• Title/Summary/Keyword: Relative humidity sensor

Search Result 139, Processing Time 0.026 seconds

Evaluation of pig behavior changes related to temperature, relative humidity, volatile organic compounds, and illuminance

  • Kim, Yong Ju;Song, Min Ho;Lee, Sang In;Lee, Ji Hwan;Oh, Han Jin;An, Jae Woo;Chang, Se Yeon;Go, Young Bin;Park, Beom Jun;Jo, Min Seok;Lee, Chang Gyu;Kim, Hyeun Bum;Cho, Jin Ho
    • Journal of Animal Science and Technology
    • /
    • v.63 no.4
    • /
    • pp.790-798
    • /
    • 2021
  • The objective of this study was evaluation of pig behavior changes related to temperature, relative humidity, volatile organic compounds (VOCs), and illuminance. A total of 24 growing pigs ([Yorkshire × Landrace] × Duroc) were used in the experiment. A sensor was installed at a height of 0.5 m in the center of the pig house. In experiment 1, temperature was changed every four days to 18℃ (T1), 22℃ (T2), 26℃ (T3), and then 30℃ (T4). In experiment 2, relative humidity was adjusted to 45% (low humidity [LH]), 60% (middle humidity [MH]), and then 75% (high humidity [HH]) for four days. In experiment 3, after cleaning the pig house just before experiment, only minimal ventilation was provided. VOCs and pig behaviors were observed for 7 days without cleaning the pig house. In experiment 4, three light bulbs of 40 W (470 lumens / 45 lx; low illuminance [LI]), 75 W (1,055 lumens / 103 lx; middle illuminance [MI]), and 100 W (1,521 lumens / 146 lx; high illuminance [HI]) were used for four days each. Pig behavior analysis was performed for following criteria : Feed intake, Standing, Lying, Sitting, Drink water, Rooting, Posture transition (lying-standing), Posture transition (standing-lying), Wallowing, and Biting. In experiment 1, feed intake time was lower (p < 0.05) for the T3 than other treatment groups. Standing time was highest (p < 0.05) for the T1 and lowest (p < 0.05) for the T3. Lying time was shorter (p < 0.05) in T1 and T2 compared to T3 and T4. Drinking frequency was higher (p < 0.05) for the T4 than other treatment groups. In experiment 2, the frequency of rooting and wallowing increased (p < 0.05) with increasing humidity. LH showed the lowest (p < 0.05) rooting frequency and HH showed the highest (p < 0.05) rooting frequency. In experiment 3, VOCs concentration did not (p > 0.05) change pig behavior. In experiment 4, lying time was the longest (p < 0.05) at LI and shortest (p < 0.05) at HI. Therefore, pig behavior is heavily influenced by the environment, especially temperature and humidity. However, correlation between pig behavior to VOCs and illuminance seems to be needed more research.

Reliability Test of Pd Nanogap-Based Hydrogen Sensors (Pd 나노갭 수소 센서의 신뢰성 연구)

  • Park, Seyoung;Kim, Wonkyung;Lee, Wooyoung
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.399-406
    • /
    • 2020
  • Pd nanogap hydrogen sensors were developed using an elastomeric substrate and operated through an on-off mechanism. A 10 nm thick Pd thin film was formed on a polydimethylsiloxane (PDMS) substrate, and 50% of the physical strain was applied in the longitudinal direction to fabricated uniform nanogaps. The initial concentration of the hydrogen gas for the PDMS/Pd films was controlled, and subsequently, the on-off switching response was measured. We found that the average nanogap was less than 50 nm, and the Pd nanogap hydrogen sensors operated over a wide range of temperatures. In particular, the sensors work properly even at a very low temperature of -40℃ with a fast response time of 2 s. In addition, we have investigated the relative humidity and annealing effects.

FIELD TEST INSTALLATIONS USING N$H_3$SENSOR AND VENTILATION RATE SENSOR FOR CONTINUOUS MEASUREMENT OF TOTAL AMMONIA EMISSION FROM ANIMAL HOUSES

  • Berckmans, D.;Ni, J.Q.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.393-402
    • /
    • 1993
  • Two field test installations are discussed. In the first one a new ammonia sensor and an accurate ventilation rate sensor are combined. They are installed in the exhaust chimney in a ventilated pig house. The relative humidity and the room temperature are measured as well. In the second one, an in situ NH$_3$longrightarrowNO converter with subsequent NOx analyser is also being added for accurate ammonia measurement . In this way , the continuous measurement of the total NH$_3$emission can be obtained , the performance of the NH$_3$ sensor can be evaluated, and the ammonia reduction techniques can be tested. The outputs of measurement are fed into a data acquisition system then to a PC in the laboratory. There has been realised the first test installation with which research on the new ammonia sensor is carried out. The primary research results are presented.

  • PDF

Preparation of New Polyelectrolyte/ Silver Nanocomposites and Their Humidity-Sensitive Properties

  • Park, Min-Su;Lim, Tae-Ho;Jeon, Young-Min;Kim, Jong-Gyu;Gong, Myoung-Seon;Joo, Sang-Woo
    • Macromolecular Research
    • /
    • v.16 no.4
    • /
    • pp.308-313
    • /
    • 2008
  • A simple strategy was developed based on polyelectrolyte/silver nanocomposite to obtain humidity-sensitive membranes. The major component of a humid membrane is the polyTEAMPS/silver nanocomposite obtained by thermal heating the mixture of a polyelectrolyte and silver isopropylcarbamate complex. Humidity sensors prepared from polyTEAMPS/silver (w/w=100/0 and 100/6) nanocomposites had an average impedance of 292, 8.83 and $0.86\;k{\Omega}$, and 5,327, 140 and $0.93\;k{\Omega}$ at 30,60 and 95% relative humidity (RH), respectively. Hysteresis, temperature dependence and response time were also measured. Activation energies and complex impedance spectroscopy of the various components of the polyelectrolyte/silver nanocomposite films were examined for the humidity-sensing membrane.

Humidity Sensitive Properties of Copolymers of Polystyrene Contains Phosphonium Salts (포스포늄 염을 포함한 폴리스티렌 공중합체의 감습 성질)

  • Paek, Jee-Seon;Gong, Myoung-Seon
    • Korean Journal of Materials Research
    • /
    • v.5 no.6
    • /
    • pp.715-722
    • /
    • 1995
  • Vinylbenzyl triphenyl phosphonium chloride (VTPC) was prepared for the humid membrane. The humidity sensitive memo)lane was composed of copolymers, which have differnet content of VTPC and styrene (VTPC : ST=1 : 0.7 : 3, 5 : 5, 3 : 7). The changes in electrical properties of copolymers with relative humidity were measured. It was found that the impedance decreased with an increase of the content of VTPC in the humid membrane, and the Impedance also decreased with an increase of thickness of humid membrane. The copolymer derived from same equip of VTPC and ST showed 12M$\Omega$-100M$\Omega$ at 70%RH-90%RH, which was required for the current humidity sensor operating at high humidity or dew point. The temperature dependence coefficient at a temperature range 15$^{\circ}C$∼35$^{\circ}C$ was found to be -0.5%RH/$^{\circ}C$ and the hysterisis fabled within the range ${\pm}$2%RH. The response time was found to be 40seconds for varing relative humidity from 75% RH to 95%RH and vice versa.

  • PDF

Experimental Investigation on Variation of Internal Relative Humidity and Temperature due to Hydration of Concrete at Early Age (내부 온습도 측정을 통한 초기재령의 콘크리트 내부 습도 및 수화열 변화 특성 분석)

  • Hong, Sung-Ki;Park, Cheol-Woo;Park, Sung-Jae;Kang, Tae-Sung;Kim, Hee-Sung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.741-744
    • /
    • 2008
  • Quality control of early age concrete significantly influences the long term performance. Primary factors for early age concrete quality control should include the relative humidity and temperature variation, and these are more important as structures become massive and huge. Temperature raise due to cement hydration causes stress, which can develop to cracking with internal and/or external restraints. Exposure conditions including ambient temperature, humidity and wind also significantly affect the cracking behavior of early age concrete. Among many of studies on the early age concrete behavior, investigation on the variation of temperature and relative humidity internal of concrete is not common. That is in part because the difficulties in measuring the relative humidity and temperature inside the concrete. This study used a digital sensor with an appropriate logger to measure internal temperature and relative humidity. This direct measuring method is expected to provide more reliable and comprehensive data acquisition on the early age behavior of concrete.

  • PDF

A Study on Metal Oxide based Humidity Sensor with Excellent Humidity Sensing Characteristics (감습특성이 우수한 금속산화물계 습도센서 연구)

  • You, Do-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1982-1988
    • /
    • 2009
  • $TiO_2$ films are fabricated using silk printing method. Heat treatment temperature of films is 600[$^{\circ}C$]. From the analysis of microstructure, grain size of $TiO_2$ films is about $0.2{\sim}0.3[{\mu}m]$. Thickness of films is 30.19[${\mu}m$] and surface uniformity of films is good. From the analysis of crystalline structure, $TiO_2$ films transform anatase phase to rutile phase. Capacitance of films increases according to increase relative humidity and decrease measuring frequency. Hysteresis characteristics of capacitance and impedance are best at 45[%RH] and 75[%RH] respectively. Impedance of films increases according to decrease measuring frequency.

The Interdigitated-Type Capacitive Humidity Sensor Using the Thermoset Polyimide (열경화성 폴리이미드를 이용한 빗살전극형 정전용량형 습도센서)

  • Hong, Soung-Wook;Kim, Young-Min;Yoon, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.604-609
    • /
    • 2019
  • In this study, we fabricated a capacitive humidity sensor with interdigitated (IDT) electrodes using a thermosetting polyimide as a humidifying material. First, the number of electrodes, thickness, and spacing of the polyimide film were optimized, and a mask was designed and fabricated. The sensor was fabricated on a silicon substrate using semiconductor processing equipment. The area of the sensor was $1.56{\times}1.66mm^2$, and the width of the electrode and the gap between the electrodes were each $3{\mu}m$. The number of electrodes was 166, and the length of an electrode was 1.294 mm for the sensitivity of the sensor. The sensor was then packaged on a PCB for measurement. The sensor was inserted into a chamber environment with a temperature of $25^{\circ}C$ and connected to an LCR meter to measure the change in capacitance at relative humidity (RH) of 20% to 90%, 1 V, and 20 kHz. The results showed a sensitivity of 26fF/%RH, linearity of < ${\pm}2%RH$, and hysteresis of < ${\pm}2.5%RH$.

Change in the Concentration of Fine Particles, Temperature, and Relative Humidity as Affected by Different Volume Ratios of Interior Greening in Real Indoor Space (실내녹화 부피비율이 실공간의 미세분진농도, 온도 및 상대습도에 미치는 영향)

  • Ju, Jin-Hee
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.2
    • /
    • pp.1-7
    • /
    • 2010
  • The study objective was to compare the interior greening volume ratios for the change in concentration of fine particle, temperature and relative humidity, and to identify the level of interior landscape volume ratio as a suitable condition to achieve the desired indoor properties. Plants were moved into a room (88m3) randomly. After moving, the volume ratio of the interior greening level was set at 0%, 1%, 2% and 3%. The concentration of fine particles was measured with a mini-volume portable air sampler (Air Metrics, USA). The temperature and relative humidity were recorded with a digital sensor (Kiwi-LTH, USA) during the experiment under different volume ratios with three replications. 1. The results of the change in concentration of the fine particles revealed a trend towards an increased volume ratio of interior greening with decreasing concentration of fine particles, compared to non-plants (0%). The concentration of fine particles at volume ratios of 0%, 1%, 2% and 3% was 55ug/$m^3$, 233ug/$m^3$, 40ug/$m^3$ and 30ug/$m^3$, respectively. 2. The change in temperature, at volume ratios of 0%, 1%, 2% and 3% was $21.2^{\circ}C$, $17.4^{\circ}C$, $16.7^{\circ}C$ and $18.9^{\circ}C$, respectively, in near interior greening, and $22.1^{\circ}C$, $18.7^{\circ}C$, $18.4^{\circ}C$ and $20.5^{\circ}C$ respectively, at a distance of 3m from the interior greening. These study results suggested that temperature was affected by volume ratio and distance from the interior greening. 3. The relative humidity, at volume ratios of 0%, 1%, 2% and 3% was 34.2%, 32.5%, 36.7%, and 46.9%, respectively, in near interior greening, and 31.2%, 26.9%, 31.4% and 38.3%, respectively, at a distance of 3m from the interior greening. With increasing volume ratio of interior landscape, there were positive and significant results between the distance difference and the relative humidity more than temperature.

The WISE Quality Control System for Integrated Meteorological Sensor Data (WISE 복합기상센서 관측 자료 품질관리시스템)

  • Chae, Jung-Hoon;Park, Moon-Soo;Choi, Young-Jean
    • Atmosphere
    • /
    • v.24 no.3
    • /
    • pp.445-456
    • /
    • 2014
  • A real-time quality control system for meteorological data (air temperature, air pressure, relative humidity, wind speed, wind direction, and precipitation) measured by an integrated meteorological sensor has been developed based on comparison of quality control procedures for meteorological data that were developed by the World Meteorological Organization and the Korea Meteorological Administration (KMA), using time series and statistical analysis of a 12-year meteorological data set observed from 2000 to 2011 at the Incheon site in Korea. The quality control system includes missing value, physical limit, step, internal consistency, persistence, and climate range tests. Flags indicating good, doubtful, erroneous, not checked, or missing values were added to the raw data after the quality control procedure. The climate range test was applied to the monthly data for air temperature and pressure, and its threshold values were modified from ${\pm}2{\sigma}$ and ${\pm}3{\sigma}$ to ${\pm}3{\sigma}$ and ${\pm}6{\sigma}$, respectively, in order to consider extreme phenomena such as heat waves and typhoons. In addition, the threshold values of the step test for air temperature, air pressure, relative humidity, and wind speed were modified to $0.7^{\circ}C$, 0.4 hPa, 5.9%, and $4.6m\;s^{-1}$, respectively, through standard deviation analysis of step difference according to their averaging period. The modified quality control system was applied to the meteorological data observed by the Weather Information Service Engine in March 2014 and exhibited improved performance compared to the KMA procedures.