• 제목/요약/키워드: Reduction of Harmonic Magnitude

검색결과 22건 처리시간 0.017초

3상 유도전동기 구동을 위한 새로운 RPWM 기법 (Novel RPWM Techniques for Three-Phase Induction Motor Drive)

  • 권수범;김남준
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권4호
    • /
    • pp.262-268
    • /
    • 2004
  • This thesis is proposing novel RPWM (Random PWM) techniques that can locate PWM pulse to do random. RPWM techniques to propose locates SVPWM (Space Vector PWM) pulse by number of each random and principle to locate of pulse applies different random function and locate pulse. For propriety verification of proposed techniques, achieve an simulation and experiment that use MATLAB/SIMULINK about proposed RPWM techniques algorithm and IGBT inverter composition that use DSP(TMS320C31). Specially, analyze harmonic spectra of inverter output current when the induction motor speed is more than 10,000 rpm, confirm that RPWM's effect in high speed degree appears. Proposed RPWM techniques propriety prove from reduction effect of harmonic magnitude that corresponds to an integer times of switching frequency.

고속 3상 유도전동기 구동을 위한 새로운 RPWM 기법 (Novel RPWM Techniques for High-Speed Three-Phase Induction Motor Drive)

  • 권수범;이효상;박종진;김남준
    • 전력전자학회논문지
    • /
    • 제9권4호
    • /
    • pp.364-371
    • /
    • 2004
  • 본 논문에서는 PWM 펄스를 랜덤하게 위치시킬 수 있는 새로운 3상 공간 벡터 RPWM(Random PWM) 기법을 제안한다. 기존의 RPWM 방식과 달리 3상 대칭 변조 기법에 의해 발생된 공간 전압 벡터 PWM(Space Vector PWM) 펄스를 랜덤하게 위치시키는 원리를 각 섹터마다 달리 적용하여 RPWM을 구현하는 기법을 제안한다. 제안 된 기법의 타당성 검증을 위하여, 제안된 RPWM 기법 알고리즘에 대해 MATLAB/SIMULINK를 이용한 시뮬레이션 및 DSP를 이용한 IGBT 인버터를 구성하여 실험을 수행한다. 특히 10,000 rpm 이상의 고속운전 시, 공간 전압 벡터 PWM 기법과 제안된 RPWM 기법에 의해 발생되는 인버터 출력 전류의 고조파 스펙트럼을 비교한다. 즉 전류 고조파 스펙트럼에서 스위칭 주파수 정수배에 해당하는 고조파의 크기를 비교하여 제안된 RPWM의 기법의 타당성을 검증하고자한다.

A Harmonic Circulation Current Reduction Method for Parallel Operation of UPS with a Three-Phase PWM Inverter

  • Kim Kyung-Hwan;Kim Wook-Dong;Hyun Dong-Suk
    • Journal of Power Electronics
    • /
    • 제5권2호
    • /
    • pp.160-165
    • /
    • 2005
  • In a parallel operation of UPS, there are two types of circulating currents between UPS. One is the low order circulating current with a fundamental frequency caused by the amplitude and phase differences of UPS output voltages, and the other is the harmonic circulating current with PWM switching frequency caused by non-synchronized PWM waveforms among UPS. The elimination of the low order circulating current is essential for optimal load sharing in parallel operations of UPS, which can be accomplished by the phase and magnitude control at each UPS. The harmonic circulating current may cause troubles and deteriorate in performance of the controller for optimal load sharing in parallel operation of UPS. This paper presents a PWM synchronizing method to eliminate the harmonic circulation current in parallel operation of UPS. The effectiveness of the proposed scheme has been investigated and verified through experiments by a 50kVA UPS.

단상 변압기 지그재그 결선에 의한 3고조파 전류 저감 효과 분석 (Analysis of Reduction Effect of Three Harmonic Currents by Zigzag Wiring of Single Phase Transformer)

  • 김종겸;김지명
    • 전기학회논문지P
    • /
    • 제66권3호
    • /
    • pp.99-104
    • /
    • 2017
  • The three-phase four-wire power distribution system can be used to supply power to single-phase and three-phase loads at the same time. There are linear loads and nonlinear loads as single-phase loads connected to each phase. The nonlinear load generates a harmonic current during the power energy conversion process. In particular, the single-phase nonlinear load has a higher proportion of generation of the third harmonic current than the harmonics of the other orders. In a three-phase four-wire system, the third harmonic current flows through the neutral wire to the power supply side, affecting the power supply side and the line. Furthermore, the magnitude of the current flowing in the neutral line can be higher than the current flowing in the individual phase. If the neutral current is higher than the phase current, the breaker may be blocked. Therefore, it is necessary to reduce the amount of current flowing in the neutral line by harmonics. There is a method of zigzag connecting a single phase transformer by a method of reducing 3 harmonic current. In this study, the method of reducing the magnitude of the three harmonic currents flowing through the zigzag wire by comparing the polarity and the negative polarity characteristics of the single phase transformer was compared through measurement and simulation.

3상 유도전동기 구동을 위한 새로운 2상 RPWM기법 (Novel Two-Phase RPWM Technique for Three-Phase Induction Motor Drive)

  • 이효상;김남준
    • 전력전자학회논문지
    • /
    • 제9권5호
    • /
    • pp.430-437
    • /
    • 2004
  • 본 논문에서는 고주파 스위칭 시 스위칭 손실의 감소, 구현의 용이성 및 인버터 제어를 위하여 요구되는 연산시간 감소 등 다양한 장점을 가진 4-Switch 인버터를 대상으로, 새로운 2상 스위칭 패턴(Pattern)과 이에 적용된 새로운 SRP-PWM(Separately Random Pulse Position PWM)기법을 제안한다. 본 논문에서는 고속운전 영역에서의 인버터 출력전류의 고조파 스펙트럼을 넓은 주파수 영역으로 즉, 특정주파수의 side-band로 고루 분산시키는 결과로부터 제안한 스위칭 패턴과 이에 적용된 새로운 SRP-PWM기법의 고조파 저감효과를 확인하고자 한다. 따라서 DSP를 이용한 IGBT인버터에 의한 실험을 수행하고, 이로부터 얻은 결과를 MATLAB/SIMULINK를 이용한 시뮬레이션 결과와 비교ㆍ분석하여 제안된 기법의 타당성을 검증하고자 한다.

조화성분이 베어링 덮개 구조물의 공진에 미치는 영향 (Effect of Harmonic Components on the Resonance of Bearing Casing Structures in a Turbine Rotor System)

  • 송오섭;양경현
    • 한국소음진동공학회논문집
    • /
    • 제17권9호
    • /
    • pp.847-852
    • /
    • 2007
  • Design aspects of a bearing casing system of a power plant are mainly focused on the strength and weight of itself to have a more stable system. Since the rotor speed often passes through the critical speed region when the operation begins, the relation between the rotating frequency of the rotor and natural frequency of the casing is very important for a prevention of resonance. However, harmonic components above the rotating frequency have often been overlooked the design for the resonance avoidance. In this paper, it is revealed that resonance vibration is generated when the natural frequency of a bearing casing is close to the one of harmonics of basic rotating frequency(1x), and as a consequence, sensing qualify of seismoprobes attached to the bearing casing structure can be seriously damaged. In order to reduce the resonance vibration, some stiffeners are added to the casing structures. Significant reduction in the magnitude of vibration corresponding to 2x harmonic of basic rotating frequency is observed from both FE analysis and experiment.

Three-Dimensional Effects on Added Masses of Ship-Like Forms for Higher Harmonic Modes

  • Y.K.,Chon
    • 대한조선학회지
    • /
    • 제25권2호
    • /
    • pp.19-30
    • /
    • 1988
  • Sectional added masses of an elastic beam vibrating vertically on the free surface in higher harmonic modes are evaluated. Hydrodynamic interactions between neighboring sections, which strip theory ignores, are considered for modal wave lengths of the order of magnitude of cross-sectional dimensions of the body. An approximate solution of modified Helmholtz equation which becomes a singular perturbation problem at small wave lengths is secured to get an analytic expression for added masses attending higher harmonic modes. As a bound of the present theory, the modified Helmholtz equation is solved for the long flat plate vibrating at high frequency on the water surface without any limitations on modal frequency. Finally, extensive series of numerical calculations are carried out for ship-like forms. It is found that when modal wave length is comparable to or shorter than a typical cross-sectional dimension of a body, sectional interaction effects are large which result in considerable reductions in added masses. For a fuller section, the ratio of added mass reduction is greater. In the limit of vanishing sectional area, the added masses approach to that of flat plate of equal beam. It is shown that the added mass distribution for a Legendre modal from can be determined form the present theory and that the results agree with the extensive three-dimensional determination of Vorus and Hilarides.

  • PDF

New Reference Generation for a Single-Phase Active Power Filter to Improve Steady State Performance

  • Lee, Ji-Heon;Jeong, Jong-Kyou;Han, Byung-Moon;Bae, Byung-Yeol
    • Journal of Power Electronics
    • /
    • 제10권4호
    • /
    • pp.412-418
    • /
    • 2010
  • This paper proposes a new algorithm to generate a reference signal for an active power filter using a sliding-window FFT operation to improve the steady-state performance of the active power filter. In the proposed algorithm the sliding-window FFT operation is applied to the load current to generate the reference value for the compensating current. The magnitude and phase-angle for each order of harmonics are respectively averaged for 14 periods. Furthermore, the phase-angle delay for each order of harmonics passing through the controller is corrected in advance to improve the compensation performance. The steady-state and transient performance of the proposed algorithm was verified through computer simulations and experimental work with a hardware prototype. A single-phase active power filter with the proposed algorithm can offer a reduction in THD from 75% to 4% when it is applied to a non-linear load composed of a diode bridge and a RC circuit. The active power filter with the proposed reference generation method shows accurate harmonic compensation performance compared with previously developed methods, in which the THD of source current is higher than 5%.

동력 집중식 철도차량의 전력변환장치 전력품질 향상연구 (A Study on Power Quality Improvement of Power Conversion System in Centralized-Power Type Electric Railway Vehicle)

  • 김재문;윤차중;이을재
    • 한국철도학회논문집
    • /
    • 제13권6호
    • /
    • pp.559-564
    • /
    • 2010
  • 본 논문은 동력 집중식 철도차량에서 전력변환장치로서 객차용 전원공급장치의 전력품질을 향상시키기 위해 보완된 필터설계를 제안한다. 먼저, 필터설계를 위해 객차용 전원공급장치와 연결된 변압기의 출력전력 파형을 측정하였다. 실험 및 시뮬레이션 결과를 통해 스위칭 기법은 개선된 특정고조파 소거 펄스폭 변조이고 스위칭 주파수는 300Hz임을 추정하였다. 따라서 추정된 파라미터를 바탕으로 전력품질을 향상시키기 위해 필터를 설계하였다. 시뮬레이션 결과 전체적으로 고조파의 크기가 감소함을 확인하였다.

TACAN용 광대역 안테나 기생소자 최적화 (Optimization of Broadband Antenna Parasitic Elements for TACAN)

  • 박상진;구경헌
    • 한국전자파학회논문지
    • /
    • 제26권5호
    • /
    • pp.483-491
    • /
    • 2015
  • 본 논문은 전술항법장비(Tactical Air Navigation)용 광대역 안테나에 대한 기생소자의 최적화에 대하여 연구하였다. 방위정보를 포함하는 15 Hz와 135 Hz가 합성된 방사 패턴을 생성하고, 규격 MIL-STD-291C에서 요구하는 하모닉 성분 규격을 만족하기 위하여 모터를 이용한 종전의 기계식 회전 안테나 대신 전자적으로 안테나를 회전시키기 위하여 기생소자를 원형 배열로 배치하였다. 기생소자 개수의 최적화에 대하여 전산모의실험을 수행하고, 16개의 15 Hz 기생소자와 63개의 135 Hz 기생소자로 구성된 안테나를 제작하였다. 반사기의 벡터 합성을 이용하여 스텝 수를 증가시킴으로써 하모닉 성분을 줄이고, MIL-STD-291C 규격을 만족한다.