• Title/Summary/Keyword: Reduction of Energy

Search Result 5,085, Processing Time 0.031 seconds

Characteristics of Pt-Ru Catalyst Supported on Activated Carbon for Direct Methanol Fuel Cell

  • Jung, Doo-Hwan;Jung, Jae-Hoon;Hong, Seong-Hwa;Peck, Dong-Hyun;Shin, Dong-Ryul;Kim, Eui-sik
    • Carbon letters
    • /
    • v.4 no.3
    • /
    • pp.121-125
    • /
    • 2003
  • The Pt-Ru/Carbon as an anode catalyst supported on the commercial activated carbon (AC) having high surface area and micropore was characterized for application of Direct Methanol Fuel Cell (DMFC). The Pt-Ru/AC anode catalyst used in this experiment showed the performance of $600\;mA/cm^2$ current density at 0.3 V. The borohydride reduction process using $NaBH_4$, denoted as a process A, showed much higher current and power densities than process B prepared by changing the reduction and washing process of process A. The particle sizes are strongly affected by the reduction process than the specific surface area of raw active carbon and the sizes are almost constant when the specific surface area of carbon are over than the $1200\;m^2/g$. Smaller particle size of catalyst and more narrow intercrystalite distance increased the performance of DMFC.

  • PDF

Indoor Temperature Control of a Heat Pump Based on Model Predictive Control Considering Energy Efficiency (에너지효율을 고려한 모델예측제어에 기초한 열펌프의 실내온도 제어)

  • 조항철;변경석;송재복;장효환;최영돈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.3
    • /
    • pp.200-208
    • /
    • 2001
  • In indoor temperature control of a heat pump, a reduction in energy consumption is very important. However, most control schemes for heat pumps have focused only on control performance such s settling time and steady-state error. In this paper, the model predictive control (MPC) which includes the energy-related variable in this cost function is proposed. By computing the control signal minimizing this cost function, the trade-off between energy reduction and temperature control performance can be obtained. Since the MPC required the process model, the dynamic mode of a heat pump is also obtained by the system identification technique. Performance of the proposed MPC considering energy efficiency is compared with the two other control schemes. It si shown that the proposed scheme can consume less energy thant hte others in achieving similar control performance.

  • PDF

Data Center Remote Management Service for Demanding Forecasting and Reduction of Energy U sage (에너지 수요예측 및 절감을 위한 데이터 센터 원격 관리 서비스)

  • Han, Jong-Hoon;Jung, Dae-Kyo;Bae, Kwang-Yong
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.9 no.3
    • /
    • pp.107-111
    • /
    • 2010
  • This paper is concerned with data center remote management service for demanding forecasting and reduction of energy usage. More particularly, intelligent server rack, mounted on inside of the data center, collects information about energy usage and temperature per server. Using this information, management platform forecasts energy demand in the future and automatically makes report according green environment raw. By providing the remote management service through remote terminals, users are not tied to a time and place to control device inside the data center. In this way, the data center remote management service enhances operability of the facility.

  • PDF

A Study on Optimal Conditions for Organic Matter Reduction and Hydrogen Production Using Electrolysis Process (전기분해공정을 이용한 유기물저감 및 수소 생산을 위한 최적 조건에 관한 연구)

  • AHN, JEONGYOON;RO, YEONHEE;CHANG, SOONWOONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.6
    • /
    • pp.546-552
    • /
    • 2020
  • In this study, optimization research was conducted through statistical analysis with the aim of maximizing the efficiency of organic matter reduction and hydrogen production by applying electrolysis process at sewage treatment plant. Statistical analysis and optimal operating conditions of organic matter removal efficiency and H2 generation, which varied with various conditions in the electrolysis process, were derived using response surface methodology. As a result, 1,268 μS/cm of conductivity, 350 A current, and pH 3.2 was found to be the optimum condition to reach the desired value as 38% of organic matter reduction and 2.58 L/min of H2 production. The experiment also determined that the optimization study was reliable. Base on this study, it was confirmed that the removal of organic matter and hydrogen production could be stably by applying the electrolysis process in the sewage treatment plant.

Energy-based damage-control design of steel frames with steel slit walls

  • Ke, Ke;Chen, Yiyi
    • Structural Engineering and Mechanics
    • /
    • v.52 no.6
    • /
    • pp.1157-1176
    • /
    • 2014
  • The objective of this research is to develop a practical design and assessment approach of steel frames with steel slit walls (SSWs) that focuses on the damage-control behavior to enhance the structural resilience. The yielding sequence of SSWs and frame components is found to be a critical issue for the damage-control behavior and the design of systems. The design concept is validated by the full-scale experiments presented in this paper. Based on a modified energy-balance model, a procedure for designing and assessing the system motivated by the framework regarding the equilibrium of the energy demand and the energy capacity is proposed. The damage-control spectra constructed by strength reduction factors calculated from single-degree-of-freedom systems considering the post stiffness are addressed. A quantitative damage-control index to evaluate the system is also derived. The applicability of the proposed approach is validated by the evaluation of example structures with nonlinear dynamic analyses. The observations regarding the structural response and the prediction during selected ground motions demonstrate that the proposed approach can be applied to damage-control design and assessment of systems with satisfactory accuracy.

Proposal of New Correction Factors for New and Renewable Energy Sources in Public Building (공공건축물에 적용되는 신·재생에너지원의 새로운 보정계수 제안)

  • Kim, Yun-Ho;Park, Yun-Ha;Won, An-Na;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.13-24
    • /
    • 2016
  • The government introduced a mandatory installation system of new & renewable energy for public building to meet the target of greenhouse gas reduction and also suggest a correction factor for new renewable energy to expand the installation of various new & renewable energy systems. The introduction of correction factors, however, was followed by the reduction of installation size of new & renewable energy sources. Assuming that it was caused by a correction factor for each new renewable energy source calculated by the initial costs, this study proposed a new correction factor approach based on payback periods to reflect the technology element in the calculation process of correction factors additionally. The application results of new correction factors show that it was possible to do complex calculations including the economic and technological aspects to select a new & renewable energy system and that the installation size was also enlarged.

Analysis of GHG Reduction Potential on Road Transportation Sector using the LEAP Model - Low Carbon Car Collaboration Fund, Fuel Efficiency, Improving Driving Behavior - (LEAP 모형을 이용한 도로교통부문의 온실가스 감축잠재량 분석 - 저탄소차협력금제도, 연비강화, 운전행태개선을 중심으로 -)

  • Kim, Min wook;Yoon, Young Joong;Han, Jun;Lee, Hwa Soo;Jeon, Eui Chan
    • Journal of Climate Change Research
    • /
    • v.7 no.1
    • /
    • pp.85-93
    • /
    • 2016
  • This study the efficiency of greenhouse gas reduction of 'low carbon car collaboration fund' and its alternative 'control of average fuel efficiency and greenhouse gas', and 'improving driving behavior' were analyzed by using LEAP, long term energy analysis model. Total 4 scenarios were set, baseline scenario, without energy-saving activity, 'low carbon car collaboration fund' scenario, 'fuel efficiency improving scenario', and 'improving driving behavior' scenario. The contents of analysis were forecast of energy demand by scenario and application as well as reduction of greenhouse gas emission volume, and the period taken for analysis was every 1 year during 2015~2030. Baseline scenario, greenhouse gas emission volume in 2015 would be 7,935,697 M/T and 13,081,986 M/T in 2030, increased 64.8%. The analysis result was average annual increase rate of 3.4%. The expected average annual increase rate of other scenarios was, 'low carbon car collaboration fund' scenario 1.7%, 'fuel efficiency improving' scenario 3.0%. and 'improving driving behavior' scenario 3.4%. and these were each 1.7%, 0.3%. 0.3% reduce from baseline scenario. The largest reduction was 'low carbon car collaboration fund' scenario, and there after were 'fuel efficiency improving scenario', and 'improving driving behavior' scenario.

Reduction Characteristics of Oxygen Carriers in a Pressurized Bubbling Fluidized Bed (가압 기포유동층에서 산소전달입자들의 환원반응특성)

  • YOON, JOO-YOUNG;BAE, DAL-HEE;BAEK, JEOM-IN;RYU, HO-JUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.5
    • /
    • pp.589-596
    • /
    • 2016
  • Effects of pressure, temperature, gas velocity, and fuel flow rate on reduction of three oxygen carriers, SDN70, OC-1, OC-2, were measured and investigated in a pressurized bubbling fluidized bed reactor. Among three oxygen carriers OC-2 was selected as the best oxygen carrier in view of fuel conversion and $CO_2$ selectivity. However, all oxygen carriers showed good reactivity even at high pressure conditions. SDN70 particle showed maximum reactivity at $900^{\circ}C$ and low reactivity at $950^{\circ}C$. However, reactivity decay of OC-1 and OC-2 particles at high temperature condition was negligible. The fuel conversion and the $CO_2$ selectivity slightly decreased as the gas velocity increased, whereas they are slightly increased as the fuel concentration increased.

Selection of Oxygen Carrier Candidates for Chemical Looping Combustion by Measurement of Oxygen Transfer Capacity and Attrition Loss (산소전달량 및 마모손실 측정에 의한 매체순환연소용 산소전달입자 후보 선정)

  • KIM, HANA;PARK, JAEHYEON;BAEK, JEOM-IN;RYU, HO-JUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.4
    • /
    • pp.404-411
    • /
    • 2016
  • To select appropriate oxygen carrier candidates for chemical looping combustion, reduction characteristics of seven oxygen carriers were measured and discussed using three different reduction gases, such as $H_2$, CO, and $CH_4$. Moreover, attrition losses of those oxygen carriers also measured and compared. Among seven oxygen carrier particles, OCN703-1100 and NiO/bentonite particles showed higher oxygen transfer capacity than other particles, but these particles showed more attrition loss than other particles. C14 and C28 particles which used as cheap oxygen carriers in European country showed lower oxygen transfer capacity and less attrition loss. Based on the experimental results, we could select OCN717-R1SU, NC001, and N002 particles as candidates for future works because these oxygen carriers showed enough oxygen transfer capacity and good attrition resistance.

Comparative of Energy-Saving by Green Roof Type on Urban Office Building (도심 오피스건물의 옥상녹화 조성 유형별 건물에너지 절감 비교 연구)

  • Kim, Jeong-Ho;Kwon, Ki-Uk;Joo, Chang-Hun;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.23 no.8
    • /
    • pp.1437-1446
    • /
    • 2014
  • This study, the urban energy used office building green roof type composition of the target by analyze building energy reductions. Green roof is total 6 types(type A~F) were selected, EnergyPlus the energy simulation programs were used. Top floor of green roof types evaluation, the reduction of the cooling peak load type E(1.26%), type D(1.30%), type C(1.37%), type B(1.45%), type F(1.49%), and heating peak load is type D(1.32%), type E(1.40%), type C(1.47%), type F(1.69%), type B(2.13%) order. Annual cooling load of heating load is reduced more than about 1% effect. The heating load reduction ratio for a maximum of 9% respectively. Cooling peak load of the building energy performance evaluation of type F > type B > type C > type D > type E in the order and in the case of peak loads heating type B > type F > type D > type E>type C order. Annual total energy use reduction of 1.07 to 1.22% and earn, type B in the best good. In primary energy use reductions in the presence of a green roof were in the 4249~4876 kWh/yr. Annual $CO_2$ emissions reductions of unapplied type A were analyzed on average 469.78 kg.