• Title/Summary/Keyword: Relative Operating Characteristic

Search Result 46, Processing Time 0.022 seconds

Fisheye Lens for Image Processing Applications

  • Kweon, Gyeong-Il;Choi, Young-Ho;Laikin, Milton
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.79-87
    • /
    • 2008
  • We have developed a miniature fisheye lens with $190^{\circ}$ field of view operating simultaneously in the visible and the near infrared wavelengths. The modulation transfer function characteristic for the visible wavelength is sufficient for a mega-pixel-grade image sensor. The lens also has a fair resolution in the infrared wavelength region. The calibrated $f-{\theta}$ distortion is less than 5%, and the relative illumination is over 90%. In consequence, a sharp wide-angle image can be obtained which is uniform in brightness over the entire range of field angles. The real image heights for the visible and the near infrared wavelengths have been fitted to polynomial functions of incidence angle with sub-pixel accuracies. Combined with the near equidistance projection scheme of the lens, this lens can be advantageously employed in various image-processing applications requiring a wide-angle lens.

The Characteristic analysis of the IPT system used for PRT(Personal Rapid Transmit) (소형궤도차량 유도전력급전 계통 특성해석)

  • Lee, B.S.;Kim, Do-Won;Han, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.218-220
    • /
    • 2005
  • This paper shows the analysis of the inductive power transfer system in conjunction with series resonant converter operating variable high frequency. Of particular interest is the sensitivity of the complete system to variations in operational frequency and parameters. In inductive power transfer system, electrical power is transferred from a prima교 winding in the form of a coil or track, to one or more isolated pick-up coils that may relative to the primary. The ability to transmit power without contact enables high reliability and easy maintenance that allows inductive power transfer system to be implemented in hostile environments. This technology has found application in many fields such as electric vehicles, PRT(Personal Rapid Transit) etc. The coupling between the primary and secondary is then presented to include the effects of parameter and operational frequency variation.

  • PDF

Characteristic Analysis of Inductive Power Transfer System for PRT (소형궤도 열차용 유도 전력 전송 시스템 특성해석)

  • Min, Byung-Hun;Lee, Byung-Song
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.35-43
    • /
    • 2007
  • In this paper, the inductive power collector using electromagnetic induction for vehicle such as the PRT(Personal Rapid Transit) system is suggested and son ideas for power collector design to improve tile power transfer performance are presented. And also, the analysis of the inductive power transfer system in conjunction with series resonant converter operating variable high frequency is shown. Of particular interest is the sensitivity of the complete system to variations in operational frequency and parameters. In inductive power transfer system electrical power is transferred from a primary winding in the form of a coil or tract to one or more isolated pick-up coils that my relative to the primary. The ability to transmit power without contact enables high reliability and easy maintenance that allows inductive power transfer system to be implemented in hostile environments. This technology has found application in many fields such as electric vehicles, PRT(Personal Rapid Transit) etc. But, low output power is generated due to a loosely coupled characteristic of the large air-gap. Therefore, we will show you various characteristic of inductive power transfer system as double layer construction of secondary winding, which was divided in half to increase both output current and output voltage, a model of power collector and parallel winding structure, a model of concentration/ decentralization winding and the effects of parameter and operational frequency variation.

Development of Work-related Musculoskeletal Disorder Questionnaire Using Receiver Operating Characteristic Analysis (Receiver Operating Characteristic 분석법을 이용한 업무관련성 근골격계질환 설문지 개발)

  • Kwon, Ho-Jang;Ju, Yeong-Su;Cho, Soo-Hun;Kang, Dae-Hee;Sung, Joo-Hon;Choi, Seong-Woo;Choi, Jae-Wook;Kim, Jae-Young;Kim, Don-Gyu;Kim, Jai-Yong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.32 no.3
    • /
    • pp.361-373
    • /
    • 1999
  • Objectives: Receive Operating Characteristic(ROC) curve with the area under the ROC curve(AUC) is one of the most popular indicator to evaluate the criterion validity of the measurement tool. This study was conducted to develop a standardized questionnaire to discriminate workers at high-risk of work-related musculoskeletal disorders using ROC analysis. Methods: The diagnostic results determined by rehabilitation medicine specialists in 370 persons(89 shipyard CAD workers, 113 telephone directory assistant operators, 79 women with occupation, and 89 housewives) were compared with participant's own replies to 'the questionnair on the worker's subjective physical symptoms'(Kwon, 1996). The AUC's from four models with different methods in item selection and weighting were compared with each other. These 4 models were applied to 225 persons, working in an assembly line of motor vehicle, for the purpose of AUC reliability test. Results: In a weighted model with 11 items, the AUC was 0.8155 in the primary study population, and 0.8026 in the secondary study population(p=0.3780). It was superior in the aspects of discriminability, reliability and convenience. A new questionnaire of musculoskeletal disorder could be constructed by this model. Conclusion: A more valid questionnaire with a small number of items and the quantitative weight scores useful for the relative comparisons are the main results of this study. While the absolute reference value applicable to the wide range of populations was not estimated, the basic intent of this study, developing a surveillance fool through quantitative validation of the measures, would serve for the systematic disease prevention activities.

  • PDF

A Study on the Torque Characteristics of Rotary Dampers (로터리 댐퍼의 토오크 특성에 관한 연구)

  • Lee, Choon Tae
    • Journal of Drive and Control
    • /
    • v.16 no.4
    • /
    • pp.87-92
    • /
    • 2019
  • Rotary dampers are damping devices which provide high resistance to shaft rotation. Rotary dampers are being used in various areas to enable the gentle opening and closing of the rotation motion relative to home furniture, industry machinery and automotive parts. Rotary dampers can be installed directly at the rotating point of a various part and can achieve uniform, gentle movement which increases quality and value of products. And generally, the silicone fluid is used as the damping medium because of its stable viscous properties. The movement of these little decelerators can be achieved with a high viscosity of working fluid and throttles installed in the body of the rotary damper. The damping force can be achieved clockwise, anti-clockwise or in both directions according to the structure of the orifices or throttles. In this paper, the torque performances of the rotary damper containing air in the working fluid were studied. For this purpose, the torque characteristic of the rotary damper according to the variation of various operating conditions such as clearance of leakage, dimensions of groove orifice, content ratio of air, etc., were simulated with AMEsim software.

Pedicled Perforator Flaps for Reconstruction of Bilateral Knee Defects: A Case Report

  • Park, Joo Seok;Hong, Joon Pio;Oh, Tae Suk
    • Archives of Reconstructive Microsurgery
    • /
    • v.23 no.2
    • /
    • pp.101-104
    • /
    • 2014
  • Reconstruction of soft tissue defects of the knee has always been a challenging task for plastic surgeons. Various reconstructive choices are available depending on the location, size, and depth of the defect relative to the knee joint. Defects on the knee joint have several characteristic features. The use of a free flap is preferred for reconstructions involving obliteration of large-cavity defects, but recipient pedicle isolation can be difficult because of the extent of the injury zone. Furthermore, the true defect during knee joint flexion is larger than during knee joint extension, and a durable flap is necessary for joint movement. We report for the first time on the use of pedicled perforator flaps for reconstruction of bilateral knee defects in a 76-year-old woman. The operative procedure required skeletonizing the perforators of an antero-lateral thigh flap and antero-medial thigh flap and rotating the flap in the defect. The patient returned to normal daily activity and had a full range of motion two months after the accident. The shorter operating time with decreased donor site morbidity and its durability make this flap a valuable alternative for soft tissue reconstruction of the knee.

Rapid Screening of Phospholipid Biomarker Candidates from Prostate Cancer Urine Samples by Multiple Reaction Monitoring of UPLC-ESI-MS/MS and Statistical Approaches

  • Lim, Sangsoo;Bang, Dae Young;Rha, Koon Ho;Moon, Myeong Hee
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.4
    • /
    • pp.1133-1138
    • /
    • 2014
  • Ultrahigh performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UPLC-ESI- MS/MS) provides a high-speed method to screen a large number of samples for small molecules with specific properties. In this study, UPLC-ESI-MS/MS with multiple reaction monitoring (MRM) was employed to screen urinary phospholipid (PL) content for biomarkers of prostate cancer. From lists of urinary PLs structurally identified using nanoflow LC-ESI-MS/MS, 52 PL species were selected for quantitative analysis in urine samples between 22 cancer-free urologic patients as controls and 45 prostate cancer patients. Statistical treatment of data by receiver operating characteristic (ROC) analysis yielded 14 PL species that differed significantly in relative concentrations (area under curve (AUC) > 0.8) between the two groups. Among PLs present at higher levels in prostate cancer urine, phosphatidylcholines (PCs) and phosphatidylinositols (PIs) constituted the major head group PLs (3 PCs and 7 PIs). For technical reasons, PL species of low abundance may be underrepresented in data from UPLC-ESI-MS/MS performed in MRM mode. However, the proposed method enables the rapid screening of large numbers of plasma or urine samples in the search for biomarkers of human disease.

The Quantitative Evaluation of Aging State of Field Composite Insulators Based on Trap Characteristics and Volume Resistivity-Temperature Characteristics

  • Liang, Ying;Gao, Li-Juan;Dong, Ping-Ping;Gao, Ting
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1355-1362
    • /
    • 2018
  • In order to obtain a better understanding of the ageing process of the field composite insulators, it is necessary to explore a quantitative-valuation method for the aging state evaluation. And the linear relationship between volume resistivity and temperature is proposed. In this paper, the composite insulators with different lengths of operating lives from two manufacturers were tested. The relationship between trap characteristics and volume resistivity-temperature characteristics were analyzed based on Thermal Stimulated Current (TSC), volume resistivity-temperature test, Scanning Electron Microscope (SEM) and Fourier Transform Infrared Spectroscopy (FTIR). Furthermore, the application of trap characteristics in the quantitative evaluation of aging state of composite insulators was discussed. The results showed that there was a general negative correlation between the relative variation ratio of trap charges and the volume resistivity-temperature characteristics. Meanwhile, the physicochemical properties would change with the aging time, which would result in the increasing of electron traps. Combined with the TSC and volume resistivity test results, the trap characteristic thresholds which indicated the serious age of the composite insulators had been proposed.

A Comparative Study of Fuzzy Relationship and ANN for Landslide Susceptibility in Pohang Area (퍼지관계 기법과 인공신경망 기법을 이용한 포항지역의 산사태 취약성 예측 기법 비교 연구)

  • Kim, Jin Yeob;Park, Hyuck Jin
    • Economic and Environmental Geology
    • /
    • v.46 no.4
    • /
    • pp.301-312
    • /
    • 2013
  • Landslides are caused by complex interaction among a large number of interrelated factors such as topography, geology, forest and soils. In this study, a comparative study was carried out using fuzzy relationship method and artificial neural network to evaluate landslide susceptibility. For landslide susceptibility mapping, maps of the landslide occurrence locations, slope angle, aspect, curvature, lithology, soil drainage, soil depth, soil texture, forest type, forest age, forest diameter and forest density were constructed from the spatial data sets. In fuzzy relation analysis, the membership values for each category of thematic layers have been determined using the cosine amplitude method. Then the integration of different thematic layers to produce landslide susceptibility map was performed by Cartesian product operation. In artificial neural network analysis, the relative weight values for causative factors were determined by back propagation algorithm. Landslide susceptibility maps prepared by two approaches were validated by ROC(Receiver Operating Characteristic) curve and AUC(Area Under the Curve). Based on the validation results, both approaches show excellent performance to predict the landslide susceptibility but the performance of the artificial neural network was superior in this study area.

COMPARATIVE STUDY ON THE HORIZOTAL MEASUREMENTS OF SKELETAL CLASS III MALOCCLUSION USING THE ROC ANALYSIS (ROC 분석을 이용한 골격성 III급 부정교합의 수평계측방법간 비교연구)

  • Choi, Hee-Young;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.25 no.2 s.49
    • /
    • pp.153-163
    • /
    • 1995
  • In this study, Receiver Operating Characteristic(ROC) analysis was used to evaluate the ability of cephalometric measurements to identify patients with Class III malocclusions. ROC analysis is the method for determining the validity of a diagnostic measure and for evaluating the relative value of diagnostic tests. The sample consisted of 496 patients with malocclusion. Class III malocclusion is defined as the dental relationship for which The mesiobuccal groove of the lower first molar is deviated mesially from the mesiobuccal cusp of the upper first molar. Of the total sample of 496 patients, 245 had Class III malocclusions. 16 cephalometric measurements were selected, each of which was treated as a diagnostic test. The ROC curves were generated for each cephalometric measurement with intervals of $1.0^{\circ}$ for angular measurements, 1.0mm for linear measurements. The area under the ROC curves was measured for direct comparison among different diagnostic tests. The results were as follows; 1. The 'Wits' appraisal was found to be a better diagnostic criterion for the presence of Class III malocclusion than any other commonly'used cephalometric measurement. 2. AB plane angle, ANB angle, App-Bpp distance, AF-BF distance, APDI, Distance of point A and Pog to N perpendicular, maxillomandibular differential had high diagnostic value. 3. Cephalometric measurements which evaluate the position of the mandible had moderate diagnostic value. 4. Cephalometric measurements related to the maxilla discriminated least between patients with and without Class III malocclusion.

  • PDF