• Title/Summary/Keyword: Reference Sample

Search Result 859, Processing Time 0.027 seconds

Association of vitamin E levels with metabolic syndrome, and metabolic syndrome components among adults (성인의 비타민E 수준에 따른 대사증후군 및 대사증후군 요인과의 연관성)

  • Kim, Taehui
    • Journal of Industrial Convergence
    • /
    • v.19 no.5
    • /
    • pp.69-77
    • /
    • 2021
  • This study identified vitamin E associated with metabolic syndrome and metabolic syndrome components among Korean adults aged over 19 years. Secondary data from the 2016-2018 Korean National Health and Nutrition Examination Survey were used for this study. Data from 6,425 were analyzed by logistic regression analysis using a complex sample procedure. As a result of logistic regression analysis, the odds ratio was increased in the group with high vitamin E levels compared to the group with normal vitamin E levels. There are metabolic syndrome (Adjusted Odds Ratio [AOR]: 1.889, 95% Confidence Interval [CI]: 1.550-2.303, p<.001), abdominal obesity (AOR: 1.444, CI: 1.205-1.730, p<.001), hyperglyceridemia(AOR: 3.182, CI: 2.641-3.835, p<.001), systolic blood pressure (AOR: 1.711, CI: 1.446-2.026, p<.001), diastolic blood pressure (AOR: 1.806, CI: 1.521-2.144, p<.001), low high density lipoprotein cholesterol (AOR: 1.558, CI: 1.060-2.290, p=.024). Therefore vitamin E was associated with metaboic syndrome and metabolic syndrome components. So when providing nursing intervention for people with metabolic syndrome, education on vitamin E should be actively included.

Pupil Data Measurement and Social Emotion Inference Technology by using Smart Glasses (스마트 글래스를 활용한 동공 데이터 수집과 사회 감성 추정 기술)

  • Lee, Dong Won;Mun, Sungchul;Park, Sangin;Kim, Hwan-jin;Whang, Mincheol
    • Journal of Broadcast Engineering
    • /
    • v.25 no.6
    • /
    • pp.973-979
    • /
    • 2020
  • This study aims to objectively and quantitatively determine the social emotion of empathy by collecting pupillary response. 52 subjects (26 men and 26 women) voluntarily participated in the experiment. After the measurement of the reference of 30 seconds, the experiment was divided into the task of imitation and spontaneously self-expression. The two subjects were interacted through facial expressions, and the pupil images were recorded. The pupil data was processed through binarization and circular edge detection algorithm, and outlier detection and removal technique was used to reject eye-blinking. The pupil size according to the empathy was confirmed for statistical significance with test of normality and independent sample t-test. Statistical analysis results, the pupil size was significantly different between empathy (M ± SD = 0.050 ± 1.817)) and non-empathy (M ± SD = 1.659 ± 1.514) condition (t(92) = -4.629, p = 0.000). The rule of empathy according to the pupil size was defined through discriminant analysis, and the rule was verified (Estimation accuracy: 75%) new 12 subjects (6 men and 6 women, mean age ± SD = 22.84 ± 1.57 years). The method proposed in this study is non-contact camera technology and is expected to be utilized in various virtual reality with smart glasses.

Improvement of Acid Digestion Method by Microwave for Hazardous Heavy Metal Analysis of Solid Refuse Fuel (고형연료제품의 유해중금속 분석을 위한 마이크로파 산 분해법의 개선)

  • Yang, Won-Seok;Park, Ho-Yeun;Kang, Jun-Gu;Lee, Young-Jin;Lee, Young-Kee;Yoon, Young-Wook;Jeon, Tae-Wan
    • Journal of Korea Society of Waste Management
    • /
    • v.35 no.7
    • /
    • pp.616-626
    • /
    • 2018
  • The quality standards of solid refuse fuel (SRF) define the values for 12 physico-chemical properties, including moisture, lower heating value, and metal compounds, according to Article 20 of the Enforcement Rules of the Act on Resource Saving and Recycling Promotion. These parameters are evaluated via various SRF Quality Test Methods, but problems related to the heavy metal content have been observed in the microwave acid digestion method. Therefore, these methods and their applicability need improvement. In this study, the appropriate testing conditions were derived by varying the parameters of microwave acid digestion, such as microwave power and pre-treatment time. The pre-treatment of SRF as a function of the microwave power revealed an incomplete decomposition of the sample at 600 W, and the heavy metal content analysis was difficult to perform under 9 mL of nitric acid and 3 mL of hydrochloric acid. The experiments with the reference materials under nitric acid at 600 W lasted 30 minutes, and 1,000 W for 20 or 30 minutes were considered optimal conditions. The results confirmed that a mixture of SRF and an acid would take about 20 minutes to reach $180^{\circ}C$, requiring at least 30 minutes of pre-treatment. The accuracy was within 30% of the standard deviation, with a precision of 70 ~ 130% of the heavy metal recovery rate. By applying these conditions to SRF, the results for each condition were not significantly different and the heavy metal standards for As, Pb, Cd, and Cr were satisfied.

Medical Law Reformation on Korean Medicine Hospitals in the Case of the Jaehan Oriental Medicine Hospital (한방병원에 관한 의료법 개정 : 제한한방병원의 설립과 운영)

  • KEUM, Yujeong;EOM, Dongmyung;SONG, Jichung
    • Journal of Korean Medical classics
    • /
    • v.35 no.1
    • /
    • pp.103-116
    • /
    • 2022
  • Objectives : To look at the medical law reformation of Korean Medicine hospitals through the establishment and management of the Jaehan Oriental Medicine Hospital, which was the first Korean Medicine Hospital in South Korea. Methods : Revisions of the medical law since the establishment of the National Medical Act in 1951 up until 1973 when the 'Korean Medicine hospital' first entered the medical institution category were examined. Based on the revised contents, the establishment and management of the Jaehan hospital were examined. Results & Conclusions : The first mentioning of 'Korean Medicine hospital' in the medical law took place on Feb 16, 1973 when the medical law was completely revised. After law regulations on Korean Medicine hospitals were established, the fist Korean Medicine hospital was founded on Nov. 24th, 1973 according to act 2533 of the medical law. This is the Jaehan Oriental Medicine Hospital, which is the predecessor of what we now know as the Daegu Korean Medicine University Hospital. Although the Jaehan hospital was registered as a legitimate Korean Medicine hospital in November of 1973, it had already started medical practice in December of 1970. While it was established according to the standards of medical law, it changed its institution category from 'Korean Medicine hospital' to 'affiliated Korean Medicine clinic' based on another clause within the same law. The decade from 1960 to 1970 was a time when national economy was developing, and the field of medicine and medical institutions were also booming. As such, revisions in the medical law seems to not have been able to keep up with what was happening in reality. To meet the patients' right to move or to manage diseases which Korean Medicine was taking responsibility for, a medical institution with inpatient capacity was required. Therefore it is possible that the Jaehan hospital which had already been providing such a role could have been a sample case for reference in the medical law revision process.

Current Status of X-ray CT Based Non Destructive Characterization of Bentonite as an Engineered Barrier Material (공학적방벽재로서 벤토나이트 거동의 X선 단층촬영 기반 비파괴 특성화 현황)

  • Diaz, Melvin B.;Kim, Joo Yeon;Kim, Kwang Yeom;Lee, Changsoo;Kim, Jin-Seop
    • Tunnel and Underground Space
    • /
    • v.31 no.6
    • /
    • pp.400-414
    • /
    • 2021
  • Under high-level radioactive waste repository conditions, bentonite as an engineered barrier material undergoes thermal, hydrological, mechanical, and chemical processes. We report the applications of X-ray Computed Tomography (CT) imaging technique on the characterization and analysis of bentonite over the past decade to provide a reference of the utilization of this technique and the recent research trends. This overview of the X-ray CT technique applications includes the characterization of the bentonite either in pellets or powder form. X-ray imaging has provided a means to extract grain information at the microscale and identify crack networks responsible for the pellets' heterogeneity. Regarding samples of pellets-powder mixtures under hydration, X-ray CT allowed the identification and monitoring of heterogeneous zones throughout the test. Some results showed how zones with pellets only swell faster compared to others composed of pellets and powder. Moreover, the behavior of fissures between grains and bentonite matrix was observed to change under drying and hydrating conditions, tending to close during the former and open during the latter. The development of specializing software has allowed obtaining strain fields from a sequence of images. In more recent works, X-ray CT technique has served to estimate the dry density, water content, and particle displacement at different testing times. Also, when temperature was added to the hydration process of a sample, CT technology offered a way to observe localized and global density changes over time.

Acute oral toxicity and bioavailability of uranium and thorium in contaminated soil

  • Nur Shahidah Abdul Rashid;Wooyong Um ;Ibrahim Ijang ;Kok Siong Khoo ;Bhupendra Kumar Singh;Nurul Syiffa Mahzan ;Syazwani Mohd Fadzil ;Nur Syamimi Diyana Rodzi ;Aina Shafinas Mohamad Nasir
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1460-1467
    • /
    • 2023
  • A robust approach was conducted to determining the absolute oral bioavailable (fab) fractions of 238U and 232Th in rats exposed to contaminated soil along with their hematotoxicity and nephrotoxicity. The soil sample is the International Atomic Energy Agency-312 (IAEA-312) certified reference material, whereas blood, bones, and kidneys of in vivo female Sprague-Dawley (SD) rats estimate 238U- and 232Th-fab fractions post-exposure. We predict the bioavailable concentration (Cab) and fab values of 238U and 232Th after acute soil ingestion. The blood 238U (0.750%) and 232Th (0.028%) reach their maximum fab values after 48 h. The 238U (fab: 0.169-0.652%) accumulates mostly in the kidney, whereas the 232Th (fab: 0.004-0.021%) accumulates primarily in the bone. Additionally, 238U is more bioavailable than 232Th. Post 48 h acute ingestion demonstrates noticeable histopathological and hematological alterations, implying that intake of 238U in co-contaminated soil can lead to erythrocytes and proximal tubules damage, whereas, 232Th intake can harm erythrocytes. Our study provides new directions for future research into the health implications of acute oral exposures to 238U and 232Th in co-contaminated soils. The findings offer significant insight into the utilization of in vivo SD rat testing to estimate 238U and 232Th bioavailability and toxicity in exposure assessment.

A simple method to determine lycopene in solid supplementary food preparations using saponification and liquid chromatography (비누화 및 액체크로마토그래프를 활용한 고상 건강기능식품 중 라이코펜 분석법 개발)

  • Young Min Kim;Ye Bin Shin;Min Kyeong Kwon;Jin Hwan Kim;Ji Seong Kim;Dong-Kyu Lee;Myung Joo Kang;Yong Seok Choi
    • Analytical Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.105-112
    • /
    • 2023
  • Lycopene, a carotenoid hydrocarbon is known to have effects on reducing cardiovascular risk factors, blood lipids, and blood pressure. Thus, a lot of supplementary foods with lycopene in several dosage forms like soft capsule filled with liquid and hard capsule filled with powder are available in a market. Recently, however, our research group found that the lycopene assay in Supplementary Food Code of South Korea is only valid for oily lycopene preparation. Thus, here, we developed a simple method to determine lycopene in solid preparations for Supplementary Food Code of South Korea using saponification and liquid chromatography with an absorbance detector. The method was validated following Ministry of Food and Drug Safety guidelines. All validation parameters observed in this study were within acceptable criteria of the guidelines (selectivity, linearity of r2 ≥ 0.991, lower limit of quantification of 0.0149 mg/mL, accuracy as recovery (R) between 92.70 and 97.18 %, repeatability as relative standard deviation (RSD) values of R between 0.85 and 1.59 %, and reproducibility as the RSD value of interlaboratory R of 3.70 %). Additionally, the practical sample applicability of the validated method was confirmed by accuracy between 98.81 and 101.59 % observed from its lycopene certified reference material (CRM) analyses. Therefore, the present method could contribute to fortify the supplementary food safety management system in South Korea.

A Study on the Plan for Wide Road's Streetscape by Simulation of Streetscape's Components - As a Sample Wide Area Road in Busan - (도로경관의 구성요소 제어를 통한 광역도로 경관형성에 관한 연구 - 부산시 광역도로사례를 중심으로 -)

  • Kim, Jong Gu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1D
    • /
    • pp.79-87
    • /
    • 2010
  • The urban street has been escaped from functional and uniformed arrangement for merely movement to the space which can take the role of cozy and familiar culture. Therefore I tried to prepare a plan for the wide roads having streetscape which reveal area's identity as well as coziness and convenience by grasping the problem and its solution through analysing and deducing various elements with the subject of streetscape among urban landscape components, especially composing wide road's streetscape. First of all, this study made a simulation by deducing components of wide road's streetscape and controlling them with theoretical review of streetscape and consideration of wide road's local characteristic. With the evaluation on the base of them, that following four components could be the representative things of entrance part was confirmed by this study. They were familiar streetscape,symbolic scene as as an entrance gate, continuous and dynamic streetscape, and interesting and pleasant streetscape. And for the middle part, those four components could represent the wide road's streetscapeI were confirmed. They were familiar streetscape, safe and tender streetscape, pleasant and dynamic streetscape, and symbolic streetscape. It seems that the components of the streetscape obtained from the analysis of this study are utilized as reference data in the case of a future streetscape design conclusively.

Comprehensive analysis of deep learning-based target classifiers in small and imbalanced active sonar datasets (소량 및 불균형 능동소나 데이터세트에 대한 딥러닝 기반 표적식별기의 종합적인 분석)

  • Geunhwan Kim;Youngsang Hwang;Sungjin Shin;Juho Kim;Soobok Hwang;Youngmin Choo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.4
    • /
    • pp.329-344
    • /
    • 2023
  • In this study, we comprehensively analyze the generalization performance of various deep learning-based active sonar target classifiers when applied to small and imbalanced active sonar datasets. To generate the active sonar datasets, we use data from two different oceanic experiments conducted at different times and ocean. Each sample in the active sonar datasets is a time-frequency domain image, which is extracted from audio signal of contact after the detection process. For the comprehensive analysis, we utilize 22 Convolutional Neural Networks (CNN) models. Two datasets are used as train/validation datasets and test datasets, alternatively. To calculate the variance in the output of the target classifiers, the train/validation/test datasets are repeated 10 times. Hyperparameters for training are optimized using Bayesian optimization. The results demonstrate that shallow CNN models show superior robustness and generalization performance compared to most of deep CNN models. The results from this paper can serve as a valuable reference for future research directions in deep learning-based active sonar target classification.

Dead Layer Thickness and Geometry Optimization of HPGe Detector Based on Monte Carlo Simulation

  • Suah Yu;Na Hye Kwon;Young Jae Jang;Byungchae Lee;Jihyun Yu;Dong-Wook Kim;Gyu-Seok Cho;Kum-Bae Kim;Geun Beom Kim;Cheol Ha Baek;Sang Hyoun Choi
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.129-135
    • /
    • 2022
  • Purpose: A full-energy-peak (FEP) efficiency correction is required through a Monte Carlo simulation for accurate radioactivity measurement, considering the geometrical characteristics of the detector and the sample. However, a relative deviation (RD) occurs between the measurement and calculation efficiencies when modeling using the data provided by the manufacturers due to the randomly generated dead layer. This study aims to optimize the structure of the detector by determining the dead layer thickness based on Monte Carlo simulation. Methods: The high-purity germanium (HPGe) detector used in this study was a coaxial p-type GC2518 model, and a certified reference material (CRM) was used to measure the FEP efficiency. Using the MC N-Particle Transport Code (MCNP) code, the FEP efficiency was calculated by increasing the thickness of the outer and inner dead layer in proportion to the thickness of the electrode. Results: As the thickness of the outer and inner dead layer increased by 0.1 mm and 0.1 ㎛, the efficiency difference decreased by 2.43% on average up to 1.0 mm and 1.0 ㎛ and increased by 1.86% thereafter. Therefore, the structure of the detector was optimized by determining 1.0 mm and 1.0 ㎛ as thickness of the dead layer. Conclusions: The effect of the dead layer on the FEP efficiency was evaluated, and an excellent agreement between the measured and calculated efficiencies was confirmed with RDs of less than 4%. It suggests that the optimized HPGe detector can be used to measure the accurate radioactivity using in dismantling and disposing medical linear accelerators.