보일러 급수 펌프의 과도진동 연구 사례 - 실험 및 신호처리를 중심으로 -

  • 김정태 (한국 표준과학 연구원 음향진동연구실) ;
  • 임병덕 (한국 표준과학 연구원 음향진동연구실) ;
  • 이현 (한국전력공사 기술연구원)
  • Published : 1991.12.01

Abstract

The boiler feed pump located at a power plant has been experienced a severe vibration since the plant began to service in early 1980. The research is focused on the field measurement and implementation of simple signal processing techniques in order to provide realistic and effective solution which could be implemented into the plant. Based on the root cause analysis for the trouble-making pump system, the driving part gear in the fluid coupling system is identified as a potential source. The followed verification test confirms the analytical result. The test result shows that vibration reduction obtained after the gear replacement reaches up 15.8 dB, which is 1/6 times of the vibration level compared to that of the troble-making pump. The measured vibration level of the pump satisfies the manufacture criteria and guarantees the smoothed operation.