• Title/Summary/Keyword: Reference Monitor

Search Result 235, Processing Time 0.033 seconds

Analysis on the Characteristics of the Landslide in Maeri (III) - With a Special Reference on Slope Stability Analysis - (매리 땅밀림형 산사태(山沙汰)의 발생특성(發生特性)에 관한 분석(分析) (III) - 사면(斜面)의 안정해석(安定解析)을 중심(中心)으로 -)

  • Park, Jae-Hyeon;Choi, Kyung;Bae, Jong Soon;Ma, Ho-Seop;Lee, Jong-Hak;Youn, Ho-Jung
    • Journal of Korean Society of Forest Science
    • /
    • v.94 no.6
    • /
    • pp.377-386
    • /
    • 2005
  • This study was carried out to analyse the landslide characteristics by ground investigation, borehole image processing system, field seismic test, laboratory test and ground stability analysis at the landsliding area occurred in Maeri, Sangdong-myeon, Gimhaesi, Gyeongsangnam-do. Region I needs to install data logger system to monitor a land displacement during the heavy rainfall events because the region can be liable to occur the land slide by land creeping. It is needed to restore rapidly, if the land displacement occurs in Region I. Region II needs to monitor and repair because of the possibility of slope failure by long-term soil loss. Region III needs constructions to remove ground runoff and ground water to be infiltrated from talus. Region IV where is a stable region, needs to be protected from land cutting or other man-made damage.

Development of a Temperature Sensor for OLED Degradation Compensation Embedded in a-IGZO TFT-based OLED Display Pixel (a-IGZO TFT 기반 OLED 디스플레이 화소에 내장되는 OLED 열화 보상용 온도 센서의 개발)

  • Seung Jae Moon;Seong Gyun Kim;Se Yong Choi;Jang Hoo Lee;Jong Mo Lee;Byung Seong Bae
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.56-61
    • /
    • 2024
  • The quality of the display can be managed by effectively managing the temperature generated by the panel during use. Conventional display panels rely on an external reference resistor for temperature monitoring. However, this approach is easily affected by external factors such as temperature variations from the driving circuit and chips. These variations reduce reliability, causing complicated mounting owing to the external chip, and cannot monitor the individual pixel temperatures. However, this issue can be simply and efficiently addressed by integrating temperature sensors during the display panel manufacturing process. In this study, we fabricated and analyzed a temperature sensor integrated into an a-IGZO (amorphous indium-gallium-zinc-oxide) TFT array that was to precisely monitor temperature and prevent the deterioration of OLED display pixels. The temperature sensor was positioned on top of the oxide TFT. Simultaneously, it worked as a light shield layer, contributing to the reliability of the oxide. The characteristics of the array with integrated temperature sensors were measured and analyzed while adjusting the temperature in real-time. By integrating a temperature sensor into the TFT array, monitoring the temperature of the display became easier and more accurate. This study could contribute to managing the lifetime of the display.

Aboveground Net Primary Productivity and Spatial Distribution of Chaco Semi-Arid Forest in Copo National Park, Santiago del Estero, Argentina

  • Jose Luis Tiedemann
    • Journal of Forest and Environmental Science
    • /
    • v.40 no.2
    • /
    • pp.99-110
    • /
    • 2024
  • According to the REDD+ program, it is necessary to monitor, quantify, and report forest conditions in protected land areas. The objectives of this work were to quantify the average monthly aerial net primary productivity (ANPPMONTH) of semi-arid Chaco Forest at Copo National Park (CNP), Santiago del Estero, Argentina, during the period 2000-2023, as well as its spatial distribution and relationship, and its use efficiency (RUE) of average monthly rainfall (AMR). The ANPPMONTH model accounted for 90% of the seasonal variability from October to May, the average seasonal ANPPMONTH was 145 tons of dry matter per hectare (t dm/ha), being the maximum in January with 192 t dm/ha and the minimum in May with 91 t dm/ha. The surface area covered by ANPPMONTH exhibited a consistent positive trend from October to May (t test=15.65, p<0.01). Strong and significant direct relationships were found between ANPPMONTH and AMRs, linear models explaining 90% and 96% of the variability, respectively. The results obtained become reference values for assessing the capacity of the forest systems to stock carbon for global warming mitigation and for monitoring and controlling their response to extreme climatic adversities. The average ANPPMONTH reduces uncertainty when defining the thresholds to monitor and quantify ANPP and forest area, thus facilitating the detection of negative changes in land use in CNP. Such results evidence the National Parks Administration's high effectiveness for the maintenance of protected area and for the high ANPP of the FCHS of CNP in the period 2000-2023.

Correction Factors for Outdoor Concentrations of PM2.5 Measured with Portable Real-time Monitors Compared with Gravimetric Methods: Results from South Korea

  • Yun, Dong-Min;Kim, Myeong-Bok;Lee, Jun-Bok;Kim, Bo-Kyeong;Lee, Dong-Jae;Lee, Seon-Yeub;Yu, Sol;Kim, Sung-Roul
    • Journal of Environmental Science International
    • /
    • v.24 no.12
    • /
    • pp.1559-1567
    • /
    • 2015
  • This study investigated the association between $PM_{2.5}$ concentrations obtained with portable real-time monitors and those obtained with gravimetric methods in national urban air-quality monitoring sites in Seoul, South Korea. We used the SidePak AM510 Personal Aerosol Monitor (TSI Inc., 500 Cardigan Road Shoreview, MN) and DustTrak DRX 8533 (TSI Inc., 500 Cardigan Road Shoreview, MN) as portable real-time monitors for measuring $PM_{2.5}$ concentrations and compared these values with those measured with the PMS-103 or SEQ 47/50 models operated by Federal Reference Method (FRM) or the European Committee for Standardization(ECS), respectively, in national urban air-quality monitoring sites in Seoul. Measurements were conducted every other day in the winter and spring seasons of 2014. The estimated daily mean concentrations of $PM_{2.5}$ ranged between 13.4 and $161.9{\mu}g/m^3$ using AM 510 and between 22.0 and $156.0{\mu}g/m^3$ using DustTrak. The Spearman correlation coefficient for $PM_{2.5}$ concentrations between AM 510 and gravimetric results was 0.99, and the correlation between DustTrak and gravimetric results was 0.87. The correction factor suggested was 0.42 and 0.29 for AM 510 and DustTrak, respectively. We found that $PM_{2.5}$ concentrations measured with real-time monitors could overestimate true $PM_{2.5}$ concentrations and therefore the application of a correction factor (0.43) is strongly suggested for quantification when Real-time monitors were operated of $PM_{2.5}$ levels at urban atmospheric environment of South Korea.

An Efficient Kernel Introspection System using a Secure Timer on TrustZone (TrustZone의 시큐어 타이머를 이용한 효율적인 커널 검사 시스템)

  • Kim, Jinmok;Kim, Donguk;Park, Jinbum;Kim, Jihoon;Kim, Hyoungshick
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.25 no.4
    • /
    • pp.863-872
    • /
    • 2015
  • Kernel rootkit is recognized as one of the most severe and widespread threats to corrupt the integrity of an operating system. Without an external monitor as a root of trust, it is not easy to detect kernel rootkits which can intercept and modify communications at the interfaces between operating system components. To provide such a monitor isolated from an operating system that can be compromised, most existing solutions are based on external hardware. Unlike those solutions, we develop a kernel introspection system based on the ARM TrustZone technology without incurring extra hardware cost, which can provide a secure memory space in isolation from the rest of the system. We particularly use a secure timer to implement an autonomous switch between secure and non-secure modes. To ensure integrity of reference, this system measured reference from vmlinux which is a kernel original image. In addition, the flexibility of monitoring block size can be configured for efficient kernel introspection system. The experimental results show that a secure kernel introspection system is provided without incurring any significant performance penalty (maximum 6% decrease in execution time compared with the normal operating system).

Monitoring Feeding Adequacy in Dairy Cows Using Milk Urea and Milk Protein Contents under Farm Condition

  • Dhali, A.;Mehla, R.K.;Sirohi, S.K.;Mech, A.;Karunakaran, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.12
    • /
    • pp.1742-1748
    • /
    • 2006
  • The experiment was conducted on 264 crossbred Karan-Fries (Holstein Friesian${\times}$Tharparkar) cows, over one year to explore the possibility of using milk urea (MU) concentration and milk protein content to monitor feeding adequacy under farm condition and to investigate the effects of different animal factors and season on MU concentration. Individual noon (1200 to 1300 h) milk samples were collected once in every month and analysed for urea and protein contents. Representative feed samples were also collected on the same day of milk collection and were analysed for CP content. A significant positive association (p<0.01) between MU concentration and milk yield was observed. MU concentrations (mg/dl) were found to be significantly (p<0.01) higher and lower in first lactation (44.8${\pm}$0.7) and in early lactation stage (40.7${\pm}$0.5), respectively. Average MU values were found to be significantly (p<0.01) higher in winter (50.7${\pm}$0.3) and lower in summer (32.9${\pm}$0.6). During the investigation, of the total MU observations, 50.3% were within the range of 30 to 50 mg/dl, 21.4% were <30 mg/dl and only 7.5% were >60 mg/dl. MU concentration was found to be associated significantly (p<0.05) with CP content of forages rather than concentrate. A close positive association (p<0.01) between MU level and daily milk protein (DMP) yield was observed during the investigation. The regression equation, DMP yield (g) = -24.6+33.5 daily milk yield (kg) +0.9 MU (mg/dl) was developed to establish the reference level of DMP yield. The result indicates that the effect of parity and stage of lactation may be ignored while interpreting MU values. However, reference MU values may be standardised separately for high milk yielders as level of milk yield contributes significantly to the variation of MU. The study revealed that the MU values together with DMP yield and milk protein content could be used as a potential non-invasive pointer to monitor feeding adequacy in dairy cows under farm conditions.

Method of BeiDou Pseudorange Correction for Multi-GNSS Augmentation System (멀티 GNSS 보정시스템을 위한 BeiDou 의사거리 보정기법)

  • Seo, Ki-Yeol;Kim, Young-Ki;Jang, Won-Seok;Park, Sang-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.10
    • /
    • pp.2307-2314
    • /
    • 2015
  • This paper focuses on the generation algorithm of BeiDou pseudorange correction (PRC) and simulation based performance verification for design of Differential Global Navigation Satellite System (DGNSS) reference station and integrity monitor (RSIM) in order to prepare for recapitalization of DGNSS. First of all, it discusses the International standard on DGNSS RSIM, based on the interface control document (ICD) for BeiDou, estimates the satellite position using satellite clock offset and user receiver clock offset, and the system time offset between Global Positioning System (GPS) and BeiDou. Using the performance verification platform interfaced with GNSS (GPS/BeiDou) simulator, it calculates the BeiDou pseudorange corrections , compares the results of position accuracy with GPS/DGPS. As the test results, this paper verified to meet the performance of position accuracy for DGNSS RSIM operation required on Radio Technical Commission for Maritime Services (RTCM) standard.

Discussion of Exposure Evaluation Associated with Extremely Low Frequency-magnetic Field in the Case of Portable Hand-held Fans (휴대용 손 선풍기의 극저주파 자기장 발생 수준 평가와 쟁점 고찰)

  • Park, Dong-Uk;Yi, Seongjin;Kim, So-Youn;Bae, Seo-Youn;Choi, Sangjun;Kim, Won;Min, Sung Hyon;Park, Jihoon;Ahn, Jongju
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.5
    • /
    • pp.480-490
    • /
    • 2018
  • Objective: This study aimed to report the level of extremely low frequency-magnetic field (ELF-MF) emitted by portable hand-held fans (HHF) and to discuss the methodologies for determining the health risk of ELF-MF for HHF products. Method: ELF-MF was monitored at eight locations by distances in the vicinity of HHFs. A total of 13 HHF brands on the market were randomly selected. A portable ELF-MF monitor MDEX II was used to measure the ELF-MF level in the range of 40-800 Hz with a resolution of $0.01{\mu}T$. This study also examined the frequency results of a total of 45 HHF products investigated by the Korean Ministry of Science and ICT (KMSICT). Results: ELF-MF higher than $0.3{\mu}T$ was found to be emitted at a distance of less than 20 cm from 12 HHF. ELF-MF emitted from four products was found to exceed the reference level ($83.3{\mu}T$ based on 60 Hz) recommended by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). KMSIT reported that the principle frequency emitted from the HHFs ranged from 54 Hz to 284 kHz, without the level of LEF-MF. Unscientifically, the KMSICT used the reference level by ICNIRP as the chronic level and concluded that all HHFs are safe with a basis of 1.2-36.0% less than the reference level. Conclusion: The HHF emitted much higher levels of ELF-MF than $0.3-0.4{\mu}T$, which is regarded as the reference level for childhood leukemia. The risk of HHF should be examined in terms of whether they can be used by the general public, including children and pregnant woman.

Verification on the Application of Monitoring for Frame Structures Using the VRS-RTK Method through the Free Vibration Test (자유 진동 실험을 통한 VRS-RTK 기법을 이용한 골조 구조물의 모니터링 적용성 검토)

  • Choi, Se-Woon;Park, Hyo-Seon;Kim, Bub-Ryur;Lee, Hong-Min;Kim, You-Sok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.1
    • /
    • pp.174-182
    • /
    • 2014
  • To monitor the wind-induced responses of buildings, conventional real-time kinematic (RTK) methods based on two global positioning system (GPS) receivers (e.g., a reference and a rover) are widely applied. However, these methods can encounter problems such as difficulty in securing and maintaining a space for a reference station. With the recently developed virtual reference station (VRS)-RTK approach, the position of a structure can be measured using only a rover receiver. In this study, to evaluate the applicability of VRS-RTK methods in monitoring the lateral structural responses of frame structures, we performed free vibration tests on a one-story frame model (the first natural frequency of 1 Hz) and a three-story frame model (the first natural frequency of 0.85 Hz). To assess the reliability of the displacement and acceleration responses measured by the GPS, we performed a concurrent measurement using laser displacement sensors and an accelerometer. The accelerometer results were consistent with the GPS measurements in terms of the time history and frequency content. Furthermore, to derive an appropriate sampling rate for the continuous monitoring of buildings, the errors in the displacement responses were evaluated at different GPS sampling rates (5, 10, 20 Hz). The results indicate that as the sampling rate increased, the errors in the displacement responses decreased. In addition, in the three-story model, all modal components (first, second, and third modes) could be recorded at a sampling rate of 20 Hz.

Bioequivalence Assessment of Acephyll® Capsule to Surfolase® Capsule (Acebrophylline HCl 100 mg) by Liquid Chromatography Tandem Mass Spectrometry

  • Nam, Kyung-Don;Seo, Ji-Hyung;Yim, Sung-Vin;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.41 no.5
    • /
    • pp.309-315
    • /
    • 2011
  • A sensitive and specific liquid chromatographic method coupled with tandem mass spectrometry (LC-MS/MS) was developed for the analysis of ambroxol (active moiety of acebrophylline). After acetonitrile precipitation of proteins from plasma samples, ambroxol and the domperidone (internal standard, IS) were eluted on a C18 column. The isocratic mobile phase was consisted of 10 mM ammonium acetate and methanol (10 : 90, v/v), with flow rate at 0.2 mL/min. A tandem mass spectrometer, as detector, was used for quantitative analysis in positive mode by a multiple reaction monitoring mode to monitor the m/z 379.2${\rightarrow}$264.0 and the m/z 426.2${\rightarrow}$175.1 transitions for ambroxol and the IS, respectively. Twenty four healthy Korean male subjects received two capsules (100 mg ${\times}$ 2) of either the test or the reference formulation of acebrophylline HCl in a 2 ${\times}$ 2 crossover study, this was followed by a 1week washout period between either formulation. $AUC_{0-t}$ (the area under the plasma concentration-time curve) was calculated by the linear trapezoidal rule. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. The 90% confidence intervals for the log transformed data were acceptable range of log 0.8 to log 1.25 (e.g., log 0.8964 - log 0.9910 for $AUC_{0-t}$ log 0.8690 - log 1.0750 for $C_{max}$). The major parameters, $AUC_{0-t}$ and $C_{max}$ met the criteria of Korea Food and Drug Administration for bioequivalence indicating that Acephyll$^{(R)}$ capsule (test) is bioequivalent to Surfolase$^{(R)}$ capsule (reference).