• 제목/요약/키워드: Reference Compensation Voltage

검색결과 177건 처리시간 0.021초

전력 품질 향상을 위한 배전용 STATCON의 AC전압, 직류결합 전압 및 고조파 보상 제어알고리즘 개발 (The Development of Control Algorithms of D-STATCON for Compensations of AC Voltage and DC Link Voltage and Harmonics Improve the Qeality of Electric Power)

  • 오관일;전영수;이기선;추진부
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.333-337
    • /
    • 1999
  • This paper presents the DQ transfomation space space vector modulation method to devel control algorithm of distribu STATCON(STATic CONdenser) for line volt regulation, dc link voltage regulation harmonics compensation. The Performance an of a PI with ramp comparision and synchro reference frame current controller is carried Based on these analysis, the control perform are desirable to compensate the harmonics a regulate dc link and line voltage of Distrib line.

  • PDF

Harmonic Current Compensation based on Three-phase Three-level Shunt Active Filter using Fuzzy Logic Current Controller

  • Salim, Chennai;Benchouia, M.T.;Golea, A.
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권5호
    • /
    • pp.595-604
    • /
    • 2011
  • A three-phase three-level shunt active filter controlled by fuzzy logic current controller which can compensate current harmonics generated by nonlinear loads is presented. Three-level inverters and fuzzy controllers have been successfully employed in several power electronic applications these past years. To improve the conventional pwm controller performance, a new control scheme based on fuzzy current controller is adopted for three-level (NPC) shunt active filter. The scheme is designed to improve compensation capability of APF by adjusting the current error using a fuzzy rule. The inverter current reference signals required to compensate harmonic currents use the synchronous reference detection method. This technique is easy to implement and achieves good results. To maintain the dc voltage across capacitor constant and reduce inverter losses, a proportional integral voltage controller is used. The simulation of global system control and power circuits is performed using Matlab-Simulink and SimPowerSystem toolbox. The results obtained in transient and steady states under various operating conditions show the effectiveness of the proposed shunt active filter based on fuzzy current controller compared to the conventional scheme.

전원 전압의 불평형과 고조파 전류 보상 및 역률 개선 기능을 가지는 능동전력 필터 (Active Power Filter Compensating for Source Voltage Unbalance/Current Harmonics and Power Factor Correction)

  • 이종건;석줄기;이동춘
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.787-790
    • /
    • 2004
  • In this paper, a novel control scheme compensating for source voltage unbalance and current harmonics and power factor correction in unified active power filter systems combined with shunt passive filters is proposed, where no low/high-pass filter are used in deriving the reference voltage for compensation. Using digital all-pass filters, the phase angle and the reference voltages compensating for harmonic current and unbalanced voltage are derived from the positive sequence component of the unbalanced voltage. The amplitude of d-axis current in a series filter is controlled as zero for power factor correction. The validity of the proposed control scheme has been verified by experimental results.

  • PDF

전원 전압의 불평형과 고조파 전류 및 역률을 동시에 보상하는 통합형 능동 전력필터 (Unified Active Power Filter Compensating For Source Voltage Unbalance/Current Harmonics and Power Factor Simultaneously)

  • 이종건;석줄기;이동춘
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.103-105
    • /
    • 2004
  • In this paper, a novel control scheme compensating for source voltage unbalance and current harmonics and power factor simultaneously in unified active power filter systems combined with shunt passive filters is proposed, where no low/high-pass filter are used in deriving the reference voltage for compensation. Using digital all-pass filters, the phase angle and the reference voltages compensating for harmonic current and unbalanced voltage are derived from the positive sequence component of the unbalanced voltage. The amplitude of d-axis current in a series filter is controlled as zero for power factor correction. The validity of the proposed control scheme has been verified by experimental results.

  • PDF

왜곡된 전원 전압 하에서 삼상 PWM 컨버터의 전류 보상 기법 (Current Compensation Method of a Three Phase PWM Converter under Distorted Source Voltages)

  • 박내춘;목형수;지준근;김상훈
    • 전력전자학회논문지
    • /
    • 제13권5호
    • /
    • pp.352-359
    • /
    • 2008
  • 본 논문에서는 왜곡된 전원전압 하에서 삼상 PWM 컨버터의 전류 보상 기법을 제안하였다. PWM 컨버터의 제어에 있어서 전원단 전압의 정확한 위상각 정보는 필수적이다. 동기좌표계 PLL 기법을 이용하여 고조파 전압이 포함되어 있는 전원단의 위상각을 검출하는 경우 전원 전압의 고조파로 인해 왜곡된 위상각을 얻게 된다. 이러한 왜곡된 위상각으로 컨버터를 제어하는 경우 입력 전류는 순수 정현파가 되지 않고 고조파가 포함된다. 본 논문에서는 왜곡된 전원단 전압 조건에 대해서도 입력 전류의 고조파를 IEEE Std. 519 규정인 5% 이내로 제한할 수 있도록 하는 전류 보상기법을 제안하였다. 시뮬레이션과 실험을 통하여 제안된 기법의 타당성을 검증하였다.

Control Strategy for Selective Compensation of Power Quality Problems through Three-Phase Four-Wire UPQC

  • Pal, Yash;Swarup, A.;Singh, Bhim
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.576-582
    • /
    • 2011
  • This paper presents a novel control strategy for selective compensation of power quality (PQ) problems, depending upon the limited rating of voltage source inverters (VSIs), through a unified power quality conditioner (UPQC) in a three-phase four-wire distribution system. The UPQC is realized by the integration of series and shunt active power filters (APFs) sharing a common dc bus capacitor. The shunt APF is realized using a three-phase, four-leg voltage source inverter (VSI), while a three-leg VSI is employed for the series APF of the three-phase four-wire UPQC. The proposed control scheme for the shunt APF, decomposes the load current into harmonic components generated by consumer and distorted utility. In addition to this, the positive and negative sequence fundamental frequency active components, the reactive components and harmonic components of load currents are decomposed in synchronous reference frame (SRF). The control scheme of the shunt APF performs with priority based schemes, which respects the limited rating of the VSI. For voltage harmonic mitigation, a control scheme based on SRF theory is employed for the series APF of the UPQC. The performance of the proposed control scheme of the UPQC is validated through simulations using MATLAB software with its Simulink and Power System Block set toolboxes.

전원전압의 불평형 및 왜곡 보상기능을 갖는 3상 PWM 정류기의 전류제어기 (A Current Controller with the Compensation of the Input Voltage Unbalance and Distortion for Three Phase PWM Rectifier)

  • 신근희;김학원;조관열;임병국
    • 전력전자학회논문지
    • /
    • 제16권6호
    • /
    • pp.594-601
    • /
    • 2011
  • 본 논문은 상용의 전원 전압이 불평형 및 왜곡을 갖는 경우, 전원전압 불평형 및 왜곡 보상기능을 갖는 전류제어기를 제안한다. 일반적으로 3상 전원 시스템은 공통 입력 단자 (Point of Common Coupling)에 단상 부하 및 비선형 부하가 3상 부하와 같이 연결될 수 있어, 종종 불평형과 왜곡이 발생한다. 이런 조건하에서 3상 PWM 정류기를 일반적인 전류 제어기로 제어 할 경우, 3상 PWM 정류기 입력 전류가 불평형 및 왜곡을 갖는 문제가 발생한다. 본 논문에서는 간단한 모델 기반 적응 제어 시스템(Model Reference Adaptive System)기법을 이용하여 3상 입력 전압의 불평형 및 왜곡을 관측하고 전향 보상하는 전류 제어기를 제안하며, 모의해석과 실험을 통하여 그 효용성을 입증한다.

능동필터형 쌍방향 UPS의 새로운 제어기법 (A novel control strategy of active power filter type bidirectional UPS)

  • 김제흥;염상구;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2082-2084
    • /
    • 1997
  • This paper proposes a new control strategy of bidirectional uninterruptible power supply(UPS) with the performance of active power filter which compensate the harmonics and reactive power. To improve the transient response for the effective compensation in active power filter mode, it is considered that a simple and precise calculation method of the compensation reference current for the harmonics and reactive power compensation. So a novel closed-loop control strategy is used to calculate the reference current. And the current regulated instantaneous voltage control scheme is used in back-up power mode. The system model and control algorithm are described and analyzed, and the system Performance is verified by the simulation and experimental results.

  • PDF

모드절환식 다기능 무정전 전원장치 (Multifunctional UPS with Mode Transfer Method)

  • 김제흥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1049-1051
    • /
    • 2001
  • This paper proposes a new control strategy of multifunctional uninterruptible power supply(UPS) with the performance of active power filter which compensate the harmonics and reactive power. To improve the transient response for the effective compensation in active power filter mode, it is considered that a simple and precise calculation method of the compensation reference current for the harmonics and reactive power compensation. So a novel closed-loop control strategy is used to calculate the reference current. And the current regulated instantaneous voltage control scheme is used in back-up power mode. The system model and control algorithm are described and analyzed, and the system performance is verified by the simulation results.

  • PDF

MRAC 기법과 좌표변환을 이용한 PWM 인버터 구동 PMSM의 데드타임 보상기법 (Dead Time Compensation Scheme for a PWM Inverter-fed PMSM Drive Using MRAC Scheme and Coordinate Transformation)

  • 김경화
    • 조명전기설비학회논문지
    • /
    • 제26권1호
    • /
    • pp.29-37
    • /
    • 2012
  • A simple and effective dead time compensation scheme for a PWM inverter-fed permanent magnet synchronous motor (PMSM) drive using the model reference adaptive control (MRAC) and coordinate transformation is presented. The basic concept is to first transform a time-varying disturbance caused by the dead time and inverter nonlinearity into unknown constant or slowly-varying one by the coordinate transformation, and then use the MRAC design technique to estimate this parameter in the stationary reference frame. Since the MRAC scheme is a suitable way of estimating such a parameter, the control performance can be significantly improved as compared with the conventional observer-based method tracking time-varying parameters. In the proposed scheme, the disturbance voltage caused by the dead time is effectively estimated and compensated by on-line basis without any additional circuits nor existing disadvantages as in the conventional methods. The asymptotic stability is proved and the effectiveness of the proposed scheme is verified.