• Title/Summary/Keyword: Relay Zone

Search Result 56, Processing Time 0.031 seconds

Enhanced Throughput and QoS Fairness for Two-Hop IEEE 802.16j Relay Networks

  • Kim, Sang-Won;Sung, Won-Jin;Jang, Ju-Wook
    • Journal of Communications and Networks
    • /
    • v.13 no.1
    • /
    • pp.32-42
    • /
    • 2011
  • Frequency reuse among relay stations (RSs) in a down-link access zone is widely adopted for throughput enhancement in IEEE 802.16j relay networks. Since the areas covered by the RSs or the base station (BS) may overlap, some mobile stations (MSs) at the border between two neighboring transmitting stations (RS or BS) using an identical frequency band may suffer severe interference or outage. This co-channel interference within the cell degrades the quality of service (QoS) fairness among the MSs as well as the system throughput. Exclusive use of a frequency band division (orthogonal resource allocation) among RSs can solve this problem but would cause degradation of the system throughput. We observe a trade-off between system throughput and QoS fairness in the previously reported schemes based on frequency reuse. In this paper, we propose a new frequency reuse scheme that achieves high system throughput with a high fairness level in QoS, positioning our scheme far above the trade-off curve formed by previous schemes. We claim that our scheme is beneficial for applications in which a high QoS level is required even for the MSs at the border. Exploiting the features of a directional antenna in the BS, we create a new zone in the frame structure. In the new zone, the RSs can serve the subordinate MSs at the border and prone to interference. In a 3-RS topology, where the RSs are located at points $120^{\circ}$ apart from one another, the throughput and Jain fairness index are 10.64 Mbps and 0.62, respectively. On the other hand, the throughput for the previously reported overlapped and orthogonal allocation schemes is 8.22 Mbps (fairness: 0.48) and 3.99 Mbps (fairness: 0.80), respectively. For a 6-RS topology, our scheme achieves a throughput of 18.38 Mbps with a fairness of 0.68; however, previous schemes with frequency reuse factors of 1, 2, 3, and 6 achieve a throughput of 15.24 Mbps (fairness: 0.53), 12.42 Mbps (fairness: 0.71),8.84 Mbps (fairness: 0.88), and 4.57 Mbps (fairness: 0.88), respectively.

Protectability Evaluation of Distance Relay based on a Probabilistic Method for Transmission Network (오차확률 가반 송전계통 보호계전기 보호도 평가방법 연구)

  • Zhang, Wen-Hao;Choi, Myeon-Song;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.29-30
    • /
    • 2008
  • This paper defines a concept of "protectability" for the performance evaluation of distance relay considering its sensitivity and selectivity. The paper starts from the probabilistic modeling of the errors, and based on this model, a detailed explanation of protectability calculation for each zone of the distance relay is presented. An effect of the Weighting Rate and the Measurement Deviation on the protectability evaluation is also given. By considering this effect, the optimization of relay setting can be realized. The proposed method is applied to a typical model system to show its effectiveness.

  • PDF

Reuse Partitioning for Throughput and Fairness Improvement in OFDMA Based Relay System (OFDMA기반 Relay시스템에서 Throughput과 Fairness성능 향상을 위한 Reuse Partitioning기법)

  • Shim, Min-Kyu;Choi, Ho-Young;Hong, Dae-Hyoung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.9
    • /
    • pp.17-24
    • /
    • 2007
  • In this paper, we propose the sub-cell reuse partitioning among relays as an efficient resource reuse scheme in the relay-based OFDMA systems. If the frequency resource is reused among relays aggressively, we can increase the cell throughput. However, the interferences due to the frequency reuse may cause the fairness decrease due to the SINR degradation especially at the edge of RS sub-cells. In this paper, to make the cell throughput and fairness performance improved at the same time, we propose a sub-cell reuse partitioning scheme that divides a relay sub-cell into inner zone for aggressive reuse and outer zone for sparse reuse. The performance of the proposed scheme has been analyzed by computer simulation. We also applied a scheduling algorithm that can work together with the proposed sub-cell reuse partitioning scheme. Simulation results show that the proposed scheme can improve both the throughput and the fairness performances. In particular, when the scheduling is applied for the improvement of fairness, it is shown that the throughput performance can be enhanced more efficiently by the proposed scheme.

Improved Coordination Method for Back-up Protection Schemes Based on IEC 61850 (IEC 61850 기반 후비보호계전시스템 보호협조 개선방안)

  • Kim, Hyung-Kyu;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.43-49
    • /
    • 2011
  • A distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, Zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome this problem clearly, this paper describes an improved backup protection coordination scheme using an IEC 61850-based distance relay for transformer backup protection. IEC 61850-based IED(Intelligent Electronic Device) and the network system based on the kernel 2.6 LINUX are realized to verify the proposed method. And laboratory tests to estimate the communication time show that the proposed coordination method is reliable enough for the improved backup protection scheme.

Design and Evaluation of a Protection Relay for a Wind Generator Based on the Positive- and Negative-Sequence Fault Components

  • Zheng, Taiying;Cha, Seung-Tae;Kim, Yeon-Hee;Crossley, Peter A.;Lee, Sang Ho;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1029-1039
    • /
    • 2013
  • To avoid undesirable disconnection of healthy wind generators (WGs) or a wind power plant, a WG protection relay should discriminate among faults, so that it can operate instantaneously for WG, connected feeder or connection bus faults, it can operate after a delay for inter-tie or grid faults, and it can avoid operating for parallel WG or adjacent feeder faults. A WG protection relay based on the positive- and negative-sequence fault components is proposed in the paper. At stage 1, the proposed relay uses the magnitude of the positive-sequence component in the fault current to distinguish faults requiring non-operation response from those requiring instantaneous or delayed operation responses. At stage 2, the fault type is first determined using the relationships between the positive- and negative-sequence fault components. Then, the relay differentiates between instantaneous operation and delayed operation based on the magnitude of the positive-sequence fault component. Various fault scenarios involving changes in position and type of fault and faulted phases are used to verify the performance of the relay. This paper concludes by implementing the relay on a hardware platform based on a digital signal processor. Results indicate that the relay can successfully distinguish the need for instantaneous, delayed, or non-operation.

An Improvement of Distance Relay Technique Reliability using Elman Network (Elman Network를 이용한 거리계전기법의 신뢰성 향상)

  • Jung, H.S.;Lee, J.J.;Shin, M.C.;Lee, B.K.;Park, C.W.;Jang, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.212-214
    • /
    • 2000
  • The distance relay technique used for transmission line protection operates overreach and underreach to the self protection region because the power system becomes complex and fault conditions are different. To solve these problems, this paper describes new technique to set the reliable self protection lesion. The trip region of the quadrilateral distance relay is set by training of multi layer recurrent elman network. The proposed network is able to reach the trip zone for the fault impedance, fault initial angle and source impedance variance correctly.

  • PDF

Analysis of Catenary impedance characteristics in the extended power feeding conditions of AC traction system (교류급전방식에서의 연장급전에 따른 선로임피던스 특성 분석)

  • Jung, Hosung;Kim, Joorak;Chang, Sanghoon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1617-1618
    • /
    • 2015
  • This paper analyzed catenary impedance characteristics of relays installed in substation and sectioning post to protect power feeding circuit in the extended power feeding conditions. For this, we modelled AT feeding system using PSCAD/EMTDC and calculated catenary impedance. The relay installed in substation calculated catenary impedance of the extended power feeding area adding catenary impedance of self protection zone. But, the relay installed in sectioning post calculated catenary impedance of the only protection area. Therefore, we confirmed that the more reliable protection way can be utilized using the relay installed in sectioning post.

  • PDF

A Study on Operation Zone of Adaptive Distance Relay on Transmission Line Connected UPFC Between Kangjin and Jangheung (UPFC가 연계 된 강진-장흥 송전선로 보호용 거리계전기의 동작특성에 관한 연구)

  • Lee, Seung-Hyuk;Jung, Chang-Ho;Kim, Jin-O;Jung, Hyun-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.305-307
    • /
    • 2003
  • This paper presents an apparent impedance calculation procedure for distance relaying of transmission line involving FACTS (Flexible AC Transmission System) devices, particularly the UPFC (Unified Power Flow Controller), between Kangjin and Jangheung in Korea. With the changes of UPFC's parameters, the measurement and protective range (trip boundaries) of the adaptive distance relay can also be changed. So, it is the most important part in the field of system protection to analyze the operating characteristic of relaying system. The presence of UPFC significantly affects the trip boundaries which are also adversely affected by fault resistance combined with remote end infeed. This paper presents the apparent impedance calculations and the distance relay setting characteristics for faults involving the UPFC in the KEPCO system.

  • PDF

Improving Motor Protection Using Thermal Model (열 모델을 이용한 전동기 보호성능 개선)

  • Chang, Choong-Koo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.473-479
    • /
    • 2015
  • Thermal relays are sometimes used instead of long time overcurrent relays for motor protection. But, it is difficult for any relay design engineer to adequately approximate motor heating curves which represent the average of a difficult-to-define thermal zone. Thermal relays frequently may not provide sufficient protection on heavy overloads. Digital multifunction relays are microprocessor-based devices. These relays offer highly reliable and advanced protection of motors. If a situation can be mathematically described, the microprocessor in a digital relay can be programmed to tackle that problem. Today's motor protection is accomplished with digital protective relays. Digital relays offer additional, highly important features to complement protection. The best way to prevent short in motor is to not overheat and degrade the insulation.

A Study on Adaptive Distance Protection of Double-circuit Line with Mutual Impedance and Fault Resistance (2회선 송전선로에서 상호임피던스와 고장저항을 고려한 거리계전기의 동작 특성 연구)

  • 이원석;정창호;김진오
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.4
    • /
    • pp.221-226
    • /
    • 2004
  • Power system has recently used Double-circuit Line and Multi-circuit Line in the industrial development. This has an advantage of system stability and reliability, but the complexity of the system has a disadvantage that makes it difficult to protect the power line. Double-circuit Line has two operation conditions in the Single-circuit operation and Double-circuit operation, so it has mutual impedance. To make it possible for the remaining single-line to operate independently while there is a fault with first line or when maintenance is needed, a trip region for the single-circuit operation should be set in order to set the relay trip region. An optimal trip region for each operation, a different operational conditions for the relay setting should be calculated. In this paper, trip regions of each operation condition have been compared by considering mutual impedance and fault resistance that led to the calculation of fault impedance. Also, as we know that one of the advantages in the distance relay is the back-up protection, we calculated the trip region(Zone-2) in consideration of the mutual impedance.