• Title/Summary/Keyword: Relative performance evaluation

Search Result 510, Processing Time 0.023 seconds

A Study of the Integrated Seakeeping Performance Index in Seaways (선박의 항해중 종합내항성능지표에 관한 연구)

  • 김순갑;공길영
    • Journal of the Korean Institute of Navigation
    • /
    • v.21 no.2
    • /
    • pp.1-9
    • /
    • 1997
  • This paper presented a method of evaluating navigational safety of a ship by means fo the integrted seakeeping performance index(ISPI). The ISPI is defined by measuring only any one factor through the medium of relative dangerousness of the other factors for evaluating seakeeping performance. This evaluation method can be applied to the ships for any types and loading conditions. In devloping the practical evaluation system of navigational safety, it is expected to be useful to solve the difficulties in measuring factors by sensors. The results are also useful for devloping the optimum type of ship by applying at the initial design phase.

  • PDF

A Study of the Integrated Seakeeping Performance Index in Seaways (선박의 항해중 종합내항성능지표에 관한 연구)

  • 김순갑;공길영
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1997.04a
    • /
    • pp.5-16
    • /
    • 1997
  • This paper presented a method of evaluting navigational safety of a ship by means of the integrated seakeeping performance index(ISPI). The ISPI is defined by measuring only any one factor through the medium of relative dangerousness of the other factors for evaluating seakeeping performance. This evaluation method can be applied to the ships for any types and loading conditions. In developing the practical evaluation system of navigational safety. it is expected to be useful for developing the optimum type of ship by applying at the initial design phase.

  • PDF

The Development of Performance Evaluation Measures for Logistics Information Systems on the Basis of BSC (균형성과표(BSC)를 이용한 물류정보시스템 성과평가지표 개발)

  • Kang, Hee-Suk;Kim, Sang-Hoon
    • Journal of Information Technology Services
    • /
    • v.12 no.3
    • /
    • pp.273-287
    • /
    • 2013
  • The objective of this study is to empirically develop performance evaluation measures for LIS (logistics information systems) based upon BSC (balanced scorecard) model and determine the relative importance among four perspectives of BSC using AHP (analytic hierarchy process) methodology. Above all, forty nine probable measures for evaluating LIS performance were identified through reviewing the previous research related with SCM (supply chain management), logistics management, and information systems evaluation. And then, these probable measures were examined by means of coincidence analyses using three mutually exclusive criteria(validity of content, ease of measurement and reliability of measurement). Data for conducting the coincidence analyses were collected from LIS users and LIS development personnel. As the results of the coincidence analyses, it was found that 31 ones among 49 probable performance evaluation measures theoretically derived could be qualified for LIS performance evaluation. And AHP analysis showed that the weight of each perspective was respectively as follows : 46.8% for financial perspective, 31.3% for customer perspective, 14.8% for internal business process perspective, and 7.1% for learning and growth perspective. The academic contribution of this study is that performance evaluation measures for LIS could be systematically and empirically developed on the basis of BSC. Also, the results of this study are expected to be used as a practice guideline of evaluating and improving LIS.

Evaluation of thermal comfort and cooling loads for a multistory building

  • Lykartsis, Athanasios;B-Jahromi, Ali;Mylona, Anastasia
    • Advances in Energy Research
    • /
    • v.5 no.1
    • /
    • pp.65-77
    • /
    • 2017
  • The latest UK Climate Projections (UKCP09) show that mean daily temperatures will increase everywhere in the United Kingdom. This will significantly affect the thermal and energy performance of the current building stock. This study examines an institutional fully glazed building and looks into the changes in the cooling loads and thermal comfort of the occupants during the occupied hours of the non-heating period. Furthermore, it investigates the effect of relative humidity (RH) on thermal comfort. The Design Summer Year (DSY) 2003 for London Heathrow has been used as a baseline for this study and the DSY 2050s High Emissions scenario was used to examine the performance of the building under future weather conditions. Results show a 21% increase of the cooling loads between the two examined scenarios. Thermal comfort appears to be slightly improved during the months of May and September and marginally worsen during the summer months. Results of the simulation show that a relative humidity control at 40% can improve the thermal comfort for 53% of the occupied hours. A comparison of the thermal comfort performance during the hottest week of the year, shows that when the relative humidity control is applied thermal comfort performance of the 2050s is similar or better compared to the thermal comfort performance under the baseline.

A Study on Integrated Quality Evaluation Model of Information System (정보시스템 종합품질평가 모형 연구)

  • Seo, Jang-Hoon;Lee, Gi-Jun;Park, Myeong-Kyu
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.4
    • /
    • pp.151-166
    • /
    • 2006
  • One of The standard issue in riding on the wave of the information system(IS) is records of performance, grow unprecedently fast, and has highly uncertain future. Within the framework of IS Evaluation, The main purpose of this study is to suggest performance quality evaluation system as follows, The Integrated Quality Evaluation Model Design(IQEMD) of Information System helps corporations to improve productivity, customer service and corporate competitive power. To respond flexibly this trend, we have to realize that the information system has to keep the most effective optimal information network at the proper time. The existing evaluation method has been concentrated on the evaluation of a degree of the information system maturity focused on static viewpoints. The evaluation of potential factors to affect the future-oriented performance, that can analyze both unit business being able to apply an information system base was used efficiently well and what performance evaluation item was obtained actually, was insufficient relatively. In this paper, An integrated quality evaluation method will analyze a degree of information system maturity in dynamic evaluation viewpoints rather than in static evaluation viewpoints. finally we estimated the relative degree of importance of each determinant using the AHP methodology The validity of the proposed model was also partially proved using two different methods, holistic and historical approach.

A study on the priorities through weight analysis for each index of performance evaluation of public sewage operation agency (공공하수도 관리대행 성과평가 지표별 가중치분석을 통한 우선순위에 대한 연구)

  • Wi, Mikyung;Park, Chulhwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.6
    • /
    • pp.495-502
    • /
    • 2020
  • The 37 indicators for performance evaluation of public sewage management agencies are divided into four major categories (agency manpower management ability, wastewater treatment plant operation and management, sludge and water reuse, service quality) in the first stage, and the necessity and score acquisition for the detailed indicators by each major category in the second stages. Priority was investigated through the Analytic Hierarchy Process (AHP) analysis technique for ease and relevance of company efforts. Also, based on the results of this analysis, integrated type weighting and relative importance were analyzed. As a result of the analysis, the weight and relative importance of the first stage classification were in the order of wastewater treatment plant operation and maintenance, operation agency manpower management ability, sludge and water reuse, and service quality. As a result of analyzing the weights and priorities of the detailed performance indicators in the second stage, it was found that operator's career years, the percentage of certification holding rate in operators, compliance with the effluent water quality standards, training times for operators, and efforts to manage hazardous chemicals were important. Some of the indicators of operation agency performance evaluation may include indicators in which the performance of the company's efforts is underestimated or overestimated. In order to improve this, it is necessary to give weights in consideration of the necessity of the indicator, the relevance of the company's efforts, and the ease of obtaining scores.

Laboratory/Field evaluation and calibration method of low-cost PM sensor for indoor PM2.5, PM10 measurement (실내 미세먼지 측정을 위한 저가형 PM 센서의 실험실/현장 평가 및 보정 방법)

  • Doheon, Kim;Dongmin, Shin;Jungho, Hwang
    • Particle and aerosol research
    • /
    • v.18 no.4
    • /
    • pp.109-127
    • /
    • 2022
  • Recently, low-cost particulate matter (PM) sensors have been widely used in monitoring mass concentration. Maintaining the accuracy of the sensors is important and requires rigorous performance evaluation and calibration. In this study, two commercial low-cost PM sensors(LCS), Plantower PMS3003 and Plantower PMS7003, were evaluated in the laboratory and field with a reference-grade PM monitor (GRIMM 11-D). Laboratory evaluation was conducted with single/mixed particles of PSL (Poly Styrene Latex) in an acrylic chamber at 20℃ and relative humidity of 20%. Field evaluation was conducted inside a building of Yonsei University (Shinchon) from February 12 to March 31, 2022. In both evaluations, LCS measured values became different from reference measured values when the relative humidity was high or the outdoor air PM10/PM2.5 ratio was high. Based on the field evaluation, the LCS measured values were corrected through four different regression analysis models. As a result, the multivariate polynomial regression analysis model showed highest matching with the reference PM monitor (PM2.5 >0.9, PM10 >0.85). In this model, the PM10/PM2.5 ratio and relative humidity were chosen as independent variables.

Performance Evaluation of Water Vapour Adsorption & Desorption Properties of Low-Priced Generic Ceramic Panel Materials for Humidity Control - Focuses on analyzed measurements of temperature and humidity obtained from the housing units - (저가보급형 습도조절용 세라믹패널의 조습성능 평가 - 리빙랩 온·습도 모니터링 분석을 통한 실측결과를 중심으로 -)

  • Jang, Kun-Young;Ryu, Dong-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.39-40
    • /
    • 2017
  • This study aims to evaluate the humidity control performance of low-priced generic ceramic panels that are used to control humidity. Temperature and humidity are monitored by using 'Living Lab' and the change of indoor relative humidity is measured and analyzed. According to the results of the study, the indoor relative humidity of rooms installed with ceramic panels was found to be low compared to that of living rooms by 2.2%RH (test period) and 3.2%RH (daily). In the case of maximum relative humidity, rooms installed with ceramic panels were found to be low by 6.9%RH. The results are attributable to the humidity absorption of ceramic panels. Accordingly, future ceramic panels need the improvement of performance and an appropriate construction area should be derived depending on indoor space.

  • PDF

A Study on the Development of Navigational Safety Evaluation System in Rough Sea (황천시의 항해안전 평가시스템 개발에 관한 연구)

  • 김순갑;이충로
    • Journal of the Korean Institute of Navigation
    • /
    • v.15 no.1
    • /
    • pp.49-65
    • /
    • 1991
  • It is of great importance for any vessel under way, especially in rough sea, to be maneuvered safely with proper seakeeping performance. In this paper, the author aims to develope a navigational safety evaluation system in rough sea by analyzing ship's with the theory of wave spectrum using random process analysis and the theory of evaluating the seakeeping performance. The scope and the method of this study are as follows ; (1) Modelized typhoon mathematically to represent the sea condition in rough sea. (2) Estimated sea conditions by getting wave spectrum, supposing that the wave by typhoon is fully developed short crest irregular wave. (3) Defined evaluation factor of vessel's seakeeping performance and obtained response amplitude operators thereby. (4) Obtained the response spectrum of factors on seakeeping performance. (5) Defined and obtained evaluation index, dangerousness, relative and maximum dangerousness of factors on seakeeping performance. (6) Analyzed the calculated dangerousness of evaluation index and picked the vertical acceleration out of 7 factors as the presentative factor on seakeeping performance. (7) Carrid out the judgement of danger by obtaining dangerousness value according to steaming hour, course alteration and speed change. By synthesizing the above items, the authors suggests a computer model of navigational safety evaluation system and examined the validity of the model by computer simulation.

  • PDF

A New LMR SG with a Double Tube Bundle Free from SWR

  • Sim Yoon-Sub;Kim Seong-O;Kim Eui Kwang;Hahn Do Hee
    • Nuclear Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.566-580
    • /
    • 2003
  • To resolve the concern of the SWR possibility in LMR and improve the economic feature of LMR, relative performance of various SG designs using a double tube bundle configuration is evaluated and a new SG design concept is proposed. The new steam generator design houses two tube bundles that are functionally different and its tube bundle region is radially divided into two. It prevents the occurrence of sodium water reaction while sodium is still used as the coolant for the primary heat transport system. The feasibility of the SG with a double tube bundle for actual use in an LMR plant is evaluated by setting up the skeleton of the NSSS for various possible configurations of the SG tube bundles. The evaluation revealed the relative advantages and disadvantages of the configurations and the new SG design concept performs good and can be actually used in an LMR plant.