The study of Information Systems(IS) is a relatively new discipline area, thus an analysis of the latest research literature could be useful to identify what the researchers are doing and what can be done to improve our discipline. With that purpose in mind, this study analyzes the total 208 articles published in "The Journal of Information Systems~ between 2001 and 2008. The classification system that comprises three key characteristics of diversity (research topic, research method, and reference discipline) was developed based on a review of prior literature. The results of this study were also compared with Kim et al.(2005)'s and Vessey et al.(2002)'s results to identify issues in current Information Systems research and 10 suggest some recommendations for future In formation Systems research. The findings identify popular research topic:s, the dominant research method, and reference discipline. The popular research topics consists of organizational concepts, problem domain-specific concepts, and systems/software management concepts. Field study was characterized as the dominant research method in the papers included in the study. Information Systems itself represents the major theoretical reference of the studies. However, many papers in this study relied on a number of reference disciplines., none of which was dominant, or they did not rely on a specific reference discipline. Finally, this study suggests more research on the disciplinary issues, more training on the research method, more accurate and specific reference discipline, and controlled diversity.
Ahn, Jongsun;Lee, Sangwoo;Heo, Moonbeom;Son, Eunseong;Lee, Young Jae
Journal of Positioning, Navigation, and Timing
/
v.8
no.3
/
pp.129-138
/
2019
In this work, we propose detection method for ionosphere storm that occurs locally using widespread GNSS reference stations. For ionosphere storm detection, we compare ionosphere condition with other reference stations and estimate direction of movement based on ionosphere time variation. The method use carrier phase measurement of dual frequency, for accuracy and precision of test statistics, are evaluated with multiple GNSS reference stations data.
Background: Classical swine fever (CSF) is a severe infectious disease of pigs that causes significant economic losses to the swine industry. Objectives: This study developed a solid-phase blocking enzyme-linked immunosorbent assay (spbELISA) method for the specific detection of antibodies against the CSF virus (CSFV) in porcine serum samples. Methods: A spbELISA method was developed based on the recombinant E2 expressed in Escherichia coli. The specificity of this established spbELISA method was evaluated using reference serum samples positive for antibodies against other common infectious diseases. The stability and sensitivity were evaluated using an accelerated thermostability test. Results: The spbELISA successfully detected the antibody levels in swine vaccinated with the C-strain of CSFV. In addition, the detection ability of spbELISA for CSFV antibodies was compared with that of other commercial ELISA kits and validated using an indirect immunofluorescence assay. The results suggested that the spbELISA provides an alternative, stable, and rapid serological detection method suitable for the large-scale screening of CSFV serum antibodies. Conclusions: The spbELISA has practical applications in assessing the vaccination status of large pig herds.
Yoon, Kaeng Won;Yoon, Suk-Ja;Kang, Byung-Cheol;Kim, Young-Hee;Kook, Min Suk;Lee, Jae-Seo;Palomo, Juan Martin
Imaging Science in Dentistry
/
v.44
no.3
/
pp.207-212
/
2014
Purpose: This study aimed to investigate the deviation of landmarks from horizontal or midsagittal reference planes according to the methods of establishing reference planes. Materials and Methods: Computed tomography (CT) scans of 18 patients who received orthodontic and orthognathic surgical treatment were reviewed. Each CT scan was reconstructed by three methods for establishing three orthogonal reference planes (namely, the horizontal, midsagittal, and coronal reference planes). The horizontal (bilateral porions and bilateral orbitales) and midsagittal (crista galli, nasion, prechiasmatic point, opisthion, and anterior nasal spine) landmarks were identified on each CT scan. Vertical deviation of the horizontal landmarks and horizontal deviation of the midsagittal landmarks were measured. Results: The porion and orbitale, which were not involved in establishing the horizontal reference plane, were found to deviate vertically from the horizontal reference plane in the three methods. The midsagittal landmarks, which were not used for the midsagittal reference plane, deviated horizontally from the midsagittal reference plane in the three methods. Conclusion: In a three-dimensional facial analysis, the vertical and horizontal deviations of the landmarks from the horizontal and midsagittal reference planes could vary depending on the methods of establishing reference planes.
This study addresses the reference spent fuel and its characteristics for developing a geological repository concept. As a disposal capacity of the reference repository system to be developed, spent fuel inventories were projected based on the basis of the Nuclear Energy Plan of the Long-term National Power Program. The reference spent fuel encompassing a variability in characteristics of all existing and future spent fuels of interest was defined. Key parameters in the reference fuel screening processes were the nuclear and mechanical design parameters and the burnup histories for existing spent fuels as of 1996 and for future spent fuels with the more extended burnup the initial enrichment and its expected turnup. The selected reference fuel was characterized in terms of initial enrichment, bumup, dimension, gross weight and age. Also the isotopic composition and the radiological properties are quantitatively identified. This information provided in this study could be used as input for repository system development and performance assessment and applied in fuel material balance evaluation for the various types of back-end fuel cycle studies.
Kim, Se-Kwon;Kim, Jae-Woon;Park, Young-Jin;Lee, Soon-Woo;Kim, Yong-Hwa;Shin, Yo-An
Proceedings of the IEEK Conference
/
2008.06a
/
pp.309-310
/
2008
In this paper, we propose a novel D-ATR (Differential-Average Transmitted Reference) scheme for UWB (Ultra Wide Band) based on impulse radio. The proposed scheme utilizing differential coding at transceiver, does not cause half loss of data rate unlike the conventional TR (Transmitted Reference) and ATR (Average TR) systems which transmit additional reference signals. In addition, the proposed scheme may provide improved BER (Bit Error Rate) performance by averaging the received reference signals like the conventional ATR. The proposed D-ATR receiver produces the averaged reference template by considering both the detected data bit and the differential coding rule.
Background: Although spirometry results can be interpreted differently depending on the reference equation used, there are no established criteria for selecting reference equations as part of the special health examinations for Korean workers. Thus, it is essential to examine the current use of reference equations in Korea, quantify their impact on result interpretation, and propose reference equations suitable for Korean workers, while also considering the environmental conditions of special health examination facilities. Methods: The 213,640 results from the special health examination database were analyzed to identify changes in the ratio of measured values to reference values of lung capacity in Korean workers with changes in age or height, and changes in the agreement of interpretations with the reference equation used. Data from 238 organizations that participated in the 2018-2019 quality control assessment by the Korea Occupational Safety and Health Agency were used to identify the spirometer model and reference equations used in each special health examination facility. Results: Korean special health examination facilities used six reference equations, and the rate of normal or abnormal ventilatory diagnoses varied with the reference equation used. The prediction curve of the Global Lung Function Initiative 2012-Northeast Asian (GLI2012) equation most resembled that of the normal group, but the spirometry model most commonly used by examination facilities was not compliant with the GLI2012 equation. With a scaling factor of 0.95 applied to the Dr. Choi equation, the agreement with the GLI2012 equation was > 0.81 for men and women. Conclusions: We propose the GLI2012 equation as reference equation for spirometry in Korean workers. The GLI2012 equation exhibited the most suitable prediction curve against the normal lung function group. For devices that cannot use the GLI2012 equation, we recommend applying a scaling factor of 0.95 to the Dr. Choi equation.
Our previous study used a bar-type reference mirror to measure the relative distance to the target surface. The target measurement accuracy was required to $1{\mu}m$ PV for aspheric optical surface up to 1m in diameter. Earlier system suffers from the reference surface deformation when the measuring part moves. In order to reduce the deformation, measuring part and the reference part separated from each order in the new design. This system utilizes a kinematic support assembly using invar flexure to minimize the reference surface deformation under gravity and vibration. The surface deformation requirement of reference mirror is defined as of $0.2{\mu}m$ under gravity and 40Hz vibration. The finite element results, shows reference mirror deformation of $0.164{\mu}m$. The first resonance mode was computed to analysis 46.05Hz for reference part and 43.44Hz for measuring part. Thesis satisfies the frequency requirement.
Hantaviruses are etiologic agents of hemorrhagic fever with renal syndrome (HFRS) and hantavirus pulmonary syndrome (HPS) in the world. Various hantaviruses were isolated from HFRS patients and several different rodent species in the world. Four hantavirus isolates from Indonesia and three isolates from Thailand among 89 Bandicotas captured in Yogyakarta, east region of Sumatra island, Indonesia and at Chiang Mai in Thailand during 1996 were made through several passages in Vero E6 cells. Viral genome M segment from two Indonesian isolates and three Thailand isolates were amplified using hantavirus generic primers of the M segment and cloned into pCRII vector. The genetic differences were analyzed by comparison of partial sequence of the M segment and antigenic differences were made by IFA. Nucleotide sequence homology of two isolates BC 8, BC 34 from Indonesia and two isolates thai 1322, thai 1330 to Seoul virus was 99% and 96%, respectively, but Thai 1164 was 80%Thai 1164 strain has shown 95% homology to Thai 749 virus. In conclusion it is indicated that two different serotype hantaviruses, Seoul and Thailand, are cocirculating among Bandicota in Thailand, in contrast Seoul serotype virus is circulating in Indonesia.
Journal of the Korean Society for Library and Information Science
/
v.37
no.4
/
pp.131-149
/
2003
Scientific/technical data whose reliability is authorized have to include physical/chemical constants, authorized property value or authorized scientific statistical values so that the scientists in the same field use them continuously and repeatedly for their research. The data also have to be managed as Standard Reference Data that will be used in other area nationwide by analyzing, evaluating and authorizing the accuracy and reliability of the information with scientific methods. This study suggests a plan for establishing the National Center for Standard Reference Data as well as a necessity for managing the data produced in research process as a national Standard Reference Data. Also, a prototype of research information system for measurement standards is developed and described in detail for research information for measurement standard to be used as a reference data, then a plan to managing national reference data is suggested, in addition.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.