Electrostatic Microactuators operated at low drive voltages Using Triangular Tip (삼각 팁을 이용한 저전압 구동형 정전방식 마이크로액추에이터)

  • Kim, Bong-Hwan;Seong, U-Gyeong;Jeon, Guk-Jin
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.9
    • /
    • pp.605-610
    • /
    • 2001
  • Electrostatic comb-drive microactuators with sub-micron gap were fabricated and tested. We designed and fabricated two type of electrodes which are rectangular and triangular tip. The fabricated microactuators with triangular tip resulted in the electrode gaps in the range of 0.55 ${\mu}{\textrm}{m}$~1.35 ${\mu}{\textrm}{m}$ Displacement of 1 ${\mu}{\textrm}{m}$ and electrostatic force of 2.3 $\mu$N were observed in a triangular-tip microactuator with 0.55 ${\mu}{\textrm}{m}$ gap when a DC drive voltage of 13 volts was applied. Measured 1st resonance frequency of microactuators was about 23 kHz.

  • PDF

The Electrical and Optical Properties of Xe Flat Plasma Light Source (제논 (Xe) 평판형 플라즈마 광원의 전기적 및 광학적 특성 연구)

  • Choi, Yong-Sung;Moon, Jong-Dae;Lee, Kyung-Sup;Lee, Sang-Heon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.86-90
    • /
    • 2006
  • Discharge of the flat lamp lighting source research are requested very much. For improving brightness, life time, efficiency of flat lamp, plasma diagnosis of the f1at lamp lighting source to understand property of lighting source is very important. Distance of discharge electrode is 5.5mm and width is 16.5mm, we have measured electron temperature and electron density measured with single Langmuir probe in flat lamp. We have tested the discharge from 100 Torr to 300 Torr pressure. The pulse is rectangular pulse with frequency 20kHz and duty ratio 20%. In result, electron temperature decreases and electron density increase as increase the gas pressure and electron temperature decreases and electron density increase as increase the voltage.

  • PDF

Transparent Rectangular Patch Antenna Using Square Metal Mesh Transparent Electrode (정방형 메탈메쉬 투명전극을 이용한 투명 사각 패치 안테나)

  • Kang, Seok Hyon;Jung, Chang Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.4
    • /
    • pp.277-284
    • /
    • 2018
  • This paper reports the transparent electrode, which would be applied to transparent displays and smart glasses. Herein, a squared metal mesh with the most widely used copper wire in microwaves is studied for the alternating thin-film-type transparent and conducting indium tin oxide(ITO), with a low conductivity(sheet resistance > $5{\Omega}/sq.$). The electromagnetic performance of a patch antenna with metal mesh is analyzed. This paper presents the results of the optical(OT, optical transparent) and electrical(sheet resistance) characteristics of a squared metal mesh, which is a basic design. To improve the OT, copper wire(w=0.2 mm) is used in fabricating the squared metal mesh and the relationship between the OT and the antenna performance(radiation gain, radiation pattern) was analyzed according to the mesh size(l=1, 2 mm). The measurement results show that the antenna performance and the optical characteristic are in inverse proportion to each other. In real applications, the optical and electrical characteristics, and the costs of production are to be considered.

Fabrication of Combined Probes for Interstitial hyperthermia and Brachyradiotherapy (고 선량율 근접 및 온열치료 병용 삽입관의 제작과 특성)

  • Chu, Sung-Sil;Kim, Sung-Kyu
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.85-87
    • /
    • 2004
  • We fabricated flexible thermoradiotherapy probes to alternated combination with Interstitial hyperthermia and Brachyradiotherapy thermoradiotherapy probe was coated by gold plate on polyethylene brachytherapy probe. When Agar phantom was heated 15 minute with 30 W radiofrequency power, temperature increased as 5oC for polyethylene probe and 20oC for gold coated polyethylene probe. We observed that the 1 cm square array would heat a volume with a 1.25 cm radius circular field cross section to therapeutic temperatures (90% relative SAR using Tm) and the 2 cm square array with a 1.75 cm radius rectangular field with central inhomogeneity. With 2 cm long electrode implants, we observed that the 1 cm square array would heat a 3 cm long sagittal section to therapeutic temperature (90% relative SAR using Tm). The histopathological changes associated with RF heating of normal canine brains have been correlated with thermal distributions. RF needle electrode heating was applied for 50 min to generate tissue temperatures of 43${\circ}$C. We obtained a quarter of the heated tissue material immediately after heating and sacrificed at intervals from 7${\sim}$30 days. The acute stage was demonstrated by liquefactive necrosis, pyknosis of neuronal element in the gray matter. Mild gliosis occurring around the necrosis was demonstrated in the last sacrificed (days30)canine brain.

  • PDF

Characteristics of Mo Thin Films Deposited by DC Magnetron Sputtering (DC 마그네트론 스퍼터링 방법에 의해 증착된 Mo 박막의 특성)

  • Kong, Seon-Mi;Xiao, Yubin;Kim, Eun-Ho;Chung, Chee-Won
    • Korean Chemical Engineering Research
    • /
    • v.49 no.2
    • /
    • pp.195-199
    • /
    • 2011
  • Mo thin films were deposited on soda lime glass at room temperature by using DC magnetron sputtering The electrical and structural properties of the films were investigated by varying DC power and gas pressure as the deposition parameter. As DC power increased, the deposition rate of Mo films was increased and the electrical resistivity was decreased. It was observable that the crystallinity of the films was improved with increasing DC power. As gas pressure decreased, the deposition rate and resistivity of the films were decreased, and long rectangular grains were densely formed. With increasing gas pressure, the grains were transformed to a round shape and the voids on the film surface were increased. It was confirmed that the electrical resistivity of Mo films was increased as the amount of oxygen combined with Mo atoms increased. It was also disclosed that the films have low resistivity as the degree of coupling of oxygen with Mo was reduced due to the enhancement of the crystallinity of the films.

Fuel Cell End Plates: A review

  • Kim, Ji-Seok;Park, Jeong-Bin;Kim, Yun-Mi;Ahn, Sung-Hoon;Sun, Hee-Young;Kim, Kyung-Hoon;Song, Tae-Won
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.1
    • /
    • pp.39-46
    • /
    • 2008
  • The end plates of fuel cell assemblies are used to fasten the inner stacks, reduce the contact pressure, and provide a seal between Membrane-Electrode Assemblies (MEAs). They therefore require sufficient mechanical strength to withstand the tightening pressure, light weight to obtain high energy densities, and stable chemical/electrochemical properties, as well as provide electrical insulation. The design criteria for end plates can be divided into three parts: the material, connecting method, and shape. In the past, end plates were made from metals such as aluminum, titanium, and stainless steel alloys, but due to corrosion problems, thermal losses, and their excessive weight, alternative materials such as plastics have been considered. Composite materials consisting of combinations of two or more materials have also been proposed for end plates to enhance their mechanical strength. Tie-rods have been traditionally used to connect end plates, but since the number of connecting parts has increased, resulting in assembly difficulties, new types of connectors have been contemplated. Ideas such as adding reinforcement or flat plates, or using bands or boxes to replace tie-rods have been proposed. Typical end plates are rectangular or cylindrical solid plates. To minimize the weight and provide a uniform pressure distribution, new concepts such as ribbed-, bomb-, or bow-shaped plates have been considered. Even though end plates were not an issue in fuel cell system designs in the past, they now provide a great challenge for designers. Changes in the materials, connecting methods, and shapes of an end plate allow us to achieve lighter, stronger end plates, resulting in more efficient fuel cell systems.

Effects of Modulation Type on Electrically-Elicited Tactile Sensation (전기자극 변조방식이 체성감각에 미치는 영향)

  • Hwang, Sun-Hee;Ara, Jawshan;Song, Tong-Jin;Bae, Tae-Sue;Park, Sang-Hyuk;Khang, Gon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.7
    • /
    • pp.711-716
    • /
    • 2012
  • The purpose of this study was to investigate how the modulation method affects the effectiveness of eliciting tactile sensations by electrical stimulation. Two methods were employed and the results were compared and analyzed; pulse amplitude modulation (PAM) and pulse width modulation (PWM). Thirty-five healthy subjects participated in the experiments to measure the stimulation intensity that began to elicit a tactile sensation - activation threshold (AT). Constant-current monophasic rectangular pulse trains were employed, and the stimulation intensity was varied from zero until the subject felt any uncomfortable sensation. The step size of the stimulation intensity was 100nC/pulse. After each experiment, the subject described the sensation both quantitatively and qualitatively. The two modulation methods did not make a significant difference as far as the AT values were concerned, but most of the subjects showed 'intra-individual' consistency. Also, it was confirmed that our range of the stimulation parameters enabled us to obtain three major tactile sensations; tickling, pressure and vibration. The results suggested that the stimulation parameters and the modulation type should be selected for each individual and that selective electrical stimulation of the mechanoreceptors needs more diversified researches on the electrode design, multi-channel stimulation protocol, waveforms of the pulse train, etc.

Silicon Nitride Layer Deposited at Low Temperature for Multicrystalline Solar Cell Application

  • Karunagaran, B.;Yoo, J.S.;Kim, D.Y.;Kim, Kyung-Hae;Dhungel, S.K.;Mangalaraj, D.;Yi, Jun-Sin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.276-279
    • /
    • 2004
  • Plasma enhanced chemical vapor deposition (PECVD) of silicon nitride (SiN) is a proven technique for obtaining layers that meet the needs of surface passivation and anti-reflection coating. In addition, the deposition process appears to provoke bulk passivation as well due to diffusion of atomic hydrogen. This bulk passivation is an important advantage of PECVD deposition when compared to the conventional CVD techniques. A further advantage of PECVD is that the process takes place at a relatively low temperature of 300t, keeping the total thermal budget of the cell processing to a minimum. In this work SiN deposition was performed using a horizontal PECVD reactor system consisting of a long horizontal quartz tube that was radiantly heated. Special and long rectangular graphite plates served as both the electrodes to establish the plasma and holders of the wafers. The electrode configuration was designed to provide a uniform plasma environment for each wafer and to ensure the film uniformity. These horizontally oriented graphite electrodes were stacked parallel to one another, side by side, with alternating plates serving as power and ground electrodes for the RF power supply. The plasma was formed in the space between each pair of plates. Also this paper deals with the fabrication of multicrystalline silicon solar cells with PECVD SiN layers combined with high-throughput screen printing and RTP firing. Using this sequence we were able to obtain solar cells with an efficiency of 14% for polished multi crystalline Si wafers of size 125 m square.

  • PDF

EFFECT OF LOW - POWER LASER IRRADIATION ON PAIN RESPONSE (저출력 레이저조사가 동통반응에 미치는 영향)

  • Kim, Sung-Kyo;Yoon, Soo-Han;Lee, Jong-Heun
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.2
    • /
    • pp.85-98
    • /
    • 1991
  • The aim of this study was to investigate the effect of low - power laser used in the medical field for various purposes to suppress pain responses evoked by noxious electrical or mechanical stimuli. After both inferior alveolar nerves and the left anterior digastric muscle of cats under general anesthesia were exposed, a recording electrode for the jaw opening reflex was inserted into the anterior digastric muscle. The right inferior alveolar nerve was dissected under a surgical microscope until the response of the functional single nerve could be evoked by the electrical stimulation of the dental pulp or oral mucosa. The electrical stimulus was applied with a rectangular pulse of 10 ms duration for measuring the threshold intensity of a single nerve fiber in the inferior alveolar nerve which responds to stimulation of dental pulp and oral mucosa. Then a pulse of 1 ms duration was applied for determination of conduction velocity. A noxious mechanical stimulus to the oral mucosa was applied by clamping the receptive field with an arterial clamp. The Ga-As diodide laser(wave length, 904 nm ; frequency, 1,000 Hz) was irradiated to the prepared tooth cavity, inferior alveolar nerve and oral mucosa as a pulse wave of 2 mW for 6 minutes. This was followed by a continuous wave of 15 mW for 3 minutes. The action potential of the nerve and EMG of the digastric muscle evoked by the noxious electrical stimulus and nerve response to noxious mechanical stimulus were compared at intervals of before, immediately after, and at 5, 10, 20, 40, 60 minutes after laser irradiation. The results were as follows: The conduction velocity of the intrapulpal $A{\delta}$- nerve fiber recorded from the inferior alveolar nerve before irradiation had a mean value of $6.68{\pm}2.07m/sec$. The laser irradiation did not affect the conduction velocity of the AS - nerve fiber and did not change the threshold intensity or amplitude of the action potential either. The EMG of the digastric muscle evoked by noxious electrical stimulation to the tooth was not changed by the laser irradiation, whether in latency, threshold intensity or amplitude. The laser irradiated to the receptive field of the oral mucosa which was subjected to noxious stimuli did not affect the amplitude of the action potential or the frequency either.