• 제목/요약/키워드: Reference Control Scheme

검색결과 522건 처리시간 0.027초

동기형 릴럭턴스 전동기의 단순구조형 센서리스 제어 (A Simplified Sensorless Control of Synchronous Reluctance Motor Using MATLAB)

  • 임진재;김솔;안준선;이주;김윤현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.848-850
    • /
    • 2004
  • Complex sensorless control scheme is difficult to utilize in field of home appliance system because of cost problem. Therefore, it is necessary to introduce simplified sensorless control scheme that is composed of least calculation to estimate the rotor position. This paper presents the principle of the rotor position estimation with comparison of the estimated flux linkage and reference flux linkage. In order to verify the feasibility of control scheme, simulation with MATLAB and experiment is performed.

  • PDF

직렬 능동 보상기의 과전류 보호방법에 관한 연구 (A Study on the Over-Current Protection Method of A Series Active Compensator)

  • 채범석;이우철;이택기;현동석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권6호
    • /
    • pp.321-329
    • /
    • 2002
  • A protection scheme for series active compensator is presented and analyzed in this paper. The proposed series active compensator operated as a high impedance K($\Omega$) to the fundamentals when short-circuit faults occur in the power distribution system, and two control strategies are proposed in this paper The first is the method by detecting the fundamental source current through the p-q theory, the second is the method by detecting the fundamental component of load current in Synchronous Reference Frame(SRF). When the short-circuit faults occur in the power distribution system, the proposed scheme can protect the series active compensator without additional protection circuits. The validity of the Proposed Protection scheme was investigated through experimental results.

3상 무정전 전원장치에 적합한 새로운 구조의 동기좌표계 전압제어기 (Advanced Synchronous Reference Frame Controller for three-Phase UPS Powering Unbalanced and Nonlinear Loads)

  • 현동석;김경환
    • 전력전자학회논문지
    • /
    • 제10권5호
    • /
    • pp.508-517
    • /
    • 2005
  • 본 논문은 LC 필터를 갖는 3상 인버터에 적합한 고성능 전압제어기에 대해서 기술한다. 불평형 부하 및 비선형 부하시 3상 인버터의 출력전압 왜곡을 동시에 보상 할 수 있는 새로운 동기좌표계 전압제어기를 제안한다. 제안된 제어기는 전용의 디지털 필터를 사용하여 불평형 및 비선형 부하 상태하에서도 동기좌표계의 PI 전압제어기가 3상 평형의 선형부하에서와 같이 직류값을 가지고 동작하게 함으로써 비록 전압제어기의 대역폭이 높지 않아도 정상상태 오차를 현격히 감소시킨다. 제안한 제어기의 성능의 타당성을 입증하기 위해서 모의실험 결과를 보였으며 실험을 통하여 모의실험 결과를 확인하였다.

영구자석 표면부착형 동기전동기의 전류제어기를 이용한 센서리스 기동방법 및 속도제어 (Sensorless Speed Control and Starting Algorithm using Current Control of SPM Synchronous Motor)

  • 백인철;이주석;김학원
    • 전력전자학회논문지
    • /
    • 제18권6호
    • /
    • pp.523-529
    • /
    • 2013
  • A sensorless speed control of a permanent magnet synchronous motor(PMSM) which utilizes MRAS based scheme to estimate rotor speed and position is presented. Considering an error between real and estimated rotor position values, a state equation of PMSM in the synchronous d-q reference frame is represented. A state equation of model system which uses estimated speed and nominal parameter values is expressed. To minimize the errors between the derivatives of d-q axis currents of real and model system, MRAS based adaptation mechanisms for the estimation of rotor speed and position are derived. On the other hand, for the acceleration stage of motor just before the sensorless operation, an acceleration scheme using only d-axis current control is proposed. To show the validity of the proposed scheme, experimental works are carried out and evaluated. During acceleration stage, the acceleration scheme using only d-axis current command shows good acceleration performance and controlled current level. For the sensorless operation, at low speed (5% of rated speed), a good performance is observed.

고 전력 응용을 위한 유도가열 Jar용 Active-Clamped Class-E 인버터 시스템의 새로운 Hybrid 제어 기법 (A New Hybrid Control Scheme with Active-Clamped Class-E Inverter system of Induction Heating Jar for High Power Applications)

  • 이동윤;이민광;현동석;김정철;최익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1009-1011
    • /
    • 2001
  • This paper presents a new hybrid control scheme using Active-Clamped Class-E (ACCE) inverter of induction heating(IH) jar for high power applications. The proposed hybrid control scheme has characteristics, which act as class-E inverter at lower switch voltage and ACCE inverter at higher switch voltage than reference voltage of the main switch by feeding back voltage one as well as advantages of conventional ACCE inverter such as zero-voltage switching(ZVS) of the main switch and the reduced switch voltage due to the clamping circuit. Moreover, the proposed control method makes higher output power than conventional ACCE inverter control one since ACCE inverter is operated like class-E inverter at low voltage condition. The principle of the proposed control are explained in detail and the validity of the proposed control scheme is verified through the several interesting simulated and experimental results.

  • PDF

일반화최소분산 적응제어를 이용한 유압 서보계의 특성개선에 관한 연구 (Characteristics Improvement of Hydraulic Servosystem by Using Generalized Minimum Variance Adaptive Control)

  • 박용호;김기홍;이진걸
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권3호
    • /
    • pp.388-394
    • /
    • 2003
  • Hydraulic system is difficult to obtain a suitable performance due to the nonlinearity load pressure change and system parameter variation. The requirement of control a1gorithm has been complex in order to satisfy the performance. The adaptive control is a control method which is suggested to achieve the control object under the plant characteristics change. In spite of the case that plant characteristics and the degree of variation are difficult to grasp. the adaptive control could keep the characteristics of closed-loop system generally. In this study. a method of combined generalized minimum variance adaptive control (GMVAC) and output error feedback is proposed, in order to solve the problem of non-minimum phase of plant and the vibration and overshoot in initial response. The control performance according to the variation of characteristics of plant is evaluated by changing the supply pressure. The experimental results show the effectiveness of the proposed scheme.

A Novel Fast Open-loop Phase Locking Scheme Based on Synchronous Reference Frame for Three-phase Non-ideal Power Grids

  • Xiong, Liansong;Zhuo, Fang;Wang, Feng;Liu, Xiaokang;Zhu, Minghua;Yi, Hao
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1513-1525
    • /
    • 2016
  • Rapid and accurate phase synchronization is critical for the reliable control of grid-tied inverters. However, the commonly used software phase-locked loop methods do not always satisfy the need for high-speed and accurate phase synchronization under severe grid imbalance conditions. To address this problem, this study develops a novel open-loop phase locking scheme based on a synchronous reference frame. The proposed scheme is characterized by remarkable response speed, high accuracy, and easy implementation. It comprises three functional cascaded blocks: fast orthogonal signal generation block, fast fundamental-frequency positive sequence component construction block, and fast phase calculation block. The developed virtual orthogonal signal generation method in the first block, which is characterized by noise immunity and high accuracy, can effectively avoid approximation errors and noise amplification in a wide range of sampling frequencies. In the second block, which is the foundation for achieving fast phase synchronization within 3 ms, the fundamental-frequency positive sequence components of unsymmetrical grid voltages can be achieved with the developed orthogonal signal construction strategy and the symmetrical component method. The real-time grid phase can be consequently obtained in the third block, which is free from self-tuning closed-loop control and thus improves the dynamic performance of the proposed scheme. The proposed scheme is adaptive to severe unsymmetrical grid voltages with sudden changes in magnitude, phase, and/or frequency. Moreover, this scheme is able to eliminate phase errors induced by harmonics and random noise. The validity and utility of the proposed scheme are verified by the experimental results.

전자 유압식 후륜 조향 장치의 응답 특성 개선에 관한 연구 (A Study on the Improvement of the Response Characteristic of the Electro-Hydraulic Rear Wheel Steering Gear)

  • 오인호;양경욱;이일영
    • 한국자동차공학회논문집
    • /
    • 제5권6호
    • /
    • pp.192-201
    • /
    • 1997
  • The feedback control scheme of the pressure control system of the rear wheel steering gear which has relatively large volume and sprung load was built up in order to improve th response characteristic of the system. The control algorithm chosen was a feedback compensator joined by a feedfoward compensator and the model matching method was used in the process of control system design. The structures and properties of the reference models were inspected and the parameters of the controller were decided. The improvement of the response characteristic of the pressure control valve by means of the feedback control is affirmed. Particularly, when the order of the system model is higher than the 2nd order, the effectiveness of the feedback control on the improvement of the response characteristic of the valve is distinct. And the convenience of the model matching method is the process of control system design is confirmed as well.

  • PDF

On-line Frequency Estimation Based on Cascade Adaptive Notch Filter and Application to Active Noise Control

  • Kim, Sunmin;Park, Youngjin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1998년도 제13차 학술회의논문집
    • /
    • pp.81-84
    • /
    • 1998
  • For ANC systems applied to aircrafts or passenger ships, engines from which reference signals are usually measured are located so far from seats where main part of controllers are placed. It can make feedforward ANC scheme difficult to implement or very costly. Feedback ANC algorithms which do not require reference signals and use error signals alone to update the filter, are usually sensitive to measurement noise ' and impulse noise. In this paper, reference signal needed for the feedforward control is not measured directly but generated with the estimated frequencies. Cascade adaptive notch filter (ANF), which has the low computational burden, is used to implement ANC system in real time. Several ANFs of order 2 are connected in series to estimate multiple sinusoids. Computer simulations and experiments in the laboratory for verifying efficacy of the proposed algorithm are carried out.

  • PDF

Control Strategy for Selective Compensation of Power Quality Problems through Three-Phase Four-Wire UPQC

  • Pal, Yash;Swarup, A.;Singh, Bhim
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.576-582
    • /
    • 2011
  • This paper presents a novel control strategy for selective compensation of power quality (PQ) problems, depending upon the limited rating of voltage source inverters (VSIs), through a unified power quality conditioner (UPQC) in a three-phase four-wire distribution system. The UPQC is realized by the integration of series and shunt active power filters (APFs) sharing a common dc bus capacitor. The shunt APF is realized using a three-phase, four-leg voltage source inverter (VSI), while a three-leg VSI is employed for the series APF of the three-phase four-wire UPQC. The proposed control scheme for the shunt APF, decomposes the load current into harmonic components generated by consumer and distorted utility. In addition to this, the positive and negative sequence fundamental frequency active components, the reactive components and harmonic components of load currents are decomposed in synchronous reference frame (SRF). The control scheme of the shunt APF performs with priority based schemes, which respects the limited rating of the VSI. For voltage harmonic mitigation, a control scheme based on SRF theory is employed for the series APF of the UPQC. The performance of the proposed control scheme of the UPQC is validated through simulations using MATLAB software with its Simulink and Power System Block set toolboxes.