• Title/Summary/Keyword: Recording devices

Search Result 157, Processing Time 0.021 seconds

A Survey of Utilizing Status and Demand for Medical Devices in Traditional Korean Medicine (한방의료기기 사용 현황 및 개발 수요에 대한 조사 연구)

  • Nam, Dong-Hyun
    • The Journal of Korean Medicine
    • /
    • v.34 no.1
    • /
    • pp.69-79
    • /
    • 2013
  • Objectives: The aim of this survey was to investigate utilization, intended use, problems with and demand for medical devices by surveying members of the traditional Korean medical society. Methods: We distributed questionnaires to 13,957 traditional Korean medical doctors via e-mail, and received replies from 1,225. The questionnaire consisted of 4 multiple-choice questions for survey respondent information, 8 multiple-choice questions about the status of medical devices utilizing, and a short answer question about the demand for medical devices. Results: Use of medical devices in traditional Korean medical clinics is common. Diagnostic medical devices are mainly used to assess the patient's condition and to establish a close rapport with clients. In case of therapeutic medical devices, they are usually used for secondary treatment. Issues with traditional Korean medical devices currently in use were ineligibility for national health insurance, low reliability, uncertain validity, and high price. In development of traditional Korean medical equipment, the need for diagnostic medical devices was greater than for therapeutic, and the need for the recording and analysis of medical image data and visualization of medical information was great. Conclusions: There is growing demand for facilitating the development and commercialization of traditional Korean medical devices. To satisfy this demand, research on evaluation indicators that reflect functional and structural clinical information and how to clinically assess the indicators should proceed.

A Method of Deriving UAS Flight Recording System Parameters for Aviation Accident and Incident Investigation (항공사고 및 준사고 조사를 위한 UAS 비행 기록 시스템 파라미터 도출 방안)

  • Keon-hee Lee;Joong-yoon Lee
    • Journal of Advanced Navigation Technology
    • /
    • v.28 no.1
    • /
    • pp.77-86
    • /
    • 2024
  • 'UAS flight recording system' is a system that is mounted on an unmanned aircraft system consisting of various components and records flight-related data. The data recorded by this system should be used for aviation accident and incident investigations to prevent similar accidents. In particular, for the category of UAS with high operating risk, safety devices close to that of manned aircraft are required, and it is urgent to develop flight recording systems reflecting the characteristics of the UAS to secure airworthiness. This paper highlights the need for UAS flight recording systems for aviation accident and incident investigations and seek a method to derive flight recording system parameters for 'Certified Category' with high operational risk. To this end, Inter-City UAM was used as a concrete use case, and the process of approaching system parameters was devised by assuming accident occurrences and hazards from mission profiles and scenarios. As a result of the study, it was confirmed that parameters could be derived through this process.

The Interfacial Segregation of Elemental Ag in the Sputter-Deposited AgInSbTe Thin Films (스퍼터 증착시킨 AgInSbTe 박막에서 Ag의 계면편석)

  • Choi, Woo-S.;Kim, Myong-R.;Seo, Hun;Park, Jeong-W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.15-18
    • /
    • 1996
  • The elemental segregation in the sputter-deposited AgInSbTe recording thin films was studied by means of Auger electron spectroscopy and ESCA for the specimens of as-deposited and as heat-treated conditions. Auger electron spectroscopy and ESCA revealed an extremely thin layer of elemental inhomogeneity, especially for the silver, even in as-deposited condition. The chemical analysis results obtained in this alloy system are discussed in terms of process parameters and target microstructure.

  • PDF

Formation of Microporosities in Sputter-Deposited AgInSbTe Thin Films and Their Behavior (스퍼터 증착시킨 AgInSbTe 박막에서 미세기공의 형성과 그 거동)

  • Kim, Myong-R.;Seo, H.;Park, J. W.;Choi, W. S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.84-89
    • /
    • 1996
  • The nucleation and growth of microporosities was observed during the course of annealing treatment of sputter-deposited AgInSbTe thin films. There was a close correlation between the density of microporosity and the sputtering gas pressure in annealed thin films. The void density for a given composition decreased with sputtering gas pressure. It was shown from the present study that the number of porosities decreased while the average porosity size increased as the annealing temperature and holding time increased. The mechanism of porosity formation in the sputter-deposited AgInSbTe thin flus containing Ar-impurity trapped from the Ar-plasma is discussed in the present article.

  • PDF

Detection of Arrhythmias by Holter Monitoring and Use of Wearable Electrocardiography Devices Holter and wearable devices for arrhythmia detection

  • Ji Yeon Chang;Jae Kyung Kim
    • International Journal of Advanced Culture Technology
    • /
    • v.11 no.2
    • /
    • pp.310-314
    • /
    • 2023
  • In this paper, we show that the limitations of Holter monitoring and Wearable Electrocardiogarphy Devices and their arrhythmia detection. Sudden death caused by cardiovascular disease, often referred to as the "silent killer" due to its unpredictable nature, is a major health concern. Electrocardiography (ECG) is a basic diagnostic tool for detecting heart disease, but its limitations make it difficult to detect arrhythmia, a significant indicator of an irregular heart state. To address this limitation, a long-term continuous ECG recording device has been developed, Holter ECG device and wearable device. A significant number of studies have focused on the differences between Holter monitoring and wearable devices. The Holter tests were useful for detecting regularly occurring arrhythmias, whereas wearable patches were better at detecting random and infrequent arrhythmias. Wearable patches were effective in detecting episodes of arrhythmia and myocardial ischemia. Despite the concern, wearable devices had less signal loss than Holter monitoring and patients also preferred wearable devices over Holter monitoring due to convenience. These results could mean that the wearable devices can perfectly replace the Holter test.

A Modified PRML for Reduction of Nonlinear Distortion in Digital High-Density Recording Channels (디지탈 고밀도 기록 채널의 비선형 왜곡 감소를 고려한 PRML)

  • Son, Joo-Sin;Seo, Kwang-Lak;Cho, Yong-Soo;Lim, Yong-Hoon;Youn, Dae-Hee
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.11
    • /
    • pp.27-35
    • /
    • 1994
  • In this paper, a modified version of PRML is discussed to reduce nonlinearity in digital high-density storage devices. We propose a PRML with a nonlinear compensator which can reduce nonlinear interaction between the stored flux regions on the storage channel, and apply it to recording channels with three different densities. By comparing its performance with the existing PRML through computer simulation, we confirm that the nonlinear intersymbol interference increasing with high-density recording channels can be reduced effectively by the PRML with a nonlinear compensator.

  • PDF

Data-centric Smart Street Light Monitoring and Visualization Platform for Campus Management

  • Somrudee Deepaisarn;Paphana Yiwsiw;Chanon Tantiwattanapaibul;Suphachok Buaruk;Virach Sornlertlamvanich
    • Journal of information and communication convergence engineering
    • /
    • v.21 no.3
    • /
    • pp.216-224
    • /
    • 2023
  • Smart lighting systems have become increasingly popular in several public sectors because of trends toward urbanization and intelligent technologies. In this study, we designed and implemented a web application platform to explore and monitor data acquired from lighting devices at Thammasat University (Rangsit Campus, Thailand). The platform provides a convenient interface for administrative and operative staff to monitor, control, and collect data from sensors installed on campus in real time for creating geographically specific big data. Platform development focuses on both back- and front-end applications to allow a seamless process for recording and displaying data from interconnected devices. Responsible persons can interact with devices and acquire data effortlessly, minimizing workforce and human error. The collected data were analyzed using an exploratory data analysis process. Missing data behavior caused by system outages was also investigated.

Optical Performance Evaluation of SIL Assembly with Lateral Shearing Interferometer (층 밀리 간섭계를 이용한 고체침지렌즈의 광학적 성능 평가)

  • Lee, Jin-Eui;Kim, Wan-Chin;Choi, Hyun;Kim, Tae-Seob;Yoon, Yong-Joong;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.4
    • /
    • pp.224-229
    • /
    • 2006
  • There has been studied flow to minimize the spot size to increase data capacity. Optical data storage devices are being developed near practical limits with wavelength and NA of 405nm and 0.85. There has been studied many types of next generation storage devices such as blu-ray multilayer system, probe based data storage and holographic data storage. Among these data storage devices, solid immersion lens(SIL) based near field recording (NFR) has been widely studied. In this system, SIL is the key component that focuses the laser beam with a very small size which enables ultra high data capacity. Therefore, optical performance evaluation system is required for SIL assembly. In this dissertation, a simple and accurate SIL assembly measurement method is proposed with wedge plate lateral shearing interferometer(LSI). Wedge plate LSI is cheaper than commercialized interferometer, robust to the vibration and the moving distance for phase shifting is large that is order of micrometer. We designed the thickness, wedge angle, material, surface quality and wavelength of wedge plate as 1mm, 0.02degree, fused silica, lamda/10(10-5) and 405nm, respectively. Also, we confirmed simulation and experimental results with quantitative analysis. This simple wedge plate LSI can be applied to different types of SIL such as solid immersion mirror(SIM), hemispherical, super-hemispherical and elliptical SIL.

  • PDF

Study on wear characteristics of commercialized HDD slider pad (상용 하드디스크 슬라이더 패드의 마모 특성에 관한 연구)

  • Jang, Cheol-Eun;Kim, Dae-Eun
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.3
    • /
    • pp.139-143
    • /
    • 2007
  • In recent years new recording media and materials for head-disk interface (HDI) have been developed in order to increase the recording density of storage devices and decrease the cost of production. It is well known that HDI in hard disk drive (HDD) needs high durability and stability. The tribological characteristic of commercialized HDI systems is an important indicator of the HDD reliability. In this study, experimental investigation on the wear coefficient of commercialized hard disk slider pads was performed. The slider was placed on top of a hard disk and allowed to slide for a set distance. The wear of the pads was measured after the sliding tests. The result showed that the micro-bumps in commercialized HDD have extremely low wear coefficient of $10^{-11}$. The results of this work may be used for further development of the HDI technology for HDD.

  • PDF