• Title/Summary/Keyword: Reduction ratio of compressive strength

Search Result 209, Processing Time 0.026 seconds

Properties of shrinkage reducing agent and mortar used Anhydrite and C12A7-based slag (무수석고와 C12A7계 슬래그를 사용한 수축저감제 및 모르타르 특성)

  • Park, Soo-Hyun;Chu, Yong-Sik;Seo, Sung-Kwan;Park, Jae-Wan
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.2
    • /
    • pp.101-106
    • /
    • 2013
  • In this study, shrinkage reducing agent was fabricated with $12CaO{\cdot}7Al_2O_3(C_{12}A_7)$ of CA-based slag and anhydrite. Mortars added shrinkage reducing agent were experimented for enhancement of shrinkage reduction and compressive strength. The properties of setting time, length change and compressive strength of mortar changed with mixing ratios. From 0% to 6% $C_{12}A_7$-based slag, setting times got shorter and length changes of mortars were similar to 7days. From 1day to 7days, the more mortar had $C_{12}A_7$-based slag, the higher compressive strength. At 28days, compressive strength of mortars with 6% $C_{12}A_7$-based slag was about 36MPa. After 35days, mortar with 6% $C_{12}A_7$-based slag had the lowest ratio of shrinkage reduction. So mortar with 6% $C_{12}A_7$-based slag had the excellent characteristics such as compressive strength and shrinkage reduction ratio.

Engineering Properties of Permeable Polymer Concrete for Pavement Using Polypropylene Fiber (폴리프로필렌섬유를 혼입한 포장용 투수성 폴리머 콘크리트의 공학적 성질)

  • Sung, Chan-Yong;Lee, Seung-Hoon
    • Korean Journal of Agricultural Science
    • /
    • v.37 no.2
    • /
    • pp.277-283
    • /
    • 2010
  • Research on permeable pavement like asphalt and concrete pavement with porous structure has been increasing due to environmental and functional need such as reduction of run off and flood. This study was performed to evaluate void ratio, permeability coefficient, and compressive strength of permeable polymer concrete (PPC) using crushed and recycled coarse aggregate that is obtained from waste concrete. Also, 6 mm length of polypropylene fiber was used to increase toughness and interlocking between aggregate and aggregate surrounded by binder. Binder and filler used were unsaturated polyester resin and CaCO3, respectively. The mix proportions were determined to satisfy the requirement for the workability and slump according to aggregate sizes 5~10 mm. In the test results, regardless of kinds of aggregates and fiber contents, the void ratio, permeability coefficient and compressive strength of all types of PPC showed the higher than the criterion of porous concrete that is used in permeable pavement in Korea. Also, strengths of PPC with increase polypropylene fiber volume fraction showed slightly increased tendency due to increase binder with increase of fiber volume fraction. Accordingly, polypropylene fiber and recycled coarse aggregate can be used for permeable pavement.

Properties of Bleeding Reduction of Concrete Using AE Water Reducing Agent for Reduction of Bleeding (블리딩저감용 AE감수제를 사용한 콘크리트의 블리딩 저감 특성)

  • Kim, Ki-Hoon;Hwang, Yin-Seong;La, Woon;Im, Ju Hyeuk;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.11a
    • /
    • pp.69-72
    • /
    • 2003
  • This study is intended to investigate the fundamental properties of concrete which AE water reducing agent for reduction of bleeding is used, and the properties of bleeding reduction. According to the results, when the adding ratio of AE water reducing agent for reduction of bleeding increases, a range of normal fluidity and aimed air content arc satisfied, setting time is faster than that of normal AE water reducing agent. And bleeding amount decreases, bleeding speed is highest between 60 and 90 min, and sinking depth increases drastically in 60 min. When, AE water reducing agent for reduction of bleeding is added, compressive strength shows a slight variation by air content, but there is not a large influence by addition of AE water reducing agent for reduction of bleeding. Synthetically, it proves that AE water reducing agent for reduction of bleeding satisfies aimed air content in the range of normal slump and can reduce only bleeding without quality variation of compressive strength.

  • PDF

Properties of Bleeding Reduction of Concrete Using AE Water Reducing Agent for Reduction of Bleeding (블리딩저감용 AE감수제를 사용한 콘크리트의 블리딩 저감 특성)

  • Kim, Ki-Hoon;Hwang, Yin-Seong;La, Woon;Im, Ju-Hyeuk;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.69-72
    • /
    • 2003
  • This study is intended to investigate the fundamental properties of concrete which AE water reducing agent for reduction of bleeding is used, and the properties of bleeding reduction. According to the results, when the adding ratio of AE water reducing agent for reduction of bleeding increases, a range of normal fluidity and aimed air content are satisfied, setting time is faster than that of normal AE water reducing agent. And bleeding amount decreases, bleeding speed is highest between 60 and 90 min, and sinking depth increases drastically in 60 min. When. AE water reducing agent for reduction of bleeding is added, compressive strength shows a slight variation by air content, but there is not a large influence by addition of AE water reducing agent for reduction of bleeding. Synthetically, it proves that AE water reducing agent for reduction of bleeding satisfies aimed air content in the range of normal slump and can reduce only bleeding without quality variation of compressive strength.

  • PDF

Engineering Properties of Bleeding Reduction of Concrete Using AE Water Reducing Agent for the Type of Bleeding Reduction (블리딩저감형 AE감수제를 사용한 콘크리트의 공학적 특성)

  • Han, Cheon-Goo;Hwang, Yin-Seong;Lee, Seung-Hoon;Kim, Gyu-Dong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.1
    • /
    • pp.133-140
    • /
    • 2004
  • This study is intended to investigate the properties of bleeding reduction of concrete using AE water reducing agent for the type of bleeding reduction with the replacement admixture. According to the results, when the adding ratio of AE water reducing agent for the type of bleeding reduction increases, a range of normal fluidity and aimed air content are satisfied, setting time is faster than that of normal AE water reducing agent. And bleeding amount decreases, bleeding speed is highest between 60 and 90 min, and sinking depth increases drastically in 50 min. When AE oater reducing agent for the type of bleeding reduction is added, compressive strength shows a slight variation by air content, but there is not a large influence by addition of AE water reducing agent for the type of bleeding reduction. Synthetically, it proves that AE water reducing agent for the type of bleeding reduction satisfies aimed air content in the range of normal slump and can reduce only bleeding without quality variation of compressive strength.

Axial compressive behavior of partially encased recycled aggregate concrete stub columns after exposure to high temperatures

  • Jiongfeng Liang;Wanjie Zou;Liuhaoxiang Wang;Wei Li
    • Steel and Composite Structures
    • /
    • v.52 no.2
    • /
    • pp.121-134
    • /
    • 2024
  • To investigate the compressive behavior of partially encased recycled aggregate concrete (PERAC) stub columns after exposed to elevated temperatures, 22 specimens were tested. The maximum temperature suffered, the replacement ratio of recycled coarse aggregate (RCA), the endurance time and the spacing between links were considered as the main parameters. It was found that the failure mode of post-heated PERAC columns generally matched that of traditional partially encased composite (PEC) columns, but the flange of specimens appeared premature buckling after undergoing the temperature of 400℃ and above. Additionally, the ultimate strength and ductility of the specimens deteriorated with the elevated temperatures and extended heating time. When 400℃< T ≤ 600℃, the strength reduction range is the largest, about 11% ~ 17%. The higher the replacement ratio of RCA, the lower the ultimate strength of specimens. At the temperature of 600℃, the ultimate strength of specimens with the RCA replacement ratio of 50% and 100% is 0.94 and 0.91 times than that of specimens without RCA, respectively. But the specimen with 50% replacement ratio of RCA showed the best ductility performance. And the bearing capacity and ductility of PERAC stub columns were changed for the better due to the application of links. When the RCA replacement ratio is 100%, the ultimate strength of specimens with the link spacing of 100 mm and 50 mm increased 14% and 25% than that of the specimen without links, respectively. Based on the results above, a formula for calculating the ultimate strength of PERAC stub columns after exposure to high temperatures was proposed.

Axial load-strain relationships of partially encased composite columns with H-shaped steel sections

  • Bangprasit, Papan;Anuntasena, Worakarn;Lenwari, Akhrawat
    • Steel and Composite Structures
    • /
    • v.45 no.1
    • /
    • pp.51-66
    • /
    • 2022
  • This paper presents the axial compression behavior of partially encased composite (PEC) columns using H-shaped structural steel. In the experimental program, a total of eight PEC columns with H-shaped steel sections of different flange and web slenderness ratios were tested to investigate the interactive mechanism between steel and concrete. The test results showed that the PEC columns could sustain the load well beyond the peak load provided that the flange slenderness ratio was not greater than five. In addition, the previous analytical model was extended to predict the axial load-strain relationships of the PEC columns with H-shaped steel sections. A good agreement between the predicted load-strain relationships and test data was observed. Using the analytical model, the effects of compressive strength of concrete (21 to 69 MPa), yield strength of steel (245 to 525 MPa), slenderness ratio of flange (4 to 10), and slenderness ratio of web (10 to 25) on the interactive mechanism (Kh = confinement factor for highly confined concrete and Kw = reduction factor for steel web) and ductility index (DI = ratio between strain at peak load and strain at proportional load) were assessed. The numerical results showed that the slenderness of steel flange and yield strength of steel significantly influenced the compression behavior of the PEC columns.

An Experimental Study on the Properties of High Volume Reclaimed Coal Ash Concrete (매립석탄회 고배합 콘크리트의 특성)

  • 한상묵;이종림;하재담;김태홍
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.7-10
    • /
    • 2003
  • The amount of coal ash has been increasing and development of effective use is urgently needed. Various by-products and waste are expected to be used as resources from the point of reduction in environmental load. This is an experimental study to compare the properties of high volume coal ash concrete using the reclaimed coal ash. For this purpose, the mix proportion of concrete according to the content ratio of below 5mm reclaimed coal ash (0.65, 0.70, 0.75 and 0.80). And then air content, slump, compressive strength test were performed. According to test results, it was found that the compressive strength of reclaimed coal ash concrete was similar to the content ratio of below 5mm reclaimed coal ash. And the slump of reclaimed coal ash concrete decreased as the content ratio of below 5mm.

  • PDF

Analysis of actively-confined concrete columns using prestressed steel tubes

  • Nematzadeh, Mahdi;Haghinejad, Akbar
    • Computers and Concrete
    • /
    • v.19 no.5
    • /
    • pp.477-488
    • /
    • 2017
  • In this paper, an innovative technique for finite element (FE) modeling of steel tube-confined concrete (STCC) columns with active confinement under axial compressive loading is presented. In this method, a new constitutive model for the stress-strain relationship of actively-confined concrete is proposed. In total, 14 series of experimental STCC stub columns having active confinement were modeled using the ABAQUS software. The results obtained from the 3D model including the compressive strength at the initial peak point and failure point, as well as the axial and lateral stress-strain curves were compared with the experimental results to verify the accuracy of the 3D model. It was found that there existed a good agreement between them. A parametric study was conducted to investigate the effect of the concrete compressive strength, steel tube wall thickness, and pre-stressing level on the behavior of STCC columns with active confinement. The results indicated that increasing the concrete core's compressive strength leads to an increase in the compressive strength of the active composite column as well as its earlier failure. Furthermore, a reduction in the tube external diameter-to-wall thickness ratio affects the axial stress-strain curve and the confining pressure, while increasing the pre-stressing level has a negligible effect on the two.

The Effect on the Properties of Concrete by Fine Aggregate Fineness Modulus and Grain Shape of Coarse Aggregate (잔골재 조립율 및 굵은골재 입형이 콘크리트의 특성에 미치는 영향)

  • 정용욱;윤용호;이승한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.102-105
    • /
    • 2003
  • The purpose of this study is to examine the influence of the flowability and the compressive strength of concrete after the improving of grain shape of the coarse aggregate and fine aggregate fineness modulus. According to the experimental results, the coarse aggregate after improvement of grain shape it lead to be down by 6% fine aggregate ratio, from 47% to 41%. The 0.5% increase of fine aggregate fineness modulus lead to 3% increase of concrete slump, and 1% reduction of concrete air content. While compressive strength on fine aggregate fineness modulus, it was increased until fineness modulus 3.0, but after it reached by 3.5 it was decreased. The compressive strength of the coarse aggregate after improving the grain shape was decreased by 6% due to loss of the adhesion of cement paste.

  • PDF