• Title/Summary/Keyword: Relaxation rate

Search Result 459, Processing Time 0.027 seconds

The Effect of Dynamic Strain Aging on the High Temperature Plastic Deformation Behaviour of Al-Mg Alloy (Al-Mg 합금의 고온 소성 변형 특성에 미치는 동적 변형 시효의 영향)

  • 이상용;이정환
    • Transactions of Materials Processing
    • /
    • v.5 no.4
    • /
    • pp.327-336
    • /
    • 1996
  • The effect of dynamic strain aging on high temperature deformation behaviour of the A-Mg alloy was investigated by strain rate change tests and stress relaxation tests between 20$0^{\circ}C$and 50$0^{\circ}C$. Yield point, short stress transient and periodic discontinuities on the stress-strain curve were considered as an evidence of the effect of dynamic strain aging. With this criterion two distinct strain rate-temperature regimes could be manifested. Dynamic strain aging was considered to be effective in the high temperature-low strain rate regime, whereas dynamic recovery was a dominant deformation mechanism in the low temperature-high strain rate regime. It was found that dynamic strain aging in the high temperature deformation was governed by the mechcanism of diffusion-controlled, viscous dislocation movement.

  • PDF

A Study on Elimination Solution of Parasitic Effect to Improve Area Efficiency and Frequency Stability of Relaxation Oscillator (이완 발진기의 면적 효율성과 주파수 안정성 향상을 위한 기생성분 효과 제거 기법연구)

  • Lee, Seung-Woo;Lee, Min-Woong;Kim, Ha-Chul;Cho, Seong-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.4
    • /
    • pp.538-542
    • /
    • 2018
  • In order to generate a clock source with low cost and high performance in system on chip(SoC), a relaxation oscillator with stable output characteristics according to PVT(process, voltage and temperature) fluctuation require a low area and a low power. In this paper, we propose a solution to reduce the current loss caused by parasitic components in the conventional relaxation oscillator. Since the slew rate of the bias current and the capacitor are adjusted to be the same through the proposed solution, a relaxation oscillator with low area characteristics is designed for the same clock source frequency implementation. The proposed circuit is designed using the TSMC CMOS 0.18um process. The Simulation results show that the relaxation oscillator using the proposed solution can prevent the current loss of about $279{\mu}A$ and reduce the total chip area by 20.8% compared with the conventional oscillator in the clock source frequency of 96 MHz.

Effect of Arsenic on Acetylcholine-Induced Relaxation in Blood Vessels in vitro cad in vivo

  • Lee, M.Y.;Chung, S.M.;Bae, O.N.;Chung, J.H.
    • Proceedings of the Korean Society of Food Hygiene and Safety Conference
    • /
    • 2002.05a
    • /
    • pp.137-137
    • /
    • 2002
  • Several epidemiologidal studies suggested that arsenic exposure was strongly correlated with the development of cardiovascular disease such as hypertension. In order to examine whether arsenic affects vasomotor tone in blood vessels, we investigated the effect of arsenic on agonist-induced vasorelaxation using the isolated rat aortic ring in in vitro organ bath system. Treatment with arsenite inhibited acetylcholine-induced relaxation of aortic rings in a concentration- dependent manner. The inhibitory effects by arsenic were also observed in the relaxation induced by sodium nitroprusside, a NO-donor. Consistent with these findings, the cGMP levels stimulated by acetylcholine in blood vessels were reduced significantly by arsenite treatment. In addition, higher concentration of arsenite decreased the relaxation by 8-Br-cGMP, a cGMP analog, in aortic rings without endothelium. These in vitro results indicated that arsenite that arsenite was capable of suppressing acetylcholine-induced relaxation in blood vessels by inhibiting production of nitric oxide in endothelial cells and by impairing the relaxation machinary in smooth muscle cells. In vivo studies revealed that the reduction of blood pressure by acetylcholine infusion was signigicantly suppressed after arsenite was administered intravenously to rate. These data suggest that vasomotor tone impaired by arsenite exposure may be one of the contrbuting factors in development of cardiovascular disease.

  • PDF

The Effects of Relaxation Therapy on Pain and Anxiety in Spinal Anesthesia Surgery Patients (척추마취 수술환자의 불안감소를 위한 이완요법 적용 효과)

  • Moon, Hyeun-Sook;Lee, Hyang-Yeon;Lee, Ji-A
    • Journal of East-West Nursing Research
    • /
    • v.15 no.1
    • /
    • pp.54-62
    • /
    • 2009
  • Purpose: The purpose of this study was to examine the effects of relaxation therapy to reduce anxiety level among spinal anesthesia surgery patients. Methods: The study employed a quasi-experimental pre-and-posttest design with nonequivalent control group. The experimental group was provided with the 15-min muscle relaxation therapy on the day before the surgery and an hour before the spinal anesthesia. Data were collected from 44 patients (22 in experimental and 22 in control group) who were planned to have spinal anesthesia surgery from an orthopedic surgery department at a general hospital in Seoul from January 13 to March 21, 2006. Results: The experimental group reported lower level of state anxiety after the surgery (23.18 vs. 33.64) than did control group but was not statistically significant. There were no significant differences in blood pressure or pulse rate between experimental and control groups after surgery. Conclusions: The further research should be conducted to polish the muscle relaxation therapy for various types of patients and to create more comfortable environment setting for application of the therapy. The muscle relaxation therapy may be a convenient and useful nursing intervention to reduce anxiety among spinal anesthesia surgery patients if more studies prove its effectiveness.

A Study on High Temperature Creep and Stress Relaxation Properties of Zr-4 (Zr-4의 고온 크리프 및 응력이완 특성에 관한 연구)

  • Oh, Sea-Kyoo;Park, Chung-Bae;Han, Sang-Deok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.28 no.1
    • /
    • pp.71-78
    • /
    • 1992
  • Zr-4 used for a cladding and an end plug of reactor component has creep deformation under operation at high temperature. Creep is regarded as the time dependent deformation of a material under constant applied stress. Although the major source of the deformation of zirconium component in water-cooled reactors is irradiation creep, the thermal creep may give a rise to significant deformation in reactor component especially at relatively high temperatures and at various constant stresses, and therefore it must be predicted accurately. Stress relaxation is the time dependent change of stress at constant strain and it is a process related intimately to creep. In this paper, the creep behavior and stress relaxation of Zr-4 is examined at the temperature of 50$0^{\circ}C$ that is 40% of the absolute melting temperature of Zr-4 under the stress below yield stress and under the various constant strains. The results obtained are summarized as follows: 1) With an increase of stress, the steady state creep rate increases and the creep rupture time decreases. 2) The steady state creep rate $\varepsilon$(%/s) for the stress $\sigma$sub(c) (kgf/mm super(2)) of Zr-4 increases outstandingly. All the empirical equations computed for Zr-4 increases outstandingly. All the empirical equations computed for Zr-4 are in accord with Norton's model equation($\varepsilon$=K$\sigma$ sub(c) super (n)). The constants of materials computed are as follows: K=3.9881$\times$10 super(-5), n=1.9608 3) The rupture time T sub(r) (hr) decreases linearly with the increase of stress on the log-log scaled graph. The empirical equations computed for Zr-4 are in accord with Bailey's model equation (T sub(r)=K sub(1)$\sigma$sub(c) super(m)). The constants of materials computed are as follows: K sub(1)=1.2875$\times$10 super(16), m=-3.467 4) It seems clear that the strain could be quantitatively dependent on the high temperature creep properties such as creep stress, rupture time, steady state creep rate and total creep rate. It is found that these relationships are linear on the log-log graph. 5) In stress relaxation test, as the critical constant strain that can be allowed to the specimen is larger, stress relaxation becomes more rapid, and as the constant strain is smaller, the stress relaxation becomes slower.

  • PDF

Development of a SRP(Stress Relaxation Program) Game using HRV(Heart Rate Variability) (심장박동수 변이성을 이용한 스트레스 이완용 게임개발)

  • Choi, Sam-Ha;Joe, Young-Sin;Kim, Kyung-Sik
    • Journal of Korea Game Society
    • /
    • v.2 no.1
    • /
    • pp.77-83
    • /
    • 2002
  • Cases of applying game in the medical area are increasing thesedays. This game has been developed to prevent disease in self-nervous system through the control of respiration after monitoring the mental stress and physical stress from the heart rate variability (HRV) of the game user. The game is a kind of a stress relaxation program (SRP) designed not to avoid boring or rejecting mind of users by traditional simple training of continuous repetition, but to increase interaction which is a unique feature of games.

  • PDF

Pharmacological Actions of New Woohwangchungsimwon Liquid on Cardiovascular System (신우황청심원액의 심혈관계에 관한 약효연구)

  • 조태순;이선미;김낙두;허인회;안형수;박대규
    • Biomolecules & Therapeutics
    • /
    • v.5 no.4
    • /
    • pp.390-401
    • /
    • 1997
  • In order to investigate the pharmacological properties of New Woohwangchungsimwon Liquid (NCL), effects of Woohwangchungsimwon Liquid (CL) and NCL were compared. In isolated rat aorta, NCL and CL showed the relaxation of blood vessels in maximum contractile response to phenylephrine (10$^{-6}$ M) without regard to intact endothelium or denuded rings of the rat aorta. Furthermore, the presences of the inhibitor of NO synthase and guanylate cyclase did not affect the relaxation of NCL and CL. NCL and CL inhibited the vascular contractions induced by acetylcholine, prostaglandin endoperoxide or peroxide in a dose-dependent manner. In conscious spontaneously hypertensive rats (SHRs), NCL and CL significantly decreased heart rate. NCL and CL, at high doses, had a negative inotropic effect that was a decrease of LVDP and (-dp/dt)/(+dp/dt) in the isolated perfused rat hearts, and also decreased the contractile force and heart rate in the isolated rat right atria. In excised guinea-pig papillary muscle, NCL and CL had no effects on parameters of action potential at low doses, whereas inhibited the cardiac contractility at high doses. These results suggested that NCL and CL have weak cardiovascular effects with relaxation of blood vessels and decrease of heart rate, and that this effect is no significant differences between two preparations.

  • PDF

Change of blood pressure end vasorelaxation on EAE-induced lewis rat

  • Bong su Kang;Park, Young shim;In hoi Huh
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1996.04a
    • /
    • pp.194-194
    • /
    • 1996
  • Pathogenesis of experimental allergic encephalomyelitis was involved with infection, inflammatory reaction, immune reaction etc. We studied on relation of blood vessel system and EAE. So, we measured blood pressure, heart rate and relaxation of isolated blood vessel in control and EAE-induced lewis rats. Blood pressure was decreased before EAE clinical sign (0-20day), but was increased from 23day. In isolated blood vessel, acetylcholine-treated relaxation was different on control, maximum EAE stage, recovery stage. Acetylcholine-treated relaxation was reduced 30% in recovery stage. but, sodium nitroprusside had similar relaxation reaction.

  • PDF

A study on the transient electron transport in GaAs bulk (GaAs 벌크에서 전자의 과도 전송 특성)

  • 임행삼;황의성;심재훈;이정일;홍순석
    • Electrical & Electronic Materials
    • /
    • v.10 no.3
    • /
    • pp.268-273
    • /
    • 1997
  • In this paper the transient electron transport in GaAs bulk is simulated by using ensemble Monte Carlo method. To analyze the transient electron transport the 10000 electrons in the .GAMMA. valley are simulated simultaneously for 10 picoseconds. The electric field-velocity relation is obtained. The high impurity density reduces the negative differential resistance effect. The result of transient average velocity shows the electron velocity in the transient state is faster than that in the steady state. This transient velocity overshoot is caused by the intervalley scattering mechanism. And we confirmed the fact that the energy relaxation time is longer than the momentum relaxation time.

  • PDF

The magnetic properties in Bi$_2$Sr$_2$CaCu$_2$O$_8$ single crystal with columnar defects

  • Lee, C.W.;Shim, S.Y.;Ha, D.H.;Kim, D.H.;Lee, T.W.
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.103-106
    • /
    • 2000
  • We have studied the magnetic properties in Bi$_2$Sr$_2$CaCu$_2$O$_8$ single crystal with columnar defects using micro Hall-probe array. We found that fold profiles inside sample were similar to the Bean's critical state model from the magnetic hysteresis measurement. In the magnetic relaxation measurement, the normalized relaxation rates were maximum near the center and decreased toward the edge of the sample expect zero gauss. The relaxation rates as a function of the temperature were maximum near the 40K and rapidly decreased both sides of the peak.

  • PDF