• Title/Summary/Keyword: Reference Sample

Search Result 852, Processing Time 0.03 seconds

Effects of the Reference Sample Size on the Performance of the Two-Sample Rank Detector (두 표본 순위 검파에서 기준 표본 크기가 검파기 성능에 미치는 영향)

  • Bae, Jinsoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.8
    • /
    • pp.1515-1517
    • /
    • 2015
  • The effects of the reference sample size on the detection probability of the two-sample rank detector is investigated in this paper. The larger reference sample size shows the better performance of the detector. The effect is also shown to be saturated as the reference sample size becomes larger.

Quality Characteristics of Baked Yugwabandagi with Different Additives (첨가물을 달리한 구운 유과 반대기의 품질 특성)

  • Cha, Kyoung-Ok;Han, Eun-Ju
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.25 no.3
    • /
    • pp.492-501
    • /
    • 2015
  • To improve the shortcomings of baked Yugwa 0.5, 1.0, 1.5 and 2.0% natural ind igestible materials,- (gellan gum, glucomannan and carrageenan) were each treated with glutinous rice-baked Yugwa was processed, and quality imprpvements were deducted. Baked Yugwa with natural additives,- (gellan gum, glucomannan and carrageenan) was compared,- to additional test results with sample 1.5%(w/w) additives,- The one showing the highest preference from the sensory test was the acid number reference group at $2.19{\pm}0.42$, while the sample groups,- with different additives, were lower than the reference group by $1.48{\pm}0.39$ to $1.67{\pm}0.68$. The peroxide number reference group showed the highest preference of $49.34{\pm}0.42$, whereas the sample groups, with different additives, showed lower preferences than the reference group by $36.72{\pm}$0.42 compared to the sample group of glucomannan 1.5% (w/w), $32.45{\pm}0.59$ compared to the sample group of gellan gum 1.5%(w/w), and $28.65{\pm}0.56$ compared to the sample group of carrageenan 1.5% (w/w). According to the preference test targeting employees of Korean cake, manufacturers, there was no significant difference in color and flavor among all groups, whereas the sample group of carrageenan 1.5% (w/w) showed the highest scores in items of taste, texture and overall-preference, and also sample groups of glucomannan 1.5% (w/w) and gellan gum 1.5% (w/w) scored higher than the reference group. Baked Yugwa with 1.5% (w/w) additives of carrageenan, glucomannan and gellan gum have higher marketability by decreasing deterioration caused by oxidation of existing deep fried Yugwa and by improving the solid texture of baked Yugwa.

An Objective Bayesian Inference for the Difference between Two Normal Means

  • Jang, Eun-Jin;Kim, Dal-Ho;Lee, Kyeong-Eun
    • Journal of the Korean Data and Information Science Society
    • /
    • v.17 no.4
    • /
    • pp.1365-1374
    • /
    • 2006
  • In this paper, we consider a decision-theoretic oriented, objective Bayesian inference for the difference between two normal means with known variances. We derive the Bayesian reference criterion as well as the intrinsic estimator and the credible region which correspond to the intrinsic discrepancy loss and the reference prior. We show the similarity between derived two-sample results and the results for the one-sample case in Bernardo(1999).

  • PDF

Tree image comparison analysis using LBP method (LBP 방식을 이용한 나무 영상 비교 분석)

  • Kim, Ji-hong;Lee, Jonghyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.4
    • /
    • pp.530-536
    • /
    • 2021
  • Since the LBP algorithm has the characteristic of local texture expression, it is possible to obtain completely different results depending on the extraction location and the size of the reference image and the sample image. In order to solve these shortcomings, in this paper, we first investigate the basic characteristics of LBP, make the size of the reference image (100×100) in order to include most of the characteristics in the image, and select a sample image (40×40) extracted from an arbitrary point. After finding the matching position in the LBP of the reference image by using the correlation test between the LBP of the reference image and the LBP of the sample image, a chi analysis method is used to find the reference image that most closely matches the sample image.

Study of Cross Correlation Using DRS(Delayed Reference Sample) for Precision Time Measurement of Input Signal on Multilateration (다변측정감시시스템 신호 입력 시각 정밀 측정을 위한 DRS(Delayed Reference Sample)를 이용한 Cross Correlation 방안 연구)

  • Chang, Jae-Won;Lee, Sang Jeong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.3
    • /
    • pp.244-250
    • /
    • 2018
  • Multilateration acquires the transponder signal of target from receivers installed on the ground and calculates the position of the target using the difference of the signal acquisition time of each receiver. One of the factors that influence the positioning accuracy of Multilateration using the TDOA calculation method is the error due to the precision measurement of signal input time. When measuring the signal input time at the receiver, the input signal is sampled using the reference clock of the receiver and a reference sample having the same sampling rate is applied to the cross correlation technique. Therefore, the accuracy of the signal input time is proportional to the reference clock. In this paper, the algorithm for precisely measuring the signal input time by performing cross correlation between the input signal of the receiver and DRS(Delayed Reference Sample) is proposed. In order to verify this, we implemented the pulse signal of the transponder that is transmitted from the target using Matlab. Through the simulation, cross correlation between the proposed DRS and the input signal was performed. From this result, the performance of the precise measurement of signal input time was analyzed.

Post-tuning of Sample Position in Common-path Swept-source Optical Coherence Tomography

  • Park, Jae-Seok;Jeong, Myung-Yung;Kim, Chang-Seok
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.380-385
    • /
    • 2011
  • Common-path interferometers are widely used for endoscopic optical coherence tomography (OCT) because an arbitrary arm length can be chosen for the endoscopic imaging probe. However, the scheme suffers from the limited range of the sample position distance from the end of the imaging probe because the position between the reference reflector and the sample is limited by the optical path-length difference (OPD) to induce an interference signal. In this study, we developed a novel method for compensating the arbitrary sample position in common-path swept-source OCT by adding an extra Mach-Zehnder interferometer in the post-path of the interfered optical signal. Theoretical analysis and an experimental demonstration of imaging depth tuning for the flexible sample position of an endoscopic OCT image are discussed. After post-tuning of sample position distance, the positioning limitation between the reference reflector and the sample can be solved for various sample positions over a range of 26 mm for the cross-sectional images of a fish eye sample.

A Study of Analytical Sensitivity on TDM Test Kit in Clinical Chemistry (약물검사 키트의 분석 민감도에 대한 연구)

  • Chang, Sang Wu;Kim, Nam Yong;Lee, Hee Gyung;Kim, Hyun Jung;Lee, Yun Jung;Jin, Ok Bae;Kim, Mi Gyung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.127-130
    • /
    • 2004
  • Analytical sensitivity on TDM test is the lowest concentration that can be distinguished from background noise. The aim of study was to evaluate analytical sensitivity that is also referred to as the lower limit of detection(LLD) about difference between zero calibrator and isotonic saline sample. We tested for 10 days with zero calibrators and 0.85% saline samples while running trilevel control samples under control. Raw data divided by two groups calculated mean and standard deviation from two sample populations and analytical sensitivity by ${\bar{X}}+2SD$. In comparison with isotonic saline samples and zero calibrators, there were significant differences in phenytoin, phenobarbital and vancomycin, etc. Especially analytical sensitivity on phenytoin is at the same level as the upper limit of analytical measurement range with $40{\mu}g/mL$. We think the cause of this is matrix interference. In conclusion, we were sure that standard protocol for analytical sensitivity as lower limit of analytical measurement range on TDM test must be measured with zero standard rather than an isotonic saline sample and type 1 reagent DW for reducing matrix effects within interactions between different materials in a mixture.

  • PDF

The Test Statistic of the Two Sample Locally Optimum Rank Detector for Random Signals in Weakly Dependent Noise Models (약의존성 잡음에서 두 표본을 쓰는 국소 최적 확률 신호 검파기의 검정 통계량)

  • Bae, Jin-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.8C
    • /
    • pp.709-712
    • /
    • 2010
  • In this paper, the two sample locally optimum rank detector is obtained in the weakly dependent noise with non-zero temporal correlation between noise observations. The test statistic of the locally optimum rank detector is derived from the Neyman-Pearson lemma suitable for the two sample observation models, where it is assumed that reference observations are available in addition to regular observations. Two-sample locally optimum rank detecter shows the same performance with the one-sample locally optimum rank detector asymptotically. The structure of the two-sample rank detector is simpler than that of the one-sample rank detector because the sign statistic is not processed separately.

MergeReference: A Tool for Merging Reference Panels for HLA Imputation

  • Cook, Seungho;Han, Buhm
    • Genomics & Informatics
    • /
    • v.15 no.3
    • /
    • pp.108-111
    • /
    • 2017
  • Recently developed computational methods allow the imputation of human leukocyte antigen (HLA) genes using intergenic single nucleotide polymorphism markers. To improve the imputation accuracy in HLA imputation, it is essential to increase the sample size and the diversity of alleles in the reference panel. Our software, MergeReference, helps achieve this goal by providing a streamlined pipeline for combining multiple reference panels into one.

Two Bayesian methods for sample size determination in clinical trials

  • Kwak, Sang-Gyu;Kim, Dal-Ho;Shin, Im-Hee;Kim, Ho-Gak;Kim, Sang-Gyung
    • Journal of the Korean Data and Information Science Society
    • /
    • v.21 no.6
    • /
    • pp.1343-1351
    • /
    • 2010
  • Sample size determination is very important part in clinical trials because it influences the time and the cost of the experimental studies. In this article, we consider the Bayesian methods for sample size determination based on hypothesis testing. Specifically we compare the usual Bayesian method using Bayes factor with the decision theoretic method using Bayesian reference criterion in mean difference problem for the normal case with known variances. We illustrate two procedures numerically as well as graphically.