• Title/Summary/Keyword: Reduction of vibration and noise

Search Result 1,554, Processing Time 0.054 seconds

Study on Reduction of Excessive Noise and Vibration of Aft Part of High Speed Ro-Ro Passenger Ship (고속 여객선 선미부 과대 진동/소음 감소를 위한 연구)

  • Shin, Yunkil
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.196-202
    • /
    • 2019
  • In this study, the excessive noise and vibration phenomena of a high-speed Ro/Ro passenger ship were analyzed, and a countermeasure was taken based on them. This ship was granted a comfort class notation by the classification society, which was COMFORT-VIBRATION-II and COMFORT-NOISE-CREW-II. However, unfortunately, excessive noise and vibration in the aft part of the ship were delivered from the twin shaft propellers, and therefore the Class Requirement was not satisfied before delivery. In order to obtain the class notation, all of the concerned parties came to an agreement to reduce the noise and vibration level during operation after delivery because a seasonal ferry service was already scheduled and the cabin was fully booked. The root cause of the massive amount of noise and vibration was mainly the propeller-induced excitation pulse and beating that occurred from the mismatch of the rotating speeds of the two shaft lines. A 1st order vibrating force and beating phenomena existed in the propeller. Thus, a reduction of the excitation force, elimination of the beating phenomena, and decrease of the noise level at the aft area cabins and public spaces were required. In addition, structural reinforcements were conducted using pillars and additional girders at the aft part of the decks.

Vibration and Noise Reduction of Pump And Pipe System (대형펌프와 조합된 배관계에서 발생하는 이상 진동 및 소음 저감에 관한 연구)

  • 배춘희;원종범;조철환;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.473-477
    • /
    • 2001
  • In this paper, Firstly, it is shown that the high vibration and noise source of piping and pump system is the acoustic resonance. Secondly, in order to decrease the high vibration and noise of piping and pump system, the acoustic mode of piping have been changed and its effectiveness is investigated as applied it at piping system practically.

  • PDF

Vibration and Noise Reduction of Pump And Pipe System (대형급수펌프 토출배관계에 발생하는 규칙적인 이상진동 및 소음 특성 규명)

  • 배춘희;조철환;양경현;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.1065-1069
    • /
    • 2003
  • In this paper, Firstly, it is shown that the high vibration and noise source of piping and pump system is the acostic resonance. Secondly, in order to decrese the high vibration and noise of piping and pump system, the acostic mode of piping have been changed and its effectiveness is investigated as applied it at piping system practically.

  • PDF

Experimental Study of Vibration and Noise Reduction Effect of Railroad Vibration Isolator (철도레일 방진 체결장치의 진동 및 소음 저감 효과에 관한 실험적 연구)

  • Lee, Jang-Hyun;Kim, Tae-Eon;Lee, Seong-Choon;Chon, Ik-Pom
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1373-1378
    • /
    • 2000
  • Vibration caused by railroad vehicle including subway train running raises a lot of problems to the neighboring buildings. Therefore lots of methods to isolate the railway vibration have been studied and practically applied to sites. As one of them, specially designed vibration isolation device was installed in the some section of Seoul subway. This device is installed between the rail and track slab. Because the process of installation is relatively simple, this method can be applied to the existing railways in servicing. We measured the vibration and noise to check the effectiveness of this device before and after the installation. The result showed that the vibration level of the slab and platform was reduced to 7 - 10 dB. Expecially high frequency component was reduced to a large amount. From this result, we can conclude that these kind of devices are useful to the reduction of the railroad vibration, expecially the high frequency vibration which can cause structure born noise.

  • PDF

A Study on Reduction of Sound Noise Induced by Disk Rotation in Optical Disk Drives (광 디스크 드라이브의 공력소음 감소에 관한 연구)

  • 송인상;박건순;최학현;김수경;이승엽
    • Journal of KSNVE
    • /
    • v.9 no.4
    • /
    • pp.693-702
    • /
    • 1999
  • We study the characteristics of airflow and sound noise induced by disk rotation in optical disk drives. The characteristics of airflow around a rotating disk surrounded by various tray structures are numerically investigated using a commercial CFD program and then compared with experimental results. Sound pressure and intensity caused by the fluid-structure interactions in the CD/DVD-ROM drive are measured, and the effect of the ariflow on the sound noise and disk vibration is discussed. In order to reduce airflow-induced noise and vibration around the rotating disk, tray geometry is modified. Both numerical and experimental studies implemented with different tray models show that the improved tray model alters the characteristics of the disk-induced airflow, causing the reduction of the airflow-induced sound level.

  • PDF

A Study on the Development of a Noise Reduction Device Installed at the Top of Noise Barrier for the 400 km/h Class High-speed Railroad (400 km/h급 고속철도의 소음저감을 위해 방음벽 상부에 설치하는 소음저감장치 개발에 관한 연구)

  • Yoon, Je-Won;Kim, Young-Chan;Jang, Kang-Seok;Hong, Byung-Kook;Eum, Ki-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.9
    • /
    • pp.823-830
    • /
    • 2013
  • The purpose of this study is to develop a noise reduction device installed at the top of noise barrier for further decreasing of noise level of 400 km/h class high-speed railroad. For this, the frequency spectrum of 400 km/h class high-speed railroad was analyzed through the field noise test, and the tuning frequency was determined to design a noise reduction device. The noise reduction device was designed to have noise reduction performance of at least 3 dB(A) using the prediction method(2D BEM) and through the laboratory test with the prototype. Finally, the outdoor test showed that this device could decrease noise level of 400 km/h class high-speed railroad even more than 3 dB(A).

A Study of Noise Reduction in Hard Disk Drive (하드디스크 드라이브에서의 소음 저감에 관한 연구)

  • 곽주영;손진승;이행수;홍민표;고정석;조은형;좌성훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.579-585
    • /
    • 2001
  • This paper proposed a method of reducing a noise in hard disk drive. This method is performed through three parts of procedures. First procedure is sound-oriented experiment, which contains sound intensity techniques and measurements of sound pressure level and sound power. Second is vibration-oriented experiment, which contains FRF(Frequency Response Function) analysis and disk vibration reduction techniques. And the third is computer-oriented simulation, which contains modal analysis and force vibration analysis using ANSYS and sound radiation prediction using SYSNOISE. As these three parts can affect with each other, they should be considered and conducted simultaneously. Through this procedure sound power is measured 2.7 Bels in idle-spinning mode, which is the lowest noise level in the HDD industries.

  • PDF

A Study on the Noise Reduction of the Engine Cooing Fan of an Express Bus by Change of Design Parameters (설계파라미터 변경에 의한 고속버스용 엔진 냉각 팬의 저소음화 연구)

  • Jae-Eung OH;You-Yub LEE;Hyun-Jin Sim;Mon-Kab Joe
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.333.1-333
    • /
    • 2002
  • This paper suggests the noise reduction method of the engine cooling fan. It was estimated the fannoise contribution at the engine room and identified the noise source at the rotating fan by sound intensity method, first. And it has been developed the program for predicting the noise spectrum of axial flow fan. The radiated acoustic pressure is expressed the discrete frequency noise peaks at BPF and its harmonics and the line spectrum at the broad band by the noise generation mechanisms. In this paper it is shown that the comparison of the measuted and calculaed noise spectra of fn for the validation of the noise predictiong program. And this paper presents the characteristics of a fan noise due to modify the design parameters. Accordingly, it was obtained the design parameter values for noise reduction of fan.

  • PDF

The Study about Vibration Reduction of the Electronic Forklift on Experiment at Methods (실험적 방법을 통한 전동식 지게차의 진동저감에 대한 연구)

  • Chung, Jin-Tai;Park, Chul-Jun;Im, Hyung-Bin;Moon, Chang-Ki
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.577-581
    • /
    • 2006
  • In this study, it is presented a vibration cause of an electronic forklift by a variable excitation through experimental methods. It is presented a vibration influence by a variable excitation and established an FE model about structure vibration. It is used an FE model and presented parameters causing the vibration. It is presented a mechanism causing the vibration of the electronic forklift and proposed a vibration reduction of the electronic forklift.

  • PDF

A Case Study on Noise Effect Assessment and Countermeasure by Emergency Generators installed in an Exterior and interior Architecture (건축물 내외부에 설치된 비상용 발전기 소음영향 평가 및 대책방안 사례연구)

  • Yun, Dae-Jin;Choi, Jae-Sung;Kim, Chang-Yeol;Hong, Chang-Wan;Kim, Han-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.88-93
    • /
    • 2012
  • Recently data centers are being established or expanded according to IT industry development. A data center must be to install emergency generator. In case of the data center located the densely populated urban area, the operating noise of an emergency generator can be the cause of complains. In this case, in order to establish an effective and economical measure and quantitative and thorough review is needed by noise & vibration specialists. To achieve this, in this study, it is suggested noise reduction measure using noise measurement data and 3D noise analysis method.

  • PDF