• Title/Summary/Keyword: Reinforcement type

Search Result 886, Processing Time 0.03 seconds

Assessment of Long-Term Stability of Geosynthetic Reinforcement Materials by Reduction Factors (감소인자에 의한 토목합성보강재의 장기안정성 평가)

  • Jeon, Han-Yong;Mok, Mun-Sung;Cho, Seong-Ho;Cha, Dong-Hwan;Kim, Seong-Cheol;Ahn, Ju-Hwan
    • Journal of the Korean Geosynthetics Society
    • /
    • v.4 no.3
    • /
    • pp.11-19
    • /
    • 2005
  • Long-term stability of two type geogrids were evaluated. Membrane drawn type geogrid showed the exponential type tensile property and textile type geogrid showed the rapid increase of tensile property closer toward the break point. Short term accelerated creep test was done for textile type geogrid but done for membrane drawn type geogrid at ambient temperature because of its thermal property. Creep strain for membrane drawn type geogrid was larger than the ultimate tensile strain by tensile test. Reduction factor by creep deformation of textile type geogrid was smaller than that of membrane type geogrid. From this result, it was seen that the textile type geogrid is more stable than membrane type geogrid by creep deformation.

  • PDF

Reinforcement of Soft Soil Subgrade for High-Speed Railroad Using Geocell (연약지반상 고속철도 노반 축조시 지오셀 시스템의 효과)

  • 김진만;조삼덕;윤수호;정문경;김영윤
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.11c
    • /
    • pp.129-141
    • /
    • 1999
  • This paper presents the results of plate load test and dynamic load test performed to evaluate the performance of geocell where it is used to reinforce soft subgrade for high-speed railroad. Efficacy of geocell was observed in increase in bearing capacity of subgrade and reduction of thickness of reinforced sub-ballast. Plate load tests were carried out at four different places with varying foundation soil strength as a function of number of geocell layer, type of filler material, thickness of cover soil, and the presence of non-woven geotextile. Dynamic load tests were performed in a laboratory. The test soil chamber consists of, from the bottom, 50 cm thick clayey soil, one layer of geocell filled with crushed stone, 10 cm thick crushed stone cover, reinforced sub-ballast of varying thickness, 35 cm thick ballast. This configuration was determined based on the results of numerical analysis and plate load tests. For each set of the dynamic load tests, loads were applied more than 80,000 times. One layer of geocell underlying a 10 cm thick cover soil led to an increase in bearing capacity three to four times compared to a crushed stone layer of the same thickness substituted for the geocell and cover soil layer. Given the test conditions, the thickness of reinforced sub-ballast can be reduced by approximately 35 cm with the presence of geocell.

  • PDF

Field Performance of Reinforced Earth Wall with Steel Framed-Facing (강재틀 보강토옹벽에 대한 현장 시험시공)

  • Lee, Kwang-Wu;Cho, Sam-Deok;Kim, Ju-Hyong;Seo, Chang-Won
    • Journal of the Korean Geosynthetics Society
    • /
    • v.6 no.4
    • /
    • pp.39-48
    • /
    • 2007
  • This paper introduces a recently developed reinforced earth wall system with steel framed-facing. The new system incorporates a steel-framed facing that might be assembled on-site and steel strip or geogrid type reinforcements for backfill area. In order to enhance scenery view design of the wall construction, dual-structured facing is proposed in which room for planting space locates in the front of facing. A reinforced earth walls using the proposed system was constructed to verify constructability of the proposed system and facing movement and tensile characteristics of reinforcement were measured to understand the mechanical behavior.

  • PDF

Effect of Edge Confinement on Deformation Capacity in the Isolated RC Structural Walls (벽체 단부의 횡보강근 양에 따른 변형능력의 평가)

  • 한상환;오영훈;이리형
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.6
    • /
    • pp.101-112
    • /
    • 1999
  • Structural walls have been mostly used for the design of reinforced concrete buildings in seismic areas because they play a role as an efficient bracing system and offer great potential for lateral load resistance and drift control. The lateral resistance system for the earthquake load should be designed to have enough ductility and stable hysteretic response in the critical regions where plastic deformation occurred beyond yielding. The behavior of the reinforced concrete element to experience large deformation in the critical areas by a major earthquake is affected by the performance of the confined core concrete. Thus, the confinement of concrete by suitable arrangements of transverse reinforcement results in a significant increase in both the strength and ductility of compressed concrete. This paper reports the experimental results of reinforced concrete structural walls for wall-type apartment structure under axial loads and cyclic reversal of lateral loads with different confinement of the boundary elements. The results show that confinement of the boundary element by open 'U'-bar and cross tie is effective. The shear strength capacity is not increased by the confinement but deformation capacity is improve.

Experimental Evaluation of Compressive Characteristics of Cementitious Composites Reinforced by Auxetic Mesh (음의 포아송비 거동 격자체로 보강한 시멘트 복합체의 압축특성 실험평가)

  • Kim, Won-Woo;Lee, Jang-Hwa;Moon, Jae-Heum
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.2
    • /
    • pp.198-203
    • /
    • 2017
  • This study observed the effects of auxetic mesh reinforcement in concrete on the mechanical characteristics under compression. Series of double arrow type 2-D auxetic mesh were manufactured and embedded into concrete specimens. Compression tests were performed and results showed that the application of auxetic mesh as concrete reinforcement can restrain the deformation of concrete resulting in the enhancement of stiffness of composites.

Property Evaluation of Epoxy Resin based Aramid and Carbon Fiber Composite Materials (에폭시 수지 적용 아라미드 및 탄소섬유 복합재료의 물성연구)

  • Seo, Dae-Kyung;Ha, Na Ra;Lee, Jang-Hun;Park, Hyun-Gyu;Bae, Jin-Seok
    • Textile Coloration and Finishing
    • /
    • v.27 no.1
    • /
    • pp.11-17
    • /
    • 2015
  • Recently, super fiber reinforced composite materials are widely used in many industries due to high mechanical properties. In this study, 2 different types of composite materials were manufactured in order to compare their mechanical properties. Carbon and Aramid fibers were used for reinforcement materials and Bisphenol-A type epoxy resin was for matrix. Two kinds of fiber-reinforced materials were manufactured by RIM(Resin Injection Molding) method. Before manufacturing composite materials, the optimal manufacturing and curing process condition were established and the ratio of reinforcement to epoxy resin was discussed. FT-IR analysis was conducted to clarify the structure of epoxy resin. Thermal and mechanical property test were also carried out. The cross-section of composite materials was observed using a scanning electron microscope(SEM).

Application Method for the Structures Under the Full-In Winch on STP Extended Top (STP Extended Top에 설치되는 Pull-In Winch 하부구조 보강방법)

  • Kim, Tae-Wook;Lee, Myeong-Sil;Oh, Tae-Man
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2009.09a
    • /
    • pp.24-34
    • /
    • 2009
  • The latest trend of development for submarine oil field is caused by the drained oil and gas for ground field, and FPSO is a keyword as the development for submarine oil field. FPSO (Floating Production Storage Offloading) is a kind of vessel type have a topside system for production of oil and gas and store them until the oil or gas can be offloaded onto a tanker or transported through a pipeline. Prior to the introduction of reinforcement under the pull-in winch on the STP extended top as the object of this paper, the technical background shall be introduced such as FPSO and the system and main equipments for STP as follows. The original structural concept for reinforcement of pull-in winch on the STP top and extended structure on moonpool was proposed by buyer's engineering team but it was much modified and improved in accordance with builder's fabrication and construction method.

  • PDF

On Propagation of Love waves in dry sandy medium sandwiched between fiber-reinforced layer and prestressed porous half-space

  • Gupta, Shishir;Ahmed, Mostaid
    • Earthquakes and Structures
    • /
    • v.12 no.6
    • /
    • pp.619-628
    • /
    • 2017
  • The intent of this paper is to investigate the propagation of Love waves in a dry sandy medium sandwiched between fiber-reinforced layer and prestressed porous half-space. Separate displacement components have been deduced in order to characterize the dynamics of individual materials. Using suitable boundary conditions, the frequency equation has been derived by means of separation of variables which reveals the significant role of reinforcement parameters, sandiness, thickness of layers, porosity and prestress on the wave propagation. The phase velocity of the Love wave has been discussed in accordance with its typical cases. In both cases when fiber-reinforced and dry sandy media are absent, the derived equation of Love type wave coincides with the classical Love wave equation. Numerical computations have been performed in order to graphically illustrate the dependencies of different parameters on phase velocity of Love waves. It is observed that the phase velocity decreases with the increase of parameters pertaining to reinforcement and prestress. The results have certain potential applications in earthquake seismology and civil engineering.

Seismic Performance of T-Shaped PC Walls with Wet Cast Joint (현장타설 습식접합부가 있는 T형 PC 벽체의 내진성능)

  • Lim, Woo-Young;Hong, Sung-Gul
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.3
    • /
    • pp.255-266
    • /
    • 2014
  • This paper investigates the seismic performance of T-shaped PC walls with a new vertical connections and wet cast joint. The load-displacement relationship, strength, ductility, failure mechanism, and deformation capacity of the T-shaped PC walls subjected to cyclic loading are verified. Test parameter is diagonal reinforcement of both flange and web wall panels to transfer shear strength. The longitudinal reinforcing steel bars placed edges of walls yield first and the ultimate deformation is terminated due to premature failure of connections. And diagonal reinforcements for shear transfer in walls are effective to restrain the wall crack. The strength and displacement obtained by the cross section analysis were very similar to the experimental data.

Shear strengthening of reinforced concrete beams with rectangular web openings by FRP Composites

  • Abdel-Kareem, Ahmed H.
    • Advances in concrete construction
    • /
    • v.2 no.4
    • /
    • pp.281-300
    • /
    • 2014
  • This study presents the experimental results of twenty three reinforced concrete beams with rectangular web openings externally strengthened with Fiber Reinforced Polymers (FRP) composites bonded around openings. All tested beams had the same geometry and reinforcement details. At openings locations, the stirrups intercepted the openings were cut during fabrication of reinforcement cage to simulate the condition of inclusion of an opening in an existing beam. Several design parameters are considered including the opening dimensions and location in the shear zone, the wrapping configurations, and the amount and the type of the FRP composites in the vicinity of the openings. The wrapping configurations of FRP included: sheets, strips, U-shape strips, and U-shape strips with bundles of FRP strands placed at the top and sides of the beam forming a fan under the strips to achieve closed wrapping. The effect of these parameters on the failure modes, the ultimate load, and the beam stiffness were investigated. The shear contribution of FRP on the shear capacity of tested beams with web openings was estimated according to ACI Committee 440-08, Canadian Standards S6-06, and Khalifa et al. model and examined against the test results. A modification factor to account for the dimensions of opening chords was applied to the predicted gain in the shear capacity according to ACI 440-08 and CSA S6-06 for bonded Glass Fiber Reinforced Polymers (GFRP) around openings. The analytical results after incorporating the modification factor into the codes guidelines showed good agreement with the test results.