• 제목/요약/키워드: Reference Sample

검색결과 859건 처리시간 0.029초

A Cost Effective Reference Data Sampling Algorithm Using Fractal Analysis

  • Lee, Byoung-Kil;Eo, Yang-Dam;Jeong, Jae-Joon;Kim, Yong-Il
    • ETRI Journal
    • /
    • 제23권3호
    • /
    • pp.129-137
    • /
    • 2001
  • A random sampling or systematic sampling method is commonly used to assess the accuracy of classification results. In remote sensing, with these sampling methods, much time and tedious work are required to acquire sufficient ground truth data. So, a more effective sampling method that can represent the characteristics of the population is required. In this study, fractal analysis is adopted as an index for reference sampling. The fractal dimensions of the whole study area and the sub-regions are calculated to select sub-regions that have the most similar dimensionality to that of the whole area. Then the whole area's classification accuracy is compared with those of sub-regions, and it is verified that the accuracies of selected sub-regions are similar to that of whole area. A new kind of reference sampling method using the above procedure is proposed. The results show that it is possible to reduce sampling area and sample size, while keeping the same level of accuracy as the existing methods.

  • PDF

Determination of trace elements in food reference materials by instrumental neutron activation analysis

  • Cho, K.H.;Zeisler, R.;Park, K.W.
    • 분석과학
    • /
    • 제18권6호
    • /
    • pp.520-528
    • /
    • 2005
  • Two biological Certified Reference Materials (CRMs), KRISS 108-04-001 (oyster tissue) and 108-05-001 (water dropwort stem), were prepared by Korea Research Institute of Standards and Science (KRISS)during FY '01. The certified values of these materials had been determined by Isotope Dilution Mass Spectrometry (IDMS) for six elements (Cd, Cr, Cu, Fe, Pb and Zn). Additional analytical works are now progressing to certify the concentrations of a number of the environmental and nutrimental elements in these CRMs. The certified values in a CRM are usually determined by using a single primary method with confirmation by other method(s) or using two independent critically-evaluated methods. Instrumental Neutron Activation Analysis (INAA) plays an important role in the determination of certified values as it can eliminate the possibility of common error sources resulting from sample dissolution. In this study INAA procedure was used in determination of 23 elements in these two biological CRMs to acquire the concentration information and the results were compared with KRISS certified values.

Local Validation of MODIS Global Leaf Area Index (LAI) Product over Temperate Forest

  • Kim, Sun-Hwa;Lee, Kyu-Sung
    • 대한원격탐사학회지
    • /
    • 제19권1호
    • /
    • pp.1-9
    • /
    • 2003
  • MODIS LAI product has been one of key variable for analyzing the quantitative aspects of terrestrial ecology at global scale. This study was designed to validate MODIS global LAI product for regional application. To examine the quality of MODIS LAI data, we developed a reference LAI surface that was derived by relating the ground LAI measurements to Landsat ETM+ reflectance. The study area, the Kwangneung Experiment Forest in Korea, covers mixed deciduous and coniferous species of temperate forest. Ground measurements of LAI were conducted at 30 sample plots by using a photo-optical instrument during the growing season of 2002. Ground measured LAI data were then related to the ETM+ reflectance to produce a continuous map of LAI surface over the study area. From the comparison between the MODIS LAI and the reference LAI, it was found that the MODIS LAI values were slightly higher at the forestland. Considering the limitations of producing the reference LAI surface and the uncertainty of the input variable for the MODIS LAI algorithm, such small discrepancy mal not be significant.

HERETIC-NMR법을 이용한 인의 정량분석 (Quantitative analysis of phosphorus by HERETIC-NMR method)

  • 임헌성;박찬조;이석근
    • 분석과학
    • /
    • 제21권5호
    • /
    • pp.438-441
    • /
    • 2008
  • We have developed an alternative to the internal chemical reference based on a calibrated reference signal which is not a real NMR line but an electronically produced signal (HERETIC) and determined the phosphorus concentration using this method. The area ratio of HERETIC and sample peaks obtained from the standard samples was used to measure the concentrations of different samples directly. The analysis of phosphorus by this method showed the excellent linear regression coefficient ($R^2=0.9999$) for the concentration range from 20 ppm to 500 ppm with HERETIC peak as reference.

A 1.8V 50-MS/s 10-bit 0.18-um CMOS Pipelined ADC without SHA

  • 어지훈;김원영;김상훈;장영찬
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 춘계학술대회
    • /
    • pp.143-146
    • /
    • 2011
  • 본 논문은 1.2Vpp differential 입력 범위를 가지는 50-MS/s 10-hit pipelined ADC를 소개한다. 설계된 pipelined ADC는 8단의 1.5bit/stage, 1단의 2bit/stage와 digital correction 블록, bias circuit 및 reference driver, 그리고 clock generator로 구성된다. 1.5bit/stage는 sub-ADC, DAC, gain stage로 구성된다. 특히, 설계된 pipelined ADC에서는 hardware와 power consumption을 줄이기 위해 SHA를 제거하였으며, 전체 ADC의 dynamic performance를 향상시키기 위해 linearity가 개선된 bootstrapped switch를 사용하였다. Sub-ADC를 위한 reference 전압은 외부에서 인가하지 않고 on-chip reference driver에서 발생시킨다. 제안된 pipelined ADC는 1.8V supply, $0.18{\mu}m$ 1-poly 5-metal CMOS 공정에서 설계되었으며, power decoupling capacitor를 포함하여 $0.95mm^2$의 칩 면적을 가진다. 또한, 60mW의 전력소모를 가진다. 또한, Nyquist sampling rate에서 9.3-bit의 ENOB를 나타내었다.

  • PDF

재조합 사람성장호르몬(소마트로핀)의 KFDA 표준품(KS 98/674) 설정 연구 (Collaborative Study for the Establishment of KFDA Reference Standard for Somatropin (KS 98/674))

  • 신원;정지원;진재호;;손여원
    • 약학회지
    • /
    • 제45권2호
    • /
    • pp.227-236
    • /
    • 2001
  • The complexity and variability of both the biologicals and the bioassays used to test them led to the use of the reference standard- a sample of the product of defined purity and potency, against which all preparations of that product must be calibrated. In order to prepare and establish KFDA reference standard for recombinant human growth hormone (somatropin), somatropin substance was filled in ampoules in National Institute for Biological Standards and Control (NIBSC). The candidate KFDA reference standard for somatropin (designated as 98/674) was evaluated to determine the suitability of serving as a KFDA reference standard for somatropin by the collaborative study, in which 10 laboratories participated. Physicochemical analysis and in vivo bioassay were performed by direct comparison with the international somatropin standard 88/624. 98/674 was identified as somatropin by SDS-PAGE, IEF, peptide mapping, and HPLC. Determination of somatropin content by SE-HPLC yielded a mean estimate of 2.01 mg somatropin per ampoule. Data from the study also yielded mean values of 0.39 $\pm$ 0.26% for high molecular weight impurities by SE-HPLC and mean values of 2.13 $\pm$ 1.29% for somatropin related proteins by RP-HPLC. Estimates of relative potency by weight gain bioassay in the hypophysectomised rats showed that relative potency of KS 98/674 was 1.07 aganist IS 88/624. Based on the results of the collaborative study, the candidate reference standard for somatropin is suitable to serve as a KFDA reference standard for somatropin.

  • PDF

Sample size and statistical power consideration for diagnostic test research

  • Kim, Eu Tteum;Park, Choi Kyu;Pak, Son Il
    • 대한수의학회지
    • /
    • 제48권3호
    • /
    • pp.357-361
    • /
    • 2008
  • Although power analysis is of important tool of research, investigators in veterinary medicine are unaware of the concepts of the statistical power. Two types of error occur in classical hypothesis testing and, those errors should be avoided, if possible. Since power is highly dependent on the sample size, whenever declaring non-statistically significant result they should consider the potential for committing a Type II error in their studies, which refers to the probability of falsely stating that two treatments are equivalent despite true difference between them. Also, sample size determination is one of the most important tasks facing the researcher when planning a diagnostic study, and provides valuable information on the characteristics of a test performance. This type of analysis forms the basis for proper interpretation of test results. The aim of this article was to re-evaluate some selected studies on diagnostic test reported in the domestic veterinary publications to determine the power and necessary sample size for inequality testing to ensure the desired power. Power calculations were illustrated using real-life examples of comparison of a new test and a reference test for detecting antibodies of various animal diseases. Factors affecting to the power were also discussed.

Multi-Level Skip-Lot Sampling Plan

  • Cho, Gyo-Young;Ahn, Young-Sun
    • Communications for Statistical Applications and Methods
    • /
    • 제8권2호
    • /
    • pp.383-394
    • /
    • 2001
  • This paper is a generalization of single and two-level skip-lot sampling plans to n-level. On every skipping inspection of the n-level skip-lot sampling plan, not only the number of consecutive lots to be accepted but also the fraction of lots to be inspected can be freely choosed. The general formulas of the operating characteristic function, average fraction inspected, average sample number and average outgoing quality in n-level skip-lot sampling plan are derived. The operating characteristic curves, average sample number and average outgoing quality of a reference plan, two-level and five-level skip-lot sampling plans are compared.

  • PDF

비디오 영상내의 사람 추적을 위한 강인한 멀티-파트 추적 방법 (A Robust Multi-part Tracking of Humans in the Video Sequence)

  • 김태현;김진율
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 Ⅳ
    • /
    • pp.2088-2091
    • /
    • 2003
  • We presents a new algorithm for tracking person in video sequence that integrates the meanshift iteration procedure into the particle filtering. Utilizing the nice property of convergence to the modes in the meanshift iteration we show that only a few sample points are sufficient, while in general the particle filtering requires a large number of sample points. Multi-parts of a person is tracked independently of each other based on the color Then, the similarity against the reference model color and the geometric constraints between multi-parts are reflected as the sample weights. Also presented is the computer simulation results, which show successful tracking even for complex background clutter.

  • PDF

Comparisons of Various DEM Interpolation Techniques

  • Kim, Tae-Jung
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1998년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.163-168
    • /
    • 1998
  • Extracting a Digital Elevation Model (DEM) from spaceborne imagery is important for cartographic applications of remote sensing data. The procedure for such DEM generation can be divided into stereo matching, sensor modelling and DEM interpolation. Among these, DEM interpolation contributes significantly to the completeness and accuracy of a DEM and, yet, this technique is often considered "trivial". However, na\ulcornere DEM interpolation may result in a less accurate and sometimes meaningless DEM. This paper reports the performance analysis of various DEM interpolation techniques. Using a manually derived DEM as reference, a number of sample points were created randomly. Different interpolation techniques were applied to the sample points to generate DEMs. The performance of interpolation was assessed by the accuracy of such DEMs. The results showed that kriging gave the best results at all times whereas nearest neighborhood interpolation provided a fast solution with moderate accuracy when sample points were large enough.

  • PDF