• Title/Summary/Keyword: Reduction of vibration level

Search Result 414, Processing Time 0.034 seconds

A study on the Vibration Reduction of the Commercial High-speed Train (운영 중인 고속열차의 진동저감에 관한 연구)

  • Jeon, Chang-Sung;Choi, Sunghoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.697-704
    • /
    • 2017
  • This study was carried out to investigate and alleviate the vibration problem of commercial high-speed trains. First, the measurement of the carbody vibration was performed, in order to determine the vibration level of the high-speed train. The measurement result showed that the vibration level of the driver cab was higher than that of the passenger car and that the vibration became bigger toward the trailing end of the train. The vertical vibration of the driver cab and passenger car was larger than the transverse vibration, and the maximum value of the vibration in the ballast section was larger than that in the concrete section. A dynamic analysis was carried out to improve the vibration of the KTX-Sancheon train. The results of the analysis showed that it is necessary to reduce the vibration of the driver cab and both ends of the passenger cars. To reduce the vibration of the driver cab, it was recommended that the stiffness of the secondary coil spring be reduced and the damping coefficient of the secondary vertical damper be increased. It was found that the failure of the suspension system could be the origin of the vibration problem of the high-speed train. The proper management of wheel wear plays an important role in the improvement of the operation efficiency and reduction of the carbody vibration of high-speed trains, and research is underway to change the present wheel profile to increase the mileage between wheel turning.

BOOMING INDEX DEVELOPMENT IN A PASSENGER CAR (승용차 부우밍 인덱스 개발에 관한 연구)

  • Chae, Hee-Chang;Lee, Sang-Kwon;Park, Dong-Chul;Jung, Seung-Gyoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.332.2-332
    • /
    • 2002
  • Booming sound is one of the most important interior sound of a passenger car. The conventional booming noise research was focused on the reduction of the A-weighted sound pressure level. However A-weighted sound pressure level can not give the whole story about the booming sound of a passenger car. In this paper, we employed sound metric which is the subjective parameter used in psychoacoustics. (omitted)

  • PDF

The Prediction of Vibration Reduction due to Vibration Isolating Countermeasure at Railway Station (역사의 방진대책에 따른 진동 저감 예측)

  • Lee, Tae-Keun;Park, Won-Gi;Kim, Byoung-Sam
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.1
    • /
    • pp.11-16
    • /
    • 2011
  • When the trains are passed the station, a serious force is applied to ground and the caused vibration is propagated to the area of the station by the ground and rocks. The caused vibration brings about the operation interruption of the equipment which is sensitive to the vibration, or will bring about the structural damage of the station. In this study, to investigate the vibrational evaluation of railway station by the train service, the vibration simulation was performed and analyzed the effect of the vibration isolating countermeasure. From the vibration measurement, all trains that passed through the station exceeded the vibration criteria. Therefore, the vibration isolating countermeasure was established and the vibration simulation was performed.

보일러 급수 펌프의 과도진동 연구 사례 - 실험 및 신호처리를 중심으로 -

  • Kim, Jeung T.;Lim, Byung-Duk;Lee, Hyun
    • Journal of KSNVE
    • /
    • v.1 no.2
    • /
    • pp.129-140
    • /
    • 1991
  • The boiler feed pump located at a power plant has been experienced a severe vibration since the plant began to service in early 1980. The research is focused on the field measurement and implementation of simple signal processing techniques in order to provide realistic and effective solution which could be implemented into the plant. Based on the root cause analysis for the trouble-making pump system, the driving part gear in the fluid coupling system is identified as a potential source. The followed verification test confirms the analytical result. The test result shows that vibration reduction obtained after the gear replacement reaches up 15.8 dB, which is 1/6 times of the vibration level compared to that of the troble-making pump. The measured vibration level of the pump satisfies the manufacture criteria and guarantees the smoothed operation.

  • PDF

Study of Muffler for Rotary Compressor by Taguchi Method Viewpoint (회전형 압축기용 머플러의 연구(1) : 다꾸찌 기법 관점에서)

  • 박성근
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.548-553
    • /
    • 1998
  • The specific noise level of 18 rotary compressor mufflers were measured and these data were analyzed by the Taguchi robust design method and the neural network. The optimal design value obtained by the neural network generally showed good agreement with that by the Taguchi method. The effects of eight important design variables on the specific noise level were discussed.

  • PDF

Optimization of Automotive Engine-cooling Fan Noise Using Response Surface Method (반응면 기법을 이용한 자동차 엔진 냉각팬의 저소음설계)

  • Lee, J.;Ahn, J.;Lee, S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.407-412
    • /
    • 2000
  • Response surface method is employed in optimizing the acoustic performance of automotive engine-cooling axial fans. The effects of modifications in blade geometry on noise reduction are investigated. Taking the far-field noise level as the objective, a quadratic response surface is constructed utilizing D-Optimality condition as the candidate-points selection criteria. It is shown that the quadratic model exhibits an excellent fitting capability resulting in the blade design with low far-field noise level.

  • PDF

Appropriateness Evaluation of Train Vibration Evaluation Method Considering Vibration Levels of Retaining Wall Adjacent to Railway Tunnels (철도터널과 인접한 흙막이 가시설의 진동 수준을 고려한 열차진동 평가방법의 적정성 평가)

  • Donghee Woo;Yeongjin Lee;Yongjae Song;Kangil Lee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.10
    • /
    • pp.5-13
    • /
    • 2023
  • With the recent increase in development projects centered on urban areas, the construction of building structures is increasing in areas adjacent to the urban railway operation section. In this case, since ground vibration is generated by the train in operation and affects the adjacent structure, the building structure needs appropriate vibration reduction against train vibration generated at the adjacent location from the desing phase. However, the vibration levels calculated vary depending on the train vibration evaluation method, which means that the implementation of vibration reduction may vary depending on the train vibration evaluation method. Therefore, this study calculated the vibration level according to ground conditions, tunnel depth and separation distance between vibration sources and adjacent structures using numerical analysis and train vibration evaluation methods, and compared them to designning phase. And the appropriate separation distance between the tunnel and the adjacent structure was evaluated by comparing the vibration level with the allowable standards. As a result of the study, the Ungar and Bender evaluation method is evaluated as the most appropriate among the train vibration evaluation methods, and the appropriate separation distance between the tunnel and the adjacent structure is evaluated to be more than 4.5D.

A Study on Rail Vibration and Its Reduction Plan in Central Daejeon Area (대전 도심지역의 철도진동의 영향과 대책)

  • Ryu, Myoung-Ik;Suh, Man-Cheol;Lee, Won-Kook
    • Journal of the Korean Geophysical Society
    • /
    • v.3 no.4
    • /
    • pp.269-280
    • /
    • 2000
  • Rail vibration in city zone is becoming a serious environmental problem. In order to make a reduction plan for rail vibration, the research was conducted in which many experiments to measure actual rail vibration along the railroad through the central Deajeon area. A digital vibration level meter was used to measure rail vibration. Vibration levels of Z-axis were measured at every second for the duration of the train passing. The measuring station was placed at every 5m for the distance of 55m. A total of 353 different sets of vibration level were obtained. The signals were processed to get $L_{10}$ value and analyzed in terms of distance, train velocity, and number of trains. As a result, it has been found that rail vibration exceed the allowable vibraton limit of 60 dB, at the point of 25 m far from the railroad center, which is regulated by the las of vibration and noise. Train velocity was found to affect a little for vibration level within the zone. It was also found that a trench installed along a railroad could reduce vibration level up to approximately 10 percent. A model test was conducted to investigate the influence of the location and size of trench, on the transfer of vibration. A heavy steel ball was used to generate vibrations. On the basis obtained from this study, it could be concluded that the application of distance-attenuation and the installment of a trench along railroad could be applied as a reduction plan for rail vibration. Because limitions might exist to depend on the effect of distance attenuation, trenchs excavated along a railroad might be suggested as the most efficient solution to reduce railroad vibration.

  • PDF

Noise and Vibration Solutions Considering Stability Effects for High-Speed Rail ChonAn Station in Korea (한국고속철도 천안역사에 대한 소음 및 진동영향 연구)

  • Kweon Young-Cheol
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.848-853
    • /
    • 2005
  • The objective of this paper is to address to the providing an adequate noise and vibration solution, required for High Speed Rail while maintaining the stability criteria of the ChonAn station structure, the first constructed in Korean High Speed Railway. The significant acoustic pressure level will be induced by the high speed trains passing-by. Therefore, the high level study of this case is necessary. The acoustic pressure level of 85 dB(A) inside the ChonAn station is expected, and the spaces below concrete slab are not suitable for commercial purpose, thus installation of filtering systems (spring boxes containing viscous dampers, ballast mats and acoustic shield) are provided to reduce the effect of the noise and vibration to acceptable level of 55 dB(A). But, a major drawback of application of the previously conducted experimental results was that the actual effect of installation of filtering system was never been validated. Therefore, the acquisition of noise and vibration on the present structure were obtained and compared to the computer simulations. These predicted the behavior of the station reasonably well. Also, the installation of filtering systems gave the superior reduction on noise and vibration. This application is successfully adapted without scarifying stability criteria related to the structural stability including excessive deformations or displacements. Three traffic operation safety limits: deck vertical acceleration, deflection of the structure, and longitudinal displacement of the slab were satisfactory.

  • PDF

Vibratory Loads Reduction of a Rotor in Slow Descent using Higher Harmonic Control Technology (고조파제어(HHC) 기법을 이용한 저속 하강 비행중인 로터의 진동하중 억제에 관한 연구)

  • You, Younghyun;Jung, Sung Nam
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.6
    • /
    • pp.440-447
    • /
    • 2013
  • In this paper, a higher harmonic control (HHC) methodology is applied to find the optimum input scenario for the vibratory hub loads reduction. A comprehensive aeroelastic analysis code, CAMRAD II, is used to model the HART (Higher-harmonic-control Aeroacoustic Rotor Test) II rotor, and parametric study is conducted for the best HHC inputs leading to a minimum vibration (MV) condition. The resulting outcomes are compared with the earlier HART II test results. It is indicated that the control input adopted in the MV condition showed less satisfactory results. The new MV condition obtained in the present investigation can achieve 45% lower vibration level than the baseline uncontrolled condition. The optimum HHC input results lead to 3/rev harmonic input having $0.8^{\circ}$ amplitude and $350^{\circ}$ phase angle. About 5% reduction in the required power is possible but accompanies with the increase of vibration level.