• Title/Summary/Keyword: Reinforcement Water

Search Result 473, Processing Time 0.025 seconds

Building technical and institutional capacities towards new river maintenance (새로운 하천 유지관리를 위한 기술적·제도적 역량 강화 방안)

  • Lee, Sangeun;Park, Jin-Won;Rhee, Dong Sop;Lee, Du Han;Kim, Dong Hyun;Lee, Seung Oh
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.11
    • /
    • pp.849-862
    • /
    • 2021
  • Laws, administrative rules, and task manuals have been revised to build a modern river maintenance system in Korea for the last decade. And various researches and technology developments have been carried out to resolve related issues. However, the recent enactment of the new Act and the catastrophe of flood damage in 2020 have accelerated more emphasis on the reorganization and reinforcement of the river maintenance system in terms of political and social aspects. In this study, we suggested promising directions for strengthening the technical and institutional competencies of river maintenance with respect to policy, R&D, planning, and technology. The open discussion was held with the participation of industry, academia, research institutes, and government officials, and all participants conducted the related survey to collect their opinions effectively. These results are expected to be used as a reference to secure the justification for integration of government organizations, planning of R&D, the introduction of new river maintenance, and related technology development when reestablishing and reinforcing the river management system in the future.

Usefulness of Dental Hygiene Education Curriculum in the Public Oral Health Service Performance in Korea (한국의 보건소 근무 치과위생사의 공중구강보건사업 수행업무실태와 대학교육간의 연관성)

  • Yoo, Ja-Hea;Cho, Young-Sik;Chung, Won-Gyun;Kwon, Ho-Keun
    • Journal of dental hygiene science
    • /
    • v.5 no.4
    • /
    • pp.165-170
    • /
    • 2005
  • The purpose of this study was to evaluate the usefulness of dental hygiene education curriculum such as oral prophylaxis, preventive dentistry, public oral health, oral health statistics, oral health education in the public oral health service performance. Questionnaire survey was posed to 96 dental hygienists working in health centers and health sub-centers. The relativity among frequency of task, usefulness, importance, and reinforcement of the education curriculum in the health centers, and the effect of current dental hygiene education curriculum on public oral health service were studied. The results were follows; 1. Sealant was performed the most frequently in the health centers and health sub-centers, and it was also the most useful content in the education curriculum. And the tooth brushing method was considered the most important in the curriculum. Therefore, oral health education was considered as factor which required the most reinforcement. However, the issues of school water fluoridation and water fluoridation in the public oral health were barely brought up as a matter of subject. 2. In the relationship between the frequency of task and the usefulness of curriculum, it showed that the more frequency of task was more useful. In the relationship between importance and reinforcements of curriculum, it showed that the more importance of the education curriculum requires more reinforcement. And more frequently performed task should be more strengthened. 3. According to the education course hours, current education curriculum course hours were 532.4 hours, which is 42.9 hours more spent than the original curriculum guideline. Lecture hours were 205.4 hours, which is 50.6 hours less, and the practice hours were 327 hours, which is 93.5 hours more than the original curriculum guideline. 4. Because of the insufficient course hours of curriculum compared to the frequency of the task, the oral health education, oral prophylaxis, and preventive dentistry should be reinforced more than now. But the oral health statistics and public oral health curriculum were not only emphasized, but also any reinforced compared to other tasks.

  • PDF

A Study on the Reinforcement Effect Analysis of Aging Reservoir using Grout Material recycled Power Plant Byproduct (발전부산물을 재활용한 그라우트재의 노후 저수지 보강효과 분석에 관한 연구)

  • Seo, Se-Gwan;An, Jong-Hwan;Cho, Dae-sung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.20 no.2
    • /
    • pp.23-33
    • /
    • 2021
  • In Korea, many reservoirs have been built for the purpose of solving the food shortage problem and supplying agricultural water. However, the current 75.6% of the reservoirs are in serious aged as more than 50 years have passed since the year of construction. In the case of such an aging reservoir, the stability due to scour and erosion inside the reservoir is very reduced, and if concentrated rainfall due to recent abnormal weather occurs, the aging reservoir may collapse, leading to a lot of damage to property and human life. Accordingly, each agency that manages aging reservoirs uses Ordinary Portland Cement (OPC) as an injection material and applies the grouting method. However, in the case of OPC, it may deteriorate over time and water leakage may occur again. And there are environmental problems such as consumption of natural resources and generation of greenhouse gases. So, there is a need to develop new materials and methods that can replace the OPC. In this study, an laboratory test and analysis were performed on the grout material developed to induce a curing reaction similar to that of OPC by recycling power plant byproduct. In addition, test in the field such as electric resistivity survey, Standard Penetration Test (SPT), and field permeability test were performed to analyzed to reinforcement effect and determine the possibility of using instead of OPC. As a results of the test, in the case of recycled power plant byproduct, the compressive strength was 2.9 to 3.2 times and the deformation modulus was 2.3 to 3.3 times higher, indicating that it is excellent in strength and can be used instead of OPC. And it was analyzed that the N value of the reservoir was increased by 1~2, and the coefficient of permeability (k) decreased to the level of 8.9~42.5%. showing sufficient reinforcing effect in terms of order.

Computer based FEM stabilization of oxygen transport model for material and energy simulation in corroding reinforced concrete

  • Hussain, Raja Rizwan
    • Computers and Concrete
    • /
    • v.12 no.5
    • /
    • pp.669-680
    • /
    • 2013
  • This paper unveils a new computer based stabilization methodology for automated modeling analysis and its experimental verification for corrosion in reinforced concrete structures under the effect of varying oxygen concentration. Various corrosion cells with different concrete compositions under four different environmental conditions (air dry, submerged, 95% R.H and alternate wetting-drying) have been investigated under controlled laboratory conditions. The results of these laboratory tests were utilized with an automated computer-aided simulation model. This model based on mass and energy stabilization through the porous media for the corrosion process was coupled with modified stabilization methodology. By this coupling, it was possible to predict, maintain and transfer the influence of oxygen concentration on the corrosion rate of the reinforcement in concrete under various defined conditions satisfactorily. The variation in oxygen concentration available for corrosion reaction has been taken into account simulating the actual field conditions such as by varying concrete cover depth, relative humidity, water-cement ratio etc. The modeling task has been incorporated by the use of a computer based durability model as a finite element computational approach for stabilizing the effect of oxygen on corrosion of reinforced concrete structures.

The influence of EAF dust on resistivity of concrete and corrosion of steel bars embedded in concrete

  • Almutlaq, Fahad M.
    • Advances in concrete construction
    • /
    • v.2 no.3
    • /
    • pp.163-176
    • /
    • 2014
  • Essentially, when electrical current flows easily in concrete that has large pores filled with highly connective pore water, this is an indication of a low resistivity concrete. In concrete, the flow of current between anodic and cathodic sites on a steel reinforcing bar surface is regulated by the concrete electrical resistance. Therefore, deterioration of any existing reinforced concrete structure due to corrosion of reinforcement steel bar is governed, to some extent, by resistivity of concrete. Resistivity of concrete can be improved by using SCMs and thus increases the concrete electrical resistance and the ability of concrete to resist chloride ingress and/or oxygen penetration resulting in prolonging the onset of corrosion. After depassivation it may slow down the corrosion rate of the steel bar. This indicates the need for further study of the effect of electric arc furnace dust (EAFD) addition on the concrete resistivity. In this study, concrete specimens rather than mortars were cast with different additions of EAFD to verify the electrochemical results obtained and to try to understand the role of EAFD addition in influencing the corrosion behaviour of reinforcing steel bar embedded in concrete and its relation to the resistivity of concrete. The results of these investigations indicated that the corrosion resistance of steel bars embedded in concrete containing EAFD was improved, which may link to the high resistivity found in EAFD-concrete. In this paper, potential measurements, corrosion rates, gravimetric corrosion weight results and resistivity measurements will be presented and their relationships will also be discussed in details.

An Analysis on the Failure Mechanism of Slope behind a Plant Complex of Gimhae due to Typhoon Rusa (태풍 루사에 의한 김해 OO단지 사면붕괴 발생원인 분석)

  • Kang, In-Kyu;Ryu, Jeong-Soo;Kim, Hong-Taek;Baek, Seung-Cheol
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.263-266
    • /
    • 2007
  • In this paper, analysis results on the failure of slope behind a Plant Complex of Gimhae due to typhoon Rusa in 2002 are introduced. The left side of the slope was reinforced by soil nails and the right side of the slope was going to construct slope reinforcement works. In the slope failure, the damage area is about $34,000m^2$, the lower width of slope failure is about 230m, the upper width of slope failure is about 50m, and the height of slope failure is about 120m. The elevation of a bedrock in the right side of the slope was lower than the left side of the slope. Due to the depth of weathered soils and weathered rocks in right side of the slope was thick, it will be expected that the effects of pore-water pressure during the rainfalls are large. For the analysis of the failure mechanism, 3-dimensional numerical analysis was carried out by FLAC-3D.

  • PDF

Temperature Crack Control about Sidewall of LNG in Inchon (인천 LNG지하탱크 Sidewall의 온도균열제어)

  • Koo, Bon-Chang;Kim, Dong-Seuk;Ha, Jae-Dam;Kim, Ki-Soo;Choi, Long;Choi, Woong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.329-332
    • /
    • 1999
  • The crack of concrete induced by the heat of hydration is a serious problem, particularly in concrete structures such as underground box structure, mat-slab of nuclear reactor buildings, dams or large footings, foundations of high rise buildings, etc.. As a result of the temperature rise and restriction condition of foundation, the thermal stress which may induce the cracks can occur. Therefore the various techniques of the thermal stress control in massive concrete have been widely used. One of them is prediction of the thermal stress, besides low-heat cement which mitigates the temperature rise, pre-cooling which lowers the initial temperature of fresh concrete with ice flake, pipe cooling which cools the temperature of concrete with flowing water, design change which considers steel bar reinforcement, operation control and so on. The objective of this paper is largely two folded. Firstly we introduce the cracks control technique by employing low-heat cement mix and thermal stress analysis. Secondly it show the application condition of the cracks control technique like sidewall of LNG in Inchonl.

  • PDF

An Experimental Study on the Properties of Ultra Rapid Hardening Mortar Using Magnesia-Phosphate Cement (마그네시아 인산염 시멘트를 사용한 보수용 초속경 모르타르의 특성에 관한 실험적 연구)

  • Ahn, Moo-Young;Jung, Sang-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.4
    • /
    • pp.109-116
    • /
    • 2007
  • Building structures are generally large in size and have a long life, and the construction of such structures requires the investment of a huge amount of money and social infrastructure. Furthermore, building structures are closely related to people's life. Recently, however, the rapid development of society has been worsening air pollution, which is in turn accelerating the degradation of building structures. Thus, the safety of building structure is emerging as a critical issue. To cope with this problem, the government enacted "The Special Act on Safety Control for Infrastructure" but we need engineers' higher concern over the maintenance and reinforcement of existing structures. Recently researches are being made actively on repair mortar using ultra rapid hardening cement for recovering the performance of structures. The present study conducted an experiment on the basic physical properties of ultra rapid hardening mortar for repairing and reinforcing building structures using magnesia cement and mono-ammonium phosphate. In the experiment, we changed the water-cement ratio and carried out replacement at different ratio of MAP/MgO(%). We used retarder to have working life, and made comparative analysis through evaluating working life and fluidity and measuring strength by age.

Fuzzy Inference Based Design for Durability of Reinforced Concrete Structure in Chloride-Induced Corrosion Environment

  • Do Jeong-Yun;Song Hun;Soh Yang-Seob
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.1 s.85
    • /
    • pp.157-166
    • /
    • 2005
  • This article involves architecting prototype-fuzzy expert system for designing the nominal cover thickness by means of fuzzy inference for quantitatively representing the environment affecting factor to reinforced concrete in chloride-induced corrosion environment. In this work, nominal cover thickness to reinforcement in concrete was determined by the sum of minimum cover thickness and tolerance to that defined from skill level, constructability and the significance of member. Several variables defining the quality of concrete and environment affecting factor (EAF) including relative humidity, temperature, cyclic wet and dry, and the distance from coast were treated as fuzzy variables. To qualify EAF the environment conditions of cycle degree of wet-dry, relative humidity, distance from coast and temperature were used as input variables. To determine the nominal cover thickness a qualified EAF, concrete grade, and water-cement ratio were used. The membership functions of each fuzzy variable were generated from the engineering knowledge and intuition based on some references as well as some international codes of practice.

Structural Analysis and Strain Monitoring of the Filament Wound Composite Motor Case used in KSR-III Rocket (KSR-III 삼단 복합재 연소관의 구조 해석 및 변형률 측정)

  • 박재성;김철웅;조인현;오승협;홍창선;김천곤
    • Composites Research
    • /
    • v.14 no.6
    • /
    • pp.24-31
    • /
    • 2001
  • Filament wound structures such as pressure tanks, pipes and motor cases of rockets are widely used in the aerospace application. The determination of a proper winding angle and thickness is very important to decrease manufacturing difficulties and to increase structural efficiency. In this study, possible winding angles considering the slippage between a fiber and a mandrel surface are calculated using the semi-geodesic path equation. In addition, finite element analysis using ABAcUS are performed to predict the behavior of filament wound structures considering continuous change of winding angle along the dome part. The water-pressuring tests of 3rd stage motor case are performed to verify the analysis procedure. The strain gages are attached on the surface in the fiber direction. Progressive failure analysis is performed to predict the burst pressure and the weakest region of the motor case. The effect of reinforcement is also studied to increase its performance.

  • PDF