• Title/Summary/Keyword: Region Separation

Search Result 555, Processing Time 0.028 seconds

Antioxidative Materials in Domestic Meju and Doengjang 3. Separation of Hydrophilic Brown Pigment and Their Antioxidant Activity (재래식 메주 및 된장중의 항산화성 물질에 관한 연구 3. 수용성 갈변물질의 항산화력)

  • 이종호;김미혜;임상선;김성희;김경업
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.23 no.4
    • /
    • pp.604-613
    • /
    • 1994
  • Hydrophilic brown pigments(HBPs) produced during fermentation and aging the domestic Meju and Doenjang were separated by dialysis and chromatography , and their antioxidant activity were measured . The chemical properties of HBP were determined by UV and IR spectrophotometry. HBPs contents were found to be 93.1 mg/g and 183.2mg/g in Meju fermentated for 30 days and 80 days , respectively. The ratio of dialysate to diffusate of the HBPs were appeared to be 70 : 30 and 87 :13 in the Meju fermented for 30 days and 80 days, respectively. and the rtio in the Doenjang aged for 60 days was 91 :9 , indicating that dialysate slowly days, respectively, and the ratio in the Doenjang aged for 60 days was 91 : 9, incidatin that dialysate slowly increased by the fermentation . Both portion exhibited strong antioxidant activity, but more stronger antioxidant activity was found in the dialysate. DEAE-celluose column chromatography showed that dialysate contained more materials eluted by 0.01-0.03M HCI solution than 0.01M acetate buffer, but diffusate showed opposite results. The degree of browning reaction and antioxdiant activity found in the fraction eluted by HCI solution was stronger than that of the fraction eluted by acetate buffer. The fraction eluted from DEAE-cellulose column chormatogrphy was further fractionaged by TLC and found that strong antioxidant activity was present in the fractions which did not possess fluorescenece and showed a negative ninhydrin reaction. TLC fractions of HCI eluant in Meju exhibited a strong absorbance at 260-280nm, but most of other fractions did not show any absorbance at UV region. TLC fractions from dialysate and diffusate showed fairly identical IR spectrum with absorbance at 3400cm-1, 2800cm-3000cm -1, 1600cm, -1 1400cm-1 and 1100 cm-1 , however, in addition to these absorbances, the spectrum from HCI eluant of Meju exhibited a strong absorbance at 1750cm , indicating the carbonic acid or carbonate ester.

  • PDF

A STUDY ON THE IMPROVEMENT OF κ-εTURBULENCE MODEL FOR PREDICTION OF THE RECIRCULATION FLOW (재순환유동 예측을 위한 κ-ε 난류모델 개선에 대한 연구)

  • Lee, Y.M.;Kim, C.W.
    • Journal of computational fluids engineering
    • /
    • v.21 no.2
    • /
    • pp.12-24
    • /
    • 2016
  • The standard ${\kappa}-{\varepsilon}$ and realizable ${\kappa}-{\varepsilon}$ models are adopted to improve the prediction performance on the recirculating flow. In this paper, the backward facing step flows are used to assess the prediction performance of the recirculation zone. The model constants of turbulence model are obtained by the experimental results and they have a different value according to the flow. In the case of an isotropic flow situation, decaying of turbulent kinetic energy should follow a power law behavior. In accordance with the power law, the coefficients for the dissipation rate of turbulent kinetic energy are not universal. Also, the other coefficients as well as the dissipation coefficient are not constant. As a result, a suitable coefficients can be varied according to each of the flow. The changes of flow over the backward facing step in accordance with model constants of the ${\kappa}-{\varepsilon}$ models show that the reattachment length is dependent on the growth rate(${\lambda}$) and the ${\kappa}-{\varepsilon}$ models can be improved the prediction performance by changing the model constants about the recirculating flow. In addition, it was investigated for the curvature correction effect of the ${\kappa}-{\varepsilon}$ models in the recirculating flow. Overall, the curvature corrected ${\kappa}-{\varepsilon}$ models showed an excellent prediction performance.

A Study on Analysis Spatial Structure of Industry by Using the Freight O/D - Focused on Daegu Metropolitan City (화물 O/D를 이용한 대도시권 산업공간구조 분석에 관한 연구)

  • Kim, Keunuk;Hwang, Junghoon;Kim, Kapsoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6D
    • /
    • pp.557-563
    • /
    • 2012
  • The purpose of this study is to analyze the spatial structure of Mega-Economic Region particularly in Daegu using Freight Origin-Destination (O/D) Data which comes from KTDB. To diagnose the appropriate separation of Regions, the mean of three standardized indices was calculated. The indicates measured are Freight Occupancy Ratio (FOR), Freight Dependancy Ratio (FDR), Scale Parameter (SP), respectively. The result of analysis showed that FOR FDR SP indicators gave effective explanation about characteristic of Regions depending on Freight moving patterns. Especially, Gyeongsan and Gumi had high correlation Regions with FOR FDR indicator. Also, the major industries of Daegu Metropolitan based on the SP indicator are Chemical and Metal machinery industry.

Numerical Study of the Rib Arrangements for Enhancing Heat Transfer in a Two-pass Channel of Large Aspect Ratio (종횡비가 큰 이차유로에서 냉각성능 향상을 위한 요철배열 연구)

  • Han, Sol;Choi, Seok Min;Sohn, Ho-Seong;Cho, Hyung Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.3
    • /
    • pp.161-169
    • /
    • 2017
  • The present study investigated the effect of the rib arrangement and a guide vane for enhancing internal cooling of the blade. Two types of rib arrangements were used in the first and second passage in parallel. Aspect ratio of the channel was 5 and a fixed Reynolds number based on hydraulic diameter was 10,000. The attack angle of rib was $60^{\circ}$, rib pitch-to-height ratio (p/e) was 10, and the rib height-to-hydraulic-diameter ratio ($e/D_h$) was 0.075. The effect of an interaction between Dean vortices and the secondary vortices from the first passage was observed. Overall, the attack angle of rib in the first passage was dominant factor to heat transfer and flow patterns in turning region. Also, the channel with a guide vane showed enhanced heat transfer at the tip surface with reducing flow separation and recirculation.

Structural Aspects of the Reduced Free-floating Hydrophyte, Spirodela polyrhiza (부유부엽성 개구리밥 식물체의 구조분화 연구)

  • Kim, Kyoung-Ae;Kim, In-Sun
    • Applied Microscopy
    • /
    • v.30 no.2
    • /
    • pp.233-240
    • /
    • 2000
  • Aspects of structural differentiation of the free -floating hydrophyte, Spirodela polyrhira, has been investigated. The hydrophyte exhibited highly reduced structures having only fronds, connective stalks, and roots as a mature plant. The fronds were major photosynthetic and vegetatively reproducing organ during the growth. Daughter fronds which developed early in the mother frond were also chlorenchymatous, but they remained within foliage sheaths of the mother frond before separation from connecting stalks. Although the stalks and roots originated from the same meristematic region of the frond, they exhibited the distinct polarity showing former lateral growth and latter axial growth. Air chambers were formed only in the fronds and roots. Cellular components were scattered throughout the diffuse cytoplasm in most of the actively growing stalk cells. Root cells protected by the root cap demonstrated relatively complex organization, showing dense cytoplasm with Golgi, rER, mitochondria, and chloroplasts in the cortical cells. Cells in the root cap were highly vacuolated within the peripheral cytoplasm. Such reduction and differentiation of the plant body in Spirodela polyrhiza most effectively contributes to the better adaptation of smaller plants to superficial aquatic environments, while also enabling the rapid growth.

  • PDF

Study on Plastics Detection Technique using Terra/ASTER Data

  • Syoji, Mizuhiko;Ohkawa, Kazumichi
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1460-1463
    • /
    • 2003
  • In this study, plastic detection technique was developed, applying remote sensing technology as a method to extract plastic wastes, which is one of the big causes of concern contributing to environmental destruction. It is possible to extract areas where plastic (including polypropylene and polyethylene) wastes are prominent, using ASTER data by taking advantage of its absorptive characteristics of ASTER/SWIR bands. The algorithm is applicable to define large industrial wastes disposal sites and areas where plastic greenhouses are concentrated. However, the detection technique with ASTER/SWIR data has some research tasks to be tackled, which includes a partial secretion of reference spectral, depending on some conditions of plastic wastes and a detection error in a region mixed with vegetations and waters. Following results were obtained after making comparisons between several detection methods and plastic wastes in different conditions; (a)'spectral extraction method' was suitable for areas where plastic wastes exist separated from other objects, such as coastal areas where plastic wastes drifted ashore. (single plastic spectral was used as a reference for the 'spectral extraction method') (b)On the other hand, the 'spectral extraction method' was not suitable for sites where plastic wastes are mixed with vegetation and soil. After making comparison of the processing results of a mixed area, it was found that applying both 'separation method' using un-mixing and ‘spectral extraction method’ with NDVI masked is the most appropriate method to extract plastic wastes. Also, we have investigated the possibility of reducing the influence of vegetation and water, using ASTER/TIR, and successfully extracted some places with plastics. As a conclusion, we have summarized the relationship between detection techniques and conditions of plastic wastes and propose the practical application of remote sensing technology to the extraction of plastic wastes.

  • PDF

Thermal Elasto-Plastic Deformation Analysis of Metal Matrix Composites Considering Residual Stress and Interface Bonding Strength (잔류응력과 계면접합강도를 고려한 금속복합재료의 열탄소성 변형 해석)

  • Kang, Chung-Gil;Seo, Young-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.1 s.94
    • /
    • pp.227-237
    • /
    • 1999
  • As the interface bonding phenomenon between the matrix and the reinforcements has a large effect on the mechanical properties of MMCs, a sugestion of the strength analysis technique considering the residual stress and the interface bonding phenomenon is very important for the design of pans and the estimation of fatigue behavior. In this paper the three dimensional finite element anaysis is performed during the elasto-plastic deformation of the particulate reinforced metal matrix composites. It was analyzed with the volume fractions in view of microscale. Bonding strength. interface separation and matrix void growth between the matrix and the reinforcements will be predicted on deformation under tensile loading. An interface seperation is estimated by the fracture criterion which is a critical value of generalized plastic work per unit volume. The shape of the reinforcement is assumed to be a perfect sphere. And the type of the reinforcement distribution is assumed as FCC array. The thermal residual stress in MMCs is induced by the heat treatment. It is included at the simulation as an initial residual stress. The element birth and death method of the ANSYS program is used for the estimation of the interface bonding strength, void generation and propagation. It is assumed that the fracture in the matrix region begin to occur under the external loading when the plastic work per unit volume is equal to the critical value. The fracture strain will be defined. The experimental data of the extruded $SiC_p$>/606l Al composites are compared with the theoretical results.

  • PDF

A Study on the Architectural Planning Characteristics of Medical Buildings - Focused on Cheong-ju Area (메디컬빌딩의 건축계획특성 연구 - 청주지역을 중심으로)

  • Baek, Sang Yeol;Kim, Gi Soo
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.21 no.3
    • /
    • pp.69-77
    • /
    • 2015
  • Purpose: Under a trend of hospitals that repeated expansion in line with fast increasing factors of medical demands in the past, medical buildings where clinic businesses have regularly gathered in one building have exponentially increased since separation of prescribing and dispensing in 2000. Thus, this study aims at analyzing characteristics of architectural plan of the current medical buildings, identifying strengths and weaknesses through Post Occupancy Evaluation and suggesting an architectural planning method of medical buildings to be planned in the future. Methods: Scope of study has been limited to 23 medical buildings that are registered in the building register as medical buildings out of the Class 1 neighborhood facilities build as 5 floors or more in Cheongju region since 2000 and being actually used for the usage. Study method is to define concepts of the medical buildings through literature review and advanced researches, analyze characteristics of architectural plan through drawing analysis and site survey. Results: General characteristics of architectural plans for the medical buildings in Cheongju have been analyzed. There are the most frequencies in general commercial area and semi-residential area, most of them are reinforced concrete structure and the Class 1 neighborhood facilities. Average land area is $482.68m^2$, gross floor area $3720.8m^2$, the number of underground floors level 1.16, the number of floors level 7.76, total number of floors 8.92, the building-to-land ratio 67.28%, floor area ratio 452.6%, height 31.44m, and the number of parked vehicles 24.16. Implications: This research will contribute to the establishment of the planning methods which increase the quality of Medical Buildings in Cheongju.

Flow Field in Volute for Various Operating Conditions of Centrifugal Compressor (원심압축기의 운전점에 따른 벌류트 내부 유동장)

  • Kang, Kyung Jun;Shin, You Hwan;Kim, Kwang Ho;Lee, Yoon Pyo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.531-538
    • /
    • 2013
  • The primary function of centrifugal compressor volute is to flow from the impeller and diffuser to the pipe system. The strength of the scroll vortex and flow pattern in the volute vary with the operating point. This is largely caused by the interaction between the impeller and the volute flow fields. The recirculation flow around the tongue and the scroll vortex can be used to understand the characteristics of the volute flow at off-design points. The present study aims to find the characteristics of a flow pattern in the diffuser and volute of a centrifugal compressor from the rectangular cross section of the volute. Measurements are carried out using PIV. The results obtained in this study show that the separation region around the tongue is reduced and that the recirculation flow increases as the flow coefficient decreases.

Unsupervised Classification of Forest Vegetation in the Mt. Wolak Experimental Forest Using Landsat Thematic Mapper Data (Landsat Thematic Mapper 화상자료를 이용한 월악산 지역 산림식생의 무감독분류)

  • Lee, Sang Hee;Park, Jae Hyeon;Lee, Joon Woo;Kim, Je Su
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.4 no.2
    • /
    • pp.36-44
    • /
    • 2001
  • The main purpose of this study was to classify forest vegetation effectively using Landsat Thematic Mapper data(June, 1994) in mountainous region. The research area was the Mt. Wolak Experimental Forest of Chungbuk National University, near Chungju and Jecheon city, Chungcheongbuk-do. To classify forest vegetation effectively, Normalized Difference Vegetation Index(NDVI) was used to reduce topographic effects. This NDVI was modified and transformed to the value of 0 to 255, and then the modified values were combined with other Landsat Thematic Mapper bands. To classify forest and land cover types, unsupervised classification method was used. The results of this study are summarized as follows. 1. Combinations of band "3, 5, NDVI" in Landsat Thematic Mapper data showed a good separation with high accuracy. The expected classification accuracy was 95.1% in Landsat Thematic Mapper data. 2. The Land Cover types were classified into six groups : coniferous forest, deciduous forest, mixed forest, paddy and grass, non-forest, and other undetectable areas. As these classified results were compared with the reconnaissance survey and aerial black and white infrared photographs, the overall classification accuracy was 76.5% in Landsat Thematic Mapper data. 3. The portion of non-forest in Mt. Wolak area was 1.9%. The percentages of coniferous, deciduous and mixed forests were 30.9%, 35.7% and 26.4%, respectively. 4. As these classified results were compared with other reference data, the percentages of coniferous, deciduous and mixed forests increased, but the portion of non-forest was exceedingly diminished. These differences are thought to be from the different research method and the different season of received Landsat Thematic Mapper data.

  • PDF