A Study on the Noise and Vibration Reduction of an Industrial Robot (산업용 로봇의 소음ㆍ진동 저감 연구)

  • 이광열;정두한;임흥순;김영환;정진태
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.11
    • /
    • pp.838-844
    • /
    • 2003
  • The noise and vibration reduction schemes of an industrial robot are studied. Experimental procedures are employed to examine the sources of robot noise. A parametric study is undertaken to observe the effects of each part such as gear, shaft and housing on the sound pressure level. After the part which mainly effects on the noise is proved, we propose countermeasures for reducing the noise and vibration of the robot system.

Development on a Vibration Reducing Element for the Large Transformers (대형 변압기 방진장치개발)

  • Lee, Jun-Shin;Lee, Wook-Ryun;Son, Seok-Man;Lee, Sang-Guk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.259-262
    • /
    • 2005
  • The large transformers used in the electric power company become targets of public complaints because of those characteristics generating high-level noise. Reducing vibration level is the basis of noise control for the large transformers. For this reason, a vibrating reducing element is developed for the large transformers with a sub-element enduring seismic movement. Large attenuation of vibration is achieved by applying the element to the large transformers in a substation.

  • PDF

Assessment of Can Factory working noise and its reduction (산업현장의 소음.진동 원인분석 및 저감방안 연구)

  • Chun, Hyung-Jun;Ko, Sun-Hee;Chang, Seo-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.212-216
    • /
    • 2006
  • The purpose of this study is to obtain an effective enclosing method for noise reduction of press machine operating in a manufacturing company located in Korea. Noise level of the machine is about $90{\sim}105dB$ which is higher than legal standards by industrial safety and health law. This study has predicted the level of noise reduction according to a step by step prevention plan by considering the characteristics of the cause of noise, the permitted limit of noise levels, problems and economical efficiency attendant upon the noise prevention measures. The predicted level of noise at the plant in accordance with the first step is $71.5{\sim}89.5dB(A)$, and can satisfy the permitted limit of noise in a time period of the day. Based on these results, enclosing method adequate for the selected plant's noise characteristics were suggested.

  • PDF

A Study on Reduction of Sound Noise Induced by Disk Rotation in Optical Disk Drives (광 디스크 드라이브의 공력소음 감소에 관한 연구)

  • 송인상;박건순;최학현;김수경;이승엽
    • Journal of KSNVE
    • /
    • v.9 no.4
    • /
    • pp.693-702
    • /
    • 1999
  • We study the characteristics of airflow and sound noise induced by disk rotation in optical disk drives. The characteristics of airflow around a rotating disk surrounded by various tray structures are numerically investigated using a commercial CFD program and then compared with experimental results. Sound pressure and intensity caused by the fluid-structure interactions in the CD/DVD-ROM drive are measured, and the effect of the ariflow on the sound noise and disk vibration is discussed. In order to reduce airflow-induced noise and vibration around the rotating disk, tray geometry is modified. Both numerical and experimental studies implemented with different tray models show that the improved tray model alters the characteristics of the disk-induced airflow, causing the reduction of the airflow-induced sound level.

  • PDF

Noise Reduction of Range Hood in Kitchen Ventilation System (주방 환기 시스템에서 렌지 후드의 소음 감소 방안)

  • 최영석;김철호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.848-851
    • /
    • 2004
  • This paper studied a method for minimizing the noise level emitted from range hoods. Range hoods were used for discharging various hazardous materials generated during household cooking to the outdoors, thus preventing them from being diffused through rooms in the house since they are the main cause of air pollution within dwellings. This study assumed that static pressure was not applied at the discharge outlet of the range hood. As such, the range hood was installed on the wall without the use of a connecting duct or other connectors attached to its discharge outlet. The vibration having the greatest influence on the noise level was determined by measuring the vibration at the front side of the hood where the acoustic omission was at its maximum. A method was then proposed to reduce the noise by simply suppressing the vibration at the vibrating part.

  • PDF

A Study of Noise Reduction in Hard Disk Drive (하드디스크 드라이브에서의 소음 저감에 관한 연구)

  • 곽주영;손진승;이행수;홍민표;고정석;조은형;좌성훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.579-585
    • /
    • 2001
  • This paper proposed a method of reducing a noise in hard disk drive. This method is performed through three parts of procedures. First procedure is sound-oriented experiment, which contains sound intensity techniques and measurements of sound pressure level and sound power. Second is vibration-oriented experiment, which contains FRF(Frequency Response Function) analysis and disk vibration reduction techniques. And the third is computer-oriented simulation, which contains modal analysis and force vibration analysis using ANSYS and sound radiation prediction using SYSNOISE. As these three parts can affect with each other, they should be considered and conducted simultaneously. Through this procedure sound power is measured 2.7 Bels in idle-spinning mode, which is the lowest noise level in the HDD industries.

  • PDF

A Study on the Vibration Reduction Characteristics of the Elastic Rail Fastener/Ballast Mat (방진체결구/방진매트의 진동저감특성에 관한 연구)

  • 엄기영;황선근;고태훈;김정근
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.375-380
    • /
    • 2001
  • Generally, countermeasures for the train-induced vibration are divided into the measures at the source, propagation path and receiving object. Among these measures the countermeasure at the source location is the most active and effective one in the field of railroad. In this study, the effectiveness of each anti-vibration measures at the track(source location) such as elastic rail fastener, ballast mat were evaluated through the comparison of acceleration level, insertion loss at the installed locations of each measures. As result of field measurement of vibration at the railroad track supporting structures and on the ground nearby the structures, elastic rail fastener showed vibration reduction effect of 4.5 ∼7.3㏈ on the concrete slab, 1.6∼3.7㏈ on the ground with the train operation speed of 80km/hr. In the case of ballast mat, the vibration reduction effect at the concrete slab and on the ground were 11.9∼13.3㏈ and 6.1∼7.6㏈, respectively.

  • PDF

Floor Impact Noise Reduction Performance of Double-Floor System in Apartments (공동주택 이중바닥구조의 바닥충격음 저감성능)

  • Baek, Gil-Ok;Park, Hong-Gun;Mun, Dae-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.197-202
    • /
    • 2014
  • Floor Impact Noise is a structure-borne noise which is mainly caused by vibration of concrete slabs. The majority of previous studies have focused on investigating performance of absorbing sheets on the reduction of floor impact noise. But absorbing sheets do not efficiently reduce heavy-weight floor impact noise level because it cannot absorb slab vibration, which is the fundamental noise source. In this study, double-floor system was developed in order to reduce floor impact noise level in residual buildings. This floor system reduces heavy-weight impact noise level by reducing vibration response at the center of slab, which has maximum amplitude in the 1st vibration mode. In order to identify the performance of the double-floor system, experiments were planned. Primary test parameters are span of double floor, arrangement and types of absorbing sheets.

  • PDF

A Study on the Effect of Low Noise Wheel for the Noise and Vibration Reduction (방음차륜의 소음진동 저감효과에 관한 연구)

  • 김재철;유원희;문경호
    • Journal of KSNVE
    • /
    • v.10 no.4
    • /
    • pp.629-635
    • /
    • 2000
  • Wheel /rail interaction has been known as a major source of railway noise. In this paper, a low noise wheel structure is developed and its effect on noise reduction is investigated. The developed low noise wheel employees a rubber material inserted into a steel rim or mounted on the wheel surface. Since the low noise wheel has low stiffness and high damping ratio compared to a solid wheel, the measurement results show that it reduces the rolling and squeal noise. It turns out that the proposed wheel could reduce interior noise level by 4∼5dB(A) and vehicle vibration level by 7∼10 dB. Although the proposed structure seems to be promising in noise reduction of railway vehicles, the low noise wheel is to be verified in endurance and cost effect.

  • PDF

A Study on the Characteristics of Transferring Vibration and Effect of Nearby-Building Induced by the High-speed Train in Operation (고속철도 운행에 의한 진동전달특성 및 인접건물에 미치는 영향에 관한 연구)

  • 배동명;신창혁;최철은;박상곤;백용진
    • Journal of KSNVE
    • /
    • v.11 no.2
    • /
    • pp.354-364
    • /
    • 2001
  • The vibration induced by high speed train running on rail is dealt with as an environmental problem. The train induced vibration is characterized by moving loads at specific frequencies and soil conditions. In fact, it is predicted that the vibration sources are involved the wheel distance, number of cars, speed of operation, drift of rails, structural born vibration, etc. In this paper the characteristics of transferring vibration induced by the high-speed train in operation is discussed. Field measurements was conducted at region from Chungnam Yungj So-jung-myan to Chungbuk Chungwon hyun-do-myun. In the near future. these data will be used as the fundamental data for establishment of the countermeasure for vibrational reduction of high speed train using the results of the field measurements and quantitative prediction of the vibration level