• Title/Summary/Keyword: Refrigerator Noise

Search Result 98, Processing Time 0.021 seconds

Reduction of Refrigerant-induced Noise of the Refrigerator by Modification of the Evaporator Inlet Pipe (증발기 입구 배관의 구조 개선을 통한 냉장고 냉매 소음 저감)

  • Kim, Min-Seong;Han, Hyung-Suk;Kim, Tae-Hun;Jeong, Wei-Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.10
    • /
    • pp.1012-1020
    • /
    • 2009
  • This research is focused on the experimental study of the noise induced by two-phase refrigerant flow in the evaporator. The two-phase flow in the evaporator has various flow patterns. The effects of two-phase flow pattern's characteristics on the noise of the evaporator are investigated experimentally. The experimental data shows that the generated noise is mainly related to the layout of the pipe and the certain two-phase flow patterns such as the churn and slug flow. Based on these results, we removed the unnecessary vertical pipe and changed the pipe diameter of the evaporator - inlet into small one in order to avoid the intermittent flow condition. The noise level of newly-designed inlet-pipe of the evaporator was measured experimentally by refrigerant-supplying equipment and compared with that of conventional one.

Electromagnetic Noise Reduction of Reciprocating Compressor using Random PWM (랜덤 PWM을 이용한 왕복동식 압축기의 전자기소음 저감)

  • 조관열;양순배;김학원
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.200-207
    • /
    • 2000
  • Recently, it is increased to apply the inverter system to household electrical appliances, especially in the air c conditioners, refrigerators and washing machines, to reduce the power consumption and the acoustic noise by t the low speed operation, and to make their functions more comfortable for human beings. For the inverter s systems, however, it is highly required to reduce the undesirable electromagnetic noise and psychoacoustic n noise generated by PWM for variable speed operation. In this paper, the electromagnetic noise for the d detenninistic PWM and random PWM for the reciprocating compressors driven by the brusWess dc motor was a analyzed. It was also verified through the experiment that the elt'Ct$\tau$omagnetic noise was reduced and the s sound quality was improved by applying the random PWM.

  • PDF

Improvement in flow and noise performance of backward centrifugal fan by redesigning airfoil geometry (익형 형상 재설계를 통한 후향익 원심팬의 유동 및 소음성능 개선)

  • Jung, Minseung;Choi, Jinho;Ryu, Seo-Yoon;Cheong, Cheolung;Kim, Tae-hoon;Koo, Junhyo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.6
    • /
    • pp.555-565
    • /
    • 2021
  • The goal of this study is to improve flow and noise performances of existing backward-curved blade centrifugal fan system used for circulating cold air in a refrigerator freezer by optimally designing airfoil shape. The unique characteristics of the system is to drive cold airflow with two volute tongues in combination with duct system in a back side of a refrigerator without scroll housing generally used in a typical centrifugal fan system. First, flow and noise performances of existing fan system were evaluated experimentally. A P-Q curve was obtained using a fan performance tester in the flow experiment, and noise spectrum was measured in an anechoic chamber in the noise experiment. Then, flow characteristics were numerically analyzed by solving the three-dimensional unsteady Navier-Stokes equations and noise analysis was performed by solving the Ffowcs Williams and Hawkins equation with input from the flow simulation results. The validity of numerical results was confirmed by comparing them with the measured ones. Based on the verified numerical method, blade inlet and outlet angles were optimized for maximum flow rate using the two-factor central composite design of the response surface method. Finally, the flow and noise performances of a prototype manufactured with the optimum design were experimentally evaluated, which showed the improvement in flow and noise performance.

Changes in Revised ISO 3741-1999 and Its Application (ISO 3741-1999의 개정 취지와 적용사례)

  • Oh, Yang-Ki
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.206-211
    • /
    • 2000
  • Demands on a quiet environment is increasing because of noisiness and annoyance due to the extended use of noisy electronic device. Determination of sound power levels of noise sources using sound pressure in a reverberation room is usually a relevant method for devices with comparatively large volume or unevenly distributed source position. This study aims to observe the contents of ISO 3741 and analyze its changes in the revised standard ISO 3741-1999. And also aims to assess the revised ISO 1999 its effectiveness and limitations with an actual application to measure the sound power level of a refrigerator.

  • PDF

Design of a Dynamic Absorber Using Permanent Magnet Force (영구자석의 자력을 이용한 동흡진기의 설계)

  • Son, Sol-San;Kim, Won-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.11
    • /
    • pp.1064-1070
    • /
    • 2010
  • In this work, a dynamic absorber with a plate-type cantilever using magnetic force is proposed to reduce the vibration of a compressor directly. The dynamic absorber using magnetic force has some advantages of easily tuning the control frequency by adjusting the magnet spacing and obtaining wider control frequency band. The dynamic absorber is designed theoretically and tested experimentally to estimate the control frequency band. When the compressor is equipped with the dynamic absorber, the vibration of compressor and the noise level of refrigerator are reduced by 30 % and 3.2 dB respectively.

The Characteristics of the Noise of Electric Home Appliances (가전제품의 소음 특성)

  • Gu, Jin-Hoi;Kang, Dae-Joon;Lee, J.W.;Kim, T.S.;Kwon, H.J.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.332-339
    • /
    • 2007
  • As the economy has grown and the main industry in Korea has been changed from secondary industry to tertiary industry, the importance of indoor environment has been a matter of common concern, in which one of the main concerns is to improve the indoor acoustic conditions. However, even though this is required more than before, there are no measures to protect the human being from the noise of electric home appliances. This is owing to the absence of the data about sound power level of electric home appliances. So, we investigate the sound power level of them and analyze the acoustical characteristics of each one. First, we tried to investigate the sound power measurement method of each electric home appliance. After it we test the sound power level of them. From the survey, we can know that the vacuum cleaner is the most noisy electric home appliance, and the refrigerator is the least noisy one. The noise of a range hood is distributed over a wide range frequency. Lastly, we intented to propose the proper method measuring sound power level on each electric home appliance.

  • PDF

Sound Power Level of Electric Home Appliances according to Measurement Method (측정방법별 가전제품의 음향파워레벨)

  • Kang, Dae-Joon;Gu, Jin-Hoi;Lee, Jae-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.4
    • /
    • pp.335-346
    • /
    • 2009
  • As the economy has grown and the main industry in Korea has been changed from secondary industry to tertiary industry, the importance of indoor environment has been a matter of common concern, in which one of the main concerns is to improve the indoor acoustic conditions. However, even though this is required more than before, there are no measures to protect the human being from the noise of electric home appliances. This is owing to the absence of the data about sound power level of electric home appliances. So, we investigate the sound power level of them and analyze the acoustical characteristics of each one. First, we tried to investigate the sound power measurement method of each electric home appliance. After it we test the sound power level of them. From the survey, we can know that the vacuum cleaner is the most noisy electric home appliance, and the refrigerator is the least noisy one. This results will help us predict the indoor noise level using the basic data of sound power level.

Noise-source Identification of Evaporator Using Partial Coherence Function (부분기여도함수를 이용한 증발기의 소음원 분석)

  • Choi, Ki-Soo;Jeong, Wei-Bong;Han, Hyung-Suk;Kim, Min-Seong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.4
    • /
    • pp.347-354
    • /
    • 2009
  • Frequency analysis is one of the most useful way to analyze response signal for the purpose of grasping the dynamic characteristics of system through Fourier transformation. Although it is very effective way for frequency analysis, it is hard to analyze out a specific sound or vibration component which is correlated with others. In this thesis, source contribution analysis tool for NI-PXI equipment is developed with LabVIEW using coherences of MISO(multiple-input single-output) model. For the purpose of examining propriety of developed tool, simulation is performed with several correlated signals that have different frequency range. After checking the OCF(ordinary coherence function) and PCF(partial coherence function) of the each signal for concerned frequency domain, an experiment is conducted on an evaporator that cause the principal noise of a refrigerator. This developed tool will be expected to build up more convenient and serviceable measurement system.

Design of Connecting Part of Linear Compressor to Reduce the Vibration level of 60Hz (선형 압축기의 60Hz 진동저감을 위한 연결부 특성의 설계변경 해석)

  • Jeon, Soo-Hong;Jeong, Weui-Bong;Won, Seong-Gyu;Lee, Hyo-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1360-1365
    • /
    • 2007
  • A linear compressor used in a refrigerator has higher energy efficiency than other compressors. On the other hand, its vibration level has still been much severe. Changing the characteristics of connecting parts may reduce the vibration level of linear compressor. The piston, body and shell are assumed to be rigid. These rigid bodies are connected by coil springs and flexible loop pipe. This paper derived the mathematical model by combining the equation of motion of rigid parts and flexible parts. The variation of vibration level according to the change of connecting parts was investigated.

  • PDF

The Stiffness Analysis and Optimization of the Rubber Seat Considering Nonlinear Behavior (비선형거동을 고려한 방진고무의 강성해석 및 최적설계)

  • Lee, Dong-Hoon;Seo, Sang-Ho;Yun, Young-Hoon;Park, Jin-Goo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.244-249
    • /
    • 2002
  • Rubber seat is extensively used to reduce the vibration of machine or structure. Over the years an enormous effort has been put into developing procedures to provide properties of rubber material for design function. However, there are still a lot of difficulties to analyze static characteristics of rubber components with hyper elasticity and nonlinear large deformation. In this paper material property is obtained by strain-stress curve using a tension test. Mooney-Rivlin Coefficients are gotten by fitting strain-stress curve. The visco-elastic characteristics of refrigerator rubber mount is determined by using ANSYS. And to minimize the rubber stiffness, the rubber seat shape optimization is performed.

  • PDF