• Title/Summary/Keyword: Reduction facility

Search Result 617, Processing Time 0.023 seconds

A Case Study of the Improvement of the Structural Work of a Logistics Facility by Using PC Member (PC부재에 의한 물류시설의 골조공사 개선사례 연구)

  • Kim, Seon-Hyung;Choi, Eun-Gyu;Kim, Sun-Kuk;Lee, Sung-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.6
    • /
    • pp.127-135
    • /
    • 2010
  • As logistics facilities have a high ceiling height, simple structure, and the need for a quick return on investment, it is usually essential to advance the construction schedule of such facilities. Accordingly, PC structures, which require less labor, cost and schedule, can be more competitive than RC structures. However, most construction companies in Korea are familiar with RC structure design, have negative perceptions regarding PC structures, and do not sufficiently adopt new construction techniques. The structure that this research features has 110 columns that are 14 m high and are built to the same specification, and applying an RC design to the structure will lead to issues related to constructibility, economic viability, project duration and safety. Therefore, this study intends to feature PC design as an alternative to the RC warehouse design, and perform a comparative analysis of the reduction in labor, cost and construction schedule to highlight benefits. The research outcomes herein will provide inputs to subsequent studies on new construction strategies to advance the construction schedule, improve quality and constructibility, enhance safety and save costs.

The Monitoring of Growth Conditions Regarding Korea Endemic Species and Natural Characteristics - Applied to Facilities Area on Highway Roadside - (한국특산식물 및 종의 자생지 특성을 고려한 식재 후 생육상태 모니터링 - 고속도로변 시설지를 대상으로 -)

  • Park, Sung-Su;Hong, Kwang-Woo;Kim, Sae-Cheon;Lee, Hyo-Yeom
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.6
    • /
    • pp.1-9
    • /
    • 2017
  • This study investigates the environmental factors of endemic species in Korea in order to understand their ecological characteristics, and to investigate the target species of their natural habitats to find similar sites. The purpose is to restore and follow suitable growth methods for the appropriate highway facility of target species to establish a management system via monitoring. This study endeavors to restore the target species near highway facilities on the basis of monitoring data and restore sites have similar natural characteristics of the target species. After restoring the target species, a restoration strategy and management plan will be established for breeding and continuation. The restoration strategy and management plan of the target species is divided into breeding, restoring, maintaining and monitoring plans. Specially management plans include several divisions such as soil, water, non-point pollution source reduction and naturalized plants. The results of this study can be used as reference materials for the restoration of endemic Korean plants in the future of highway routes, and for systematic management measures in habitats.

Outside Temperature Prediction Based on Artificial Neural Network for Estimating the Heating Load in Greenhouse (인공신경망 기반 온실 외부 온도 예측을 통한 난방부하 추정)

  • Kim, Sang Yeob;Park, Kyoung Sub;Ryu, Keun Ho
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.7 no.4
    • /
    • pp.129-134
    • /
    • 2018
  • Recently, the artificial neural network (ANN) model is a promising technique in the prediction, numerical control, robot control and pattern recognition. We predicted the outside temperature of greenhouse using ANN and utilized the model in greenhouse control. The performance of ANN model was evaluated and compared with multiple regression model(MRM) and support vector machine (SVM) model. The 10-fold cross validation was used as the evaluation method. In order to improve the prediction performance, the data reduction was performed by correlation analysis and new factor were extracted from measured data to improve the reliability of training data. The backpropagation algorithm was used for constructing ANN, multiple regression model was constructed by M5 method. And SVM model was constructed by epsilon-SVM method. As the result showed that the RMSE (Root Mean Squared Error) value of ANN, MRM and SVM were 0.9256, 1.8503 and 7.5521 respectively. In addition, by applying the prediction model to greenhouse heating load calculation, it can increase the income by reducing the energy cost in the greenhouse. The heating load of the experimented greenhouse was 3326.4kcal/h and the fuel consumption was estimated to be 453.8L as the total heating time is $10000^{\circ}C/h$. Therefore, data mining technology of ANN can be applied to various agricultural fields such as precise greenhouse control, cultivation techniques, and harvest prediction, thereby contributing to the development of smart agriculture.

Analysis of Energy Consumption Pattern and Greenhouse Gas Emission in the Academic Facility (대학에서의 에너지 소비패턴 및 온실가스 배출현황 분석)

  • Kim, Jin-Sik;Lee, Kyoung-Bin;Lee, Im-Hack;Kim, Shin-Do
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.9
    • /
    • pp.604-612
    • /
    • 2012
  • Self-management plan for GHG (Greenhouse Gas) reduction should be prepared in academic facilities, which occupy a large amount of energy consumption. In this study, a university was chosen as one of the major academic facilities and its energy consuming pattern and GHG emission were analyzed. The results have shown that annual $CO_2$ emission from university buildings was 10,452 ton-$CO_2$ (0.65 ton-$CO_2/m^2$), and dependent upon 78.0% electricity, 20.5% LNG and 1.5% oil, respectively as energy sources. According to more detail analysis by usage of energy consumption, appliances occupies 36.7% followed by gas heating (18.9%), lighting (18.6%), heating with electricity (12.5%), cooling with electricity (10.2%), transportation (1.5%), gas cooling (1.2%) and cooking (0.4%). Furthermore, annual $CO_2$ emissions per unit area and a student by electricity usage were evaluated to 51.30 kg-$CO_2/m^2$ and 981.86 kg-$CO_2$/capita, respectively and those by LNG usage were 14.61 kg-$CO_2/m^2$ and 241.01 kg-$CO_2$/capita.

A Study on the Planning Technique of High-rised Housing Estates Applying Smart Green City Concept : Focus on Multi-functional Administrative City 2-1 Neighborhood (스마트 그린시티 개념을 적용한 고층주거단지 계획기법에 관한 연구 : 행정중심복합도시 2-1생활권을 중심으로)

  • Lee, Seo-Jeong;Lee, Eung-Hyun;Oh, Deog-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.379-387
    • /
    • 2016
  • The goal of this research is to identify the planning techniques of high-rise housing estates applying a smart green city concept in order to understand the necessity of integrating 'planning & building' planning techniques and 'smart system' planning techniques and to analyze the current status of application. For the research, firstl, the definition of smart green city was established and high-rise housing estates planning was categorized according to a three space hierarchy, seven planning directions and 17 major features through literature review. Second, 28 'planning & building' planning techniques and 'smart system' planning techniques were derived through literature review and FGI analysis. Last, four cases in Multi-functional Administrative City were analyzed for the current status of application of planning techniques. In conclusion, planning techniques in 'Transportation Network', 'Environment-friendly layout planning of housing', 'Revitalization of green transportation', 'Utilization of new & renewable energy', 'Crime prevention and accident reduction', 'Use of high performance, and efficiency facility' main feature were identified as important planning techniques for Smart Green City and its implications were estimated.

Cause Analysis for Reduced Effect of Sewer Pipe Improvement Project Based On Investigation of Interceptor Sewers (차집관로의 조사 및 분석을 통한 하수관로정비 사업의 효과 감소 원인 분석)

  • Chae, Myungbyung;Bae, Younghye;Kim, Hungsoo
    • Journal of Wetlands Research
    • /
    • v.20 no.3
    • /
    • pp.219-226
    • /
    • 2018
  • Interceptor sewer is installed underground near to the river side mostly ofstate-owned land and the management efficiency of public sewage disposal facilities is decreasing as too much infiltration/inflow(I/I) and river flow to interceptor sewer are caused by broken or deteriorated sewer. This also affects the sewer pipeline project and decreases its efficiency. Therefore, the aim of this study is to investigate interceptor sewer which has influence on the reduction of the project effect. The investigation were performed for three study areas. The study includes the investigation of current condition of interceptor sewer(sewer extension, pipe diameter, pipe type, installed year, installed locations, etc), investigation of inside of sewer by CCTV accompanied by pumping and dredging works where required, investigation of inside of manholes by eyes, calculation of pollutant load using the results of investigation of flow quantity and quality. Multipoint investigations were simultaneously performed for flow quantity at confluence area and other investigations were also performed for flow quantity and BOD for interceptor sewer and comparison of pollutant load, investigation of infiltration/inflow(I/I) caused by deterioration of interceptor sewer. As the result of the study, a main reason for reduced effect of sewer pipe improvement project was analyzed as the low-density sewage and I/I in public seweage treatment Facility due to deteriorated and unmanaged interceptor sewers.

Survival of Bacillus cereus and Its Transfer from Agricultural Product-Contact Surfaces to Lettuce (Bacillus cereus의 농산물 접촉 표면 재질별 생존력 및 상추로의 교차오염도 조사)

  • Kim, Se-Ri;Seo, Min-Kyoung;Kim, Won-Il;Ryu, Kyoung Yul;Kim, Byung-Seok;Ryu, Jae-Gee;Kim, Hwang-Yong
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.4
    • /
    • pp.253-259
    • /
    • 2014
  • This study was conducted to investigate survival of Bacillus cereus (B. cereus) on stainless steel and polyvinyl chloride (PVC) and its transfer from two material to lettuce. The stainless steel and PVC were innoculated with B. cereus and stored at 6 combination conditions (temperature : $20^{\circ}C$ and $30^{\circ}C$, relative humidity (RH) : 43%, 69%, and 100%). Although the total numbers of B. cereus at RH 43% and RH 69% were reduced by 3.53-4.00 log CFU/coupon within 24 h regardless of material type, the spore numbers of B. cereus was lasted at 3.0 log CFU/coupon. When two materials were stored at $30^{\circ}C$, RH 100%, the spore numbers of B. cereus was rapidly increased by 3.0 log CFU/coupon. In addition, the reduction rate of B. cereus was decreased in the presence of organic matter. Transfer rate of B. cereus from surface of stainless steel and PVC to lettuce was increased by 10 times in the presence of water on the lettuce surface. As a result of this study, the presence of B. cereus on produce contact surfaces can increase the risk of cross-contamination. Thus, it is important that the packing table and conveyer belt in post harvest facility should be properly washed and sanitized after working to prevent cross-contamination.

Analysing Disaster Cases on Construction Sites to Prevent Falling Disaster of Hanging Scaffolding (건설현장 달비계 추락재해 예방을 위한 사례분석 연구)

  • Lim, HyoungChul;Kim, DaeYoung;Jeong, SeongChoon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.6
    • /
    • pp.66-73
    • /
    • 2019
  • Thanks to various efforts to reduce disasters by the government and the Health and Safety Authority, disasters across industries and the construction industry show their reduction trend. However, the falling disasters in the construction industry have not decreased and increased on the contrary. Especially falling disaster caused by Hanging Scaffolding is the most critical disaster which shows low occurrence frequency but is directly connected to death of worker. The working environment for Hanging Scaffolding is poor in domestic construction site. In particular, the Hanging Scaffolding workers in small construction sites are not on the safety control and management by anyone for their works. They are driven to unsafe working condition with mostly uncertified facilities which are made by themselves. Therefore, this study is focused on searching falling disaster factors from the 242 disaster cases caused by Hanging Scaffolding Work in 15 years presented by KOSHA, and trying to provide suggestions for improvement. The improvement of the method of work requires facility improvement and work due to high accident rate caused by unsafe behavior. Analysis of the case of a disaster occurring over the past 15 years shows that no disaster occurred due to problems in the order of operations presented by KOSHA. However, it was found that many accidents resulted from death caused by safety belts not being installed or attached to ropes using safety belts without following the order of work. The most important aspect of improving the work method was the installation and wearing of lifeboats and safety belts.

Analysis of reduction effect of non-point sources pollution facility in Juam dam watershed using HSPF model (HSPF 유역모형을 이용한 주암댐 유역 비점오염물질 저감시설 효과 분석)

  • Yi, Hye-Suk;Chong, Sun-A;Choi, Kwangsoon;Kim, Dong-Sup;Lee, Seungyoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.498-498
    • /
    • 2016
  • 광역상수원으로 활용되는 주암댐 저수지 및 동복댐 저수지가 위치하고 있는 유역을 대상으로 유역모형을 적용하여 비점오염 저감시설에 따른 수지개선효과를 분석하였다. 주암댐 유역은 보성강 수계에 위치하고 있으며 전체 유역면적은 약 $1,010km^2$으로 담양군, 보성군, 장흥군, 화순군 및 순천시에 걸쳐 위치하고 있다. 비점오염원 설치지점을 고려하기 위하여 소유역별 비점오염원 부하량 산정이 가능하고 BMPs 효과분석 모의가 가능한 HSPF 유역모델을 적용하여 2011~2012년을 대상으로 유량, BOD, TN, TP 재현성을 검증하였다. 29개 소유역별 비점오염원 부하량 평가를 통해 중점관리지역을 선정하였으며 비점오염원 저감시설 설치 시나리오 4개를 적용하여 수질개선 효과를 비교 분석하였다. BOD, TN, TP 모두 주암호 유역 상류에 위치하는 보성강댐 소유역에서 상대적으로 높은 비점오염원 부하량이 유출되는 것으로 분석되었으며 특히, TN에서 가장 뚜렷하게 나타났다. 비점오염 저감시설의 누적유출고와 배수면적을 고려하여 비점오염 저감시설로 저류지를 선정하였으며 누적유출고 5 mm/d와 전체유역면적을 고려한 시나리오 1, 누적유출고 5mm/d와 산림을 제외한 유역면적을 고려한 시나리오 2, 누적유출고 24.5 mm/d와 전체유역면적을 고려한 시나리오 3, 누적유출고 24.5 mm/d와 산림을 제외한 유역면적을 고려한 시나리오 4로 구분하여 적용하였다. BOD의 경우, 2011년 조건에서 시나리오 1은 각 소유역별 평균 13.1%, 시나리오 2는 3.7%, 시나리오 3은 15.8%, 시나리오 4는 4.4%의 비점오염원 부하량 저감효과가 나타났으며 2012년 조건에서는 각 시나리오별로 평균 13.1%, 3.6%, 15.7%, 4.3%의 저감효과가 나타나는 것으로 분석되었다. TN의 경우, 2011년 조건에서 시나리오별로 평균 10.9%, 3.0%, 13.0%, 3.6%, 2012년 조건에서도 유사한 범위로 비점오염원 부하량 저감효과가 분석되었다. TP의 경우, 2011년 조건에서 시나리오별로 평균 13.7%, 3.8%, 16.5%, 4.6%, 2012년 조건에서는 13.7%, 3.8%, 16.4%, 4.6%로 분석되었다. 주암댐 유역의 중점 관리지역을 선정하여 누적유출고 24.5mm/d와 전체유역면적을 고려한 저류지를 설치할 경우 효과가 가장 큰 것으로 나타났으며 평균 BOD 15.8%, TN 13.3%, TP 16.5%의 저감효과로 분석되었다.

  • PDF

Backfill Materials for Underground Facility with Recycling Materials - Small-Scaled Laboratory Chamber Test and FEM Analysis (재활용재료를 이용한 지하매설물용 뒤채움재 - 모형챔버실험 및 유한요소해석)

  • Lee, Kwan-Ho;Lee, Kyung-Jung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.3
    • /
    • pp.97-103
    • /
    • 2011
  • In this research, a small-scaled laboratory test and FEM analysis have been carried out to evaluate the feasibility of field construction with couple of recycled materials, such as in-situ soil, water-treatment sludge, and crumb rubbers. A static loading, which simulates the real traffic load, was adopted in lab test. The test was carried out, according to simulated field construction stages, such as excavation, bedding materials and pipe installation, placing and curing of controlled low strength materials, and simulated traffic loading. Couple of measuring instruments were adopted. The maximum vertical and horizontal deformations were 0.83% and 1.09%, during placing the CLSM. The measured vertical and horizontal deformations with curing time were 0.603mm and 0.676mm, respectively. The reduction effect of vertical and lateral earth pressure was relatively big. Also, FEM analysis was carried out to get the deformation, earth pressure and strain of PVC with different Controlled Low Strength Materials(CLSM) materials.