• Title/Summary/Keyword: Reduction of cooling and heating energy

Search Result 108, Processing Time 0.027 seconds

Analysis of Building Energy Reduction Effect based on the Green Wall Planting Foundation Type Using a Simulation Program (건물일체형 패널형 벽면녹화 식재기반 유형별 건물에너지 성능 분석)

  • Kim, Jeong-Ho;Kwon, Ki-Uk;Yoon, Yong-Han
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.6
    • /
    • pp.936-946
    • /
    • 2015
  • This study is aimed to analyze the reduction performance of building energy consumption according to planting base types of panel-type green walls which can be applied to existing buildings. The performance was compared to the general performance of green walls that have demonstrated effects of improving the thermal environment and reducing building energy consumption in urban areas. The number of planting base types was 4 in total, and simulations were conducted to analyze the thermal conductivity, thermal transmittance, and overall building energy consumption rate of each planting base type. The highest thermal conductivity by the planting base type was Case C (0.053W/mK), followed by Case B (0.1W/mK) and Case D (0.17W/mK). According to the results of energy simulation, the most significant reduction of cooling peak load per unit area was Case C (1.19%), followed by Case B (1.14%) and Case D (1.01%) when compared to Case A to which green wall was not applied; and the most significant reduction of heating peak load per unit area was estimated to be Case C (2.38%), followed by Case B (1.82%) and case D (1.50%) when compared to Case A. The amount of yearly cooling and heating energy use per unit area showed 3.04~3.22% of reduction rate. The amount of the 1st energy use showed 5,844 kWh/yr of decrease on average for other types when compared to Case A. The amount of yearly $CO_2$ emission showed 996kg of decrease on average when compared to Case A to which the green wall was not applied. According to the results of energy performance evaluation by planting location, the most efficient energy performance was eastward followed by westward, southward and northward. According to the results of energy performance evaluation by planting location by green wall ratio, it was found that as the ratio of green wall increased, the energy performance displayed better results, showing approx. double reduction rate in energy consumption at 100% of green wall ratio than the reduction rate at 20% to 80% of green wall ratio.

The Development of the Calibration Method of Building Energy Consumption by HDDm and CDDm (냉·난방도일에 따른 건물에너지 사용량 보정기법 개발)

  • Kim, Dongi;Lee, Byeongho
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.6
    • /
    • pp.15-26
    • /
    • 2018
  • It is difficult to check the exact building energy consumption reduction such as when green remodeling of buildings, because it is due to outdoor air temperature over the years. And in Korea although Big Data of building energy consumption is collected and managed through "The Information System of the Building Energy and Greenhouse Gases" it is underutilized because of non calibration of outdoor air temperature change. Therefore, this study aims to develope calibration method of building energy consumption by outdoor air temperature according to micro climates, and building use types. As a result of analysis, Regression equations of Building energy consumption and $HDD_m/CDD_m$ are derived and calibration method is developed by Regression coefficient.

Energy Consumption and Thermal Comfort Assessment of Conventional Forced-air System According to AHU Discharge Air Temperature (AHU 토출온도에 따른 일반 공조시스템의 에너지 소비량 및 실내 온열환경 분석)

  • Kim, Min Ji;Yeon, Sang Hun;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.2
    • /
    • pp.51-57
    • /
    • 2018
  • Recently, global warming has been a serious issue on the worldwide, and the importance of energy conservation is increasing. In most buildings, energy consumption increases due to cooling, heating, and ventilation. Because of these issues, researches have been carried out to reduce building energy. However, in most conventional forced-air system, the guidelines for the Air Handling Unit (AHU) discharge air temperature are not fully established. The purpose of this study is to assess the impact of AHU discharge air temperature, which is one of the important control variables, on the overall energy consumption and thermal comfort characteristics by modeling conventional forced-air system using EnergyPlus. In addition, recommendations for energy reduction in conventional AHU is provided.

Present and Future of Green Hospitals in Korea (종합병원의 친환경적 시설 실태와 향후 과제)

  • Seo, Youngjoon;Kang, Shinhee;Kim, Yeon-Hee;Lee, Yong-Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.16 no.1
    • /
    • pp.43-53
    • /
    • 2010
  • This study purports to investigate the status quo of the environmentally-friendly green healthcare in teaching hospitals through the questionnaire survey. Data were collected from a total of 46 hospitals. The survey results revealed that most teaching hospitals did not meet the global standard of environmentally-friendly green hospitals. Especially, such items as alternative energy system, water recycling, CO2 emission reduction, green building construction, installation of pond or spring were found to be significantly below global standard. Based upon the study results, various strategies for establishing green hospitals were discussed. For example, energy saving design, such as solar heating, natural wind cooling, automatic temperature controller, green material use, wall surrounded by ivy, were recommended. In conclusion, the strategy and evaluation tool developed in the study will provide a good guide for establishing environmentally-friendly green hospitals.

The Influence of Regulatory Focus on Consumer Responses to Smart Home Services for Energy Management

  • Kim, Moon-Yong;Cho, Heayon
    • International journal of advanced smart convergence
    • /
    • v.9 no.3
    • /
    • pp.221-226
    • /
    • 2020
  • Smart homes have become the state of the art in the reduction and monitoring of energy usage within a residential setting. Emerging threats such as climate change, global warming and volatility in energy prices have fuelled the interest in smart systems. Given that environmental sustainability has become a more significant factor for consumers, this research examines whether consumers' attitudes toward smart home services for efficient energy management differ according to their regulatory focus. Specifically, it is predicted that consumers will have more favorable attitudes toward smart home services for efficient energy management when they are promotion-focused (vs. prevention-focused). The results indicate that respondents with a promotion (vs. prevention) focus reported significantly more favorable attitudes toward smart home services for energy management (e.g., smart cooling/heating system, smart ventilation & air conditioning system, smart thermostats, smart plugs, and smart switches). We suggest that regulatory focus may be an effective marketing and segmentation tool in promoting smart home services for energy management and facilitating their receptiveness to the services.

Thermoeconomic Analysis of Hybrid Desiccant Cooling System Driven by District Heating (지역난방에 연계된 하이브리드 제습냉방시스템의 경제성 분석)

  • Ahn, Joon;Kim, Jaeyool;Kang, Byung Ha
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.9
    • /
    • pp.721-729
    • /
    • 2014
  • A hybrid desiccant cooling system (HDCS) that uses a heat pump driven by district heating instead of a sensible rotor can provide an increased energy efficiency in summer. In this paper, the summer operation costs and initial costs of both the HDCS and traditional systems are analyzed using annual equal payments, and national benefits are found from using the HDCS instead of traditional systems. In the analysis results, the HDCS reduces the operation cost by 30 compared to the traditional systems, and each HDCS unit has 0.079 TOE per year of primary energy savings and 0.835 $TCO_2$ per year of $CO_2$ emission reduction more than the traditional systems. If HDCSs were to be installed in 680,000 households by 2020, this would produce a replacement power effect of 463 MW. Despite this savings effect, HDCSs require a government subsidy before they can be supplied because the initial cost is higher than that of traditional systems. Thus, this paper calculates suitable subsidies and suggests a supply method for HDCSs considering the national benefits.

Design and Exergy Analysis for a Combined Cycle using LNG Cold/Hot Energy (액화천연가스 냉온열을 이용한 복합사이클의 설계 및 엑서지 해석)

  • Lee Geun Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.285-296
    • /
    • 2005
  • In order to reduce the compression power and to use the overall energy contained in LNG effectively, a combined cycle is devised and simulated. The combined cycle is composed of two cycles; one is an open cycle of liquid/solid carbon dioxide production cycle utilizing LNG cold energy in $CO_2$ condenser and the other is a closed cycle gas turbine which supplies power to the $CO_2$ cycle, utilizes LNG cold energy for lowering the compressor inlet temperature, and uses the heating value of LNG at the burner. The power consumed for the $CO_2$ cycle is investigated in terms of a production ratio of solid $CO_2$. The present study shows that much reduction in both $CO_2$ compression power (only $35\%$ of power used in conventional dry ice production cycle) and $CO_2$ condenser pressure could be achieved by utilizing LNG cold energy and that high cycle efficiency ($55.3\%$ at maximum power condition) in the gas turbine could be accomplished with the adoption of compressor inlet cooling and regenerator. Exergy analysis shows that irreversibility in the combined cycle increases linearly as a production ratio of solid $CO_2$ increases and most of the irreversibility occurs in the condenser and the heat exchanger for compressor inlet cooling. Hence, incoming LNG cold energy to the above components should be used more effectively.

An Effect of the Change of Orientation and Window Area Ratio upon Building Energy Requirement in Apartment Housings (공동주택 향별 창면적비 변화에 따른 에너지 영향도 분석)

  • Kim, Jae Moon;Lee, Gyu Chul;Lee, Seung Gyu;Kim, Min Sung;Min, Joon Ki
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.21-26
    • /
    • 2013
  • Due to the increasing concerns about the buildings which have affected the global environment, most countries have enacted a regulation for the sustainability of domestic buildings. In 2008, the Korean government started to enact a regulation of apartment and office buildings for energy saving. Many research on the sustainable apartment building focuses on $84m^2$ or larger type in response to market demand; therefore, small size type such as $46m^2$ type needs to be researched. In addition, the research on the orientation and window to wall ratio of the building have been separately studied as a means of energy reduction; therefore, the research on correlation of the orientation and window to wall ratio hasn't been fully explored yet. This paper analyzes the energy demand of the apartment building as the change of orientation and window to wall ratio among $46m^2$ and $84m^2$ type. In conclusion, when reducing the window to wall ratio, energy demand was reduced, except when the orientation of the building was between from +10 to -20 from the south.

A Case Study on the Acclimatization's Housing for Environmental Load Reduction (환경부하 저감을 위한 기후순응주거 사례연구)

  • Cho, Sung-Woo;Oh, Se-Gyu
    • Journal of the Korean housing association
    • /
    • v.24 no.6
    • /
    • pp.69-79
    • /
    • 2013
  • The concept of sustainable development to preserve natural environment through economy in resources and energy is gradually distinguished since environmental problems as a series of air pollution and global warming take place now. Building occupies more than 1/3 of energy consumption in the whole world. Energy consumption of buildings caused a quick increase in the amount of energy use by air conditioning, which has a lot of effects on exhaustion of fossil energy as well as an increase in environmental load. Therefore, this research intends to suggest characteristics and direction for the designing of acclimatization's housing through the case study on acclimatization's housing. Acclimatization's housing is designed to reduce building load from the designing stage unlike green home or low-energy apartment. Also, factors which are commonly applied to acclimatization's housing are applied complexly by design strategic factors of Heating, Cooling and Lighting. The applied design factors make effects mutually and complexly. In addition, design strategy showed different priority by designing direction.

Analysis on the Cooling Effect of Applying Temperature Discoloration Paint to a Roof Surface (온도 변색 도료의 지붕 적용 및 냉방효과 분석)

  • Baek, Sanghoon
    • Land and Housing Review
    • /
    • v.13 no.4
    • /
    • pp.115-123
    • /
    • 2022
  • This study aims to introduce a temperature discoloration roof system and its cooling effect in the summer. Temperature discoloration paints can reverse their colors based on temperature changes. If these paints on the roof surface could color-shift between white in the summer and black in the winter, the indoor cooling and heating loads can be affected by the changes in reflection and absorption of solar radiation. Focusing on the summer period, the study analyzed the cooling effect of applying temperature discoloration paint that color-shifts from white to black on the roof surface of a small experimental building module and compared it to commonly used gray and green roof colors. Results of the experiment showed that the surface temperature of the roof with temperature discoloration paint was lower than the gray and green color roofs by a maximum of 10℃. Furthermore, the indoor temperature of the experimental module with the temperature discoloration roof was lower than the gray and green roofs by approximately 3℃. Findings of the study indicate that the application of temperature discoloration paint to the roof can reduce indoor cooling loads.