• 제목/요약/키워드: Reinforcement type

검색결과 886건 처리시간 0.029초

Mechanical behaviors of concrete combined with steel and synthetic macro-fibers

  • Deng, Zongcai;Li, Jianhui
    • Computers and Concrete
    • /
    • 제4권3호
    • /
    • pp.207-220
    • /
    • 2007
  • In this paper, hybrid fibers including high elastic modulus steel fiber and low elastic modulus synthetic macro-fiber (HPP) as two elements were used as reinforcement materials in concrete. The flexural toughness, flexural impact and fracture performance of the composites were investigated systematically. Flexural impact strength was analyzed with statistic analyses method; based on ASTM and JSCE method, an improved flexural toughness evaluating method suitable for concrete with synthetic macro-fiber was proposed herein. The experimental results showed that when the total fiber volume fractions ($V_f^a$) were kept as a constant ($V_f^a=1.5%$), compared with single type of steel or HPP fibers, hybrid fibers can significantly improve the toughness, flexural impact life and fracture properties of concrete. Relative residual strength RSI', impact ductile index ${\lambda}$ and fracture energy $G_F$ of concrete combined with hybrid fibers were respectively 66-80%, 5-12 and 121-137 N/m, which indicated that the synergistic effects (or combined effects) between steel fiber and synthetic macro-fiber were good.

Shear Strength Characteristics of Short-fiber Reinforced Soil for the Application of Retaining Wall Backfill (옹벽 배면토체 적용을 위한 단섬유 보강토의 전단강도 특성)

  • Park, Young-Kon;Cha, Kyung-Seob;Chang, Pyoung-Wuck
    • Proceedings of the KSR Conference
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(II)
    • /
    • pp.73-78
    • /
    • 2003
  • As a fundamental study to develop the retaining wall of new type, short-fibers are mixed with soils and a series of compaction tests and triaxial compression tests for short-fiber reinforced soils are performed. From the results of compaction tests, optimum moisture content is increased and maximum dry unit weight is decreased with fiber mixing ratio. When 60mm fibrillated fiber of 0.2$\%$ mixing ratio is added to SM soil, strength increment of short-fiber reinforced soil is above 1.2 times compared to soil only. Strength increment shows maximum value for composite reinforced soil, namely, soil+short-fiber+planar reinforcement. But in case of mixing with ML soil and short-fiber, the strength of short-fiber reinforced soil is nearly the same as soil only. Internal angle of short-fiber reinforced soil is increased about $2\~3$ degrees and cohesion is also increased above 10kPa compared to soil only. Therefore, it is judged that short-fiber is a good material to strengthen the soil.

  • PDF

Assessment of Geosynthetic Properties of Rubber Reinforced Composites (고무강화 복합재료의 지반용 특성 평가)

  • Jeon, H.Y.
    • Elastomers and Composites
    • /
    • 제34권3호
    • /
    • pp.247-252
    • /
    • 1999
  • Rubber related geosynthetics(GS) as reinforcement and water barrier materials were manufactured by thermal bonding method and examined the their performance for applications to civil and environmental engineering fields. The spunbonded polyester nonwoven, fiber glass mat and fabric type geogrid of a high tenacity polyester filament were used as matrix and polyester film, elastomeric bitumen with SBS polymer and asphalt were used as reinforcements to manufacture the rubber related geosynthetics. A fiber glass mat and geogrid matrix GS showed more excellent mechanical properties and nonwoven and elastomeric bitumen matrix showed the more excellent permittivity. Softening points of rubber and asphalt mixture showed no difference and dimensional stability at high temperature, $120^{\circ}C$, represented no significant shrinkage. Resistance to ultraviolet of rubber related geosynthetics showed no visible alteration.

  • PDF

An Analysis on Nursing Students' Clinical Situation for Development of Oriental Nursing Practice Education (한방간호 실습교육 개발을 위한 간호학생의 임상실습 실태 분석)

  • Yang, Kyung-Hee;Lee, Gyoung-Wan
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • 제15권1호
    • /
    • pp.5-14
    • /
    • 2009
  • Purpose: The purpose of this study was to develop clinical education of Oriental Nursing. Methods: The subjects were one hundred and ninety-three students who have completed clinical practice. The questionnaires were composed of experience type and Oriental Nursing practices(25 items), level of satisfaction(20 items), difficulty level of practices(6 items), and preparation level of practice instructor(5 items). The reliability were Chronbach's $\alpha$=.84, .86, .74, and .93 respectively. Frequencies, percentage, t-test, and Pearson's Correlation was used in data analysis using SPSS PC+ 11.0. Results: Nursing students recognized that they had difficulties caused by a lack of knowledge of Oriental medicine, of learning the uniqueness of the nurse's role and lack of nurse's enthusiasm in teaching students. However, they were confident in preparing acupuncture and implementing Moxibustion, large Moxibustion, Bu-Hang therapy, aroma therapy and on administration of medicines and control of temperature of the medicines, exercise and rehabilitation. Therefore, instructors should train nursing students by developing a unique Oriental Nursing practice and reinforcement of nurses' independent and cooperative roles through the acquisition of Oriental Medical knowledge and terminology. It is necessary that they develop an educational program based on Oriental Nursing practice, perform consistently within the program and train its teaching faculty and instructors.

Technology Risk Management in the Post-catchup Innovation System (탈(脫)추격형 혁신체제에서의 기술 위험 관리)

  • Seong, Ji-Eun;Jung, Byung-Kul
    • Journal of Science and Technology Studies
    • /
    • 제7권1호
    • /
    • pp.33-66
    • /
    • 2007
  • In the post-catchup era, the probability of technology risk are growing according to technology innovation activities with high uncertainty are increasing. Risk acceptance and management are appearing as a more important policy issue. This paper examines the technology risk as a political and social sight and the character of technological risk in the post-catchup era. In the post-catchup, new technology and policy are more undergone trial and err. In particular, we need new approach and policy countermeasures to cope with risky environment and overcome catchup legacy. Accordingly, Korea risk management is needed reshaping of risk management system, increment of risk communication, risk management according to technology type, precautionary approach, bounded trial and err strategy, knowledge accumulation and learning reinforcement.

  • PDF

Estimation of Critical Chloride Threshold Value in Concrete by the Accelerated Corrosion Test

  • Vicho, Victor C.;Bae, Su-Ho;Park, Jae-Im;Lee, Kwang-Myong;Kim, Jee-Sang;Jung, Sang-Hwa
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.201-204
    • /
    • 2006
  • It should be noted that the critical chloride threshold level is not considered to be a unique value for all conditions. This value is dependent on concrete mix proportions, cement type and constituents, presence of admixtures, environmental factors, reinforcement surface conditions, and other factors. In this study, the accelerated corrosion test for reinforcing steel was conducted by electrochemical and cyclic wet and dry seawater method, respectively and during the test, corrosion monitoring by half-cell potential method was carried out to detect the time to initiation of corrosion for individual test specimen. For this purpose, lollypop and right hexahedron test specimens were made for 31%, 42%, and 50% of W/C, respectively, and then the accelerated corrosion test for reinforcing steel was executed. It was observed from the test that the time to initiation of corrosion was found to be different with the water-cement ratio and accelerated corrosion test method, respectively and the critical chloride threshold values were found to range from 0.91 to $1.47kg/m^3$.

  • PDF

The Push-out Resistance Evaluation of Steel Pipe Cap with Perfobond Rib Shear Connector (퍼포본드로 보강된 강관말뚝머리의 압발저항성능 평가)

  • Koo, Hyun-Bon;Kim, Young-Ho;Kang, Jae-Yoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.77-80
    • /
    • 2008
  • The conventional pile cap reinforcement systems regulated in the design specifications have some restrictions in design and construction such as disposition of reinforcing bars, insurance of anchoring length of reinforcements and requirement of shear key. This study suggests a new type of steel pipe pile cap system with perforated rib shear connector as an alternative to the conventional pile cap system for the improvement in structural performance and simplification of construction. And, experimental results of push-out are scribed for the evaluation of structural performance of the new pile cap system and it was compared to the structural behavior of conventional pile cap system.

  • PDF

Anchorage Zone Design of Precast Prestressed Concrete Bridges (프리캐스트 프리스트레스트 콘크리트 교량 구조물의 정착부 설계에 관한 연구)

  • 임동환;오병환;김수석
    • Magazine of the Korea Concrete Institute
    • /
    • 제8권3호
    • /
    • pp.209-218
    • /
    • 1996
  • The purpose of the present study is to explore the effects of local reinforced type and to suggest reliable failure mechanism and the design criteria on the anchorage zones of the precast prestressed concrete bridges. To accomplish these objectives, a comprehensive experimental and analytical study has been conducted. From this study, the cracking and ultimate load capacities for spirally reinforced anchorage zone are found to be larger than those for orthogonal reinforced anchorage zone. This indicate the effectiveness of spiral reinforcement in controlling the cracking. And realistic failure mechanism and design criteria of prestressed anchorage zones based on the present study are suggested.

Sensing and Interfacial Evaluation of Ni Nanowire Strands/Polymer Composites using Electro-micromechanical Technique (Electro-Micromechanical 시험법을 이용한 Ni Nanowire Strands 강화 고분자 복합재료의 Sensing과 계면 물성 평가)

  • Kim, Sung-Ju;Jung, Jin-Gyu;Park, Joung-Man
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 한국복합재료학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.141-144
    • /
    • 2005
  • Sensing and interfacial evaluation of Ni nanowire strands/polymer composites were investigated using Electro-micromechanical technique. Electro-micromechanical techniques can be used as sensing method for micro damage, loading, temperature of interfacial properties. Using Ni nanowire strands/silicone composites with different content, load sensing response of electrical contact resistivity was investigated under tensile and compression condition. The mechanical properties of Ni nanowire strands with different type/epoxy composites were measured using uniformed cyclic loading and tensile test. Ni nanowire strands/epoxy composites showed humidity and temperature sensing within limited ranges, 20 vol% reinforcement. Some new information on temperature and humidity sensing plus loading sensing of Ni nanowire strands/polymer composites could be obtained from the electrical resistance measurement as a new concept of the nondestructive interfacial evaluation.

  • PDF

Structure stability study for existing subway tunnel segment of Seoul-Busan high-speed railroad (Daegu - Busan) construction (경부고속철도(대구-부산) 도심통과 노반신설 공사중 기존 지하철 터널구간의 구조적 안정성 검토)

  • Kong, Byung-Seung;Kim, Min-Ho
    • Proceedings of the KSR Conference
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1752-1759
    • /
    • 2007
  • In the new Seoul-Busan high speed railroad construction specially city center passage roadbed establishment is recommended the staibility for the existing subway tunnel segments of Busan subway line No. 1 and No.2. regarding the appearance condition, a quality condition and the durability of the objective facility site exact inspection, and it evaluates the numerical analysis which uses MIDAS GTS it leads and there is the objective of the place where the stability of the objective facility and this tunnel it investigates. To immediacy of the on-the-spot inspection result whole facility it is a condition where the reinforcement which is simple not to be hindrance is necessary, 2nd Line case it is a condition which transfer is good but the general defect and the damage which occur from the tunnel of NATM type were confirmed part. While roadbed establishment constructing that the continuous maintenance is necessary, it is judged. The result of 1st, 2nd Line maximum sinkage, unequal sinkage and the lining stress of numerical analysis are within permission and the damage degree is appearing with the fact that the degree it will can disregard it is slight. But it enforces necessary Pre-grouting in order to minimize an actual tunnel face conduct and when the tunnel is excavated it is judged with the fact that necessary to minimize the outflow possibility.

  • PDF