• Title/Summary/Keyword: Release Device

Search Result 191, Processing Time 0.024 seconds

Heat dissipation of Al2O3 Insulation layer Prepared by Anodizing Process for Metal PCB (Metal PCB에 있어서 양극산화법으로 제작한 Al2O3절연막의 방열특성)

  • Jo, Jae-Seung;Kim, Jeong-Ho;Ko, Sang-Won;Lim, Sil-Mook
    • Journal of the Korean institute of surface engineering
    • /
    • v.48 no.2
    • /
    • pp.33-37
    • /
    • 2015
  • High efficiency LED device is being concerned due to its high heat loss, and such heat loss will cause a shorter lifespan and lower efficiency. Since there is a demand for the materials that can release heat quickly into the external air, the organic insulating layer was required to be replaced with high thermal conductive materials such as metal or ceramics. Through anodizing the upper layer of Al, the Breakdown Voltage of 3kV was obtained by using an uniform thickness of $60{\mu}M$ aluminum oxide($Al_2O_3$) and was carried out to determine the optimum process conditions when thermal cracking does not occur. Two Ni layers were formed above the layer of $Al_2O_3$ by sputtering deposition and electroplating process, and saccharin was added for the purpose of minimizing the remain stress in electroplating process. The results presented that the 3-layer film including the Ni layer has an adhesive force of 10N and the thermal conductivity for heat dissipation is achieved by 150W/mK level, and leads to improvement about 7 times or above in thermal conductivity, as opposed to the organic insulation layer.

Analysis and Study for the Technical Direction of Internet of Things (IoT) in the Perspective of the Vehicle with Vehicle-Home IoT Service Cases (차량과 홈 IoT 기기 연동 서비스 사례를 통한 차량 측면에서의 IoT 기술 방향성 분석 및 고찰)

  • Kim, Joon-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.1
    • /
    • pp.53-60
    • /
    • 2020
  • With the major advancement of vehicle-related technologies and services, the demands for the in/out-vehicle service expansion increase significantly. The key importance of the service expansion is to provide various vehicle-centric services in addition to improve the convenience and usability of users with connectivity. Recently, Internet of Things (IoT) gains major attention for small device connectivity and service, and it widens its area to other industries including automotive to advance and diversify its services. In this paper, we investigated the technical direction of the IoT service with the analysis of IoT technologies in the perspective of the vehicle. At first, we analyzed the vehicle and IoT services in each so that we are able to suggest the service design guideline and consideration to release integrated services between vehicle and IoT. Also, we reviewed the cases of few vehicle and home IoT integration services for the major insights and future direction of the integration services.

Development of Thermal Image System Based Multi-Core Image Processor (멀티코어 이미지 프로세서 기반 열화상 이미지 시스템 개발)

  • Cha, Jeong Woo;Han, Joon Hwan;Park, Chan;Kim, Young Jin
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.9 no.2
    • /
    • pp.25-30
    • /
    • 2020
  • The thermal image system was widely used in the defence-related industry because of detect infrared light from the object without light. but, as the demand in the security system and automobile market increases, the civilian industry are expanding to the private sector. There are difficult to apply various requirement because of previous systems are based by FPGA, so it need new system that apply to various requirement. The proposed paper is thermal image processing system using common image processor. It has various requirement and scalable to support image input/output interface and device driver. If it is used to proposed system, it reduce development cost and period than previous system based FPGA. Because there has very high accessibility. In addition, it expect to have satisfaction of customer requirements, development cost, development period, release date of product.

Development of De-orbiter using Drag-sail (가항력돛을 이용한 궤도이탈장치 개발)

  • Choi, Junwoo;Kim, Si-on;Lee, Joowan;Yun, Tae-gook;Kim, Byungkyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.1
    • /
    • pp.63-70
    • /
    • 2017
  • In this paper, we design and fabricate a de-orbiter using drag-sail and evaluate deployment characteristics. Without employing an actuator to deploy, the de-orbiter is activated by the SMA wire based the release mechanism and driven by the restoring force of the tape-spring. For efficient storage and deployment of drag-sail, an origami method of original ISO flasher is chosen and low priced mylar film is used as the material of the drag-sail. In addition, through the fault tree analysis method which is one of the one-shot device reliability evaluation methods, we confirm the reliability of the de-orbiter(0.997572) and the Roller failure has the highest criticality. Finally, we find feasibility of the proposed de-orbiter through the deployment demonstration of drag-sail.

MARGINAL FITNESS OF PORCELAIN-FUSED-TO-METAL CROWN ACCORDING TO MATERIAL AND TECHNIQUE

  • Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.120-132
    • /
    • 1998
  • This stusy was to investigate the marginal fitness of porcelain-fused-to- metal crown after succesive firing cycle. Main variables were the degree of marginal curvature of labiocervical margin and the type of alloy. The exaggerated marginal curvature(EMC) was created by additional reduction at the faciocervical wall of the normallized marginal curvature (NMC)-typed ivorine tooth by using milling machine. The difference in the shape was the mid facial margin was placed 2mm apical to cemento- enamel junction in labial surface. Three types of alloy were high noble, noble, and base metal alloy. Test specimens were divided into 8 groups and each group had 8 specimens. Sixty four ceramometal crowns were made totally. Measurement stages were following degassing, opaquing. body porcelain firing, and glazing, and measuring sites were 4. (midmesial, midfacial, middistal, and midlingual). Digital, travelling measuring microscope (0.5 um precision, Olympus. Japan) was used under ${\times}250$ magnification. Within the limitation of this investigation, it was concluded as belows: 1. The pattern of marginal distortion was varied. Degassing stage was not a specific, causative stage that induce most of total marginal distortion during whole procedure fabricating a ceramometal crown. Body firing stage induced discrepancy relatively more than other firing stages. 2. The specimens that were Ni-based alloy and had EMC were distorted persistently following successive fabricating procedures. But marginal openings were decreased after glazing. 3. The release of metal grinding-induced stress was presumed as a cause that induce marginal distortion. 4. The amount of discrepancies of the labial and lingual margins were greater than that of the mesial and distal margin in the specimen that had EMC. 5. Silver-plated die was not enough to resist abrasion during repeated seating of metal copings on the die-holding device.

  • PDF

Thermal Emission Effect of Electronic Parts Using Carbon Materials (탄소물질을 이용한 전자부품의 열 방출효과)

  • Eom, Woon-Yong;Roh, Jae-Seung;Seo, Seung-Kuk;Ahn, Jai-Sang;Kang, Dong-Su;Kim, Suk-Hwan
    • Korean Journal of Materials Research
    • /
    • v.20 no.4
    • /
    • pp.204-209
    • /
    • 2010
  • Recent high efficiency electronic devices have been found to have heat emission problems. As for LEDs, an excessive increase in the device temperature causes a drop of the luminous efficiency and circuit lifetime. Therefore, heat release in the limited space of such electronic parts is very important. This is a study of the possibility of using a coating of carbon materials as a solution for the thermal emission problem of electronic devices. Powdered carbon materials, cokes, carbon blacks, amorphous graphite, and natural flakes were coated with an organic binder on an aluminum sheet and the subsequent thermal emissivity was measured with an FT-IR spectrometer and was found to be in the range of $5{\sim}20\;{\mu}m$ at $50^{\circ}C$. The emissivity of the carbon materials coated on the aluminum sheet was shown to be over 0.8 and varied according to carbon type. The maximum thermal emissivity on the carbon black coated-aluminum surface was shown to be 0.877. The emissivity of the anodized aluminum sheets that were used as heat releasing materials of the electronic parts was reported to be in the range of 0.7~0.8. Therefore, the use of a coating of carbon material can be a potential solution that facillitates heat dissipation for electronic parts.

Hydrogel Ocular Inserts for the Treatment of Infectious Bovine Keratoconjunctivitis

  • Ryoo, Je-Phil;Greer, R.T.;Rosenbusch, R.F.
    • Journal of Pharmaceutical Investigation
    • /
    • v.22 no.3
    • /
    • pp.35-47
    • /
    • 1992
  • Hydrogel coated ring shaped ocular inserts (containing the antibiotic, tylosin tartrate) were used in an evaluation of the effectiveness of polymeric ocular drug release devices for treating infectious bovine keratoconjunctivitis. The in vivo experiments represent the first experiments using hydrogel ocular inserts containing an antibiotic for treating infectious bovine keratoconjunctivitis. In the infection tests, ten calves. were challenged with $2.4{\times}10^8{\sim}1.6{\times}10^9$ Moraxella bovis (a bacterium) colonies per eye following two ten minute ultraviolet radiation eye preconditioning exposures. Ninety five percent of the eyes (19 of 20 eyes) were successfully infected by this method. All infected eyes were monitored for the presence of the bacteria quantitiatively, and clinical observations were made for 14 days. The test was performed by three consecutive steps: 1) inoculation with 2 ultraviolet (UV) radiations, 2) growth of bacterial colonies and 3) treatment with medicated ring-shaped devices. The first. bacteriological measurements after 2 UV exposures were performed at day 3 of the tests. At day 7 after inoculation of both eyes of a calf with M. bovis, a medicated or a non-medicated ring-shaped device was inserted into each eye of a calf. The eye receiving the non-medicated ring was taken as a control for comparison with the eye that received a medicated ring. During the next 7 day period following a medicated ring insertion, the number of bacteria in the treated eyes dropped dramatically to negligible levels (0 to 30 colony forming units/swab), while the control eyes which received a non-medicated ring still exhibited a relatively high number of bacteria ($10^3\;to\;10^6$ colony forming units/swab). The number of bacteria was significantly reduced by the antibiotic released from the medicated ocular insert.

  • PDF

A Research to Minimizing the Effect of Voltage Disturbances on Sensitive Electrical and Electronic Equipment (민감한 전기전자기기의 전압외란에 대한 영향 최소화 연구)

  • 윤갑구
    • Journal of the Korean Professional Engineers Association
    • /
    • v.19 no.2
    • /
    • pp.10-20
    • /
    • 1986
  • This paper describes a countermeasure of electric utilities and customer equipment in order to minimize an effect of sensitive electrical and electronic equipment on the voltage disturbances. After being studied, some schemes to solve were discovered. Firstly, in the electric utilities, the reduction of frequency and influence of voltage drop's time are not easy to realize because of the standpoint of effect and economy. Secondly, in the customer equipment, there are some equipment to minimize the voltage disturbances, Such as an UPSs, a noise suppressors and a power conditioners. One of them should be established on the computer control and automated systems, the electromagnetic switch of delay-release type should be adopted on the electromagnetic switch, the controlling circuit should be adopted on the variable speed motors which is being considered a countermeasure for a momentary under-voltage drops, the luminaire adhering a instantaneous restrike device should be adopted on the HID lamp. And also, the scheme of extending a setting time of relay on the undervoltage relay and the forming method of sequence which is automatic reclosing at this time of instantaneous suspension of an electric supply have been studied.

  • PDF

A study on the Internal Flow Analysis of Gas Cylinder Cabinet for Specialty Gas of Semiconductor (반도체용 특수가스 공급을 위한 가스캐비닛 내부 유동해석에 관한 연구)

  • Kim, Jung-Duck;Han, Seung-A;Yang, Won-Baek;Rhim, Jong-Guk
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.5
    • /
    • pp.74-81
    • /
    • 2020
  • In general, when manufacturing a semiconductor, a number of hazardous and dangerous substances such as flammability, toxic, and corrosiveness are used. In particular, semiconductors are manufactured using specialty gas in processes such as CVD and etching. The specialty gas is filled in a container in the state of compressed or liquefied gas, and a gas cylinder cabinet is used as a facility for supplying this specialty gas to the semiconductor manufacturing process. When a accident occurs in the gas supply system, gas is released through a pressure release device installed in the gas cylinder to secure the safety of the supply system. In this case, the gas released inside the gas cabinet, there is a risk of leaking to the outside. After that, by analyzing the gas flow in the gas cabinet, it is intended to identify the risk associated with leak and to provide measures to prevent accidents.

Combustion Characteristics of Landfill Gas in Constant Volume Combustion Chamber for Large Displacement Volume Engine (III) - Torch Ignition (1) - (대형기관 모사 정적연소실에서 매립지 가스의 연소특성에 대한 연구 (III) - 토치 점화 (1) -)

  • Kim, Inok;Ohm, Inyong;Kwon, Soon Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.2
    • /
    • pp.125-134
    • /
    • 2015
  • This is the third paper on the combustion characteristics of the landfill gas in a constant volume combustion chamber for a large displacement volume commercial engine. It is the first in this series to discuss the effects of the torch device on combustion. The results show that an optimum orifice ratio exists regardless of the torch volume, and a few adverse effects on the combustion are observed for an excessively small orifice ratio. In addition, the torch ignition decreases the initial burn duration, and the decrease in the heat transfer caused by this decreased duration contributes to an increase in the peak combustion pressure. Finally, the torch mostly plays a positive role in shortening the main burn duration when the combustion condition is worsened by a lower methane fraction. Yet, the torch decreases the initial burn duration rather than the main burn as the methane fraction increases.