• Title/Summary/Keyword: Reduction measurement

Search Result 1,791, Processing Time 0.029 seconds

SPDR Scheme for Disturbance Reduction in ROT Process with Measurement Delay (측정지연이 있는 ROT 공정의 외란제거를 위한 SPDR 제어기 설계)

  • Park, Cheol Jae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.10
    • /
    • pp.1023-1029
    • /
    • 2014
  • In this paper, we propose an SPDR (Smith Predictor for Disturbance Reduction) scheme to improve the temperature control by reduction of the disturbance in ROT process with measurement delay. The proposed controller is a combination of Astrom's modified Smith predictor with a disturbance reduction controller and a grey predictor. The grey prediction is used to calculate the inverse of the measurement delay and to predict future variations and tendencies of system output. The simulation results demonstrate the successful performance of the proposed disturbance reduction controller and enhance the robustness of the proposed control scheme.

Study on Measurement Error Reduction Technique when Measuring Touch and Step Voltage of Grounding System (접지시스템의 접촉전압 및 보폭전압 측정오차 감소 기법에 관한 연구)

  • Kim, Dong-Woo;Lim, Young-Bea;Lee, Sang-Ick;Choi, Myeong-Il;Moon, Hyun-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.188-195
    • /
    • 2015
  • This paper presents measurement error reduction technique of touch and step voltage of grounding system based on numerical analysis. When measuring touch and step voltage of grounding system, auxiliary current probes should be located at suitable places. However, the auxiliary probes can not be located at suitable places in such cases as there are buildings and pavements. Therefore, in this paper, we provided measurement error reduction technique of touch and step voltage of grounding system according to the positions of auxiliary probes and angle between auxiliary probes. Also, measurement error analyses of touch and step voltage of grounding system have been conducted using more than one current probe. Based on these analyses, recommended positions of auxiliary probes within allowable measurement errors were presented.

Detection of tension force reduction in a post-tensioning tendon using pulsed-eddy-current measurement

  • Kim, Ji-Min;Lee, Jun;Sohn, Hoon
    • Structural Engineering and Mechanics
    • /
    • v.65 no.2
    • /
    • pp.129-139
    • /
    • 2018
  • Post-tensioning (PT) tendons are commonly used for the assembly of modularized concrete members, and tension is applied to the tendons during construction to facilitate the integrated behavior of the members. However, the tension in a PT tendon decreases over time due to steel corrosion and concrete creep, and consequently, the stress on the anchor head that secures the PT tendon also diminishes. This study proposes an automatic detection system to identify tension reduction in a PT tendon using pulsed-eddy-current (PEC) measurement. An eddy-current sensor is installed on the surface of the steel anchor head. The sensor creates a pulsed excitation to the driving coil and measures the resulting PEC response using the pick-up coil. The basic premise is that the tension reduction of a PT tendon results in stress reduction on the anchor head surface and a change in the PEC intensity measured by the pick-up coil. Thus, PEC measurement is used to detect the reduction of the anchor head stress and consequently the reduction of the PT tendon force below a certain threshold value. The advantages of the proposed PEC-based tension-reduction-detection (PTRD) system are (1) a low-cost (< $ 30), low-power (< 2 Watts) sensor, (2) a short inspection time (< 10 seconds), (3) high reliability and (4) the potential for embedded sensing. A 3.3 m long full-scale monostrand PT tendon was used to evaluate the performance of the proposed PTRD system. The PT tendon was tensioned to 180 kN using a custom universal tensile machine, and the tension was decreased to 0 kN at 20 kN intervals. At each tension, the PEC responses were measured, and tension reduction was successfully detected.

Measurement error reduction technique for the Semiconductor Device DC Characteristic Measurement System (반도체 소자의 직류특성 측정 시스템에서의 저전류 측정 오차 감소 기법)

  • Choi, In-Kyu;Jung, Hae-Yone;Park, Jong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.352-355
    • /
    • 2001
  • In this paper, we proposed measurement error reduction technique for the semiconductor device DC characteristic measurement system. Implemented system is composed of 4 SMUs, 2 VSUs, and 2 VMUs. Various efforts in hardware and software have been made to reduce the measurement errors due to the leakage current in measurement circuits. Internal and external sources of errors in measurement system especially in pA range measurement have been identified and removed. Experimental results show that the implemented system can be measure the DC characteristic of semiconductor devices in pA level.

  • PDF

Improvement of ECG Measurement for the Elderly's U-healthcare Clothing Using 3D Tight-fit Pattern (3D패턴을 이용한 노인용 u-헬스케어 의복의 심전도 측정 연구)

  • Park, Hye-Jun;Shin, Seung-Chul;Shon, Boo-Hyun;Hong, Kyung-Hi
    • Fashion & Textile Research Journal
    • /
    • v.10 no.5
    • /
    • pp.676-682
    • /
    • 2008
  • In this study a guideline of the 3D-fit pattern for the ECG(electrocardiogram) measurement of elderly's u-healthcare clothes was proposed. In the screening test of the ECG measurement band, ECG peak band was observable at the band pressure of 0.20 kPa. By employing a 3D body image, tight-fit 3D patterns were made at two different reduction rates of 21%(pattern 1) and 33%(pattern 2), and corresponding pressure of both of the clothes were 0.25 kPa and 0.54 kPa, respectively. Typical waves of ECG were found in both stationary and moving position. In terms of the subjective evaluation of the u-healthcare clothes when worn, it was confirmed that reduction pattern 1(0.25 kPa) conveyed comfortable clothing pressure and pleasantness, which is very close to the result of screening test of ECG band experiment. As results, it is recommended that reduction rate should be adjusted, so that clothing pressure is about 0.2 kPa for the elderly's comfortable and efficient u-healthcare clothes.

A study on the performance test and acoustic design of interference type noise reduction device for railway noise (철도소음 저감을 위한 간섭형 방음장치 음향 설계 및 성능시험에 관한 연구)

  • Cho, Jun-Ho;Koh, Hyo-In
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.6
    • /
    • pp.787-795
    • /
    • 2011
  • Noise barrier is generally used with welding of joint rail for railway noise reduction in our country. But the noise barrier for high speed railway has weak point in low frequencies about 315Hz band. In this study, For developing of Interference-type Noise Reduction Device(INRD), acoustic analysis were performed using commercial software. For verifying the improvement in the noise reduction, noise measurement before and after installing of INRD were performed in Anechoic Chamber. From these acoustic analysis and noise measurement, it was known that developed INRD has a good noise reduction performance and can be used efficiently with conventional noise barrier.

Economic Effect of National Measurement Standards (측정표준의 국민경제 기여효과 분석)

  • 안병덕;남경희;안웅환;김동진;조연상
    • Journal of Korea Technology Innovation Society
    • /
    • v.5 no.2
    • /
    • pp.245-256
    • /
    • 2002
  • Measurement standards, as being widely recognized, is necessary for national economic development and advanced industrialization. Also measurement standards give reliability and fair trade to the producers and consumers. Macro-effect of measurement standards using estimation of cost function has four effects: 1) value-added causing effect, 2) effect of employment, 3) reduction effect transaction cost, 4) reduction effect defect rates. In this study, to investigate the impacts between specific and the other industries, we used I-O Table of Korea Bank. The relation between the value-added produced by original production factors and final use is determined through production level, and the relation can be investigated with production causing coefficient matrix. In this study, it was showed that the measurement standards investments including measurement only man power of industries were increased from 1995 rapidly. The establishment and maintenance of measurement standards contributes to reduce the defect rate of products in production process and improve the confidence of the product quality. The results from this study show that measurement technology contributes to improve quality, decrease defect rate, improve production process, develope new products, reduce prime cost and increase the consumer's confidence on the firms. Since these results indicate that measurement standards are very important in the point of their vast contribution, we hope our findings can contribute to encourage measurement activities in industries.

  • PDF

Vibration Reduction of Optical Storage Disk Drive Using Piezoelectric Shunt (압전 션트회로를 이용한 광저장 디스크 드라이브의 진동 저감)

  • 박종성;임수철;최승복;김재환;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.381-386
    • /
    • 2002
  • This paper presents a piezoelectric shunt methodology to reduce unwanted vibration of optical disk drive(O.D.D.). After briefly investigating a second-order mechanical vibration absorber model, the O.D.D. structure is incorporated with the piezoelectric shunt circuit. In order to evaluate feasibility of multi-mode passive damping of the structure, admittance measurement of piezoceramic is undertaken. The parameters are optimally tuned by admittance measurement results on the basis of the circuit model and displacement transmissibility is evaluated. To verify validity of admittance measurement result, experiment is performed and vibration reduction is achieved at two different modes.

  • PDF

Synthesis of FDR-SPC Resin and PIV Measurement for Frictional Drag-reduction (마찰저항 저감을 위한 고분자 수지 합성 및 PIV 유동장 계측)

  • Chung, Sungwoo;Kim, Eunyoung;Chun, Ho Hwan;Park, Hyun;Lee, Inwon
    • Journal of the Korean Society of Visualization
    • /
    • v.12 no.1
    • /
    • pp.49-53
    • /
    • 2014
  • In this study, a novel FDR-SPC is first synthesized in this study. The drag reducing functional radical such as PEGMA (Poly(ethylene) glycol methacrylate) has been utilized to participate in the synthesis process of the SPC. The types of the baseline SPC monomers, the molecular weight and the mole fraction of PEGMA were varied in the synthesis process. The resulting SPCs were coated to the substrate plates for the subsequent hydrodynamic test for skin friction measurement. In a low-Reynolds number flow measurement using PIV (Particle Image Velocimeter), a significant reduction in Reynolds stress was observed in a range of specimen, with the maximum drag reduction being 15.9% relative to the smooth surface.

Verification on the Reduction Technique of Measurement Time of Total Radiated Power (TRP) by Using Effective Isotropic Radiated Power (EIRP) in 5G Frequency Band (유효등방복사전력(EIRP)을 활용한 5G 주파수 대역 총복사전력(TRP) 측정시간의 단축방안 검증)

  • Kim, Dong-Woo;Oh, Soon-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.5
    • /
    • pp.835-840
    • /
    • 2020
  • In this paper, we described the verification results on method by using the computer simulation and practical experiment for reduction of total radiated power (TRP) measurement time consuming tens of hours. TRP measurements are used in the 5G band in order to exactly evaluate the wireless communication equipment, but it takes a long measurement time because of dense sampling interval. Moreover, if there are various beam forming scenarios, the total measurement time increases exponentially. Therefore, the world-wide research on reduction method of the TRP measurement time is intensively on going. The verified method in this paper is to calculate the TRP through effective isotropical radiated power (EIRP). At first, the relation of TRP and EIRP was investigated, and an antenna for testing was designed and constructed. And, the amount of error was analyzed through simulation and measurement. The analysed results showed that the derived TRP through EIRP has very small error. This method could be applied for TRP measurements of 5G wireless communication equipments.