Evaluation of slip coefficient of slip critical joints with high strength bolts

  • Nah, Hwan-Seon;Lee, Hyeon-Ju;Kim, Kang-Seok;Kim, Woo-Bum
    • Structural Engineering and Mechanics
    • /
    • v.32 no.4
    • /
    • pp.477-488
    • /
    • 2009
  • A slip critical joint has various values to adopt the proper slip coefficient in various conditions of faying surfaces in the following codes: AISC, AIJ and Eurocode 3. However, the Korean Building Code still regulates the unique slip coefficient, 0.45, regardless of the diverse faying conditions. In this study, the slip resistance test, including five kinds of surface treatments were conducted to obtain the proper slip coefficients available to steel plate KS SM490A. The faying surfaces were comprised of a clean mill, rust, red lead paint, zinc primer, and shot blast treatment. The candidates for high strength bolts were torque-shear bolts, torque-shear bolts with zinc coating, and ASTM A490 bolts. Based on the test results, the specimens with a shot blasted surface and rusted surface exhibited $k_s$, 0.61, and 0.5, respectively. It is recommended that the specimens with zinc primer exhibit $k_s{\geq}0.40$. The clean mill treated surface had prominently lower values, 0.27. For red lead painted treatment, the thickness of the coating affects the determinant of slip coefficient, so it is necessary to establish a minimum $k_s$ of 0.2, with a coating thickness of 65 ${\mu}m$. During 1,000 hours of relaxation, the uncoated surfaces exhibited the loss of clamping force behind 3%, while the coated surfaces within a certain limited thickness exhibited the loss of clamping within a range of 4.71% and 8.37%.

Electrical Properties of the Amorphous BaTi4O9 Thin Films for Metal-Insulator-Metal Capacitors (Metal-Insulator-Metal 캐패시터의 응용을 위한 비정질 BaTi4O9 박막의 전기적 특성)

  • Hong, Kyoung-Pyo;Jeong, Young-Hun;Nahm, Sahn;Lee, Hwack-Joo
    • Korean Journal of Materials Research
    • /
    • v.17 no.11
    • /
    • pp.574-579
    • /
    • 2007
  • Amorphous $BaTi_4O_9$ ($BT_4$) film was deposited on Pt/Si substrate by RF magnetron sputter and their dielectric properties and electrical properties are investigated. A cross sectional SEM image and AFM image of the surface of the amorphous $BT_4$ film deposited at room temperature showed the film was grown well on the substrate. The amorphous $BT_4$ film had a large dielectric constant of 32, which is similar to that of the crystalline $BT_4$ film. The leakage current density of the $BT_4$ film was low and a Poole-Frenkel emission was suggested as the leakage current mechanism. A positive quadratic voltage coefficient of capacitance (VCC) was obtained for the $BT_4$ film with a thickness of <70 nm and it could be due to the free carrier relaxation. However, a negative quadratic VCC was obtained for the films with a thickness ${\geq}96nm$, possibly due to the dipolar relaxation. The 55 nm-thick $BT_4$ film had a high capacitance density of $5.1fF/{\mu}m^2$ with a low leakage current density of $11.6nA/cm^2$ at 2 V. Its quadratic and linear VCCs were $244ppm/V^2$ and -52 ppm/V, respectively, with a low temperature coefficient of capacitance of $961ppm/^{\circ}C$ at 100 kHz. These results confirmed the potential suitability of the amorphous $BT_4$ film for use as a high performance metal-insulator-metal (MIM) capacitor.

A Study on the prediction dyspnea-induced attributes of linear regression-based Article

  • Lee, Kwang-Keun;Jeon, Gyu-Hyeon
    • Korean Journal of Artificial Intelligence
    • /
    • v.6 no.2
    • /
    • pp.17-22
    • /
    • 2018
  • According to the World Health Organization, the top 10 causes of death worldwide include heart disease. Heart diseases include coronary disease, which induces acute myocardial infarction. Ticagrelor drugs are being used to treat acute alliances, but it has become difficult to breathe due to the drugs. In a related study, Tobias predicted that uric acid causes acute respiratory distress independently of other factors, including BNP. And in the Ahmad study, serum uric acid numbers were related to the left ventricle depending on the level of uric acid. Experimental data are data used after 155 patients who received coronary intervention took ticagrelor. The research methods were leveraged by gradient decent algorithm and linear regression. In order to avoid overfitting in the experiment, training data and test data were separated into 70 and 30 percent respectively. The experimental results lacked the predictability of other attributes except DT in the correlation coefficient and crystal coefficient. However, all attributes related to dyspnea other than DT are determined to be related to causing relaxation of the heart in the left ventricle. Therefore, the attribute causing dyspnea is determined to be an attribute causing relaxation of the heart of the DT and left ventricle.

Pattern Classification of Four Emotions using EEG (뇌파를 이용한 감정의 패턴 분류 기술)

  • Kim, Dong-Jun;Kim, Young-Soo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.4
    • /
    • pp.23-27
    • /
    • 2010
  • This paper performs emotion classification test to find out the best parameter of electroencyphalogram(EEG) signal. Linear predictor coefficients, band cross-correlation coefficients of fast Fourier transform(FFT) and autoregressive model spectra are used as the parameters of 10-channel EEG signal. A multi-layer neural network is used as the pattern classifier. Four emotions for relaxation, joy, sadness, irritation are induced by four university students of an acting circle. Electrode positions are Fp1, Fp2, F3, F4, T3, T4, P3, P4, O1, O2. As a result, the Linear predictor coefficients showed the best performance.

  • PDF

Stability analysis in BWRs with double subdiffusion effects: Reduced order fractional model (DS-F-ROM)

  • Gilberto Espinosa-Paredes;Ricardo I. Cazares-Ramirez;Vishwesh A. Vyawahare;Erick-G. Espinosa-Martinez
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1296-1309
    • /
    • 2024
  • The aim of this work is to explore the effect of the double subdiffusion on the stability in BWRs. A BWR novel reduced order model with double subdiffusion effects: reduced order fractional model (DS-F-ROM) to describe the neutron and heat transfer processes was proposed for this study. The double subdiffusion was developed with a fractional-order two-equation model, and with different fractional-orders and relaxation times. The stability analysis was carried out using the root-locus method and change from the s to the W domain and were confirmed using the time-domain evolution of neutron flux for a unit step change in reactivity. The results obtained using the reduced fractional-order model are presented for different anomalous diffusion coefficient values. Results are compared with normal diffusion and P1 equations, which are obtained straightforwardly with DS-ROM when relaxation time tends to zero, and when the anomalous diffusion coefficient tends to one, respectively.

Mechanical Behavior of High-tension Bolted Joints with Varying Bolt Size and Plate Thickness (볼트의 크기 및 판두께의 차이에 따른 고장력볼트 이음부의 역학적 거동에 관한 연구)

  • Lee, Seung Yong;Choi, Jun Hyeok;Kim, Sung Hoon;Park, Cheol Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1A
    • /
    • pp.67-74
    • /
    • 2006
  • The use of steel plates has been greatly increased in bridge construction, particularly for long-span bridges. For connections of those steel plates in the field, application of high-tension bold, such as M30, is highly demanded. However, the current steel construction specifications in Korea do not provide information for large-sized bolt connections. In order to evaluate the applicability of the large-sized high-tension bolt, this study experimentally investigates relaxation and slip behavior of M30 bolts with varying bolt size and plate thickness. In addition, internal compressive stress was computed using FEM analysis. The analyzed results were compared with the stress distribution measured from strain gages attached on bolts and bolt holes. From the study presented herein, the M30 high-tension bolts are anticipated to be successfully used with the relaxation less than 10% and the slip coefficient satisfying the specified limit.

Relationship Between Pendulum Test Measurements of Post-Stroke Spasticity (뇌졸중 후 강직 평가를 위한 진자검사 측정값의 상관관계)

  • Kim, Yong-Wook
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.5
    • /
    • pp.325-332
    • /
    • 2010
  • The purpose of this study was to investigate the relationship between three quantitative measures of the pendulum test for spasticity in strokes: The relaxation index, the number of oscillations, and the duration of oscillations. Twenty-six stroke subjects participated in the study. Correlations among these measures of spasticity used Pearson's correlation coefficient. There was a statistically significant positive correlation between the relaxation index and number of oscillations in strokes (r=.881, p<.01). In addition there was significant positive correlation between the relaxation index and duration of oscillations (r=.896, p<.01), and between the number of oscillations and duration of oscillations (r=.938, p<.01). Thus, it is possible to use the number of oscillations and duration of oscillations as quantitative measures of spasticity, rather than the relaxation index, which is more complicated to obtain. According to the result of this study, the use of the simple and objective measurements of the number of oscillations and the duration of oscillations are required clinically in the quantitative measures of spasticity in the future.

A Low-noise Double Relaxation Oscillation SQUID Magnetometer for Measuring Magnetoencephalogram

  • 강찬석;이용호;권혁찬;김진목;윤병운
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.151-158
    • /
    • 2002
  • We developed a useful SQUID magnetometer for biomagnetic applications, magnetoencepha-logram(MEG) and magnetocardiogram(MCG), etc. The SQUIDs are based on Double Relaxation Oscillation SQUID(DROS). DROS consists of two SQUIDs(signal SQUID and reference SQUID) in series, and a relaxation circuit of an inductor and a resistor. Specially we used single reference junction instead of the reference SQUID. The SQUIDs are based on hysteretic $Nb/AlO_{x}$Nb junctions, fabricated by using a simple four level process. Because DROS magnetometer has large flux-to-voltage transfer coefficient, we can use simple flux-locked loop electronics fur SQUID operation. When the DROS magnetometer was operated inside a magnetically shielded room, its average magnetic field noise was about 3 (equation omitted) at 100 Hz. This noise level is low enough to measure biomagnetic fields. In this paper, we describe noise characteristics of DROS magnetometer, depending on the operation condition . .

  • PDF

Experiments on Slip Coefficients of High-Strength Bolt Connection with Weathering Steel (I) (내후성강재 고장력볼트 이음부 미끄럼계수 평가 실험 (I))

  • Park, Yong Myung;Seong, Taek Ryong
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.2 s.45
    • /
    • pp.167-175
    • /
    • 2000
  • An experimental research to evaluate the slip coefficient of high-strength slip-critical-type bolt connection of weathering steel plate has been performed in this paper. Experiments were performed with several surface conditions such as clean mill scale with hand or power brush cleaning, shot blast cleaned, inorganic zinc primer coated, and weather coated surfaces. Also, the relaxation of bolt clamping force was estimated during 500 hours. It was ascertained from the experiments that slip coefficients are greater than 0.40 in all faying surface conditions except mill scale surface with power brushing. The quantify of relaxation depended on the surface conditions and was $3{\sim}8%$, i.e., less than 10%.

  • PDF

Load Relaxation and Creep Transition Behavior of a Spray Casted Hypereutectic Al-Si Alloy (분무 주조 과공정 Al-Si 계 합금의 응력이완 및 Creep 천이 거동)

  • Kim M. S.;Bang W.;Park W. J.;Chang Y. W.
    • Transactions of Materials Processing
    • /
    • v.14 no.6 s.78
    • /
    • pp.502-508
    • /
    • 2005
  • Hypereutectic Al-Si alloys have been regarded attractive for automotive and aerospace application, due to high specific strength, good wear resistance, high thermal stability, low thermal expansion coefficient and good creep resistance. Spray casting of hypereutectic Al-Si alloy has been reported to provide distinct advantages over ingot metallurgy (IM) or rapid solidification/powder metallurgy (RS/PM) process in terms of microstructure refinement. In this study, hypereutectic Al-25Si-2.0Cu-1.0Mg alloy was prepared by OSPREY spray casting process. The change of strain rate sensitivity and Creep transition were analyzed by using the load relaxation test and constant creep test. High temperature deformation behavior of the hypereutectic Al-Si alloy has been investigated by applying the internal variable theory proposed by Chang et al. Especially, the creep resistance of spray casted hypereutectic Al-Si alloy can be enhanced considerably by the accumulation of prestrain.