• Title/Summary/Keyword: Region-Of-Interest

Search Result 1,507, Processing Time 0.328 seconds

Automatic Interpretation of Epileptogenic Zones in F-18-FDG Brain PET using Artificial Neural Network (인공신경회로망을 이용한 F-18-FDG 뇌 PET의 간질원인병소 자동해석)

  • 이재성;김석기;이명철;박광석;이동수
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.455-468
    • /
    • 1998
  • For the objective interpretation of cerebral metabolic patterns in epilepsy patients, we developed computer-aided classifier using artificial neural network. We studied interictal brain FDG PET scans of 257 epilepsy patients who were diagnosed as normal(n=64), L TLE (n=112), or R TLE (n=81) by visual interpretation. Automatically segmented volume of interest (VOI) was used to reliably extract the features representing patterns of cerebral metabolism. All images were spatially normalized to MNI standard PET template and smoothed with 16mm FWHM Gaussian kernel using SPM96. Mean count in cerebral region was normalized. The VOls for 34 cerebral regions were previously defined on the standard template and 17 different counts of mirrored regions to hemispheric midline were extracted from spatially normalized images. A three-layer feed-forward error back-propagation neural network classifier with 7 input nodes and 3 output nodes was used. The network was trained to interpret metabolic patterns and produce identical diagnoses with those of expert viewers. The performance of the neural network was optimized by testing with 5~40 nodes in hidden layer. Randomly selected 40 images from each group were used to train the network and the remainders were used to test the learned network. The optimized neural network gave a maximum agreement rate of 80.3% with expert viewers. It used 20 hidden nodes and was trained for 1508 epochs. Also, neural network gave agreement rates of 75~80% with 10 or 30 nodes in hidden layer. We conclude that artificial neural network performed as well as human experts and could be potentially useful as clinical decision support tool for the localization of epileptogenic zones.

  • PDF

A Study on Middle School Students' Satisfaction and Need for Clothing section of Home Economics in the Textbook (의생활 영역에 대한 중학생의 수업만족도 및 필요도에 관한 연구)

  • Kang Mi-Hyang;Oh Kyung-Wha
    • Journal of Korean Home Economics Education Association
    • /
    • v.18 no.2 s.40
    • /
    • pp.63-77
    • /
    • 2006
  • The Purpose of this study is to provide the basic data for the improvement or the contents or clothing curriculum in the 7th technology home economics of middle school. The standard of satisfaction of students' according to the detail domains and the standard of necessity and practical use and learners' patterns of activity task suggested in textbooks were evaluated. The ninth grade 169 boy students and 336 girl students in the national capital region were participated in this survey. According to the survey results, firstly, a dress domain got the highest relative importance(28.56%) while a clothes material domain took the lowest relative importance(8.07%) among various detail domains. Secondly, the standard of satisfaction according to each detail domain fell below the average. Generally girls' satisfaction for teaching was higher than boys'. Thirdly, a clothes material domain showed the lowest necessity for textbook contents according to detail domain and other domains showed above the average. The necessity for textbook contents appeared high for boy students rather than girl students. In addition, boy and girl students did not have interest in content relevance in textbook. Especially, they could not do well and understand experiments and practices in clothing section. Finally, The degree of utilization of the activity task ill textbooks was very low. Among various activity tasks, the learning by discovering and exploring were more utilized than cooperating learning.

  • PDF

A Study on the Development of Career Education Program for Science Subjects Using Local Resources (지역자원을 활용한 과학교과 연계 진로교육 프로그램 개발 연구)

  • Byoung-Chan Moon
    • Journal of the Korean Society of Earth Science Education
    • /
    • v.16 no.2
    • /
    • pp.210-223
    • /
    • 2023
  • This study developed elementary and middle school career education programs linked to science subjects and local natural resources, and explored learning effects and implications for developing and operating career programs. In order to achieve the research purpose, a 10-hour career education program using local natural and social resources was developed and applied to 25 elementary and middle school students in rural areas. As a result of the study, most of the elementary and middle school students who participated in this study were not well aware of the natural and social resource value of the area where they lived. Therefore, when developing and operating a regional-based career education program for elementary and middle school students in rural areas, it is necessary to operate a separate teaching/learning activity time so that students can fully know the natural and social information and resource values of the region. In addition, in order to enhance students' participation and interest in career education programs, it is necessary to organize the operation of the program in groups, not individuals, and to guide students in detail by dividing the program's performance process into several sub-steps. Finally, the core material of regional-linked career education-related programs focused more on their own content, that is, agricultural products grown by parents, and future job settings were higher in start-ups that directly operate companies such as travel agencies and manufacturing companies. Given the recent emphasis on career education in the curriculum, it is suggested that local students should pay more attention to finding materials with local resource value in the field of geoscience, which is closely related to natural resources, and developing and operating them as career education programs linked to local resources.

Flip Angle of the Optimal T1 Effect Using FLASH Pulse Sequence at 3T Abdominal MRI (FLASH를 이용한 3T 복부검사에 있어서 최적의 T1효과를 위한 적정 Flip Angle)

  • Han, Jae-Bok;Choi, Nam-Gil
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.101-106
    • /
    • 2009
  • Purpose of this study is to compare the signal intensity (SI) and CNR with T1 weighted image using FLASH at 3T abdominal MRI by varying flip angle (FA). Totally 20 patients (male : 12, female : 8, Age : $28{\sim}63$ years with mean : 51) were examined by 3 Tesla MR scanner (Magnetom Tim Trio, SIEMENS, Germany) with 8 channel body array coil between september and October 2008. Imaging parameters were as follows : FLASH sequence, TR : 120 ms, TE : minimum, FOV (field of view) : $360{\times}300\;mm$, Matrix : $256{\times}224$, slice : 6 mm, scan time : 15 sec and Breath-hold technique. Abdominal image, with a 50 ml syringe filled with water placed in the FOV measuring the water signal, were acquired with varying FA through $10^{\circ}$ to $90^{\circ}$ with $10^{\circ}$ interval. SI's were measured three times at liver parenchyme, water, spleen and background and averaged. The CNR's were measured between the ROIs (region of interest). Statistic analysis was performed with ANOVA test using SPSS software (version 17.0). Less than FA $30^{\circ}$, abdominal images were severely inhomogeneity. Especially, T1 effect of water signal was weak. As the flip angle increased, the signal intensity decreased at all the regions. Especially, flip angle of the highest signal intensity was observed with $40^{\circ}$ at the liver parenchyme, $20^{\circ}$ at water, $30^{\circ}$ at the spleen, respectively. The CNR between liver and water was -60.92 at FA $10^{\circ}$ and 15.16 at FA $80^{\circ}$. The CNR between liver and spleen was -3.18 at FA $10^{\circ}$ and 9.65 at $80^{\circ}$. In conclusion, FA $80^{\circ}$ is optimal for T1 weighted effect using FLASH pulse sequence at 3.0 T abdominal MRI.

  • PDF

Research on Traditional Performing Arts Festival - case of Kanto Festival of Akita, Japan- (전통공연예술의 축제화와 연행양상에 대하여 - 일본 아키타 간토마쓰리(竿燈祭)를 중심소재로 삼아)

  • Shin, Keun-Young
    • (The) Research of the performance art and culture
    • /
    • no.39
    • /
    • pp.549-580
    • /
    • 2019
  • There are many festivals in the region that mainly use traditional performing arts. Traditional performing arts has a story that incorporates the history of the area, and it is easy to build a brand that can be distinguished from other areas through traditional performing arts, so it has conditions that are easy to grow in the local festival it can. In this paper, I researched the relationship between the significance and regionality of regional performing arts, referring to the case where traditional performing arts, which is a joint cultural heritage of East Asia, are transmitted as a festival. The performance art with strong locality has grown into a local festival, and the Kanto Festival (竿燈) held in Akita prefecture in northeastern Japan was selected as a representative example of that area. Along with the Aomori Nebuta Festival and the Sendai Tanabata Festival, the Kanto Festival is called the 3 major festivals in the northeastern part of Japan. It was designated as an important intangible folk cultural property in 1980 and became more famous. It visited Seoul several times after the 2005 Japan-Korea Exchange Festival event. It is widely known as a regional festival that represents Japan. The Kanto Festival, which was a participatory event on a village basis, has faced problems such as the migration and aging of young people since the 1970s. In order to solve this, they led the participation of schools, educational institutions, and various groups beyond the village unit and persuaded the participation to the local companies. They have been steadily promoting free lectures on technical skills and school visit events that induce children's interest. As a result, the number of moths mobilized in the current festival has reached 250, and the Kanto tournament also shows great popularity every year.

A Basic Study for the Retrieval of Surface Temperature from Single Channel Middle-infrared Images (단일 밴드 중적외선 영상으로부터 표면온도 추정을 위한 기초연구)

  • Park, Wook;Lee, Yoon-Kyung;Won, Joong-Sun;Lee, Seung-Geun;Kim, Jong-Min
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.2
    • /
    • pp.189-194
    • /
    • 2008
  • Middle-infrared (MIR) spectral region between 3.0 and $5.0\;{\mu}m$ in wavelength is useful for observing high temperature events such as volcanic activities and forest fire. However, atmospheric effects and sun irradiance in day time has not been well studied for this MIR spectral band. The objectives of this basic study is to evaluate atmospheric effects and eventually to estimate surface temperature from a single channel MIR image, although a typical approach utilize split-window method using more than two channels. Several parameters are involved for the correction including various atmospheric data and sun-irradiance at the area of interest. To evaluate the effect of sun irradiance, MODIS MIR images acquired in day and night times were used for comparison. Atmospheric parameters were modeled by MODTRAN, and applied to a radiative transfer model for estimating the sea surface temperature. MODIS Sea Surface Temperature algorithm based upon multi-channel observation was performed in comparison with results from the radiative transfer model from a single channel. Temperature difference of the two methods was $0.89{\pm}0.54^{\circ}C$ and $1.25{\pm}0.41^{\circ}C$ from the day-time and night-time images, respectively. It is also shown that the emissivity effect has by more largely influenced on the estimated temperature than atmospheric effects. Although the test results encourage using a single channel MR observation, it must be noted that the results were obtained from water body not from land surface. Because emissivity greatly varies on land, it is very difficult to retrieval land surface temperature from a single channel MIR data.

A Study on Applied to Optimal Diagnostic Device in Portal Vein Visualization: Focused on MRI and CT (간문맥 묘출을 위한 최적의 영상진단 장치에 관한 연구: MRI, CT 중심으로)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.217-225
    • /
    • 2019
  • The purpose of this study was to quantitate signal to noise ratio and contrast to noise ratio of the portal vein using CT and 3.0T MRI and to investigate the optimal imaging device. Twenty patients who inspective CT and 3.0T MRI between February 2018 and April 2018 were randomly assigned to receive data from the picture archiving communication system. The SNR and CNR values were evaluated by measuring the mean and standard deviation of the region of interest of the four regions of the portal vein (the main portal vein, the right vein, the left vein, and the middle vein). The results showed that SNR was 9.180.72 in the right context, 9.410.84 in the left context, 9.540.59 in the middle context, 9.550.75 in the order context, and 22.292.03 in the right context and 25.893 in the 3.0T MRI. 19, median context: 24.392.87, and order Mac: 26.642.30 (p<0.05). CNR was 3.790.68 in the CT context, 3.740.65 in the left context, 3.710.39 in the middle context, 3.790.68 in the order context, 9.490.65 in the right context, and 11.0001.90 in the 3.0T MRI, Intermediate context: 12.701.75, order Mac: 10.010.98, 3.0T MRI was higher than CT (p<0.05). In conclusion, SNR and CNR values were higher in the 3.0T MRI than CT in the 4 portal regions. Therefore, 3.0T MRI using non-ionizing radiation was the most superior imaging equipment than CT.

Radiation dose Assesment according to the Adaptive Statistical Iterative Reconstruction Technique of Cardiac Computed Tomography(CT) (심장 CT 검사시 ASIR 적용에 따른 선량 평가)

  • Jang, Hyun-Cheol;Kim, Hyun-Ju;Cho, Jae-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.252-259
    • /
    • 2011
  • To identify the effects of the application of the adaptive statistical iterative reconstruction (ASIR) technique in combination with the other two factors of body mass Index (BMI) and tube potential on radiation dose in cardiac CT. The patient receiving operation the cardiac CT examination was divided four groups into according to kVp.[A group(n=20), Non-ASIR, BMI < 25, 100 kVp; B group(n=20), Non-ASIR, BMI > 25, 120 kVp; C group(n=20), 40% ASIR BMI < 25, 100 kVp; D group(n=20), 40% ASIR, BMI > 25, 120 kVp] After setting up the region of interest in the main artery central part and right coronary artery and left anterior descending artery, the CT number was measured and an average and standard deviation were analyzed. There were A group and the difference which the image noise notes statistically between C. And A group was high so that the noise could note than C group (group A, 494 ${\pm}$ 32 HU; group C, 482 ${\pm}$ 48 HU: P<0.05) In addition, there were B group and the difference noted statistically between D. And B group was high so that the noise could note than D group (group B, 510 ${\pm}$ 45 HU; group D, 480 ${\pm}$ 82 HU: P<0.05). In the qualitative analysis of an image, there was no difference (p>0.05) which a group, B group, C group, and D as to average, A group 4.13${\pm}$0.2, B group 4.18${\pm}$0.1, and C group 4.1${\pm}$0.2 and D group note statistically altogether with 4.15${\pm}$0.1 as a result of making the clinical evaluation according to the coronary artery segments. And the inappropriate image was shown to the diagnosis in all groups. As to the radiation dose, a group 8.6${\pm}$0.9 and B group 14.9${\pm}$0.4 and C group 5.8${\pm}$0.5 and D group are 10.1${\pm}$0.6 mSv.

Effect of Human Implantable Medical Devices on Dose and Image Quality during Chest Radiography using Automatic Exposure Control (자동노출제어를 적용한 흉부 방사선 검사 시 인체 이식형 의료기기가 선량과 화질에 미치는 영향)

  • Kang-Min Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.257-265
    • /
    • 2024
  • In this study, we applied AEC(Auto Exposure Control), which is used in many chest examinations, to evaluate whether medical devices inserted into the body affect the dose and image quality of chest images. After attaching three HIMD(Human implantable medical devices) to the ion chamber, the Monte Carlo methodology-based program PCXMC(PC Program for X-ray Monte Carlo) 2.0 was applied to measure the effective dose by inputting the DAP(Dose Ares Product) value derived from the Pacemaker and CRT and Chemoport Additionally, to evaluate image quality, we set three regions of interest and one noise region on the chest and measured SNR and CNR. The final study results showed significant differences in DAP and Effective dose. There was a significant difference between Pacemaker and CRT when AEC was applied and not applied. (p<0.05) When applied, the dose increased by 37% for Pacemaekr and 52% for CRT. Chemoport showed a 10% increase in effective dose depending on whether AEC was applied, but there was no significant difference. (p>0.05) In the image quality evaluation, there was no significant difference in image quality between all HIMD insertions and AEC applied or not. (p>0.05) Therefore, when the HIMD was inserted into the chest during a chest x ray and overlapped with the ion chamber sensor, the effective dose increased, and there was no difference in image quality even at a low dose without AEC. Therefore, when performing a chest X-ray examination of a patient with a HIMD inserted, it is considered that performing the examination without applying AEC is a method that can be considered to reduce the patient's radiation exposure.

Evaluation of Proper Image Acquisition Time by Change of Infusion dose in PET/CT (PET/CT 검사에서 주입선량의 변화에 따른 적정한 영상획득시간의 평가)

  • Kim, Chang Hyeon;Lee, Hyun Kuk;Song, Chi Ok;Lee, Gi Heun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.22-27
    • /
    • 2014
  • Purpose There is the recent PET/CT scan in tendency that use low dose to reduce patient's exposure along with development of equipments. We diminished $^{18}F$-FDG dose of patient to reduce patient's exposure after setting up GE Discovery 690 PET/CT scanner (GE Healthcare, Milwaukee, USA) establishment at this hospital in 2011. Accordingly, We evaluate acquisition time per proper bed by change of infusion dose to maintain quality of image of PET/CT scanner. Materials and Methods We inserted Air, Teflon, hot cylinder in NEMA NU2-1994 phantom and maintained radioactivity concentration based on the ratio 4:1 of hot cylinder and back ground activity and increased hot cylinder's concentration to 3, 4.3, 5.5, 6.7 MBq/kg, after acquisition image as increase acquisition time per bed to 30 seconds, 1 minute, 1 minute 30 seconds, 2 minute, 2 minutes 30 seconds, 3 minutes, 3 minutes 30 seconds, 4 minutes, 4 minutes 30 seconds, 5 minutes, 5 minutes 30 seconds, 10 minutes, 20 minutes, and 30 minutes, ROI was set up on hot cylinder and back radioactivity region. We computated standard deviation of Signal to Noise Ratio (SNR) and BKG (Background), compared with hot cylinder's concentration and change by acquisition time per bed, after measured Standard Uptake Value maximum ($SUV_{max}$). Also, we compared each standard deviation of $SUV_{max}$, SNR, BKG following in change of inspection waiting time (15minutes and 1 hour) by using 4.3 MBq phantom. Results The radioactive concentration per unit mass was increased to 3, 4.3, 5.5, 6.7 MBqs. And when we increased time/bed of each concentration from 1 minute 30 seconds to 30 minutes, we found that the $SUV_{max}$ of hot cylinder acquisition time per bed changed seriously according to each radioactive concentration in up to 18.3 to at least 7.3 from 30 seconds to 2 minutes. On the other side, that displayed changelessly at least 5.6 in up to 8 from 2 minutes 30 seconds to 30 minutes. SNR by radioactive change per unit mass was fixed to up to 0.49 in at least 0.41 in 3 MBqs and accroding as acquisition time per bed increased, rose to up to 0.59, 0.54 in each at least 0.23, 0.39 in 4.3 MBqs and in 5.5 MBqs. It was high to up to 0.59 from 30 seconds in radioactivity concentration 6.7 MBqs, but kept fixed from 0.43 to 0.53. Standard deviation of BKG (Background) was low from 0.38 to 0.06 in 3 MBqs and from 2 minutes 30 seconds after, low from 0.38 to 0 in 4.3 MBqs and 5.5 MBqs from 1 minute 30 seconds after, low from 0.33 to 0.05 in 6.7 MBqs at all section from 30 seconds to 30 minutes. In result that was changed the inspection waiting time to 15 minutes and 1 hour by 4.3 MBq phantoms, $SUV_{max}$ represented each other fixed values from 2 minutes 30 seconds of acquisition time per bed and SNR shown similar values from 1 minute 30 seconds. Conclusion As shown in the above, when we increased radioactive concentration per unit mass by 3, 4.3, 5.5, 6.7 MBqs, the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the same way, in the change of inspection waiting time (15 minutes and 1 hour), we could find that the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the result of this NEMA NU2-1994 phantom experiment, we found that the minimum acquisition time per bed was 2 minutes 30 seconds for evaluating values of fixed $SUV_{max}$ and SNR even in change of inserting radioactive concentration. However, this acquisition time can be different according to features and qualities of equipment.

  • PDF