• Title/Summary/Keyword: Reinforcement Corrosion Monitoring

Search Result 20, Processing Time 0.02 seconds

Resistance to Corrosion of Reinforcement of High Volume Fly Ash Concrete

  • Kwon, S.O.;Bae, S.H.;Lee, H.J.;Lee, K.M.;Jung, S.H.
    • Corrosion Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.209-213
    • /
    • 2014
  • Due to the increasing of interest about the eco-friendly concrete, it is increased to use concretes containing by-products of industry such as fly ash(FA), ground granulated blast furnace slag(GGBFS), silica fume(SF), and etc. Especially, these are well known for improving the resistances to reinforcement corrosion in concrete and decreasing chloride ion penetration. The purpose of this experimental research is to evaluate the resistance against corrosion of reinforcement of high volume fly ash(HVFA) concrete which is replaced with high volume fly ash for cement volume. For this purpose, the concrete test specimens were made for various strength level and replacement ratio of FA, and then the compressive strength and diffusion coefficient for chloride ion of them were measured for 28, 91, and 182 days, respectively. Also, corrosion monitoring by half cell potential method was carried out for the made lollypop concrete test specimens to detect the time of corrosion initiation for reinforcement in concrete. As a result, it was observed from the test results that the compressive strength of HVFA concrete was decreased with increasing replacement ratio of FA but long-term resistances against reinforcement corrosion and chloride ion penetration of that were increased.

The Electrochemical Study of the Concrete Reinforcement Corrosion (콘크리트내부의 철근부식에 관한 전기화학적연구)

  • 강태혁;조원일;신치범;김은겸;주재백;윤경석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.213-217
    • /
    • 1996
  • The electrochemical methods of early detection and analysis of corrosion related deterioration in concrete reinforcement structures are very useful techniques. The generally using procedure for corrosion monitoring of reinforced structures employs a method of half-cell potential measurement. Whilst the technique has provided a useful means of delineating areas of high or low corrosion risk, there are difficulties in its use and interpretation, particularly when assessing corrosion rates of reinforcement. The aim of this study is to describe the AC-impedance method being employed to monitor and assess corrosion rates, to estimate corrosion mechanism of reinfrocement in laboratory conditions. The AC-impedance monitoring technique applies a small amplitude(20mV) AC signal to embedded steel in concrete and reference electrode (Cu/$CuSo_4$). We obtained over a wide frequency range(10MHz~1mHz) to produce a complex plane plot or Nyquist plot.

  • PDF

Role of Sensors in Corrsoin Monitoring in Concrete Structures : the State of the Art (철근 콘크리트 구조물의 부식감시를 위한 센서의 최신기술동향)

  • Ha, Tae-Hyun;Bae, Jeong-Hyo;Ha, Yoon-Cheol;Lee, Hyun-Goo;Park, Kyung-Wha;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.223-226
    • /
    • 2004
  • Many extensive researches in the area of sensor's technology for corrosion monitoring in concrete structures have increasingly been carried out in recent years. This paper gives a brief discussion on the principles and usage of the role of sensors involved in both corrosion initiation and propagation steps of reinforcement corrosion monitoring in concrete structures. Special attention was given to the review of various sensing devices, selection of reliable sensing devices for detecting reinforcement corrosion at the particular environment and at the efficiency of the devices used. Various sensing operations in new and existing concrete structures are also described.

  • PDF

Life cycle reliability analyses of deteriorated RC Bridge under corrosion effects

  • Mehmet Fatih Yilmaz
    • Earthquakes and Structures
    • /
    • v.25 no.1
    • /
    • pp.69-78
    • /
    • 2023
  • Life-cycle performance analysis of a reinforced concrete box section bridge was generated. Moreover, Monte Carlo simulation with important sampling (IS) was used to simulate the bridge material and load uncertainties. The bridge deterioration model was generated with the basic probabilistic principles and updated according to the measurement data. A genetic algorithm (GA) with the response surface model (RSM) was used to determine the deterioration rate. The importance of health monitoring systems to sustain the bridge to give services economically and reliably and the advantages of fiber-optic sensors for SHM applications were discussed in detail. This study showed that the most effective loss of strength in reinforced concrete box section bridges is corrosion of the reinforcements. Due to reinforcement corrosion, the use of the bridge, which was examined, could not meet the desired strength performance in 25 years, and the need for reinforcement. In addition, it has been determined that long-term health monitoring systems are an essential approach for bridges to provide safe and economical service. Moreover the use of fiber optic sensors has many advantages because of the ability of the sensors to be resistant to environmental conditions and to make sensitive measurements.

Risk-based optimum repair planning of corroded reinforced concrete structures

  • Nepal, Jaya;Chen, Hua-Peng
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.2
    • /
    • pp.133-143
    • /
    • 2015
  • Civil engineering infrastructure is aging and requires cost-effective maintenance strategies to enable infrastructure systems operate reliably and sustainably. This paper presents an approach for determining risk-cost balanced repair strategy of corrosion damaged reinforced concrete structures with consideration of uncertainty in structural resistance deterioration. On the basis of analytical models of cover concrete cracking evolution and bond strength degradation due to reinforcement corrosion, the effect of reinforcement corrosion on residual load carrying capacity of corroded reinforced concrete structures is investigated. A stochastic deterioration model based on gamma process is adopted to evaluate the probability of failure of structural bearing capacity over the lifetime. Optimal repair planning and maintenance strategies during the service life are determined by balancing the cost for maintenance and the risk of structural failure. The method proposed in this study is then demonstrated by numerical investigations for a concrete structure subjected to reinforcement corrosion. The obtained results show that the proposed method can provide a risk cost optimised repair schedule during the service life of corroded concrete structures.

Study on The Corrosion Rate Monitoring of Steel in Concrete Using Electric resistance Sensor and Electrochemical Methods. (전기저항형 센서 및 전기화학적 방법을 이용한 철근콘크리트 구조물의 부식속도 측정 방법에 관한 연구)

  • 조용범;김용철;장상엽;고영태
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1185-1192
    • /
    • 2001
  • This paper reviews available techniques for monitoring corrosion of steel in concrete. The need for early detection and diagnosis of corrosion related deterioration in reinforced structures is widely acknowledged. This is particularly important in reinforced concrete structures on account of the economic and social significance of the problem. The current generally used on-site procedure for corrosion monitoring of reinforced structures employs a method of half-cell surface potential measurements. While the technique has provided a useful means of delineating areas of high or low corrosion risk, there are difficulties in its use and interpretation when assessing rates of deterioration. Electrochemical techniques are by far the most suitable for corrosion monitoring purpose and meet most of the requirements. The aim of this paper is to describe the electric resistance sensor(ER sensor) and electrochemical techniques employed to monitor and estimate corrosion rates of reinforcement. Early detection and diagnosis of corrosion hazards allows preventive measures to be taken, hence the typically expensive repair of severely deteriorated structures can be avoided.

  • PDF

Characteristics for Reinforcement Corrosion and Chloride Ion Diffusion of High Volume Fly Ash Concrete (하이볼륨 플라이애시 콘크리트의 철근부식 및 염소이온 확산 특성)

  • Kwon, Soon-Oh;Bae, Su-Ho;Lee, Hyun-Jin;Jung, Sang-Hwa
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.1
    • /
    • pp.34-39
    • /
    • 2014
  • The purpose of this experimental research is to evaluate the resistance of reinforcement corrosion and chloride ion penetration of high volume fly ash (HVFA) concrete. For this purpose, concrete test specimens were made for various strength level and replacement ratio of fly ash, and then compressive strength and diffusion coefficient for chloride ion of them were measured for 28, 91 and 182 days, respectively. Also, corrosion monitoring by half cell potential method was carried out for the made lollypop concrete test specimens to detect the time of corrosion initiation for reinforcement in concrete. As a result, it was observed from the test results that compressive strength of HVFA concrete was decreased with increasing replacement ratio of fly ash but long-term resistance against reinforcement corrosion and chloride ion penetration of that was increased.

The Research on the Ladder System for Corrosion Monitoring (부식 모니터링을 위한 Ladder system에 관한 연구)

  • 송호진;문홍식;이상국;정영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.671-676
    • /
    • 2001
  • Reinforcement corrosion is major problem for those who own and maintain reinforced concrete structures exposed to chlorides. It is well understood that the form of corrosion is more problematic than corrosion found elsewhere, Because concrete has no apparent signs that there is anything amiss until the process of deterioration is relatively far advanced. The objective of this research is to develop the ladder system which monitors the corrosion of reinforcing steels in concrete. This system can be used to assess the corrosion condition and corrosion rate of steel in concrete, which can give timely repair and strengthening of steel in concrete structure.

  • PDF

Development of Corrosion Monitoring Techniques for Reinforcements and Prestressing Tendons (철근 및 PSC 강재 부식감지 기술개발)

  • 윤석구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.1297-1302
    • /
    • 2000
  • A literature review has been carried out to investigate why bridges have collapsed without warning. The reasons behind the collapses have been categorized into short and long term risks. It is thought that permanent monitoring systems which assess structural adequacy are more appropriate to long term risks. From the knowledge of the Korean bridge stock, its current problems and its likely future problems, it was considered that generally the most useful application for a permanent monitoring system is to monitor where chloride-induced corrosion either of the reinforcement or prestressing tendons is possible. A number of permanent monitoring systems currently in use on existing bridges which include some aspect of corrosion detection have been reviewed. The reasons as to why they are being used, what is being measured, what techniques are being used, and if they are deemed successful has been investigated. Based on these findings, and experimental programme has been constructed to investigate the accuracy, reliability and usefulness of various suitable techniques which could be included in a permanent monitoring system.

Estimation of Critical Chloride Threshold Value Using Corrosion Monitoring (부식 모니터링을 이용한 콘크리트 내의 임계 염화물량 평가)

  • Bae Su Ho;Lee Kwang Myong;Chung Young Soo;Kim Jee Sang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.801-804
    • /
    • 2004
  • It should be noted that the critical chloride threshold level is not considered to be a unique value for all conditions. This value is dependent on concrete mixture proportions, cement type and constituents, presence of admixtures, environmental factors, steel reinforcement surface conditions, and other factors. In this study, the accelerated corrosion test for reinforcing steel was conducted by electrochemical and sea water-circulated method, respectively and during the test, corrosion monitoring by half cell potential method was carried out to estimate the critical chloride threshold value when corrosion for reinforcing steel in concrete was perceived. For this purpose, lollypop and beam test specimens were made for $31.4\%,\;41.5\%\;and\;49.7\%$ of w/c. respectively and then the accelerated corrosion test for reinforcing steel was executed. It was observed from the test that the time to initiation of corrosion was found to be different with water-cement ratio and the critical chloride threshold value was found to range from 0.91 to $1.27kg/m^3$.

  • PDF