• 제목/요약/키워드: Refractive coefficient

검색결과 152건 처리시간 0.019초

Optical Constants and Dispersion Parameters of CdS Thin Film Prepared by Chemical Bath Deposition

  • Park, Wug-Dong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권4호
    • /
    • pp.196-199
    • /
    • 2012
  • CdS thin film was prepared on glass substrate by chemical bath deposition in an alkaline solution. The optical properties of CdS thin film were investigated using spectroscopic ellipsometry. The real (${\varepsilon}_1$) and imaginary (${\varepsilon}_2$) parts of the complex dielectric function ${\varepsilon}(E)={\varepsilon}_1(E)+i{\varepsilon}_2(E)$, the refractive index n(E), and the extinction coefficient k(E) of CdS thin film were obtained from spectroscopic ellipsometry. The normal-incidence reflectivity R(E) and absorption coefficient ${\alpha}(E)$ of CdS thin film were obtained using the refractive index and extinction coefficient. The critical points $E_0$ and $E_1$ of CdS thin film were shown in spectra of the dielectric function and optical constants of refractive index, extinction coefficient, normal-incidence reflectivity, and absorption coefficient. The dispersion of refractive index was analyzed by the Wemple-DiDomenico single-oscillator model.

플라즈마 디스플레이 패널의 감광성 격벽을 위한 B2O3-Al2O3-SiO2 유리계의 굴절률과 밀도 (Refractive Indices and Densities of B2O3-Al2O3-SiO2 Glass System for Photosensitive Barrier Ribs of Plasma Display Panel)

  • 원주연;황성진;이상호;김형순
    • 한국전기전자재료학회논문지
    • /
    • 제22권6호
    • /
    • pp.506-511
    • /
    • 2009
  • For the application of the photosensitive barrier ribs with optimal properties such as glass transition temperature, refractive index and coefficient thermal expansion, the boro-silicate glasses was studied. The glass transition temperature, coefficient thermal expansion, and refractive index of the glasses based on the $B_2O_3-Al_2O_3-Al_2O_3-SiO_2$ glass system have been investigated with the different ratio of BaO/$Na_2O$ and $B_2O_3/Na_2O$. Increasing the ratio of $B_2O_3/Na_2O$ was led to the increase of coefficient thermal expansion and the decrease of glass transition temperature. The increase of refractive index of boro-silicate glasses increased with the density of glasses. We suggest the empirical equation for the prediction of refractive index with the glass density, $n=0.123{\rho}+1.182$ with 0.042 as the standard deviation in the boro-silicate glass system. The aim of the present paper is to give a basic result of the thermal and optical properties for designing the composition of photosensitive barrier ribs in PDP.

Measurement of Absorption Coefficient for Quantum Confined Stark Effect In GaAsP/In P MQW Na Refractive Index Change

  • Song, Ju-Bin;Killey, R.
    • Journal of the Optical Society of Korea
    • /
    • 제5권4호
    • /
    • pp.123-130
    • /
    • 2001
  • In this paper, we report measurement of absorption coefficient for various InGaAs MQW QCSE device structures. The absorption spectra over a range of QCSE were obtained from measured photocurrent spectra. The refractive index changes with applied electric field were calculated from the absorption spectra.

Optimization of Thermo-Optic Parameters for Temperature-Insensitive LPWG Refractometers

  • Lee, Dong-Seok;Kim, Kyong-Hon;Hwang, Seok-Hyun;Lee, Min-Hee;Lee, El-Hang
    • ETRI Journal
    • /
    • 제28권6호
    • /
    • pp.739-744
    • /
    • 2006
  • In this paper, we report numerically calculated results of testing a temperature-insensitive refractive sensor based on a planar-type long-period waveguide grating (LPWG). The LPWG consists of properly chosen polymer materials with an optimized thermo-optic coefficient for the core layer in a four-layer waveguide structure. The resonant wavelength shift below the spectral resolution of the conventional optical spectrum analyzer is obtained accurately over a temperature change of ${\pm}7.5^{\circ}C$ even without any temperature control. The refractive index sensitivity of the proposed grating scheme is about 0.004 per resonant wavelength shift of 0.1 nm for an optimized thermo-optic coefficient.

  • PDF

이온교환 평판도파로의 실효굴절율 측정 및 해석 (Analysis and Measurement of Effective Refractive Indices with Ion-exchanged Slab Waveguide)

  • 천석표;박정일;박태성;정홍배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1995년도 춘계학술대회 논문집
    • /
    • pp.73-76
    • /
    • 1995
  • In this study, the slab waveguide was fabricated using potassium-nitride(KNO$_3$) or silver-nitride (AgNO$_3$) molten sources by ion-exchange process. The effective refractive indices of waveguide were measured by Prism-Coupling method. and The characteristics of waveguide(mode dispersion, effective diffusion depth. surface refractive index, diffusion coefficient, and refractive index profile etc,) were investigated by WKB method, In the case of potassium ion-exchange, the computer calculation showed that the refractive index profile of waveguide followed Gaussian function, the surface refractive index increased with ion-exchange time and the effective diffusion depth increased a little as ion-exchange time increased, while the surface refractive index of silver ion-exchanged waveguide decreased with ion-exchange time because of the ion depletion on the surface of waveguide, and the effective diffusion depth seriously with ion-exchange tim. Double ion-exchanged waveguide was fabricated by performing silver ion-exchange after potassium ion-exchange. Double ion-exchanged waveguide had a tight mode binding force since the surface refractive index was larger than single step ion-exchanged waveguide.

  • PDF

Measurement of Thermo-Optic Coefficient of a Liquid Using a Cascade of Two Different Fiber Bragg Gratings

  • Kim, Kwang Taek;Kim, In Soo
    • 센서학회지
    • /
    • 제22권2호
    • /
    • pp.95-99
    • /
    • 2013
  • We proposed and demonstrated a fiber optic sensor for detecting the thermo-optic coefficient of a liquid, based on a cascade of two different FBGs. One of the two FBGs was etched, and its cladding was removed, for evanescent wave coupling with an external liquid. The Bragg wavelength of the non-etched FBG was used as a reference for the temperature of the surrounding liquid. The refractive index (RI) and thermo-optic (T-O) coefficient of a liquid can be detected from the difference between the Bragg wavelengths of the two FBGs, and the variation of the difference in accordance with temperature.

AlF3-(Mg+Sr+Ba)F2-P2O5계 유리에 관한 연구 I. 유리화 범위와 특성 (Studies on AlF3-(Mg+Sr+Ba)F2-P2O5 Glasses I. Glass Forming Ranges of Fluorophosphate System and Its Various Properties)

  • 김정은;이종근
    • 한국세라믹학회지
    • /
    • 제24권2호
    • /
    • pp.117-122
    • /
    • 1987
  • Glass forming ranges in the AlF3-(Mg+Sr+Ba)F2-P2O5 system are studied and ultraviolet transmission, infrared transmission, coefficient of refractive index, thermal expansion coefficient, density and chemical durability of the glasses are determined. Glass forming range is restricted MgF2 0-10wt%, SrF2 10-50wt%, BaF2 10-40wt% in this system. While BaF2 is substituted by SrF2, density and refractive index are decreased, micro hardness and thermal expansion coefficient are increased according to the increasing of SrF2 at fixed MgF2 contents. These samples represent high transmittance(93%) from 400nm to 3800nm and chemical durability of these samples show less than 0.3mg/$\textrm{cm}^2$$.$hy by weightloss.

  • PDF

Refractive Index Modulated Distributed Feedback Laser Diode의 제안과 특성해석 (Proposal and Analysis of Characteristics of a Refractive Index Modulated Distributed Feedback Laser Diode)

  • 김홍국;이홍석;김부균;김병호
    • 전자공학회논문지D
    • /
    • 제36D권5호
    • /
    • pp.88-98
    • /
    • 1999
  • 레이저의 종축방향으로 회절격자층을 형성하는 위쪽 클래딩 층의 가운데 부분의 굴절률을 양 옆부분과 다르게 하여 유효위상천이 효과를 넓은 영역에서 얻는 refractive index midulated (RIM) DFB 레이저를 제안한다.RIM-DFB 레이저는 SHB 효과를 줄이기 위하여 기존에 제안되었던 회절격자의 주기를 변화시켜 넓은 영역에 걸쳐서 유효 위상 천이를 주는 corrugation pitch modualtion (CPM) 방법과 레이저의 종축 방향으로 결합계수를 달리하여 주는 distributed coupling coefficients (DCC) 방법의 효과를 동시에 얻을 수 있는 실현 가능한 구조이다. 급격한 위상천이가 없기 때문에 광자밀도분포가 균일해져 SHB 효과가 줄어 들게 되며 레이저 공진기 가운데 부분의 결합계수가 양 옆 부분의 결합계수보다 커서 분포결합계수의 효과를 주기 때문에λ/4 위상천이 레이저와 CPM-DFB 레이저에 비해 고출력에서 좋은 단일 모드 특성을 보인다. 그리고, 굴절률이 다른 가운데 부분의 길이가 RIM-DFB 레이저의 동작특성에 미치는 영향에 대하여 연구하였다.

  • PDF

집적광학 바이오케미컬 센서에 적합한 Si3N4/SiO2 슬롯 및 릿지-슬롯 광 도파로 제원 최적화 및 감지도 해석 (Specification optimization and sensitivity analysis of Si3N4/SiO2 slot and ridge-slot optical waveguides for integrated-optical biochemical sensors)

  • 장재식;정홍식
    • 센서학회지
    • /
    • 제30권3호
    • /
    • pp.139-147
    • /
    • 2021
  • Numerical analysis was performed using FIMMWAVE to optimize the specifications of Si3N4/SiO2 slot and ridge-slot optical waveguides based on confinement factor and effective mode area. The optimized specifications were confirmed based on sensitivity in terms of the refractive index of the analyte. The specifications of the slot optical waveguide, i.e., the width of the slot and the width and height of the rails, were optimized to 0.2 ㎛, 0.46 ㎛, and 0.5 ㎛ respectively. When the wavelength was 1.55 ㎛ and the refractive index of the slot was 1.3, the confinement factor and effective mode area of 0.2024 and 2.04 ㎛2, respectively, were obtained based on the optimized specifications. The thickness of the ridge and the refractive index of the slot were set to 0.04 ㎛ and 1.1, respectively, to optimize the ridge-slot optical waveguide, and the confinement factor and effective mode area were calculated as 0.1393 and 2.90 ㎛2, respectively. When the confinement coefficient and detection degree of the two structures were compared in the range of 1 to 1.3 of the analyte index, it was observed that the confinement coefficient and sensitivity were higher in the ridge-slot optical waveguide in the region with a refractive index less than 1.133, but the reverse situation occurred in the other region. Therefore, in the implementation of the integrated optical biochemical sensor, it is possible to propose a selection criterion for the two parameters depending on the value of the refractive index of the analyte.