• Title/Summary/Keyword: Relative energy

Search Result 2,022, Processing Time 0.037 seconds

Investigation of the La1-x(Ca or Sr)xCrO3x=0 and 0.25) Interconnect Materials for High Temperature Electrolysis of Steam (고온수증기전기분해용 La1-x(Ca or Sr)xCrO3(x=0 and 0.25) 연결재 재료 연구)

  • Jeong, So-Ra;Kang, Kyoung-Soo;Park, Chu-Sik;Lee, Yong-Taek;Bae, Ki-Kwang;Kim, Chang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.46 no.6
    • /
    • pp.1135-1141
    • /
    • 2008
  • The $La_{1-x}(Ca\;or\;Sr)xCrO_3$(x=0 and 0.25) interconnect materials for high temperature electrolysis of steam were investigated in views of sinterability and electrical conductivity. $LaCrO_3$, $La_{0.75}Ca_{0.25}CrO_3$ (LCC), and $La_{0.75}Sr_{0.25}CrO_3$ (LSC) powders were synthesized by coprecipitation method. Crystal structure was confirmed by X-ray diffraction (XRD). The sintering characteristics were analyzed by relative density and scanning electron microscopy. The electrical conductivity was measured by a DC four probe method. From the analyses of relative densities, it was found that the doped $LaCrO_3$ showed better sinterability than $LaCrO_3$ and the those sinterability increased with decrease of those particle sizes. The XRD results at different sintering temperatures for LCC and LSC revealed that the sinterability is closely related to the second phase transformation, that is, the second phase melting above $1,300^{\circ}C$ for LCC and $1,400^{\circ}C$ for LSC significantly promotes the sinterability. In case of electrical conductivities of LCC and LSC, which had a similar relative density, LCC showed better electrical conductivity than LSC.

Application of analytic hierarchy process technique for selecting a hydrothermal energy site (수열에너지 입지 선정을 위한 계층화분석법의 적용)

  • Joohyun Ahn;Suwan Park;Changhyun Oh
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.38 no.2
    • /
    • pp.69-81
    • /
    • 2024
  • In this study, an evaluation system that can be used to evaluate the feasibility of developing and supplying hydrothermal energy for the operation of large-scale complex facilities was developed. To this end, this study derived factors to be considered when selecting a location for the use of hydrothermal energy using raw water from multi-purpose dams and regional water supply systems through literature survey and expert interviews. The evaluation indicators derived from this study are divided into four sectors: hydrothermal energy utilization factors, location factors, planning factors, and disaster safety factors, and are composed of 10 mid-level indicators and 34 detailed planning indicators. The relative importance of all factors was derived using the Analytic Hierarchy Process (AHP) technique, and the developed evaluation indicators and relative importance were applied to four multi-purpose dam regions in the country. As a result, it was found that in the development and use of hydrothermal energy utilizing regional raw water supply line the urban planning conditions of the supply site can have a greater impact on the location selection results than the hydrothermal energy development itself. Due to the characteristics of the evaluation indicators developed in this study and their nature as comprehensive indicators, it is believed that the results should be applied to determine the overall adequacy of site selection in the early stages of hydrothermal energy development. In the future, it is believed that it will be necessary to analyze the problems in supplying and operating hydrothermal energy using raw water from multi-purpose dams and regional water resources. Based on the analysis the evaluation system developed in this study is expected to be improved and supplemented.

Shaking table test and numerical analysis of nuclear piping under low- and high-frequency earthquake motions

  • Kwag, Shinyoung;Eem, Seunghyun;Kwak, Jinsung;Lee, Hwanho;Oh, Jinho;Koo, Gyeong-Hoi;Chang, Sungjin;Jeon, Bubgyu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3361-3379
    • /
    • 2022
  • A nuclear power plant (NPP) piping is designed against low-frequency earthquakes. However, earthquakes that can occur at NPP sites in the eastern part of the United States, northern Europe, and Korea are high-frequency earthquakes. Therefore, this study conducts bi-directional shaking table tests on actual-scale NPP piping and studies the response characteristics of low- and high-frequency earthquake motions. Such response characteristics are analyzed by comparing several responses that occur in the piping. Also, based on the test results, a piping numerical analysis model is developed and validated. The piping seismic performance under high-frequency earthquakes is derived. Consequently, the high-frequency excitation caused a large amplification in the measured peak acceleration responses compared to the low-frequency excitation. Conversely, concerning relative displacements, strains, and normal stresses, low-frequency excitation responses were larger than high-frequency excitation responses. Main peak relative displacements and peak normal stresses were 60%-69% and 24%-49% smaller in the high-frequency earthquake response than the low-frequency earthquake response. This phenomenon was noticeable when the earthquake motion intensity was large. The piping numerical model simulated the main natural frequencies and relative displacement responses well. Finally, for the stress limit state, the seismic performance for high-frequency earthquakes was about 2.7 times greater than for low-frequency earthquakes.

Spark Plasma Sintering of Stainless Steel Powders Fabricated by High Energy Ball Milling

  • Chang, Si Young;Oh, Sung-Tag;Suk, Myung-Jin;Hong, Chan Seok
    • Journal of Powder Materials
    • /
    • v.21 no.2
    • /
    • pp.97-101
    • /
    • 2014
  • The 304 stainless steel powders were prepared by high energy ball milling and subsequently sintered by spark plasma sintering, and the microstructural characteristics and micro-hardness were investigated. The initial size of the irregular shaped 304 stainless steel powders was approximately 42 ${\mu}m$. After high energy ball milling at 800 rpm for 5h, the powders became spherical with a size of approximately 2 ${\mu}m$, and without formation of reaction compounds. From TEM analysis, it was confirmed that the as-milled powders consisted of the aggregates of the nano-sized particles. As the sintering temperature increased from 1073K to 1573K, the relative density and micro-hardness of sintered sample increased. The sample sintered at 1573K showed the highest relative density of approximately 95% and a micro-hardness of 550 Hv.

Measurement of Energy Dependent Neutron Capture Cross Section of 99Tc

  • Lee, Sam-Yol;Lee, Sang-Bock;Lee, Jun-Haeng;Lee, Jeung-Min;Yoon, Jung-Ran
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2004.11a
    • /
    • pp.495-500
    • /
    • 2004
  • The neutron capture cross section of $^{99}Tc$ has been measured relative to the $^{10}B$(n,g) standard cross section by the neutron time-of-flight(TOF) method in the energy range of 0.007 eV to 47keV using a 46-MeV electron linear accelerator(linac) at the Research Reactor Institute, Kyoto University(KURRI). In order to experimentally prove the result obtained, the supplementary cross section measurement has been made from 0.3 eV to 1 keV using the Kyoto University Lead slowing-down Spectrometer(KULS) coupling to the linac. The relative measurement by the TOF method has been normalized to the reference value(20.01 b) at 0.0253 eV and the KULS measurement to that by the TOF method. The existing experimental data and the evaluated capture cross sections in ENDF/B-VI, JENDL-3.2, and JEF-2.2 have been compared with the current measurements by the linac TOF and the KULS experiments. The energy dependency of the KULS data is close to that of the TOF data which are energy-broadened by the resolution function of the KULS.

  • PDF

Fiber-optic humidity sensor system for the monitoring and detection of coolant leakage in nuclear power plants

  • Kim, Hye Jin;Shin, Hyun Young;Pyeon, Cheol Ho;Kim, Sin;Lee, Bongsoo
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1689-1696
    • /
    • 2020
  • In this study, we developed a fiber-optic humidity sensor (FOHS) system for the monitoring and detection of coolant leakage in nuclear power plants. The FOHS system includes an FOHS, a spectrometer, a halogen white-light source, and a Y-coupler. The FOHS is composed of a humidity-sensing material, a metal tube, a multi-mode plastic optical fiber, and a subminiature version A (SMA) fiber-optic connector. The humidity-sensing material is synthesized from a mixture of polyvinylidene fluoride (PVDF) in dimethyl sulfoxide (DMSO) and hydroxyethyl cellulose (HEC) in distilled water. We measured the optical intensity of the light signals reflected from the FOHS placed inside the humidity chamber with relative humidity (RH) variation from 40 to 95%. We found that the optical intensity of the sensing probe increased linearly with the RH. The reversibility and reproducibility of the FOHS were also evaluated.

A Study on the Eating Behavior, Nutritional Status and Health Condition of Obese Adult Attending a Weight Control Exercise (체중조절 운동을 하고 있는 비만 성인의 식사행동과 영양 섭취 상태 및 건강상태에 관한 연구)

  • 이영순
    • The Korean Journal of Food And Nutrition
    • /
    • v.13 no.2
    • /
    • pp.125-133
    • /
    • 2000
  • The purpose of this study was to investigate eating behavior, nutritional status and health condition of obese adult attending a weight control exercise. The subjects of this study consisted of 81 adult in some areas of Daegu. Their weight, height, triceps, midarm circumference were measured and their dietary intake and eating behavior were obtained by using questionnaires. Anthropometry was conducted to determine obesity. Average age of men and women were 38.1 and 35.2 years old respectively. Their intake of energy and protein were 69.5% and 97.4% of RDA respectively. Energy intake of normal and obese group was 74.4% and 64.9% of RDA respectively. Protein intake of normal and obese group was 99.7% and 95.3% of RDA respectively There was a negative correlation between PIBW and energy intake, PIBW and carbohydrate intake, BMI and energy intake, and BMI and carbohydrate intake. A relative magnitude of factors affecting weight decrease rate was analyzed by Stepwise multiple regression analysis. Overall results about relative influence of independent variables to dependent variable(weight decrease rate) indicated that the BMI(p<0.01) was the most significantly correlated with weight decrease rate in all subjects. The results of this study suggest that the extensive nutrition education in weight control program should be emphasized to prevent obesity early.

  • PDF

Dynamic Design of a Mass-Spring Type Translational Wave Energy Converter (파력발전용 병진 질량-스프링식 파력 변환장치의 동적설계)

  • Choi, Young-Hyu;Lee, Chang-Jo;Hong, Dae-Sun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.1
    • /
    • pp.182-189
    • /
    • 2012
  • This study suggests a dynamic design process for deciding properly design parameters of a mass-spring type Wave Energy Converter (WEC) to achieve sufficient energy conversion from wave to power generator. The WEC mechanism, in this research, consists of a rigid sprung body, a platform, suspension springs and dampers. The rigid sprung body is supported on the platform via springs and dampers and vibrates translationally in the heave direction under wave excitation. At last the resulting heave motion of the sprung body is transmitted to rotating motion of the electric generator by rack and pinion, and transmission gears. For the purpose of vibration analysis, the WEC mechanism has been simply modelled as a mass-spring-damper system under harmonic base excitation. Its maximum displacement transmissibility and steady state response can be determined by using elementary vibration theory if the harmonic ocean wave data were provided. With the vibration analysis results, the suggested dynamic design process of WEC can determine all the design parameters of the WEC mechanism, such as sprung body mass, suspension spring constant, and damping coefficient that can give sufficient relative displacement transmissibility and the associated inertia moment to drive the electric generator and transmission gears.

Determination of Trace Elements in Airborne Particulates by Instrumental Neutron Activation Analysis (중성자 방사화분석법을 이용한 대기분진시료의 정량)

  • Chung, Yong-Sam;Chung, Young-Ju;Jeong, Eui-Sik;Cho, Seung-Yeon
    • Nuclear Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.234-247
    • /
    • 1995
  • Trace elements in airborne particulates were analyzed by instrumental neutron activation analysis (INAA) under the optimum analytical condition. Neutron irradiation for sample was done at the irradiation hole(neutron flux 1$\times$10$^{13}$ n/$\textrm{cm}^2$.s) of TRIGA MARK-III research reactor in the Korea Atomic Energy Research Institute. For the verification of the analytical method, NIST SRM-1648 and NIES CRM No.8 ore chosen and analyzed. The accuracy and precision of the analysis of 40 and 24 trace elements in the samples were compared with the certified and reported values, respectively. The analytical method was found to be reliable enough when the analytical data of NIES sample were compared with those of different counties. In the analytical result of two or both of standard reference materials, relative standard deviation wes within the 15% except a few elements and the relative error was within the 10%. We used this method to analyze 30 trace elements in airborne particulates collected with the high volume air sampler(PM-10) at too different locations and also confirmed the possibility to use this method as a routine monitoring tool to find out environmental pollution sources.

  • PDF

Prediction Correlation of Solar Insolation using Relationships between Meteorological Data and Solar Insolation in 2012 (2012년 기상관측 결과와 한국형 수평면전일사량 예측식(I))

  • Kim, Ha-Yang;Kim, Jeongbae
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.1
    • /
    • pp.1-9
    • /
    • 2016
  • To well design the solar energy system, the correlation to calculate and predict solar irradiation is basically needed. So, this study was performed to reveal the relationships between the solar irradiation and four meteorological observation data(dry-bulb temperature, relative humidity, duration of sunshine, and amount of cloud) that didn't show from previous any other researches. And then, we finally proposed the various order non-linear correlation from the measured solar irradiation and four meteorological measurement data using MINITAB. To show the deviation and accuracy of the solar irradiation between measured and calculated, this study compared for the daily total solar insolation. From those results, the calculation error could well predicted about maximum 97% for the daily total solar insolation. But, the coefficients of the proposed correlations didn't show any relationships. So, needs more studies to make the proper one correlation for the country.