• Title/Summary/Keyword: Refrigerator Noise

Search Result 98, Processing Time 0.022 seconds

Signal Analysis of Inverter-Type Outdoor Unit for Detecting Operation Changes of Commercial Refrigerator (상업용 냉장고의 상황 감지를 위한 인버터형 실외기 신호 분석)

  • Lim, Hyo Joon;Lee, Ju Kyoung;Hwang, Jun Hyeon;Lee, Kyung Chang;Lee, Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.6
    • /
    • pp.517-523
    • /
    • 2016
  • Unlike household refrigerators, commercial refrigerators are composed of separate indoor and outdoor units. The outdoor unit of most commercial refrigerators is designed to run at a fixed speed, which results in low energy efficiency and loud fan noise. Moreover, it cannot respond flexibly to changing thermal load in the indoor unit. Inverter type outdoor units can address such problems through speed changes based on information obtained from the indoor unit. However, using two units from different manufacturers is often not a viable solution. If condition changes in the indoor unit can be detected without communication between the two units, it is possible to adjust the speed of the outdoor unit. This paper attempts to analyze the signal from the outdoor unit when the condition of the indoor unit changes by varying the thermal load.

Condition Classification for Small Reciprocating Compressors Using Wavelet Transform and Artificial Neural Network (웨이브릿 변환과 인공신경망 기법을 이용한 소형 왕복동 압축기의 상태 분류)

  • Lim, D.S.;Yang, B.S.;An, B.H.;Tan, A.;Kim, D.J.
    • Journal of Power System Engineering
    • /
    • v.7 no.2
    • /
    • pp.29-35
    • /
    • 2003
  • The monitoring and diagnostics of the rotating machinery have been received considerable attention for many years. The objectives are to classify the machinery condition and to find out the cause of abnormal condition. This paper describes a classification method of diagnosing the small reciprocating compressor for refrigerators using the artificial neural network and the wavelet transform. In order to extract salient features, the wavelet transform are used from primary noise signals. Since the wavelet transform decomposes raw time-waveform signals into two respective parts in the time space and frequency domain, more and better features can be obtained easier than time-waveform analysis. In the training phase for classification, self-organizing feature map(SOFM) and learning vector quantization(LVQ) are applied, and the accuracies of them ate compared with each other. This paper is focused on the development of an advanced signal classifier to automatize the vibration signal pattern recognition. This method is verified by small reciprocating compressors, for refrigerator and normal and abnormal conditions are classified with high flexibility and reliability.

  • PDF

Dynamic Behavior Characteristics of Piston in Reciprocating Compressor (왕복동식 압축기 피스톤의 역학적 거동특성)

  • Cho, Ihnsung
    • Tribology and Lubricants
    • /
    • v.29 no.2
    • /
    • pp.105-110
    • /
    • 2013
  • Refrigeration and air-conditioning compressors used in home appliances, including refrigerators and air conditioners, are typically hermetic-type reciprocating compressors. Because the shell is sealed by welding, it should be designed to have a semi-permanent life. The energy consumption of a hermetic-type reciprocating compressor is low, but because it operates continuously to maintain a constant temperature inside the refrigerator, it has a certain base load. In this type of compressor, the driving motor operates at a high speed (about 3,000 - 3,600 rpm), which causes valve damage, friction, wear, and high-frequency noise. Many studies have been conducted to solve these problems. To enhance the reliability and efficiency of the reciprocating compressor, the design conditions and operating environment of journal bearings should be considered. Dynamic behavior analysis should be carried out in terms of the discharge pressure. The results showed that the load (discharge pressure) increases in the forward lookup zone and decreases in the backward lookup zone. When the revolution speed is increased, the maximum load decreases in the region where the maximum load operates.

A Qualitative Study on the Housework Space Viewed from Housewives and Husbands in Dual-Earner Families (맞벌이 가정의 부부와 남편을 통해 본 가사공간 연구)

  • Jang Sang-Ock
    • Journal of Families and Better Life
    • /
    • v.23 no.6 s.78
    • /
    • pp.1-13
    • /
    • 2005
  • The aim of this study is to investigate the housework space viewed from housewives and husband in dual-earner families. For this study, depth-interview method were used to collects the data. The depth-interview were conducted on the eight heusewives and two husbands in dual-earner families in Jinju and Gwangju in April 2005. The narratives were then analyzed to discover the demands of the kitchen and laundry room. The major results were as follows: 1) Dual-earner families want the kitchen design is they can share housework with their spouses, such as kitchen facing the front side of the floor plan and island counter. In addition, they want spacious, adjustable(flexible), visible storage to enable the housewives to work with their spouse efficiently. Space for Kimchi refrigerator should be considered in the kitchen. 2) They want the noise-free laundry because the interviewers did their laundry work in the night time. Also, they want a multi-purpose laundry mm where machine washing, hand washing, drying and ironing can be done. In addition, for hand-washing wives and husbands, specific space and facilities where they can hand washing on stand posture were needed.

Heat Flow and Cooling Performance of an Electronic Refrigerating Kimchi Jar (전자냉동 김치독의 열유동 및 성능 특성)

  • Song, Kyu-Soek;Kim, Kyung-Hwan;Lee, Seung-Chul;Ko, Chul-Kyun;Lee, Jae-Heon;Oh, Myung-Do
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.7
    • /
    • pp.928-936
    • /
    • 1999
  • The electronic refrigerating kimchi jar operates with a low noise because it contains no compressor but it consumes more energy than that of an refrigerator with compressor. In this paper, the heat flow characteristics and cooling performance of an electronic refrigerating kimchi jar are studied by means of experiments. When the storage temperature is kept in a range of $-5.7^{\circ}C$ to $4.1^{\circ}C$. in the case of three ambient temperatures; $12.7^{\circ}C$, $22.3^{\circ}C$ and $32.2^{\circ}C$, the cooling performance of $20{\ell}$ kimchi jar is investigated. The experiments show that the temperature difference that exists between kimchi jar and its ambient provides a measure of the coefficient of performance of kimchi jar. It is also found that ratio of net pumping heat to the heat pumping rate of thermoelectric module is independent of the temperature difference.

A Study on Forming Analysis for the Roll Forming Process of 3 Point Under Rail (3점 언더레일 슬라이드의 롤포밍 공정에 대한 성형해석연구)

  • Jung, D.W.;Park, S.H.;Jeong, J.H.
    • Journal of Power System Engineering
    • /
    • v.16 no.6
    • /
    • pp.52-58
    • /
    • 2012
  • Roll forming process is one of the most widely used processes in the world for forming metals such as a furniture drawer guide or an up and down slide guide. It can manufacture goods of the uniform cross section on a large scale throughout the continuous processing. In the domestic design and manufacture, roll forming process for production is taking most of the method of 2-point under rail slide. However, this method is vulnerable to the structural strength and stiffness is not suitable for high load conditions. Therefore, through systematic study of high load, low noise 3-point ball type of under rail slide its own design and manufacturing technology is the need to build. In this paper, to make center member of 3-point ball-type under rail slide for the refrigerator doors, the roll forming modeling and simulation are performed. Tensile test is performed about SCP-1 1/2H for determine the mechanical properties of materials. Modeling and simulation of roll forming is used MSC.MARC software of a dedicated analysis program used by rigid plastic finite element method. Interference between the roll and the final shape are predicted from the results of the simulation.

A preliminary study of sound quality evaluation of cochlear implant users (인공와우 사용자의 심리음향적 음질평가 예비연구)

  • Bahng, Junghwa;Oh, Soo Hee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.1
    • /
    • pp.45-51
    • /
    • 2022
  • Sound quality evaluation is one of the psychoacoustic methods to measure subjective judgements for sound color. The purpose of this study is to investigate sound quality benefits of bimodal users by comparing sound quality scores between bimodal hearing condition and unilateral cochlear implant(CI) condition as a preliminary study. Thirteen bimodal users and seven unilateral CI users were participated in this study. Audiologists performed pure tone and speech audiometry and measured functional gain and real-ear insertion gain. Subjective assessment of sound quality was followed with four sounds including violin sound, male and female voices, and refrigerator noise. Participants judged the sound quality with six sound quality index. Bimodal users showed mean 0.8 points more sound quality improvements in bimodal condition than unilateral CI condition. Group comparison between bimodal and unilateral CI users showed no differences. A follow-up study of sound quality tools and methods should be considered to evaluate subjective bimodal benefits of cochlear implant users.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.