cube satellite due to its simplicity and low cost. However, relatively low mechanical constraint force and system complexity for application of multi-deployable systems are disadvantages of the conventional mechanism. To overcome these drawbacks, we have developed a segmented nut type holding and release mechanism based on the nichrome burn wire release. The great advantages of the mechanism are much lower shock level and larger constraint force than the conventional mechanism using pyro. Flight model for on-orbit verification was developed and verified through release function test, vibration test and thermal vacuum test.

  • PDF