• 제목/요약/키워드: Relaxation time measurement

검색결과 70건 처리시간 0.026초

고체유전체의 쌍극자분극 완화시간 측정에 의한 유전특성의 연구 (A study on the dielectric properties by measurement of relaxation time of dipole polarization in solid dielectrics)

  • 박중순;서장수;김병인;국상훈
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1992년도 춘계학술대회 논문집
    • /
    • pp.125-129
    • /
    • 1992
  • When relaxation time will be distributed, TSC observed in the experimental procedure was analysed by using a potential model having two equilibrium positions and equations of dielectric properties was derived. Calculation of distribution was made by matrix method and compared/confirmed values obtained by TSC and alternating current which have a correspondence with each other. In this measurement, distribution of activation energy and relaxation time was determined by TSC peak at around 147k/364 of which center is 10$\^$-4/ sec/10$\^$5/ sec respectively at room temperature and also obtained dielctric loss factor at the range of 10$\^$-7/-10$\^$5/Hz. It seems that low temperature peak is local dispersion and high temperature peak have a relation to dielectric transition of the material.

  • PDF

장쇄지방산 L막의 완화 시간 (Dielectric Relaxation Time of Long Chain Fatty Acid Langmuir films)

  • 전동규;장헌;오재한;강용철;최영일;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.279-282
    • /
    • 2000
  • The displacement current measurement has been employed to study the dielectric properties of Langmuir films. A method for determining the dielectric relaxation time $\tau$ of floating monolayers on water surface is presented. The displacement current flowing across monolayers is analyzed using a rod-like molecular model. It's revealed that the dielectric relaxation time $\tau$ of monolayers in the isotropic polar orientational phase is determined using a liner relationship between the monolayers compression speed $\alpha$ and the molecular maximum area $A_{m}$. The compression speed $\alpha$ was about 30, 40, 50mm/minmm/min

  • PDF

DMPC LB박막의 유전완화현상 (Dielectric Relaxation Phenomena of DMPC LB Thin Film)

  • 최영일;송진원;조수영;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.822-825
    • /
    • 2003
  • Maxwell displacement current (MDC) measurement has been employed to study the dielectric property of Langmuir-films. A method for determining the dielectric relaxation time $\tau$ of floating monolayers on water surface is presented. WC flowing across monolayers is analyzed using a rod-like molecular model. It is revealed that the dielectric relaxation time $\tau$ of monolayers in the isotropic polar orientational phase is determined using a liner relationship between the monolayer compression speed ${\alpha}$ and the molecular area Am. Compression speed ${\alpha}$ was about 30, 40, 50mm/min.

  • PDF

Angular Dispersion-type Nonscanning Fabry-Perot Interferometer Applied to Ethanol-water Mixture

  • Ko, Jae-Hyeon;Kojima, Seiji
    • Journal of the Optical Society of Korea
    • /
    • 제13권2호
    • /
    • pp.261-266
    • /
    • 2009
  • The angular dispersion-type non-scanning Fabry-Perot was applied to an ethanol-water mixture in order to investigate its acoustic properties such as the sound velocity and the absorption coefficient. The scattered light from the mixture was analyzed by using the charge-coupled-device area detector, which made the measurement time much shorter than that obtained by using the conventional scanning tandem multi-pass Fabry-Perot interferometer. The sound velocity showed a deviation from ultrasonic sound velocities at low temperatures accompanied by the increase in the absorption coefficient, indicating acoustic dispersion due to the coupling between the acoustic waves and some relaxation process. Based on a simplified viscoelastic theory, the temperature dependence of the relaxation time was obtained. The addition of water molecules to ethanol reduced the relaxation time, consistent with dielectric measurements. The present study showed that the angular dispersion-type Fabry-Perot interferometer combined with an area detector could be a very powerful tool in the real-time monitoring of the acoustic properties of condensed matter.

Effect of Number of Measurement Points on Accuracy of Muscle T2 Calculations

  • Tawara, Noriyuki;Nishiyama, Atsushi
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권4호
    • /
    • pp.207-214
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the effect of the number of measurement points on the calculation of transverse relaxation time (T2) with a focus on muscle T2. Materials and Methods: This study assumed that muscle T2 was comprised of a single component. Two phantom types were measured, 1 each for long ("phantom") and short T2 ("polyvinyl alcohol gel"). Right calf muscle T2 measurements were conducted in 9 healthy male volunteers using multiple-spin-echo magnetic resonance imaging. For phantoms and muscle (medial gastrocnemius), 5 regions of interests were selected. All region of interest values were expressed as the mean ${\pm}$ standard deviation. The T2 effective signal-ratio characteristics were used as an index to evaluate the magnetic resonance image quality for the calculation of T2 from T2-weighted images. The T2 accuracy was evaluated to determine the T2 reproducibility and the goodness-of-fit from the probability Q. Results: For the phantom and polyvinyl alcohol gel, the standard deviation of the magnetic resonance image signal at each echo time was narrow and mono-exponential, which caused large variations in the muscle T2 decay curves. The T2 effective signal-ratio change varied with T2, with the greatest decreases apparent for a short T2. There were no significant differences in T2 reproducibility when > 3 measurement points were used. There were no significant differences in goodness-of-fit when > 6 measurement points were used. Although the measurement point evaluations were stable when > 3 measurement points were used, calculation of T2 using 4 measurement points had the highest accuracy according to the goodness-of-fit. Even if the number of measurement points was increased, there was little improvement in the probability Q. Conclusion: Four measurement points gave excellent reproducibility and goodness-of-fit when muscle T2 was considered mono-exponential.

Dielectric Relaxation of Siloxane-Epoxy Copolymers

  • Kim, Chy-Hyung;Shin, Jae-Sup
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권3호
    • /
    • pp.413-416
    • /
    • 2002
  • The dielectric responses of 10 and 40 wt% siloxane-epoxy copolymers were investigated in temperature range near the glass transition of polydimethylsiloxane at which the dielectric transitions were also observed. On the other hand, the pure epoxy did not show any dielectric transition in measurement temperature range -90 to 150 $^{\circ}C.$ The experimental data showed that for the copolymer investigated, the temperature-frequency super-position principle could be applied to the dielectric response. From the Cole-Cole equation, the dielectric relaxation of the 10 wt% siloxane near the glass transition temperature resulted in a broad distribution with ${\beta}=$ 0.19 and the relaxation time at -70 $^{\circ}C$ was 5.3 ${\times}$ $10^{-2}$s. The glass transition temperature, 188 K, was estimated by using WLF relation, which was consistent with the data presented in experiment.

Universal time relaxation behavior of the exchange bias in ferromagnetic/antiferromagnetic bilayers

  • Dho Joonghoe
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2005년도 동계학술연구발표회 및 2차 아시안포럼
    • /
    • pp.80-81
    • /
    • 2005
  • The resilience of the exchange bias ($H_{EX}$) in ferromagnet / antiferromagnet bilayers is generally studied in terms of repeated hysteresis loop cycling or by protracted annealing under reversed field (training and long-term relaxation respectively). The stability of $H_{EX}$ is fundamental for practical application of exchange bias systems. In this paper we report measurements of training and relaxation in FeNi films coupled with the antiferromagnet FeMn. We show that $H_{EX}$ suppressed both by training and relaxation was partially recovered as soon as a field cycling for consecutive hysteresis loop measurement was stopped or the magnetization of the ferromagnet was switched back to the biased direction.

  • PDF

Analytical Techniques for Measurement of Crosslink Densities of Rubber Vulcanizates

  • Son, Chae Eun;Choi, Sung-Seen
    • Elastomers and Composites
    • /
    • 제54권3호
    • /
    • pp.209-219
    • /
    • 2019
  • It is important to analyze crosslink densities of rubber articles because the physical properties are dependent on the crosslink densities. In this paper, analytical techniques for the measurement of crosslink densities of rubber vulcanizates are described. The most widely used method to measure the crosslink density is a swelling method combined with the Flory-Rehner equation. Application of the interaction parameter (${\chi}$) of rubber and swelling solvent is critical because the crosslink density is absolutely dependent on the ${\chi}$ value. Methods for obtaining ${\chi}$ employ not only solubility parameters of the polymer and swelling solvent but also inverse gas chromatography (IGC). The solubilities of rubbers can be obtained using micro differential scanning calorimetry (${\mu}DSC$), intrinsic viscosity measurement, and UV-visible spectroscopy. Nuclear magnetic resonance (NMR) spectroscopy has been also used for the measurement of the crosslink density using the $T_2$ relaxation time, which is determined by spin-spin relaxation in solid-state NMR. For sulfur-cured rubber vulcanizates, crosslink densities according to the crosslink types of mono-, di-, and polysulfides are measured by treating the rubber samples with a chemical probe composed of thiol and amine compounds. Measurement methods of physical crosslinking by filler, crystallization, and ionic bonding have also been introduced.

[ $T_2$ ]-relaxation Time Measurement of ex vivo $^1H$ MR Metabolite Peaks for Evaluation of Human Stomach Cancer

  • Mun Chi-Woong;Choi Ki-Sueng;Shin Oon-Jae;Yang Young-Ill;Chang Hee-Kyung;Hu Xiaoping;Eun Chung-Ki
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권2호
    • /
    • pp.53-58
    • /
    • 2006
  • In this study, transverse relaxation time (T2) measurement and the evaluation of the characteristics of the spectral peak related to stomach tissue metabolites were performed using ex vivo proton magnetic resonance spectroscopic imaging (MRSI) at 1.5-T MRI/S instruments. Thirty-two gastric tissues resected from 12 patients during gastric cancer surgery, of which 19 were normal tissue and 13 were cancerous tissue, were used to measure the $T_2$ of the magnetic resonance spectroscopy (MRS) peaks. The volume of interest data results from the MRSI measurements were extracted from the proper muscle (MUS) layer and the composite mucosa/submucosa (MC/SMC) layer and were statistically analyzed. MR spectra were acquired using the chemical shift imaging (CSI) point resolved spectroscopy (CSI-PRESS) technique with the parameters of pulse repetition time (TR) and echo times (TE) TR/(TE1,TE2)=1500 msec/(35 msec, 144 msec), matrix $size=24{\times}24$, NA=1, and voxel $size=2.2{\times}2.2{\times}4mm^3$. In conclusion, the measured $T_2$ of the metabolite peaks, such as choline (3.21ppm) and lipid (1.33ppm), were significantly decreased (p<0.01 and p<0.05, respectively) in the cancerous stomach tissue.

Relaxation of Photogenerated Carriers under He, $H_2, Co_2 and\; O_2$ on ZnO

  • 한종수;김혜정;진준
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권6호
    • /
    • pp.676-680
    • /
    • 1998
  • The relaxation process of photogenerated carriers was investigated using conductivity measurement on ZnO under He, $H_2,\; CO_2\; and\; O_2$. The process was well explained with the rate constant of reaction or recombination of hole and electron, $k_h \;and\; k_e ( k_h > k_e)$, respectively. Generally, $k_h$ increased with the pressure of the gases. The slope of $k_h$ with respect to the pressure increased in the order of $H_2{\le}He, while $k_h$ of $O_2$ was sensitive to the history of the sample. The relaxation process on ZnO which was exposed to oxygen at 298 K and 573 K was observed during the illumination at 298 K and it was found that the rate constant of hole decreased with illumination time. From the result, it was suggested that the rate constant of photogenerated excess carriers was affected by the surface barrier of the semiconductor.