• 제목/요약/키워드: Reduction agent

검색결과 1,040건 처리시간 0.026초

블리딩 저감제를 사용한 콘크리트의 성능분석에 관한 실험적 연구 (An Experimental Study on the Properties Analysis of Concrete Using Bleeding Reduction Agent)

  • 전충근;김경민;황인성;신병철;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.669-674
    • /
    • 2002
  • This paper describes the properties analysis of concrete using bleeding reduction agent. According to the results, the fluidity and the air content of fresh concrete with increase of bleeding reduction agent show little difference in compare with plain concrete which does not use bleeding reduction agent. The efficiency of bleeding reduction agent is confirmed because in variation of W/C and slump, the increase of bleeding reduction agent dosage reduces bleeding remarkably. And the compressive strength of hardened concrete does not show any differences with increase the dosage of bleeding reduction agent. Bleeding reduction agent does not have bad effect on the quality of concrete such as fluidity, air content and the strength of hardened concrete and so on, the dosage of it can reduce bleeding effectively.

  • PDF

블리딩저감용 AE감수제를 사용한 콘크리트의 블리딩 저감 특성 (Properties of Bleeding Reduction of Concrete Using AE Water Reducing Agent for Reduction of Bleeding)

  • 김기훈;황인성;나운;임주혁;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문 발표회
    • /
    • pp.69-72
    • /
    • 2003
  • This study is intended to investigate the fundamental properties of concrete which AE water reducing agent for reduction of bleeding is used, and the properties of bleeding reduction. According to the results, when the adding ratio of AE water reducing agent for reduction of bleeding increases, a range of normal fluidity and aimed air content arc satisfied, setting time is faster than that of normal AE water reducing agent. And bleeding amount decreases, bleeding speed is highest between 60 and 90 min, and sinking depth increases drastically in 60 min. When, AE water reducing agent for reduction of bleeding is added, compressive strength shows a slight variation by air content, but there is not a large influence by addition of AE water reducing agent for reduction of bleeding. Synthetically, it proves that AE water reducing agent for reduction of bleeding satisfies aimed air content in the range of normal slump and can reduce only bleeding without quality variation of compressive strength.

  • PDF

블리딩저감용 AE감수제를 사용한 콘크리트의 블리딩 저감 특성 (Properties of Bleeding Reduction of Concrete Using AE Water Reducing Agent for Reduction of Bleeding)

  • 김기훈;황인성;나운;임주혁;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.69-72
    • /
    • 2003
  • This study is intended to investigate the fundamental properties of concrete which AE water reducing agent for reduction of bleeding is used, and the properties of bleeding reduction. According to the results, when the adding ratio of AE water reducing agent for reduction of bleeding increases, a range of normal fluidity and aimed air content are satisfied, setting time is faster than that of normal AE water reducing agent. And bleeding amount decreases, bleeding speed is highest between 60 and 90 min, and sinking depth increases drastically in 60 min. When. AE water reducing agent for reduction of bleeding is added, compressive strength shows a slight variation by air content, but there is not a large influence by addition of AE water reducing agent for reduction of bleeding. Synthetically, it proves that AE water reducing agent for reduction of bleeding satisfies aimed air content in the range of normal slump and can reduce only bleeding without quality variation of compressive strength.

  • PDF

블리딩저감형 AE감수제를 사용한 콘크리트의 공학적 특성 (Engineering Properties of Bleeding Reduction of Concrete Using AE Water Reducing Agent for the Type of Bleeding Reduction)

  • 한천구;황인성;이승훈;김규동
    • 한국건축시공학회지
    • /
    • 제4권1호
    • /
    • pp.133-140
    • /
    • 2004
  • This study is intended to investigate the properties of bleeding reduction of concrete using AE water reducing agent for the type of bleeding reduction with the replacement admixture. According to the results, when the adding ratio of AE water reducing agent for the type of bleeding reduction increases, a range of normal fluidity and aimed air content are satisfied, setting time is faster than that of normal AE water reducing agent. And bleeding amount decreases, bleeding speed is highest between 60 and 90 min, and sinking depth increases drastically in 50 min. When AE oater reducing agent for the type of bleeding reduction is added, compressive strength shows a slight variation by air content, but there is not a large influence by addition of AE water reducing agent for the type of bleeding reduction. Synthetically, it proves that AE water reducing agent for the type of bleeding reduction satisfies aimed air content in the range of normal slump and can reduce only bleeding without quality variation of compressive strength.

전기로 환원 슬래그를 이용한 연약지반 고화재 개발에 관한 실험적 연구 (An Experimental Study on the Development of Soft Ground Firming Agent Using EAF Reduction Slag)

  • 이강석;이윤규;최재석;한만해
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.998-1001
    • /
    • 2010
  • Most firming agent used in Korea is cement-firming agent. Cement-firming agent absorb water for combination, and then it makes ettringite. Through this chemical process, soft ground is firmed by cement-firming agent. Although most cement-firming agent used in Korea made from CSA, it relies on imports. Therefore, the development of soft ground firming agent using new materials is required. In this study, we suggested that EAF reduction slag not used for anything in the steel industry is available for material of soft ground firming agent. If EAF reduction slag is used in soft ground firming agent, it will be possible to solve the problem with treatment of slag and improvement of soft ground.

  • PDF

감수제의 감수 효율에 따른 다성분계 결합재를 사용한 콘크리트의 물리적 특성에 관한 기초적 연구 (A Study on the Physical Characteristics of Concrete using Multi-Component Blended Binder According to Warter Reduction Efficiency of Warter Reduction Agent)

  • 김경환;오성록;최병걸;최연왕
    • 콘크리트학회논문집
    • /
    • 제27권5호
    • /
    • pp.559-568
    • /
    • 2015
  • 본 연구에서는 감수제의 감수 효율에 따른 다성분계 결합재를 사용한 콘크리트의 물리적 특성에 대한 영향을 평가하기 위하여 고성능 감수제의 종류 3수준(0%, 8% 및 16%) 및 물-결합재비 3수준(40%, 45% 및 50%)에 따른 플라이애시 및 고로슬래그 미분말을 사용한 다성분계 콘크리트 배합을 제조하였다. 또한, 신뢰성 확보를 위하여 콘크리트 배합은 3회 반복실험을 실시하였다. 실험결과, 감수제 종류에 따른 압축강도는 약 20% 이상의 압축강도 차이가 발생하였으며, 감수제의 감수 효율이 콘크리트의 품질에 크게 영향을 미치는 것으로 나타났다. 따라서 감수제의 감수 효율을 반영한 다성분계 콘크리트의 압축강도 예측 모델식을 도출하였으며, 90% 이상의 높은 상관성이 있는 것으로 나타났다.

콘크리트용 블리딩저감제의 개발 및 실용성 검토 (Development and Analysing the Practical Use of Bleeding Reduction Agent for Concrete)

  • 한천구;황인성;신동인
    • 콘크리트학회논문집
    • /
    • 제15권2호
    • /
    • pp.217-224
    • /
    • 2003
  • 블리딩은 재료분리의 일종으로 콘크리트 구조물의 품질을 향상시키기 위해서는 손쉬운 블리딩 저감방안이 요구되고 있다. 그러나, 지금까지 알려진 블리딩 저감대책으로는 재료의 고품질화 및 배합비를 조정하는 등의 방법 외에는 손쉬운 해결책이 없는 실정이었다. 그러므로, 본 연구에서는 콘크리트의 블리딩을 효과적으로 저감할 수 있는 증점제 Type 블리딩저감제의 개발과 그 실용성을 검토한 것으로, 실험결과는 다음과 같다. 즉, 블리딩저감제의 개발은 MC 증점제 : 소포제 : 유동화제를 1 : 0.004 : 0.2의 비율로 혼합하면 가능한 것으로 밝혀졌고. 또한, 개발된 블리딩저감제는 혼입률 증가에 따라 굳지 않은 콘크리트의 유동성, 공기량 및 경화 콘크리트의 압축강도, 내동해성 등 제반 품질은 변동 없고, 블리딩의 저감효과는 우수한 것으로 나타나, 실무에서 콘크리트용 블리딩저감제로 유효하게 활용할 수 있음이 밝혀졌다.

라돈 저감제를 이용한 건축자재의 라돈 방출 저감 연구 (A Study on Radon Emission Reduction of Construction Materials using Radon-reducing Agent)

  • 박경북;이상혁
    • 한국환경보건학회지
    • /
    • 제40권6호
    • /
    • pp.484-491
    • /
    • 2014
  • Objectives: A radon emission reducing agent was prepared using charcoal and zeolite, and the amount was measured after coating construction materials with the agent. The availability of the radon emission reducing agent was evaluated. Methods: Construction materials (red brick, cement brick, and gypsum board) coated with reducing agent were placed in a chamber to measure radon emissions. The construction materials were coated one through three times. The spread volume for brick and gypsum board was 50 mL and 75 mL per application, respectively. The amount of radon emitted was measured by RAD-7 after 48 hours. Results: The reduction ratio increased with the number of coatings, and the reduction ratios for red brick, cement brick, and gypsum board were 63.3, 73.6, and 58%, respectively, in the case of three coatings of RA-1. The reduction ratios for red brick, cement brick, and gypsum board were 42.8, 58.1, and 26.2%, respectively in the case of three coatings with RA-2. RA-1 was slightly better than RA-2 in radon emission reduction. Conclusions: Radon emissions from construction materials decreased according to the concentration of reducing agent coating, and it was more effective than existing methods.

블리딩 저감용 AE감수제 개발에 관한 기초적 연구 (A Fundamental Study on the Development of AE Water Reducing Agent for Reduction of Bleeding)

  • 문학용;김한준;김규용;신동인;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.75-78
    • /
    • 2003
  • This study is to investigate the probability to develop the AE Water-reducing agent which can decrease the bleeding by mixing melamine type super-plasticizer(SP) and methyl cellulose(MC) viscosity agent. According to the result, as the mixing ratio of melamine type SP and MC viscosity agent increases, the bleeding is reduced due to a increase of the air content. When the mixing ratio of melamine type SP and MC viscosity agent is 1:2 and 1;3 at the water content of 165kg/$m^3$ and 175kg/$m^3$ respectively, slump and air content are satisfied and bleeding is reduced to some extent, so this is determined as the mixing ratio of AE water reducing agent for reduction of bleeding. It is prove that the developed AE water reducing agent for reduction of bleeding can reduce the amount of bleeding and prohibit the plastic shrinkage crack by slowing down the bleeding speed. Compressive strength of hardened concrete does not make any difference in comparison with plain concrete.

  • PDF

Effects of Blowing and Nucleating Agents on the Foaming Properties of Nylon 6

  • Jung-soo Kim;Sung Yeol Kim
    • Elastomers and Composites
    • /
    • 제58권2호
    • /
    • pp.65-69
    • /
    • 2023
  • To reduce the weight of the engineering plastic Nylon 6 resin, two high-temperature foaming agents, p-toluenesulfonyl semicarbazide (PTSS) and 5-phenyltetrazole (5-PT) (0-10 phr), were added and foamed without other additives. We investigated the effects of the foaming agent type and content on the foam density (g/cm3) and percent weight reduction rate of the Nylon 6 foam, and 5-PT exhibited better foaming performance than PTSS. In the case of 5-PT, the weight reduction rate was above 36% when the blowing agent content was 1.5 phr or higher, indicating that 5-PT is an effective blowing agent for reducing the Nylon 6 foam weight. Additionally, we studied the effect of the nucleating agent Talc content (0-0.4 phr) on Nylon 6 foaming, and the nucleating agent Talc considerably reduced foaming.