R134a용 터보냉동기의 성능시험 (Performance Test of a R134a Centrifugal Water Chiller)

  • 이현구;윤필현;김춘동;이용덕;정진희
    • 설비공학논문집
    • /
    • 제13권5호
    • /
    • pp.333-340
    • /
    • 2001
  • A centrifugal water chiller using alternative refrigerant R134a have been developed. The prototype was designed to have refrigeration capacity of 300RT. Its compressor employs a single high-speed impeller, airfoil diffuser and collector. Newly developed enhanced tubes were installed in the evaporator and the condenser to reduce the required head for the compressor. Off-design characteristics at various conditions, performance test of the compressor and analysis of the refrigeration cycle were performed. So the probability of use in part load condition was checked and the direction for revision was suggested.

  • PDF

증기압축식 에어컨의 냉매 충전량에 따른 성능 예측 (A Theoretical Evaluation of the Effect of Refrigerant Charge on the Performance of Vapor-Compression Air-Conditioning System)

  • 이경중;방광현
    • 설비공학논문집
    • /
    • 제12권5호
    • /
    • pp.486-493
    • /
    • 2000
  • A theoretical model for the transient performance of vapor-compression air-conditioning system has been developed to evaluate the influence of the refrigerant charge on the system performance. A set of mass and energy equations for the simulation of the heat exchangers and the capillary tube and a polytropic compression model for the compressor are used. The present model successfully predicts the transient behavior of the vapor-compression air-conditioner from the startup. As the refrigerant charge is increased, both the evaporating and condensing pressures increase gradually, and the cooling rate and the COP show a maximum in the range of 0.75-0.8 kg of refrigerant charge. This amount of refrigerant mass is determined to be the optimum charge of the model system. Also, the effect of outdoor air temperature on the optimum refrigerant charge is discussed.

  • PDF

Analysis of Oil Behavior inside Rotary Compressor Using Developed Visualization Technique

  • Cho Pil-Jae;Lee Seung-Kap;Youn Young;Ko Han-Seo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권2호
    • /
    • pp.76-83
    • /
    • 2006
  • An efficiency of a refrigeration cycle and a reliability of a compressor can be reduced if a refrigerant including excessive lubricating oil is exhausted from the compressor. Thus, the analysis of the oil behavior inside the compressor is required to prevent the problem. A tested rotary compressor with visualization windows has been manufactured. in this study to investigate the oil behavior using developed visualization techniques. The oil behaviors at various operating conditions have been quantified to obtain the relationship with the outlet pressure inside the compressor. Also, the effect of the operating conditions on the quantity of the exhausted oil from the rotary compressor has been investigated using a manufactured test model.

탄화수소계 냉매 R-290을 사용하는 냉동.공조 장치의 사이클 특성에 관한 연구 (Cycle performance of refrigeration and air-conditioning system using the hydrocarbon refrigerant R-290)

  • 박기원
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권4호
    • /
    • pp.447-452
    • /
    • 1999
  • This paper describes the cycle performance of heat-pump system using R-22 and R-290. Experiments were performed in the smooth tube with inside diameter of 10.07mm and outside diameter of 12.07 mm and grooved inner tube having 75 fins with a height of 0.25mm Condensing temperatures were held constantly between 318K and 328 K while evaporating temperatures were varied from 257 K to 288 K mass velocities from 51 to $280 kg/m^2s$. From the experiments it was known that the evaporating temperature and condensing temperature had more affected by the compressor shaft power than the tube geometries. Cooling capacity of the R-22 and R-290 had similar values in the smooth and grooved inner tubes. The coefficient of performance(COP) was calculated using the compressor shaft power volumetric refrigeration capacity compression ratio and cooling capacity. The COP of the R-290 had slightly higher values than that of R-22 The major parameters affecting the heat pump cycle performance wee the refrigerant proper-ties and operating conditions rather than the geometric shapes of the heat exchanger

  • PDF

초저온 식각을 위한 냉각용량 2kW 급 -100 ℃ 비가연성 혼합냉매 줄톰슨 냉각기의 실험적 고찰 (Experimental Investigation of 2kW Class Non-flammable Mixed Refrigerant Joule-Thomson Refrigerator with Cooling Temperature of -100 ℃ for Cryogenic Etching)

  • 은종민;이천규
    • 반도체디스플레이기술학회지
    • /
    • 제23권2호
    • /
    • pp.6-11
    • /
    • 2024
  • This paper presents the design and experimental analysis of a cryogenic refrigeration system for -100 ℃, primarily intended for semiconductor etching process. The refrigeration system utilizes non-flammable mixed refrigerant Joule-Thomson refrigeration cycle, incorporating a precooling stage to enhance overall performance. The selected refrigerants for the system include R1234yf for the precooling stage, and Ar, R14, R23 and R218 for the main cooling stage of the Joule-Thomson refrigeration cycle. Design results according to the system constraints and experimental results are discussed, including lowest evaporation temperature, compressor isentropic efficiency and overall pressure tendencies. The achieved refrigerant fraction from optimal design is Ar: R14: R23: R218 = 0.15: 0.4: 0.15: 0.3, indicating COP of 0.1118 at the isentropic compressor efficiency of 50%. The experimental result shows the developed system reaches steady state in approximately 3 hours.

  • PDF

Scuffing and Wear of the Vane/Roller Surfaces for Rotary Compressor Depending on Several Sliding Condition

  • Lee, Y.Z.;Oh, S.D.;Kim, J.W.;Kim, C.W.;Choi, J.K.;Lee, I.J.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.227-228
    • /
    • 2002
  • One of the serious challenges in developing rotary compressor with HFC refrigerant is the prediction of scuffing times and wear amounts between vane and roller surface. In this study, the tribological characteristics of sliding surfaces using roller-vane geometry of rotary compressor were investigated. The sliding tests were carried out under various sliding speeds, normal loads and surface roughness. During the tests, friction force, wear scar width, time to failure, surface temperature, and surface roughness were monitored. Because severe wear was occurred on vane surface, TiN coating was applied on sliding surfaces to prolong the wear-life of vane-roller interfaces. From the sliding tests, it was found that there was the optimum initial surface roughness to break in and to prolong the wear life of sliding surfaces. Depending on load and speed, the protective layers, which were composed of metallic oxide and organic compound, were formed on sliding surfaces. Those would play an important role in the amount of friction and wear between roller and vane surfaces.

  • PDF

여러 미끄럼 조건에 따른 로터리 압축기 베인/롤러 표면의 마찰 마멸 특성 (Friction and Wear of the Vane/Roller Surfaces Depending on Several Sliding Condition for Rotary Compressor)

  • 이영제;오세두;김종우;김철우;최진규;조성욱
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.221-226
    • /
    • 2002
  • One of the serious challenges in developing rotary compressor with HFC refrigerant is the prediction of scuffing times and wear amounts between vane and roller surfaces. In this study, the tribological characteristics of sliding surfaces using vane-roller geometry of rotary compressor were investigated. The sliding tests were carried out under various sliding speeds, normal loads and surface roughness. During the test friction force, wear depth, time to failure and surface temperature were monitored. Because severe wear was occurred on vane surface, TiN coating was applied on sliding surfaces to prolong the wear-life of vane-roller interfaces. From the sliding test it was found that there was the optimum initial surface roughness to break in and to prolong the wear life of sliding surfaces. Depending on the load and speed, the protective layers, which were composed of metallic oxide and organic compound, were formed on sliding surfaces. Those would play an important role in role amounts of friction and wear between miler and vane surfaces.

  • PDF

초저온 케스케이드 냉동사이클의 중간압력 및 바이패스 유량 최적화 (Optimization of Middle Pressure and Bypass Mass Flow Rate in Cryogenic Refrigeration Cascade Cycle)

  • 오승택;최원재;이호생;윤정인;유선일;최건형;이상규
    • 동력기계공학회지
    • /
    • 제14권2호
    • /
    • pp.28-33
    • /
    • 2010
  • In this research, cascade liquefaction process was simulated using two-staged direct expansion with inter-cooler. Evaporated gaseous refrigerant which has low pressure and temperature from the inter-cooler is mixed with gaseous refrigerant from outlet of 1st compressor, and flows into 2nd compressor. Therefore this prevents superheating compression. Compressor work of process which includes inter-cooler to all cycles shows the lowest value of 338.68 MW and it is lower 16.34% than that of basic process. Refrigeration capacity shows decreasing tendency as applied inter-cooler and that of process which includes inter-cooler to all cycles shows the lowest value of 449 MW. COP was increased when the inter-cooler was applied, and process which includes inter-cooler to all cycles shows highest value of 1.33. It shows that COP was increased because decrement of compressor work by applying inter-cooler was higher than decrement of refrigeration capacity.

미끄럼 조건에 따른 로터리 압축기 베인/롤러 표면의 마찰 마멸 특성 (Friction and Wear of the Vane/Roller Surfaces Depending on Several Sliding Condition for Rotary Compressor)

  • 오세두;조성욱;이영제
    • Tribology and Lubricants
    • /
    • 제20권6호
    • /
    • pp.337-342
    • /
    • 2004
  • One of the serious challenges in developing rotary compressor with HFC refrigerant is the prediction of scuffing times and wear amounts between vane and roller surfaces. In this study, the tribological characteristics of sliding surfaces using vane-roller geometry of rotary compressor were investigated. The sliding tests were carried out under various sliding speeds, normal loads and surface roughness. During the test, friction force, wear depth, time to failure and surface temperature were monitored. Because severe wear occurred on vane surface, TiN coating was applied on sliding surfaces to prolong the wear life of vane-roller interfaces. From the sliding test it was found that there was the optimum initial surface roughness to break in and to prolong the wear life of sliding surfaces. Depending on the load and speed, the protective layers, which were composed of metallic oxide and organic compound, were formed on sliding surfaces. Those would play an important role in the amounts of friction and wear between roller and vane surfaces.