• Title/Summary/Keyword: Rectifier efficiency

Search Result 351, Processing Time 0.027 seconds

Mass Transfer in an Adiabatic Rectifier of Ammonia-Water Absorption System

  • Kim, Byong-Joo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.8 no.2
    • /
    • pp.69-79
    • /
    • 2000
  • Falling film rectification involves simultaneous heat and mass transfer between vapor and solution film. In the present work, the adiabatic rectification process of ammonia-water vapor by the falling solution film on the vertical plate was investigated. The continuity momentum, energy and diffusion equations for the solution film and the vapor mixture were formulated in integral forms and solved numerically, The model could predict the film thickness, the pressure gradient, and the mass transfer rate. The effects of Reynolds number and ammonia concentration of solution and vapor mixture, rectifier length, and the enhancement of mass transfer coefficient in each phases were investigated. The stripping of water in vapor mixture occurred near the entrance of ammonia solution, which imposed the proper size of an adiabatic rectifier. Rectifier efficiency increased as film Reynolds number increased and as vapor mixture Reynolds number decreased. The improvement of rectifier efficiency was significant with the enhancement of mass transfer coefficient in falling film.

  • PDF

A study on the efficiency characteristics for LLC resonant half-bridge converter with synchronous rectifier (동기정류기를 적용한 공진형 하프브릿지의 효율특성에 관한연구)

  • Lee, Gwang-Taek;Ahn, Tae-Young
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.289-291
    • /
    • 2005
  • In this paper results of the experiment which used LLC resonant half bridge DC-DC converter to a portable electrical equipment. LLC resonance Half Bridge DC-DC converter which was used in this experiment improved an efficiency because it reduced switching, conduction losses and with synchronous rectifier. As a result of the experiment, this proposed converter could verified an increase of 2% to the efficiency more than diode rectifier.

  • PDF

A Piezoelectric Energy Harvester with High Efficiency and Low Circuit Complexity

  • Do, Xuan-Dien;Nguyen, Huy-Hieu;Han, Seok-Kyun;Ha, Dong Sam;Lee, Sang-Gug
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.3
    • /
    • pp.319-325
    • /
    • 2015
  • This paper presents an efficient vibration energy harvester with a piezoelectric (PE) cantilever. The proposed PE energy harvester increases the efficiency through minimization of hardware complexity and hence reduction of power dissipation of the circuit. Two key features of the proposed energy harvester are (i) incorporation synchronized switches with a simple control circuit, and (ii) a feed-forward buck converter with a simple control circuit. The chip was fabricated in $0.18{\mu}m$ CMOS processing technology, and the measured results indicate that the proposed rectifier achieves the efficiency of 77%. The core area of the chip is 0.2 mm2.

Optimal Design Methodology of Zero-Voltage-Switching Full-Bridge Pulse Width Modulated Converter for Server Power Supplies Based on Self-driven Synchronous Rectifier Performance

  • Cetin, Sevilay
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.121-132
    • /
    • 2016
  • In this paper, high-efficiency design methodology of a zero-voltage-switching full-bridge (ZVS-FB) pulse width modulation (PWM) converter for server-computer power supply is discussed based on self-driven synchronous rectifier (SR) performance. The design approach focuses on rectifier conduction loss on the secondary side because of high output current application. Various-number parallel-connected SRs are evaluated to reduce high conduction loss. For this approach, the reliability of gate control signals produced from a self-driver is analyzed in detail to determine whether the converter achieves high efficiency. A laboratory prototype that operates at 80 kHz and rated 1 kW/12 V is built for various-number parallel combination of SRs to verify the proposed theoretical analysis and evaluations. Measurement results show that the best efficiency of the converter is 95.16%.

A Study on Technical Trends in Telecom Rectifier Plant (통신용 정류시설의 기술적 동향에 관한 연구)

  • 김만고
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.3
    • /
    • pp.278-283
    • /
    • 1997
  • The rectifier is the main element in the telecom DC power system. This paper investigates the advantages and disadvantages of three rectifier techniques ; thyristor, ferro - resonant, and switched - mode. Compared with other techniques, the switched - mode rectifier tech¬nique offers several advantages such as higher efficiency, smaller size and weight, and lower audible noise. Technical requirements in telecom rectifier plant are also described. Finally, the future trends in telecom powering are discussed in connection with the advance oftelecom net¬works.

  • PDF

High Efficiency Half-bridge DC-DC Converter for an LED Backlight Drive System of LCD Module Inspection Equipment (LCD 모듈 검사장비용 LED 백라이트 드라이브 시스템을 위한 고효율 반브리지 직류-직류 전력변환기)

  • Yoo, Doo-Hee;Jeong, Gang-Youl
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.6
    • /
    • pp.535-542
    • /
    • 2008
  • This paper presents a high efficiency half-bridge DC-DC converter for an LED backlight drive system of LCD module inspection equipment. The proposed converter improves the converter efficiency using characteristics of the asymmetrical half-bridge converter and the self-driven synchronous rectifier, and thus improves the total efficiency of the LED backlight drive system. The synchronous rectifier applied to the proposed converter is the new topological synchronous rectifier, which changes slightly the transformer structure and the synchronous switch connection in the asymmetrical half-bridge converter with a conventional self-driven synchronous rectifier. Since the proposed converter utilizes the transformer leakage inductor as its resonant inductor, its structure is simplified. The proposed converter well operates under the universal DC input voltage ($250{\sim}380V$). The operational principle and a design example for a 100W prototype are discussed in detail, respectively. Experimental results are shown for the designed prototype converter under universal DC input voltage.

High-Efficiency Full-Bridge DC-DC Converter with Current-Doubler Rectifier with Asymmetric Pulse-Width Modulation (비대칭 펄스 폭 변조 방식의 배전류 정류기 회로를 적용한 고효율 풀-브릿지 DC-DC 컨버터)

  • Yang, Min-Kwon;Choi, Woo-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.3
    • /
    • pp.280-289
    • /
    • 2015
  • A high-efficiency full-bridge DC-DC converter with a current-doubler rectifier and an asymmetric pulse-width modulation is proposed. Through the asymmetric pulse-width modulation, the proposed converter achieves zero-voltage switching of power switches without the circulating currents. The proposed converter reduces the output current ripple through the current-doubler rectifier. A control strategy is suggested for the proposed converter to charge battery banks. A constant current and constant voltage charging is performed. The proposed converter achieved a higher efficiency compared with the conventional full-bridge DC-DC converter with a phase-shift modulation. The performance of the proposed converter is evaluated by the experimental results for a 1.0 kW prototype circuit.

A Study on Efficiency and Characteristic of Zero Voltage Switched Half-Bridge Converter and Forward Converter (영전압 스위칭 하프브리지 컨버터와 포워드 컨버터의 효율 및 특성에 관한 연구)

  • Seo, J.K.;Kim, Y.;Baek, S.H.;Kwon, S.D.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.147-149
    • /
    • 1998
  • In this paper, zero voltage switched half bridge converter and an active-clamped, zero voltage switched forward converter equipped with self-driven synchronous rectifier is designed and investigated for high efficiency BC-DC converter. A synchronous rectifier is has a lower conduction power loss than shottky diode rectifier. The purpose of this paper is to investigate the effect of parasitic inductance in a synchronous rectifier of DC-DC converters and examine overall efficiency of zero voltage switched DC-DC converters.

  • PDF

Tolerance Control for the Inner Open-Switch Faults of a T-Type Three-Level Rectifier

  • Lee, June-Seok;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1157-1165
    • /
    • 2014
  • The T-type topology is a three-level topology that has an advantage in terms of its number of switching device and its efficiency when compared to the neutral-point clamped (NPC)-type topology. With the recent increase in the usage of the T-type topology, the interest in its reliability has also increased. Therefore, a tolerance control for a T-type rectifier is necessary to improve the reliability of applications when an open-switch fault occurs. NPC-type rectifiers cannot eliminate input current distortion completely. However, the T-type rectifier is able to restore distorted current. In this paper, a tolerance control for the $S_{x2}$ and $S_{x3}$ open-switch faults of a T-type rectifier is proposed where it is advantageous in terms of efficiency when compared with other tolerance controls. The performance of the proposed tolerance control is verified through simulation and experimental results.

LLC resonant half-bridge DC-DC converter with synchronous rectifier (동기정류기를 적용한 LLC 공진형 하프브릿지 DC-DC 컨버터)

  • Lee, Gwang-Taek;Ahn, Tae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1392-1394
    • /
    • 2005
  • In this paper results of the experiment which used LLC resonant Half Bridge DC-DC converter to a portable electrical equipment. LLC resonant Half Bridge DC-DC converter which was used in this experiment improved an efficiency because it reduced switching, conduction losses and with synchronous rectifier. As a result of the experiment, this proposed converter could verified an increase of 2% to the efficiency more than diode rectifier.

  • PDF