• Title/Summary/Keyword: Reduced scale model test

Search Result 146, Processing Time 0.029 seconds

Experimental Study on the Effect of Drilling Fluid with Different Mix Designs for Bore Hole Collapse Prevention (시추 안정액 배합설계에 따른 공벽 붕괴방지 효과에 관한 실험적 연구)

  • Yoo, Chung-Sik;Choi, Jung-Hyuk;Han, Yun-Su
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.1
    • /
    • pp.15-24
    • /
    • 2015
  • This paper presents the results of a reduced-scale physical model investigation into the effect of drilling fluid with different mix designs for bore hole collapse prevention. The bore hole collapse prevention mechanism for the bentonite based drilling fluid was first discussed together with the effect of conditioning with different additives on engineering characteristics of bentonite based drilling fluid. Reduced-scale model tests were then carried out considering field procedures for cases with a decomposed granitic soil with 20% fines and a sand with various drilling fluids with different mix designs. The results indicated that the addition of polymer to the bentonite based drilling fluid decreases the amount of drilling fluid injected, the drilling fluid infiltration thickness and increases the final depth of excavation. Also revealed is that the effect of polymer on the performance of drilling fluid is more pronounced in the decomposed granite soil with 20% fines than the sand. Practical implications of the findings from this study are discussed in great detail.

Experimental Study on Effect of Injected Drilling Fluid for Bore Hole Collapse Prevention (모형실험을 이용한 안정액 주입 시 공벽붕괴방지 효과 분석)

  • Choi, Jung-Hyuk;Yoo, Chung-Sik;Han, Yun-Su
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.4
    • /
    • pp.53-62
    • /
    • 2016
  • This paper presents the results of a reduced-scale physical model investigation into the effect of drilling fluid with different mix designs for use in offshore bore hole collapse prevention. Compare the bentonite and Attapulgite use. Reduced-scale model tests were then carried out considering field procedures for cases with decomposed granitic soil with fines and a sand with various drilling fluids with different mix designs. The results were indicated that the addition of polymer to the bentonite based drilling fluid decreases the amount of injected drilling fluid and increases the final depth of excavation. Also revealed that the effect of polymer on the performance of drilling fluid is more pronounced in the decomposed granite soil with fines than sand. Practical implications of the findings from this study are discussed in detail.

Launch Environment Test for Scale magNetospheric and Ionospheric Plasma Experiment (SNIPE) Engineering Qualification Model (초소형위성 SNIPE(Scale Magnetospheric and Ionospheric Plasma Experiment) 시제인증모델의 발사환경시험 및 분석)

  • Kim, Min-Ki;Kim, Hae-Dong;Choi, Won-Sub;Kim, Jin-Hyung;Kim, KiDuck;Kim, Ji-Seok;Cho, Dong-Hyun
    • Journal of Space Technology and Applications
    • /
    • v.1 no.3
    • /
    • pp.319-336
    • /
    • 2021
  • This paper discusses the results of launch environment tests for the engineering qualification model (EQM) of nanosatellite Scale magNetospheric and Ionospheric Plasma Experiment (SNIPE) for scientific missions and lessons learned for the design of nanosatellites. SNIPE is a group of four formation-flying 6U nanosatellites with a range of payloads for missions including space weather measurement. We developed the EQM to verify the preliminary design prior to fabricating the flight model. Launch environment test of EQM was conducted for the first time in 2019, and all failures were corrected and verified at the second test conducted in 2021. A notable point of the two tests is that the nanosatellite deployer used in the first test is different from that of the second test. The second deployer has the capability to fix the internal satellite whereas the first deployer just contains and deploys the satellite. Thus actual mechanical loads the satellite receives is reduced for the second test compared to the first test. This work compares the mechanical responses of two tests and proposes general guidelines for structural design of nanosatellites.

Effect of orientation of fracture zone on tunnel behavior during construction using model test (실내 모형실험을 통한 시공 중 파쇄대의 공간적 분포가 터널거동에 미치는 영향)

  • Cho, Yun-Gyu;Shin, Seung-Min;Chung, Eun-Mok;Choi, Jung-Hyuk;Yoo, Chung-Sik
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.189-204
    • /
    • 2015
  • This paper presents the results of reduced scale model tests on the effect of fault zone characteristics on the tunnel deformation behavior. A series of model tests were carried out on deep tunnels considering different fault zone orientations and offset distance. The tunnelling process was simulated in the model tests using compressed air technique. During the tests, the tunnel and ground deformation were mainly monitored while reducing the pressure inside the tunnel and the relationship between the pressure level and the tunnel deformation were established. The results indicate that for a given offset distance the tunnel behavior is influenced the most when the fault zone dips vertically while smallest influence occurs when the fault zone dips 45 degrees.

Design of Fire Source for Railway Vehicles and Measurement of Critical Velocity in Reduced-Scale Tunnels (축소터널 철도차량 화원 설계 및 임계속도 측정연구)

  • Park, Won-Hee;Hwang, Sun-Woo;Kim, Chang-Yong
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.59-68
    • /
    • 2020
  • In this study, the authors designed a reduced-scale railway vehicle fire, which was necessary for evaluating the fire safety of railway tunnels using a reduced model. To overcome the shortcomings of the methods used in conventional reduced-scale railway tunnel tests, the authors simulated the fire source of a railway vehicle using a methanol fire source for fire buoyancy, and a smoke cartridge for smoke visualization. Therefore, the heat release mass consumption rates of various methane trays were measured using a cone calorimeter (ISO 5660). The critical ventilation velocity in the railway tunnels was obtained using the designed fire source of the railway vehicle, which was evaluated by the measured temperature at the top of the tunnel as well as laser visualization.

Analysis on the Insertion Loss of a Noise Barrier by the Boundary Element Method (경계요소법을 이용한 방음벽의 삽입손실 해석)

  • 이우섭;정성수;황철호
    • Journal of KSNVE
    • /
    • v.10 no.3
    • /
    • pp.423-429
    • /
    • 2000
  • This paper investigates the use of boundary element method(BEM) to analyze the insertion loss of a noise barrier. To begin with the validity of the BEm for the analysis of noise barrier insertion loss in checked by both Lam's theoretical method and the measurements in the anechoic chamber for the scale-down models. Through simulation it is shown that using 2D BEM model is sufficient to the analysis for the barrier with large ratio of length to height. By using 2D BEM model the insertion loses are predicted for the real noise barriers in several cases which are the case that they are built parallel on both roadsides the one that there are multiple sound sources and the one that there is a gap between a concrete structure and a barrier plate.

  • PDF

A Investigation of Pull-out Characteristics for Screw Pile (스크류파일의 인발특성 연구)

  • Yoo, Chung-Sik;Shin, Boo-Nam
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09b
    • /
    • pp.88-95
    • /
    • 2010
  • Screw piles(Helical piles and anchors) are increasingly used to support and rehabilitate reinforced structures subjected to both tensile and compressive axial loads. This study presents a variety of detailed investigation on especially pull-out characteristics of screw piles performed to both reduced scale and numerical analysis to identify fundamental failure mechanisms and empirical optimized geometry of screw piles. It was found that the pull-out characteristics of screw piles are influenced with mainly different frequencies of compaction around soil and screw pile's pitch and followings are practical data based on empirical analysis.

  • PDF

Mechanism on suppression in vortex-induced vibration of bridge deck with long projecting slab with countermeasures

  • Zhou, Zhiyong;Yang, Ting;Ding, Quanshun;Ge, Yaojun
    • Wind and Structures
    • /
    • v.20 no.5
    • /
    • pp.643-660
    • /
    • 2015
  • The wind tunnel test of large-scale sectional model and computational fluid dynamics (CFD) are employed for the purpose of studying the aerodynamic appendices and mechanism on suppression for the vortex-induced vibration (VIV). This paper takes the HongKong-Zhuhai-Macao Bridge as an example to conduct the wind tunnel test of large-scale sectional model. The results of wind tunnel test show that it is the crash barrier that induces the vertical VIV. CFD numerical simulation results show that the distance between the curb and crash barrier is not long enough to accelerate the flow velocity between them, resulting in an approximate stagnation region forming behind those two, where the continuous vortex-shedding occurs, giving rise to the vertical VIV in the end. According to the above, 3 types of wind fairing (trapezoidal, airfoil and smaller airfoil) are proposed to accelerate the flow velocity between the crash barrier and curb in order to avoid the continuous vortex-shedding. Both of the CFD numerical simulation and the velocity field measurement show that the flow velocity of all the measuring points in case of the section with airfoil wind fairing, can be increased greatly compared to the results of original section, and the energy is reduced considerably at the natural frequency, indicating that the wind fairing do accelerate the flow velocity behind the crash barrier. Wind tunnel tests in case of the sections with three different countermeasures mentioned above are conducted and the results compared with the original section show that all the three different countermeasures can be used to control VIV to varying degrees.

A Study on the Recycling of Coal Ash as Structural Backfill materials (구조물 뒷채움재로서의 석탄회 활용에 관한 연구)

  • 여유현
    • Journal of Ocean Engineering and Technology
    • /
    • v.14 no.1
    • /
    • pp.74-79
    • /
    • 2000
  • The purpose of this paper is to recycle coal ash as structural backfill materials from electric power plants. Two million tons of coal ash are produced annually. The laboratory test was executed for the basic compatibility as substitution for structural backfill materials and the optimal mixture ratio(fly ash : bottom ash) was decided. In addition the model test was performed using medium scale earth pressure model with small size earth pressure cells model box data logger and some other apparatuses. Mixed coal ash and excellent backfill materials(coheisonless soil SW) were compared in the view of lateral earth pressure variation depending on wall displacement. The reduction of earth pressure when coal ash was used as a bockfill material was monitored comparing to that of cohesionless soil. the cost and environmental pollutants by treating coal ash can be reduced through developing the recycling technology.

  • PDF

The Smoke Propagating Distance in the Reduced-scale Model for a Subway Railroad Tunnel (축소 모형을 이용한 지하철터널에서의 연기전파거리 측정)

  • Kim, Myung-Bae;Choi, Byung-Il;Oh, Chang-Bo;Han, Yong-Shik
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.7 no.4
    • /
    • pp.295-304
    • /
    • 2005
  • The smoke propagating distances are measured in case that a fire occurs within the subway railroad tunnel. The tunnel is 800m long and the dimension of the cross-section is. Three vertical shafts exist for smoke ventilation. The experiments are performed using the 1/50 reduced-scale model. The smoke propagating distances are measured by thermocouples and by visualization for the accuracy. In order to understand the effect of a fire size and ventilation capacity of the shafts on the smoke propagating distance, 9 test scenarios are chosen. Based on the results, the smoke propagating distance is shown to be important criteria for the ventilation design of the tunnel.

  • PDF