• Title/Summary/Keyword: Recorder

Search Result 517, Processing Time 0.032 seconds

Study on Production of Power Monitoring Unit for Electric Propulsion UAV (전기동력 무인항공기용 PMU의 개선 및 제작에 대한 연구)

  • Kang, Jin-Myeong;Jeong, Jin-Seok;Kang, Beom-Soo;Kim, Jang-Mok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.2
    • /
    • pp.140-147
    • /
    • 2017
  • This paper describes the design and implementation of previously developed PMU (Power Monitoring Unit) for LiPB (Lithium-ion Polymer Battery) that is electric propulsion used as unmanned aerial vehicle's power source. Improved PMU provides stable voltage and current to various sensors and elctric motors necessary during flight. Voltage and current monitoring function that is measured by improved PMU more precisely be enhanced and the monitoring channel and temperature sensor is added. To verify the improved performance of the equipment, it is integrated to electric propulsion system of unmanned aerial vehicle. PMU is calibrated through the ground test. And PMU's performance is checked through the flight test.

Performance evaluation according to the forming method during production of bellows for LNG carriers II - Comparison of low cycle fatigue characteristics - (LNG 선박용 벨로우즈의 제작시 성형방법에 따른 성능 평가 II - 저주기 피로 특성 비교 -)

  • Kim, Pyung-Su;Kim, Jong-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.593-598
    • /
    • 2016
  • Static tests and low-cycle fatigue tests were conducted to analyze the characteristics of the bellows for LNG vessels according to the forming methods. The cycle life of bellows was tested based on the specified cyclic life, 80000 cycles, to analyze the difference in characteristics between pre-and post-test data by measuring the strain and stress of each convolution of formed bellows. The low-cycle fatigue test was conducted using a strain gauge that was attached to the convolution of bellows. Formed bellows were placed on the structural test device which was equipped with a hydraulic system and was capable of moving in the x-y direction. Data was measured and processed by a multi recorder. Through the static test and low-cycle fatigue tests results, the difference between the cycle life of bellows formed by mechanical methods and of those formed by hydraulic methods was investigated. Moreover, the cause of difference in cyclic life according to forming methods was performed.

A Study on the Implementation of Real-time Digital Filter System for the Baseline Wandering Elimination (기저선 변동 제거를 위한 실시간 디지털 필터 시스템 구현에 관한 연구)

  • 윤승구;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.512-515
    • /
    • 2001
  • The heifer electrocardiograph is a widely progressing research which is used in judgement to existence for a heart disease and analyzes electric potential changes of heart movement during continuous living of everyday after attaching to body portable holler recorder for twenty-four hours. In order to obtain electrocardiogram clearly, it must eliminate that 60Hz power line interference, baseline wandering, noise of muscle constriction. In holter electrocardiogram, the most big problem which is recorded signal of ECG(electrocardiogram) is a baseline wandering elimination, which is occurred by rhythm of respiration and muscle constriction of part from attaching to an electrode. Such baseline is roughly irregular wandering and shaking up and down therefore the part of baseline wandering elimination is very important because it is difficult of ECG diagnosis. In this study, it is stabilized baseline wandering in analog part as implementation f real-time signal processing digital filter so it is applicable to analyze patient's heart disease by way of design of baseline wandering elimination system.

  • PDF

Propagation of Crack in Concrete Subjected to Dynamic Loading (동적하중(動的荷重)을 받는 콘크리트의 구열(龜裂)성장)

  • Kang, Sung Hoo;Kim, Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.135-145
    • /
    • 1988
  • This study deals with the prediction of crack propagation in concrete mortar subjected to static and dynamic load. Total 54 CLWL-DCB(Crack-line-loaded-double-cantilever beam) concrete mortar specimens were tested to measure crack growth using ASTM 561-80. Main variables were sand to cement ratio and water to cement ratio. The resulting load(P)-COD(Crack Opening Displacement; $2V_1$) curves and COD-CTOD (Crack Tip Opening Displacement; $2V_2$) curves were analyzed to calculate effective crack length and physical crack length by way of ASTM 561-80 proposed. Replica crack length were also obtained directly during the test. The differences in crack propagation between under static load and under dynamic load were investigated.

  • PDF

UNDERWATER NOISE GENERATED BY FISHING GEAR -Stern trawl net- (어구에서 발생되는 소음 -트로올 어구-)

  • YOON Gab Dong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.12 no.4
    • /
    • pp.217-224
    • /
    • 1979
  • The main purpose of the present study is to measure the sound spectra of the underwater noises generated by moving trawl net. An underwater recording system was designed to detect underwater noise generated by moving trawl net. The acoustic analysis was made by a heterodyne analyzer (B & K 2010) and level recorder (B & K 2307). The noises generated by the trawl net are appreciably higher (about 10dB) than the background noise in the presence of the fishing vessel. The frequency distribution of underwater noise was DC-6,300 Hz and predominant frequency range was 100-200 Hz, and maximum sound pressure level was $137\;db(re\;1{\mu}Pa)$. Sound pressure level recorded at the ground rope was higher than that recorded at the head rope. The sound pressure level meosured in the course of hawling was higher than that measured in the course of towing. When tile net is being casted tile sound pressure level showed the lowest value.

  • PDF

DEVELOPMENT of CONTINUOUS GRAIN DRYER

  • Kim, Y.H.;Cho, Y.K.;Cho, K.H.;Keum, D.H.;Han, C.S.;Han, J.K.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.396-404
    • /
    • 2000
  • Post harvest processes for rice include drying, storage and processing. Drying has a great effect on the quality of the grain. The existing rice centers are with the ill equipped, especially with drying and storage facilities. The rice harvesting has bully mechanized, a large volume of rice with high moisture content are taken to the rice processing complex(RPC). Three, the need for drying and storage facilities becomes more urgent. At present the daily drying capacity of RPC can't exceed over 40~50 M/T. Therefore new technology and facilities for a high quality and main efficient drying should be introduced one such technology is the continuous flow drying system. This research, aims to test performance efficiency the mixed continuous flow grain dryer was whose daily drying capacity is 100 M/T. The results of the performance tests of the dryer are shown as follows; (1) The temperature distribution of the drying modules were measured by a temperature recorder. The fifth module showed the highest value, followed by the seventh and the third. (2) When the intake air temperature was $55^{circ}C$, the drying rates were 1.7 and 2.6%, wb/pass in the exhaust temperatures of 20 and $22^{circ}C$. And when the intake air temperature was $60^{circ}C$, the drying rates were 1.7 and 2.3%, wb/pass in the exhaust temperatures of 22 and $25^{circ}C$. (3) The average increased rate of cracked grains after the drying process was 0.7% which is below the tolerance limit (2.0%) of the continuous grain dryer.

  • PDF

Development of a 12 Channel Interpretive Electrocardiograph (12채널 해석 심전계 시제품 개발)

  • Lee, Byung-Chae;Hahm, Geon;Jun, Young-Il;Choi, Kwang-Chol;Choi, Keun-Ho;Kim, Won-Ky;Kim, Jun-Soo;Jeong, Ki-Sam;Lee, Jeong-Whan;Lee, Myoung-Ho;Wright, George;Cochlan, David
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.411-414
    • /
    • 1997
  • This paper describes the design guideline, methodology and general specification of the developed 12 channel interpretive electrocardiograph. The developed 12 channel electrocardiograph consists of main module, patient module, DSP module, interface module, power/battery module, TFT color LCD and thermal recorder. The control panel of the system has full keyboard, rotate/push button, function key and unctional indicators. The graphic user interface program conveniently allows user to record, setup, store, manage ECGs. A variety of system configurations give it ability to make user favorable environment. This system also has a resting adult's ECG analysis program. The developed system and program will be continusely evolved using a database of clinically correlated ECGs.

  • PDF

A Study on the Transducer Calibration for Acoustic Emission Measurement (AE 측정을 위한 탐촉자의 보정에 대한 고찰)

  • 김교원
    • The Journal of Engineering Geology
    • /
    • v.6 no.2
    • /
    • pp.53-58
    • /
    • 1996
  • In order to investigate the source mechanism of micro cracks through acoustic emission measurement induced by rock fracture, careful calibration of the entire linkage of the detecting system, from the transducers to transient recorder, is an essential requirement prior to testing. Transducers and digitiging system are generally the weakest links in the measurement system because they must translate mechanical motions into digital electric signals. In this study, PAC piezoelectric pressure transducers are calibrated with a standard NBS conical shaped displacement transducer and a DG piezoelectric displacement transducer. The NBS and PAC transducers are insensitive to changes in horizontal impingement angle but sensitive to changes in incident angle. The ray path along the logitudinal axis of the tranducer produced a maximum response while the ray path perpendicular to the transducer axis gave a minimum. And a difference in individual transducers factor for a peak-to-peak amplitude of PAC transducers was within 40%. An average PAC transducer coefficient was determined as 77mv/pm by an absolute calibration test using NBS transducer.

  • PDF

The R-Plasmid Transfer and Elimination of Shigella Cultures (Shigella균속의 항균제내성, 전달성 R-plasmid 및 제거에 관한 연구)

  • Hong, Sung-Ro;Lee, Yun-Tai
    • The Journal of the Korean Society for Microbiology
    • /
    • v.21 no.1
    • /
    • pp.33-45
    • /
    • 1986
  • On hundred and forty stains of shigella cultures isolated from the twelve hygiene laboratories of cities and provincial general hospital laboratories in 1983 were tested for their resistance to thirteen antimicrobial drugs and their R-plasmid transfer. Antimicrobial drugs were used amikacin, ampicillin, cephalothin, chloramphenicol, gentamicin, kanamycin, nalidixic acid, rifampicin, streptamycin, tetracycline, tobramycin, cefoperazone and piperacillin. All strains were resistant to one or more of thirteen antimicrobial drugs but 94.3% were susceptible to amikacin, gentamicin and tobramycin of total isolated. The most strains commonly found resistance was to chloramphenicol (94%) followed by streptamycin (93%), tetracyline (92%) piperacillin (90%) ampicillin (83%), cefoperazone (42%), nalidixic acid (14%), cephalothin (17%), rifampicin (22%) and kanamycin (6%), sixty percent of strains among 140 were resistance to ampicillin, chloramphenicol, streptomycin, tetracycline at the same time. The transfer of drug resistance by conjugation was tested and ninety four strains (94.3%) were resistant to one or more drugs were found to transfer their drug resistance of E. coli. percentage of transfer frequency by conjugation was one strains (54%), the transfer frequency of drug resistance varied by donor strains and recipients, but not by selecting drugs. Resistance to nalidixic acid was not transferred by conjugation to recipients. Percentage of plasmid curing after the treatment of acriflavine, acridine orange was about 8%. Among strains cured two strains were tested compare original strains with them in biochemical properties in arginine dihydrolase and arabinose fermentation reaction. It was found to growth curves of No.2 shigella flexneri, serotype 1b, and its derivatives cured with acriflavine in $M{\ddot{u}}ller$ Hinton broth medium (pH 7.4, $38^{\circ}C$) by temperature Gradient Biophoto Recorder TN-1120 (Tokyo, Japan).

  • PDF

Analysis of Underwater Noise in the North Sea (북해에서의 수중소음분석)

  • 윤갑동
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.21 no.1
    • /
    • pp.1-6
    • /
    • 1985
  • The underwater noise was measured by piezo-electric hydrophones submerged in the water at three different depths. The signals were led through connection cables to preamplifiers, and recorded simultaneously by a four channel tape recorder, and analysed by high resolution signal analyzer. The measurements were carried out at the fjord Skossvassen in archipelago off Bergen and at the cost of Norway in the North Sea. The results of the measurements and the analysis showed that the underwater noise consists of a steady broad band noise superposed by intermittent pulse of various strength. The noise levels measured in fjord Skossvassen indicated that they were generally higher at the shallow (10m) hydrophone than at the deeper hydrophone (25m, 50m). This tendency was not very distinct, however, the noise sources are close to the surface. The underwater noise spectrums measured in the open sea of Norway showed almost similar situation in all layers. This tendency showed that the noise sources are not close to the surface but they are far away from the measuring positions.

  • PDF