• 제목/요약/키워드: Reference Levels

검색결과 958건 처리시간 0.03초

디지털공제프로그램간의 디지털공제영상 비교 (A comparison of subtracted images from dental subtraction programs)

  • 한원정
    • Imaging Science in Dentistry
    • /
    • 제32권3호
    • /
    • pp.147-151
    • /
    • 2002
  • Purpose: To compare the standard deviation of gray levels on digital subtracted images obtained by different dental subtraction programs. Materials and Methods: Paired periapical films were taken at the lower premolar and molar areas of the phantoms involving human mandible. The bite registration group used Rinn XCP equipment and bite registration material, based on polyvinyl siloxane, for standardization. The no bite registration group used only Rinn XCP equipment. The periapical film images were digitized at 1200 dpi resolution and 256 gray levels by a flat bed scanner with transparency unit. Dental digital subtraction programs used for this study were Subtractor (Biomedisys Co., Korea) and Emago (Oral Diagnostic Systems, The Netherlands). To measure the similarities between the subtracted images, the standard deviations of the gray levels were obtained using a histogram of subtracted images, which were then analyzed statistically. Results: Subtracted images obtained by using the Emago program without manual selection of corresponding points showed the lowest standard deviation of gray levels (p<0.01). And the standard deviation of gray levels was lower in subtracted images in the group of a bite registration than in the group of no use of bite registration (p < 0.01). Conclusion: Digital radiographic subtraction without manual selection of reference points was found to be a convenient and superior method.

  • PDF

국내 정밀유도무기 사격시험 결과 기반 신뢰수준 분석 (An Analysis on Confidence Level of Domestic Precision Guided Missile(PGM) based on Live-fire Test Results)

  • 서보길;윤영호;김보람
    • 품질경영학회지
    • /
    • 제48권1호
    • /
    • pp.215-225
    • /
    • 2020
  • Purpose: The purpose of this study was to show current states of domestic Precision Guided Missile(PGM) by analyzing Live-fire test results using general methods to get the Confidence Levels. Methods: Live-fire test results were used to get Confidence Levels of PGM. The Confidence Levels were derived by two general methods. The first method was Binomial distribution and second was convergence of Hypergeometric distribution and Bayes' rule. Results: The results of this study are as follows; The more Live-fire tests of PGM are performed, the higher Confidence Level of PGM will be estimated. And the number of Live-fire tests are related to a unit price of PGM. This results means that the increase of live-fire test, which is useful data for preparation and evaluation of Development Tests / Operation Tests for PGMs, is only way to enhance the Confidence Levels of each PGMs. Conclusion: This study shows the relationship between the Live-fire tests and Confidence Levels of PGMs and it will be used on Live-fire Test & Evaluation of PGMs for reference.

다양한 종에서 하우스키핑 유전자 선택의 중요성 (Importance of Selecting The characterized Housekeeping Genes as Reference Genes in Various Species)

  • 채한화;노윤정;노희종;임다정
    • 한국산학기술학회논문지
    • /
    • 제21권8호
    • /
    • pp.417-428
    • /
    • 2020
  • 하우스키핑 유전자는 에너지생성, 물질합성, 세포사멸 및 세포방어 등과 같은 세포의 기본적인 기능을 수행하기 때문에 모든 유기체의 세포에서 발현된다. 세포의 기본적인 기능을 유지하기 때문에 발현 수준이 상대적으로 일정하여 단백질 발현 및 목적 유전자의 mRNA 발현 분석 등과 같은 유전자 발현 연구에서 기준 유전자로 사용되고 있다. 그러나 이들 유전자의 발현 수준은 조직과 세포마다 다를 수 있으며, 특정 환경 하에서 변할 수 있다. 그러므로 하우스키핑 유전자의 발현 안정성을 탐색하여 유전자 발현 연구에서 최적의 기준 유전자를 선택하는 것이 중요하다. 이 리뷰는 문헌을 통해 인간, 닭, 돼지 그리고 쥐에서 발견된 하우스키핑 유전자를 요약하고, geNorm, NormFinder 그리고 BestKeeper 소프트웨어를 통해 발현 안정성을 추정하였다. 하우스키핑 유전자의 발현 안정성에 대한 탐색은 유전자 발현 연구에서 실험 조건에 따라 가장 적합한 기준 유전자를 선별할 수 있고, 데이터의 정규화를 위해 적용될 수 있다.

2020 한국인 영양소 섭취기준 제·개정: 교훈과 도전 (The development of the 2020 Dietary Reference Intakes for Korean population: Lessons and challenges)

  • 권오란;김혜숙;김정선;황지윤;이정희;윤미옥
    • Journal of Nutrition and Health
    • /
    • 제54권5호
    • /
    • pp.425-434
    • /
    • 2021
  • The discovery of the relationship between nutrients and deficiency diseases during the 100 years from the mid-1800s to the mid-1900s was a breakthrough that led to advances in the study of nutrition. The Recommended Dietary Allowances (RDA) were created as a quantitative standard for avoiding diseases caused by nutrient deficiency. In addition, a reductionism paradigm has become generally accepted among nutrition scholars in health and disease, which focused on the properties of individual nutrients, content in foods, cellular levels, and mechanisms of action. The reductionist paradigm worked very well for the prevention and treatment of malnutrition diseases. However, as the incidence of nutrient deficiencies decreased and that of chronic diseases increased, the nutrition goals have been changed to secure safe and adequate nutrient intake and to reduce chronic disease risks. Accordingly, Dietary Reference Intakes (DRIs), a set of nutrient-based reference values, were designed to replace the RDA. The revised Korean DRIs were published for 40 nutrients in 2020. However, there is still room for improvement in the reference intake levels targeted at reducing the risk of chronic disease. The reductionist approach can no longer be practical because chronic diseases are related to the interactions between multi-components in the foods and multi-targets in the body. Therefore, a second innovative leap is needed following the nutrition development breakthrough made over 100 years ago. To this end, the nutrition paradigm must evolve from reductionism to a holism approach. Cutting-edge scientific technologies, such as metabolomics, transcriptomics, microbiomics, and bioinformatics, should also be acceptable in nutrition science based on the knowledge gained from basic nutrition studies.

Clinical application of anti-M$\ddot{u}$llerian hormone as a predictor of controlled ovarian hyperstimulation outcome

  • Lee, Jae Eun;Lee, Jung Ryeol;Jee, Byung Chul;Suh, Chang Suk;Kim, Ki Chul;Lee, Won Don;Kim, Seok Hyun
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제39권4호
    • /
    • pp.176-181
    • /
    • 2012
  • Objective: In 2009 anti-M$\ddot{u}$llerian hormone (AMH) assay was approved for clinical use in Korea. This study was performed to determine the reference values of AMH for predicting ovarian response to controlled ovarian hyperstimulation (COH) using the clinical assay data. Methods: One hundred sixty-two women who underwent COH cycles were included in this study. We collected data on age, basal AMH and FSH levels, total dose of gonadotropins, stimulation duration, and numbers of oocytes retrieved and fertilized. Blood samples were obtained on cycle day 3 before gonadotropin administration started. Serum AMH levels were measured at a centralized clinical laboratory center. The correlation between the AMH level and COH outcomes and cut-off values for poor and high response after COH was analyzed. Results: Concentration of AMH was significantly correlated with the number of oocytes retrieved (OPU; r=0.700, p<0.001). The mean${\pm}$SE serum AMH levels for poor ($OPU{\leq}3$), normal ($4{\leq}OPU{\leq}19$), and high ($OPU{\geq}20$) response were $0.94{\pm}0.15$ ng/mL, $2.79{\pm}0.21$ ng/mL, and $6.94{\pm}0.90$ ng/mL, respectively. The cut-off level, sensitivity and specificity for poor and high response were 1.08 ng/mL, 85.8%, and 78.6%; and 3.57 ng/mL, 94.4%, and 83.3%, respectively. Conclusion: Our data present clinical reference values of the serum AMH level for ovarian response in Korean women. The serum AMH level could be a clinically useful predictor of ovarian response to COH.

뇨중 연 분석의 정확성 및 정밀성에 미치는 최적 전처리법 (Accuracy and Precision according to Optimal Preparation by Analysis of Urine Lead)

  • 장봉기;정은희;박종안;손부순;이종화
    • 환경위생공학
    • /
    • 제16권1호
    • /
    • pp.91-101
    • /
    • 2001
  • In order to propose a optimum method increasing accuracy and reproducibility in analysis of urine lead levels, we compared matrix modifier addition method and microwave digestion method. The results were as follows ; 1. Where the concentration of $Pd(NO_3)_2$(matrix modifier) was $50mg/{\ell}$, and ashing temperature was $900^{\circ}C$, the results were optimum. In case of matrix modifier addition method, the average coefficient of variation (CV) of normal man was 24.1%, and lead worker was 7.9%. The average urine lead levels of standard were $10.42\mu{g}/{\ell}$ and $19.89\mu{g}/{\ell}$ , the accuracies compared to reference values were 97.0% and 92.6%, respectively. 2. Microwave digestion temperature($160~180^{\circ}C$), time(15~25min) and the ratio of urine/ashing acid(1:1~4:1) did not significantly affect lead absorbance and background absorbance. Therefore we set up a optimum analytical conditions as follows: temperature, $160^{\circ}C$; time, 15min; the ratio of urine/ashing acid, 4:1. after samples were digested by the above analytical conditions, lead absorbance and background absorbance was measured at $450^{\circ}C$ as ashing temperature. The average coefficient of variation (CV) of normal man was 12.4%, and lead worker was 6.2%. The average urine lead levels of standard urine were $10.66\mu{g}/{\ell}$ and $23.31\mu{g}/{\ell}$, the accuracies compared to reference values were 99.3% and 103.9%, respectively. From the results, we suggest that microwave digestion method is a more favorable method than matrix modifier addition method because of easiness to reduce organic matter, possibility to analysis at low temperature and accuracy.

  • PDF

Optimal population size to detect quantitative trait loci in Korean native chicken: a simulation study

  • Nwogwugwu, Chiemela Peter;Kim, Yeongkuk;Cho, Sunghyun;Roh, Hee-Jong;Cha, Jihye;Lee, Seung Hwan;Lee, Jun Heon
    • Animal Bioscience
    • /
    • 제35권4호
    • /
    • pp.511-516
    • /
    • 2022
  • Objective: A genomic region associated with a particular phenotype is called quantitative trait loci (QTL). To detect the optimal F2 population size associated with QTLs in native chicken, we performed a simulation study on F2 population derived from crosses between two different breeds. Methods: A total of 15 males and 150 females were randomly selected from the last generation of each F1 population which was composed of different breed to create two different F2 populations. The progenies produced from these selected individuals were simulated for six more generations. Their marker genotypes were simulated with a density of 50K at three different heritability levels for the traits such as 0.1, 0.3, and 0.5. Our study compared 100, 500, 1,000 reference population (RP) groups to each other with three different heritability levels. And a total of 35 QTLs were used, and their locations were randomly created. Results: With a RP size of 100, no QTL was detected to satisfy Bonferroni value at three different heritability levels. In a RP size of 500, two QTLs were detected when the heritability was 0.5. With a RP size of 1,000, 0.1 heritability was detected only one QTL, and 0.5 heritability detected five QTLs. To sum up, RP size and heritability play a key role in detecting QTLs in a QTL study. The larger RP size and greater heritability value, the higher the probability of detection of QTLs. Conclusion: Our study suggests that the use of a large RP and heritability can improve QTL detection in an F2 chicken population.

Association of Cadmium but not Arsenic Levels in Lung Cancer Tumor Tissue with Smoking, Histopathological Type and Stage

  • Demir, Nalan;Enon, Serkan;Turksoy, Vugar Ali;Kayaalti, Zeliha;Kaya, Seda;Cangir, Ayten Kayi;Soylemezoglu, Tulin;Savas, Ismail
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권7호
    • /
    • pp.2965-2970
    • /
    • 2014
  • Background: To evaluate association of lung cancer with arsenic and cadmium levels measured in tumor tissue. Materials and Methods: Ninety-five patients with lung cancer tumor tissue obtained surgically were included in this study. Arsenic and cadmium levels were measured and levels of metals were compared among types of lung cancer and with reference to patient data. Results: The histopathologic diagnoses of the 95 cases were SCC, 49, adenocarcinoma, 28, large cell, 11 and SCLC, 1. Mean tumor arsenic and cadmium levels were $149.3{\pm}129.1{\mu}g/kg$ and $276.3{\pm}219.3{\mu}g/kg$, respectively. Cadmium levels were significantly associated with smoking (p=0.02), histopathologic type (p=0.005), and TNM staging (r=0.325; p=0.001), although arsenic was not related to any parameter (p>0.05). There was no relation between metal levels and mortality (p>0.05). Conclusions: We found a significant association between tumor cadmium levels of patients with lung cancer and smoking, histopathologic type and staging, although there was no relation with arsenic levels.

Selection of Reliable Reference Genes for Real-time qRT-PCR Analysis of Zi Geese (Anser anser domestica) Gene Expression

  • Ji, Hong;Wang, Jianfa;Liu, Juxiong;Guo, Jingru;Wang, Zhongwei;Zhang, Xu;Guo, Li;Yang, Huanmin
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제26권3호
    • /
    • pp.423-432
    • /
    • 2013
  • Zi geese (Anser anser domestica) belong to the white geese and are excellent layers with a superior feed-to-egg conversion ratio. Quantitative gene expression analysis, such as Real-time qRT-PCR, will provide a good understanding of ovarian function during egg-laying and consequently improve egg production. However, we still don't know what reference genes in geese, which show stable expression, should be used for such quantitative analysis. In order to reveal such reference genes, the stability of seven genes were tested in five tissues of Zi geese. Methodology/Principal Findings: The relative transcription levels of genes encoding hypoxanthine guanine phosphoribosyl transferase 1 (HPRT1), ${\beta}$-actin (ACTB), ${\beta}$-tubulin (TUB), glyceraldehyde-3-phosphate-dehydrogenase (GADPH), succinate dehydrogenase flavoprotein (SDH), 28S rRNA (28S) and 18S rRNA (18S) have been quantified in heart, liver, kidney, muscle and ovary in Zi geese respectively at different developmental stages (1 d, 2, 4, 6 and 8 months). The expression stability of these genes was analyzed using geNorm, NormFinder and BestKeeper software. Conclusions: The expression of 28S in heart, GAPDH in liver and ovary, ACTB in kidney and HPRT1 in muscle are the most stable genes as identified by the three different analysis methods. Thus, these genes are recommended for use as candidate reference genes to compare mRNA transcription in various developmental stages of geese.

Carrier Phase Based Cycle Slip Detection and Identification Algorithm for the Integrity Monitoring of Reference Stations

  • Su-Kyung Kim;Sung Chun Bu;Chulsoo Lee;Beomsoo Kim;Donguk Kim
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제12권4호
    • /
    • pp.359-367
    • /
    • 2023
  • In order to ensure the high-integrity of reference stations of satellite navigation system, cycle slip should be precisely monitored and compensated. In this paper, we proposed a cycle slip algorithm for the integrity monitoring of the reference stations. Unlike the legacy method using the Melbourne-Wübbena (MW) combination and ionosphere combination, the proposed algorithm is based on ionosphere combination only, which uses high precision carrier phase observations without pseudorange observations. Two independent and complementary ionosphere combinations, Ionospheric Negative (IN) and Ionospheric Positive (IP), were adopted to avoid insensitive cycle slip pairs. In addition, a second-order time difference was applied to the IN and IP combinations to minimize the influence of ionospheric and tropospheric delay even under severe atmosphere conditions. Then, the cycle slip was detected by the thresholds determined based on error propagation rules, and the cycle slip was identified through weighted least square method. The performance of the proposed cycle slip algorithm was validated with the 1 Hz dual-frequency carrier phase data collected under the difference levels of ionospheric activities. For this experiment, 15 insensitive cycle slip pairs were intentionally inserted into the raw carrier phase observations, which is difficult to be detected with the traditional cycle slip approach. The results indicate that the proposed approach can successfully detect and compensate all of the inserted cycle slip pairs regardless of ionospheric activity. As a consequence, the proposed cycle slip algorithm is confirmed to be suitable for the reference station where real time high-integrity monitoring is crucial.