• 제목/요약/키워드: Reference Sample

검색결과 859건 처리시간 0.024초

Scalable Extension of HEVC for Flexible High-Quality Digital Video Content Services

  • Lee, Hahyun;Kang, Jung Won;Lee, Jinho;Choi, Jin Soo;Kim, Jinwoong;Sim, Donggyu
    • ETRI Journal
    • /
    • 제35권6호
    • /
    • pp.990-1000
    • /
    • 2013
  • This paper describes the scalable extension of High Efficiency Video Coding (HEVC) to provide flexible high-quality digital video content services. The proposed scalable codec is designed on multi-loop decoding architecture to support inter-layer sample prediction and inter-layer motion parameter prediction. Inter-layer sample prediction is enabled by inserting the reconstructed picture of the reference layer (RL) into the decoded picture buffer of the enhancement layer (EL). To reduce the motion parameter redundancies between layers, the motion parameter of the RL is used as one of the candidates in merge mode and motion vector prediction in the EL. The proposed scalable extension can support scalabilities with minimum changes to the HEVC and provide average Bj${\o}$ntegaard delta bitrate gains of about 24% for spatial scalability and of about 21% for SNR scalability compared to simulcast coding with HEVC.

Color Determination of Beef Rib Eye Using Near Infrared Spectroscopy

  • Kang, J.O.;Park, J.Y.;Choy, Y.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제14권2호
    • /
    • pp.263-267
    • /
    • 2001
  • Beef samples of loin eye area from New Zealand, USA and three quality grades of Hanwoo were analyzed using near infrared spectrophotometer with reference values from laboratory optical Chromameter to determine effective spectrum range and mathematical treatment for determination of color values. $R^2s$ of prediction models were not improved much by calibrating with whole light range (400~2500 nm) compared to using visible range (400~1100 nm). Standard errors of calibration and prediction were influenced by possible bias due to sampling non-homogeneous sample sources. However, partial differentiation in the first order was more stable against sampling biases than second derivatives of the spectra. Lightness value was little different among the five sample sources of beef. Beef samples from USA were brighter and more reddish than beefs of Hanwoo or from New Zealand (p<0.05). Yellowness of USA beef was the highest followed by beef from New Zealand, which was also higher than Hanwoo beefs of three quality grades (p<0.05).

생체시료중 수은의 정량을 위한 중성자 방사화분석에 관한 연구 (A Study on the Neutron Activation Analysis for the Determination of Mercury in Biological Samples)

  • 이철;김낙배;이인종
    • 대한화학회지
    • /
    • 제19권3호
    • /
    • pp.163-168
    • /
    • 1975
  • 쌀, 생선 및 표준 기준 배추시료 속에 함유된 수은의 함량을 두 개의 독립적인 분석 방법 즉, 과거 본 연구실에서 개발한 방법과 Sjostrand 방법에 의하여 분석하였다. 분석 결과는 시료의 종류에 따라서 서로 다른 매트릭스 효과를 보였다. 예를 들면 배추과 생선 시료는 같은 매티릭스 효과를 나타내었으나 쌀 시료는 이 두 종의 시료과 비교하여 다른 효과를 보였다.

  • PDF

Determination of the Optical Functions of Various Liquids by Rotating Compensator Multichannel Spectroscopic Ellipsometry

  • Bang, Kyung-Yoon;Lee, Seung-Hyun;Oh, Hye-Keun;An, Il-Sin;Lee, Hai-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권6호
    • /
    • pp.947-951
    • /
    • 2005
  • Rotating compensator multichannel spectroscopic ellipsometry has been employed to determine the optical functions of various liquids used in chemistry. We attempted three different measurement configurations: (1) air-liquid interface, (2) prism-liquid interface, and (3) liquid-sample interface. In prism-liquid interface, we found that the prism surface had roughness and it should be considered in analysis for accurate results. In liquidsample interface, we had much higher reflection, better sensitivity, and less limitation compared to the other two configurations when crystalline silicon was used as reference sample. We discuss the merit of each configuration and present the optical functions of various liquids. Also we demonstrate Bruggeman effective medium theory to determine the optical properties of mixed liquid.

분광학적 방법을 이용한 전혈내의 총 혈색소량 결정 (Determination of Total Hemoglobin in Whole Blood by Spectroscopy)

  • 김연주;윤길원;김원기;김종원
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.251-253
    • /
    • 1996
  • Noninvasive monitoring of total Hemoglobin value is feasible with the use of spectroscopic measurements. As a step toward tile final goal of the development of a noninvasive monitor, the spectra$(400{\sim}800mm)$of EDTA whole blood were obtained along with reference total Hemoglobin values. Under the same condition water spectrum was generated. It was subtracted from each blood sample, and then tile first derivative of each subtracted data was taken by 'approximated first derivative algorithm' with gap (1,6,10,20nm). The correlation was obtained between total Hemoglobin and first valley wavelength of first derivative spectrum (sample number: 93).

  • PDF

원자 현미경 장비의 바닥 진동(정상 상태) 허용 기준 결정 (Determination of the Allowable Vibration Level of the Atomic Force Microscope Equipment)

  • 이동연
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.161-164
    • /
    • 2000
  • Currently, Atomic Force Microscope(AFM) has been widely used to measure the surface topography of a sample by detecting interaction force between atoms on the sample and extremely sharp probe tip. The vertical resolution of AFM is mainly determined by external vibration noise. The resolution of AFM shows different values for the different environment, thus it is necessary to determine relationship between the criteria and the resolution of AFM regardless of environment. In this paper, we discuss the allowable level of floor vibration for AFM equipment at given resolution. The vibration criteria can be used as reference data to design mechanical structure and to analyze the structural dynamics of AFM equipment.

  • PDF

버어리종 담배중 암모니아성 질소에 대한 불확도 측정 (Uncertainty Evaluation of Ammonia Determination in Burley Tobacco)

  • 이정민;이경구;한상빈
    • 한국연초학회지
    • /
    • 제27권1호
    • /
    • pp.107-114
    • /
    • 2005
  • The uncertainty of measurement in quantitative analysis of ammonia by continuous-flow analysis method was evaluated following internationally accepted guidelines. The sources of uncertainty associated with the analysis of ammonia were the weighing of sample, the preparation of extracting solution, the addition of extracting solution into the sample, the reproducibility of analysis and the determination of water content in tobacco, etc. In calculating uncertainties, Type A of uncertainty was evaluated by the statistical analysis of a series of observation, and Type B by the information based on supplier's catalogue and/or certificated of calibration. It was shown that the main source of uncertainty was caused by the volume measurement of 1 mL and 2 mL, the purity of ammonia reference material in the preparation of standard solution, the reproducibility of analysis and the determination of water content of tobacco. The uncertainty in the addition of extraction solution, the sample weighing, the volume measurement of 50 mL and 100 mL, and the calibration curve of standard solution contributed relatively little to the overall uncertainty. The expanded uncertainty of ammonia determination in burley tobacco at $95\%$ level of confidence was $0.00997\%$.

광디스크 드라이브에서 ref_T. E신호 와 샘플펄스 신호를 이용한 평균 탐색시간 개선에 관한 연구 (A study on the improvement of average seek time which use ref_T. E signal and sample pulse signal in optical disk drive)

  • 이시현;김계국;김형래
    • 한국음향학회지
    • /
    • 제14권4호
    • /
    • pp.5-11
    • /
    • 1995
  • 본 논문에서는 광디스크 드라이브가 디스크상의 데이터를 탐색하는데 소요되는 평균탐색 시간 (Average Seek Time)을 개선하기 위한 방법으로 트랙추적 기준신호 (ref_T. E)와 샘플펄스 신호를 사용하여 평균탐색시간을 줄일수 있는 새로운 알고리즘을 제안 하였다. ref_T. E신호와 샘플펄스 신호를 사용하여 트랙을 탐색할 경우 목적트랙으로 이동한 다음 다시 위치를 확인하고 보상할 필요가 없도록하여 평균탐색시간을 개선하였다. 실험결과 28sec의 평균탐색시간을 보였다.

  • PDF

더블 빔 구조, 다파장 분석을 적용한 연속식 실시간 COD 측정 센서 개발 (Development of Continuous Real-time COD Measurement Sensor with Double Beam and Multiple Wavelength Analysis)

  • 이준석;신대정;형기우;류인재
    • 센서학회지
    • /
    • 제23권4호
    • /
    • pp.272-277
    • /
    • 2014
  • At present, the index of chemical oxygen demand (COD) is widely used as an indicator of organic water pollution with biochemical oxygen demand (BOD). But, traditional COD measurement method are not only with various chemical reagents exhausted, but also long time consumed, the operation procedure and the modification are much professional. This paper reported a novel COD measurement system using double-beam and multiple wavelength analysis UV-VIS spectrometries. It consists of pulsed xenon lamp, two-way optical fiber, optical switch, spectrometer and main processor. Proposed COD measurement system obtains any spectral information of water sample (KHP standard sample and two river water and wastewater) and reference sample (distilled water) in the range of 200~520 nm, corresponding to the COD concentration from 0 to 300 mg/L through calculating the UV absorbance. The system show improved precision and can work continuously fast at time interval about 25 seconds.

남한 제3기 분지지역에 대한 고자기 연구 : 3. 정자-울산분지와 그 일원 (Palaeomagnetism of Tertiary Basins in Southern Korea : 3. Chongja-Ulsan Basins and its Vicinities)

  • 손문;강희철;김인수
    • 자원환경지질
    • /
    • 제29권4호
    • /
    • pp.509-522
    • /
    • 1996
  • A total of 460 palaeomagnetic samples was collected from the Tertiary Chongja-Ulsan basins and surrounding area in the southeastern part of Korean peninsula. All samples were stepwise demagnetized by either alternating field or thermal method. It was found that most sample-sites have ChRM declination which has been rotated clockwise from the north-south reference direction of Tertiary East Asia, although other two extrusive sample-sites within the Chongja sedimentary basin show counterclockwise rotation of ChRM declination. Fold tests for the site-mean ChRMs of the latter two sites reveal insignificant result and negative result with 95% confidence level, respectively. The amount of the clockwise deflection of declination varies from about $20^{\circ}$ upto about $80^{\circ}$ according to the block to which each sample-site belongs. The amount of the counterclockwise deflection is about $20^{\circ}$. It is concluded that the clockwise ChRM rotation has been caused by dextral simple shearing accompanied by NNW-SSE spreading of the East Sea which has been active until about 16Ma, and that the counterclockwise rotation is a result of sinistral simple shearing associated with WNW-ESE contraction in the Korean Strait-SW Japan region at about 15 Ma.

  • PDF