• 제목/요약/키워드: Relative Frequency

검색결과 1,788건 처리시간 0.038초

주파수영역 패널기법을 사용한 유도무기형태 동체에 장착된 엇회전식 프롭팬의 공력해석 (Aerodynamic Analysis of Counter-Rotating Propfans Around a Missile-Like-Body Using a Frequency Domain Panel Method)

  • 조진수
    • 대한기계학회논문집
    • /
    • 제18권6호
    • /
    • pp.1590-1597
    • /
    • 1994
  • The aerodynamic analysis of a $6{\times}6$ counter-rotating propfan around a missile-like-body has been completed analytically using a frequency domain panel method. The present method requires Fourier transformation of flow field around the propfan in computing the velocities normal to the propfan lifting surfaces. The aerodynamic performance curve is determined by angle of attack and nonuniform inflow conditions. The inflow conditions result from the variations of missile flight speed, angle of attack, propfan location relative to control surfaces and control surface deflection angle. The two cases of propfan location relative to control surface, front and behind, are analyzed and the aerodynamic results are presented.

양극산화법으로 제조한 산화 알루미늄 막의 감습특성 연구 (A study on humidity sensing properties of oxide aluminum films by Anodic oxidation)

  • 전범진;전용우;이월인;소대화
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 추계학술대회 논문집
    • /
    • pp.113-117
    • /
    • 1994
  • In this paper, an experiment about humidity sensing properties of oxide aluminum films by Anodic oxidation method was made. The humidity sensing properties of films were investigated in the relative humidity range of 10∼85(%RH) , changing the frequency from 1[kHz] to 100[kHz]. The impedance of humidity sensing films were decreased in accordance with the increase of relative humidity. The decreasing rate of impedance were larger at low measuring frequency. The decreasing difference changes from 17.7M$\Omega$ to 3.68M$\Omega$ at low measuring frequency.

박쥐의 먹이 탐지 전략을 모방한 초음파 센서의 물체 위치 추정 (Ultrasound Echolocation Inspired by a Prey Detection Strategy of Big Brown Bats)

  • 박상욱;김대은
    • 제어로봇시스템학회논문지
    • /
    • 제18권3호
    • /
    • pp.161-167
    • /
    • 2012
  • It is known that big brown bats can distinguish echo of a prey at various angles. In this paper, we suggest a new object localization strategy using ultrasonic echolocation. We calculate the relative energy ratio between a high frequency component of ultrasound signal and a low frequency component of ultrasound signal for a target object. We found the measure depends on bearing angle of the object in space. We also tested energy ratio of echoed FM ultrasound signals depending on frequency, based on cross-correlation. It can determine the relative angular position of objects even though the reflected signals are congested form each object.

A Study on Production of Nitrogen Oxides in Plasma Reactors

  • Lim, Gye-Gyu
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제17권E3호
    • /
    • pp.91-99
    • /
    • 2001
  • Plasma reactor was used to generate a high potential difference between two surfaces of concentric pyrex tubes by electrical current. The annular gap of the reactor was calculated by trial and error from the breakdown voltage equation and set at 0.45 cm. The overall objective of this research was to know the effects of the frequency, humidity, and residence time on the formation of nitrogen oxides in a plasma reactor. The primary voltage varied from 50 to 90 volts and the frequency was varied in increments of 10 Hz from 60 to 650 Hz at the primary voltage of 90. The increase in the secondary voltage was not linear but exponential at high frequencies. At a maximum concentration of about 745 ppm, the frequency and secondary voltage was 600 Hz and 4,200 volts, respectively. All tests for the effects of humidity on NO$_{x}$ production were performed at the optimal setting of 90 colts and 600 Hz frequency. Since the NO$_{x}$ production was not an one dimensional phenomenon, competing reactions were assumed to occur in the discharge chamber. The sharp peak concentration of 1,810 ppm was observed at 38% of relative humidity, The enhanced production was choked off, and the production rate rapidly dropped to 3 ppm at above 40% of relative humidity. It is assumed that the corona attacks the most vulnerable molecules in the reaction chamber before attacking other more lightly bonded molecules, possibly at humidities above 38% and the optimized 90 volt setting. Thus, there was not enough energy left after attacking all water molecules to decompose an appreciable amount of $N_2$. If nitrogen breakdown does not occur, then oxides of nitrogen are not likely to be produced.ced.

  • PDF

고속 광 디스크 드라이브를 위한 디스크의 편심 보상 방법 (A Method for Reducing the Effect of Disk Radial Runout for a High-Speed Optical Disk Drive)

  • 유정래;문정호
    • 제어로봇시스템학회논문지
    • /
    • 제12권2호
    • /
    • pp.101-105
    • /
    • 2006
  • Disk radial runout creates a periodic relative motion between the laser beam spot and tracks formed on an optical disk. While only focus control is activated, the periodic relative motion yields sinusoid-like waves in the tracking error signal, where one cycle of the sinusoid-like waves corresponds to one track. The frequency of the sinusoid-like waves varies depending on the disk rotational speed and the amount of the disk radial runout. If the frequency of the tracking error signal in the off-track state is too high due to large radial runout of the disk, it is not a simple matter to begin track-following control stably. It might take a long time to reach a steady state or tracking control might fail to reach a stable steady state in the worst case. This article proposes a simple method for reducing the relative motion caused by the disk radial runout in the off-track state. The relative motion in the off-track state is effectively reduced by a drive input obtained through measurements of the tracking error signal and simple calculations based on the measurements, which helps reduce the transient response time of the track-following control. The validity of the proposed method is verified through an experiment using an optical disk drive.

PE 계열 절연재 전기적 특성 평가 (Electrical Characteristics Assessment for PE Series Insulations)

  • 정종욱;정진수;한운기
    • 한국전기전자재료학회논문지
    • /
    • 제20권5호
    • /
    • pp.430-435
    • /
    • 2007
  • This paper describes the results of electrical characteristics assessment for organic insulations of polyethylene(PE) series insulations and acrylonitrile butadiene styrene copolymer(ABS). In the experiment, 4 kinds of specimens by composition density were tested in relative permittivity, specific resistance and tracking duration. A WinDETA system and a tracking test set manufactured for this assessment were used to measure the dielectric parameters and tracking duration, respectively. In measuring the tracking duration, the time from testing voltage application to testing circuit breaking due to the tracking current was measured. As a result, dielectric dispersion was observed in measuring the relative permittivity of ABS. It was confirmed that the relative permittivity decreased with the density of the PE series insulations and it depends rather on the temperature than frequency. In most specimens, specific resistance exponentially decreased with frequency and the result for each specimen was almost similar. By the way, in the tracking test, all the PE series insulations showed more excellent performance than ABS and especially in the case of HDPE, its tracking withstand performance was the best.

Immunohistochemical study on the insulin-immunoreactive cells in the developing pancreas of the Korean native goat (Capra hircus)

  • Ku, Sae-kwang;Lee, Hyeung-sik;Lee, Jae-hyun
    • 대한수의학회지
    • /
    • 제39권4호
    • /
    • pp.673-678
    • /
    • 1999
  • The distribution and relative frequency of insulin-immunoreactive cells in the pancreas was studied during developmental stages (fetus, neonate, 1-month-old, 6-month-old and adult) of the Korean native goat by immunohistochemical methods. The different distribution and relative frequency of glucagon-immunoreactive cells in the pancreas of the Korean native goat was observed during development. Insulin-immunoreactive cells were detected in the exocrine and endocrine portions (pancreatic islets) of the all ages, and in the duct of the 6-month-old. The relative frequencies of these cells were increased in the pancreatic islets with ages but decreased in the exocrine portions. Generally, they were distributed in the interacinar spaces or central zone of the pancreatic islets in all ages. However, the distributions and relative frequencies in the pancreatic islets of the neonate Korean native goat were divided into three patterns : 1) located in the inner zone with numerous frequencies, 2) the peripheral zone of the pancreatic islet with moderate frequencies and 3) the peripheral zone of the pancreatic islet with a few frequencies patterns.

  • PDF

우주발사체용 UHF-대역 안테나의 표면결빙에 의한 영향분석 (Effect Analysis of Surface-Icing on the UHF-band Antenna for Space Launch Vehicle)

  • 황수설;오창열;마근수
    • 한국위성정보통신학회논문지
    • /
    • 제9권3호
    • /
    • pp.104-108
    • /
    • 2014
  • 한국형발사체의 표면에 장착되는 UHF-대역 안테나의 표면에 발생하는 결빙을 모델링하고, 이러한 결빙이 안테나의 공진주파수, 반사손실 및 방사패턴 등의 주요 특성에 미치는 영향을 분석하였다. 안테나 표면결빙을 모델링하기 위해 $-180^{\circ}C$의 얼음층에 대한 비유전율을 추출하였고 추출된 비유전율을 이용하여 안테나 표면결빙 모델을 제안하였다. 중심주파수가 UHF-대역인 안테나 표면에 1mm의 결빙이 되었을 경우의 표면결빙 모델을 적용하여 시뮬레이션 한 결과, 표면결빙에 의해 안테나의 공진주파수가 21MHz 하향 되었고, 방사패턴도 전 방향에 대해 전체적으로 10dB 이상의 성능저하가 발생되었다. 따라서 실제 안테나 표면에 결빙이 발생할 경우 안테나 성능에 심각한 영향을 미칠 것으로 판단된다.

Effects of prestressing force on natural frequency of prestressed concrete beams considering self-weight

  • Shin, Soobong;Lee, Hokyoung;Lee, Jong-Han
    • Structural Engineering and Mechanics
    • /
    • 제74권4호
    • /
    • pp.495-502
    • /
    • 2020
  • This study investigated the effects of prestressing force on the natural frequency of concrete beams considering changes in the self-weight of the beam. For this, a finite element formulation was derived to account for the increase in the stiffness of a beam-tendon system due to the axial force and deformation induced by prestressing of the tendon. The developed finite element formulation was validated with the data obtained in laboratory experiments. The experimental natural frequencies of the small prestressed concrete (PSC) beam specimens were consistent with those obtained using the proposed method. The first natural frequency increased almost linearly as the prestressing force increased. The proposed method was then applied to four actual PSC bridges typically employed in the field. Different from the laboratory specimens, the first natural frequencies of the actual PSC bridges barely changed or increased with increasing prestressing force. The results of an analytical parametric study showed that the increase in the natural frequency strongly depended on the magnitude of the prestressing force relative to the total weight of the structure. Thus, the variation in the natural frequencies of the actual PSC bridges with high total weight relative to the prestressing force was negligible due to the application of the prestressing force.

양적 결과지식의 종류가 요추의 고유수용성감각 훈련에 미치는 영향 (The Influence of Different Quantitative Knowledge of Results on Performance Error During Lumbar Proprioceptive Sensation Training)

  • 신원석;최흥식;김택훈;노정석;이진복
    • 한국전문물리치료학회지
    • /
    • 제11권3호
    • /
    • pp.11-18
    • /
    • 2004
  • This study is aimed at investigating the influence of different quantitative knowledge of results on the measurement error during lumbar proprioceptive sensation training. Twenty-eight healthy adult men participated and subjects were randomly assigned into four different feedback groups(100% relative frequency with an angle feedback, 50% relative frequency with an angle feedback, 100% relative frequency with a length feedback, 50% relative frequency with a length feedback). An electrogoniometer was used to determine performance error in an angle, and the Schober test with measurement tape was used to determine performance error in a length. Each subject was asked to maintain an upright position with both eyes closed and both upper limbs stabilized on their pelvis. Lumbar vertebrae flexion was maintained at $30^{\circ}$ for three seconds. Different verbal knowledge of results was provided in four groups. After lumbar flexion was performed, knowledge of results was offered immediately. The resting period between the sessions per block was five seconds. Training consisted of 6 blocks, 10 sessions per one block, with a resting period of one minute. A resting period of five minutes was provided between 3 blocks and 4 blocks. A retention test was performed between 10 minutes and 24 hours later following the training block without providing knowledge of results. To determine the training effects, a two-way analysis of variance and a one-way analysis of variance were used with SPSS Ver. 10.0. A level of significance was set at .05. A significant block effect was shown for the acquisition phase (p<.05), and a significant feedback effect was shown in the immediate retention phase (p>.05). There was a significant feedback effect in the delayed retention phase (p<.05), and a significant block effect in the first acquisition phase and the last retention phase (p<.05). In conclusion, it is determined that a 50% relative frequency with a length feedback is the most efficient feedback among different feedback types.

  • PDF